User Manual for CyberPower models including: PR750LCD3C, PR750LCD3C Smart App Sinewave UPS, PR750LCD3C, Smart App Sinewave UPS, App Sinewave UPS, Sinewave UPS
File Info : application/pdf, 12 Pages, 1.75MB
DocumentDocumentYOUR ULTIMATE ALLY IN POWER INTELLIGENT UPS SERIES PR750LCD3C USER MANUAL 2 1 4 8 9 3 10 5 7 6 Menu Esc Enter 14 UNINTERRUPTIBLE POWER SUPPLY E187679 6G48 11 12 13 FEATURES 1. PowerButton/PowerOnIndicator 2. OnlineIndicator 3. OnBatteryIndicator 4. FaultIndicator 5. BatteryFaultIndicator 6. LCDModuleOperationButtons 7. CloudMonitoring(EthernetPort) 8. EPO(EmergencyPowerOff)Port 9. Serial/USBPortstoPC 10. TVSSScrew 11. SNMP/HTTPNetworkSlot 12. CircuitBreaker 13. ACInputPowerCord 14. BatteryandSurgeProtectedOutlets PRODUCT REGISTRATION ThankyouforpurchasingaCyberPowerproduct.ThisUPSisdesignedtoprovideunsurpassedpower protection,operation,andperformanceduringthelifetimeoftheproduct.Pleasetakeafewminutesto registeryourproductat:www.CyberPowerSystems.com/registration. Registrationcertifiesyourproduct'swarranty,confirmsyourownershipintheeventofaproductlossortheft, andentitlesyoutofreetechnicalsupport.RegisteryourproductnowtoreceivethebenefitsofCyberPower ownership. Cyber Power Systems (USA), Inc. 424112thAvenueEast,Suite400|Shakopee,MN55379|CyberPowerSystems.com IMPORTANT SAFETY WARNINGS (SAVETHESEINSTRUCTIONS) Thismanualcontainsimportantinstructionsthatshouldbefollowedduringinstallationandmaintenanceofthe UPSandbatteries.Pleasereadandfollowallinstructionscarefullyduringinstallationandoperationoftheunit. Readthismanualthoroughlybeforeattemptingtounpack,install,oroperateyourUPS. CAUTION! Topreventtheriskoffireor electricshock,installinatemperatureandhumidity controlledindoorareafreeof conductivecontaminants.(Pleasesee specificationsforacceptabletemperature andhumidityrange). CAUTION!Toreducetheriskofelectricshock,do notremovethecoverexcepttoservicethebattery. Turnoffandunplugtheunitbefore servicingthebatteries.Therearenouserserviceable partsinsideexceptforthebattery. CAUTION!Hazardouslivepartsinsidecanbe energizedbythebatteryevenwhentheACinput powerisdisconnected. CAUTION!TheUPSmustbeconnectedtoanAC poweroutletwithfuseorcircuitbreakerprotection. Donotplugintoanoutletthatisnotgrounded.If youneedtodeenergizethisequipment,turnoffand unplugtheunit. CAUTION!Toavoidelectricshock,turnofftheunit andunplugitfromtheACpowersourcebefore servicingthebatteryorinstallingacomputer component. CAUTION!Toreducetheriskoffire,connectonlyto acircuitprovidedwith20amperesmaximumbranch circuitovercurrentprotectioninaccordancewith theNationalElectricCode,ANSI/NFPA70. CAUTION!Notforuseinacomputerroomas definedintheStandardfortheProtectionof ElectronicComputer/DataProcessingEquipment, ANSI/NFPA75. CAUTION!Donotdisposeofbatteriesinafire.The batteriesmayexplode. CAUTION! TheUPSshouldbeneartheconnected equipmentandeasilyaccessible. DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! CyberPowerSystemsdoesnotsellproductsforlife supportormedicalapplications.DONOTuseinany circumstancethatwouldaffectoperationandsafety oflifesupportequipment,anymedicalapplications orpatientcare. DO NOT USE WITH OR NEAR AQUARIUMS! Toreducetheriskoffireorelectricshock,donotuse withornearanaquarium.Condensationfromthe aquariumcancausetheunittoshortout. DO NOT USE THE UPS ON ANY TRANSPORTATION! Toreducetheriskoffireorelectricshock,donotuse theunitonanytransportationsuchasairplanesor ships.Theeffectofshockorvibrationcausedduring transitandthedampenvironmentcancausetheunit toshortout. INSTALLING YOUR UPS SYSTEM UNPACKING InspecttheUPSuponreceipt. Theboxshouldcontainthefollowing: (a)UPSunit (b)User'smanual (c)Emergencypoweroffcable(gray) (d)USBA+Btypecable (e)Functionsetupguide PowerPanel®Businesssoftwareisavailableonour website.Pleasevisitwww.cyberpowersystems.com andgototheSoftwareSectionforafreedownload. OVERVIEW ThePR750LCD3Cprovidescompletepower protectionfromutilitypowerthatisnotalways consistent. ThePR750LCD3Cfeatures1030Joulesofsurge protectionagainstpowersurgesandmaintenance freebatteriesforlonglastingbatterybackupduring poweroutages.Inadditiontoensuringconsistent powertoyourcomputersystem,thePR750LCD3C alsoincludessoftwarethatwillautomaticallysave youropenfilesandshutdownyourcomputersystem duringautilitypowerloss. AUTOMATIC VOLTAGE REGULATOR ThePR750LCD3Cstabilizesinconsistentutilitypower tonominallevelsthataresafeforequipment.Unstable utilitypowercanbedamagingtoimportantdataand hardware.WithAutomaticVoltageRegulation(AVR), damagingvoltagelevelsarecorrectedtosafelevels. AVRautomaticallyincreaseslowutilitypowertoa consistentandsafe110/120volts. INSTALLING YOUR UPS SYSTEM DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 1. EnsurethattheequipmentpluggedintotheUPS doesnotexceedtheUPSunit'sratedcapacity.If theratedcapacitiesoftheunitareexceeded,an overloadconditionmayoccurandcausetheUPS unittoshutdownorthecircuitbreakertotrip. 2. Therearemanyfactorsthatcanaffectthe amountofpowerthatyourelectronicequipment willrequire.Foroptimalsystemperformancekeep theloadbelow80%oftheunit'sratedcapacity. HARDWARE INSTALLATION GUIDE 1. YournewUPSmaybeusedimmediately uponreceipt.However,toensurethebattery's maximumchargecapacity,itisrecommended thatyouchargethebatteryforatleast8hours. YourUPSisequippedwithanautocharge feature.WhentheUPSispluggedintoanAC outlet,thebatterywillautomaticallycharge whethertheUPSisturnedonoroff.Note:This UPSisdesignedwithasafetyfeaturetokeepthe systemfrombeingturnedonduringshipment. ThefirsttimeyouturntheUPSon,youwillneed tohaveitconnectedtoACpoweroritwillnot powerup. 2. WiththeUPSunitturnedoffandunplugged, connectyourcomputer,monitor,andanyother peripheralsrequiringbatterybackupintothe batterypowersuppliedoutlets.DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum, sump pump or other large electrical devices into the "Battery and Surge Protected Outlets". The power demands of these devices may overload and damage the unit. PLUG IN 3. PlugtheUPSintoa2pole,3wiregrounded receptacle(walloutlet).Makesurethewall branchoutletisprotectedbyafuseorcircuit breakeranddoesnotserviceequipmentwith largeelectricaldemands(e.g.,airconditioner, copier,etc...).Thewarrantyprohibitstheuseof extensioncords,outletstrips,andsurgestrips. 4. Pressthepowerbuttonandtheenterbuttonto turntheuniton.ThePowerOnindicatorlightwill illuminate.Ifanoverloadisdetected,anaudible alarmwillsoundandtheunitwillemitonelong beep.Tocorrectthis,turntheUPSoffandunplug atleastonepieceofequipmentfromthebattery powersuppliedoutlets.Makesurethecircuit breakerisdepressedandthenturntheUPSon. 5. Tomaintainoptimalbatterycharge,leavetheUPS pluggedintoanACoutletatalltimes. 6. TostoretheUPSforanextendedperiod,coverit andstorewiththebatteryfullycharged.Whilein storage,rechargethebatteryeverythreemonths toensurebatterylife. 7. EnsurethewalloutletandUPSarelocated neartheequipmentbeingattachedfor properaccessibility. SYSTEM FUNCTION BLOCK DIAGRAM Input EMI Filter Surge Suppressor Normal Mode Battery Mode Charger AC / DC AVR Output Inverter Battery BASIC OPERATION 1. Power Button / Power On Indicator Usedasthemasteron/offswitchforequipment connectedtothebatterypowersuppliedoutlets. 2. Online Indicator ThisLEDisilluminatedwhentheutilitypoweris normalandtheUPSoutletsareprovidingpower, freeofsurgesandspikes. 3. On Battery Indicator Duringaseverebrownoutorblackout,thisLED isilluminatedandanalarmsounds(twoshort beepsfollowedbyapause)toindicatetheUPSis operatingfromitsinternalbatteries. 4. Fault Indicator ThisLEDisilluminatedifthereisaproblemwith theUPS. 5. Battery Fault Indicator ThisLEDisilluminatedifthereisabatteryissue withtheUPS. 6. LCD Module Operation Buttons Foradditionalinformationonhowtocustomizethe UPS'soperation,pleaserefertotheLCDSetting Guidesectionbelow. 7. Cloud Monitoring (Ethernet Port) ThecardconnectsaUPStoPowerPanelCloudto provideuserstheabilitytomonitortheoperationof theirUPS.Foradditionalinformation,pleaserefer tohttps://www.cyberpowersystems.com/products/ software/powerpanelcloud. *REMINDER:NOTFORTELECOMMUNICATION (TELEPHONE)NETWORK. 8. EPO (Emergency Power Off) Port TheEPO/ROOinterfaceisanIEC60950safety extralowvoltage(SELV)circuit.Thiscircuitmust beseparatedfromhazardousvoltagecircuitsby reinforcedinsulation.Followtheappropriatecircuit diagrambelowtowiretheprovidedgrayEPOcable toyourEPO/ROOconfiguration.Connectisolated drycontacts(ratedtohandle60Vdc,30VacRMS and20mAmaximum)anduseONLYlatching switch. OPTION 1: USER SUPPLIED NORMALLY OPEN SWITCH (RECOMMENDED) 1 ROO SWITCH 2 3 4 N.O.EPO SWITCH OPTION 2: USER SUPPLIED NORMALLY CLOSED SWITCH 1 ROO SWITCH 2 N.C.EPO SWITCH 3 4 3-4 JUMPER *REMINDER:NOTFORTELECOMMUNICATION (TELEPHONE)NETWORK. 9. Serial/USB Ports to PC TheSerialandUSBportsallowconnectionand communicationbetweenthecomputerandtheUPS unit.Note:Onlyoneportcanbeusedatatime. 10. TVSS Screw UsetheTransientVoltageSurgeSuppressionScrew togroundtheUPS. 11. SNMP/HTTP Network Slot Removethecoverpaneltoinstallanoptional RMCARDtoremotelymonitorandmanageyour UPSoveranetwork. 12. Circuit Breaker LocatedonthebackoftheUPS,thecircuitbreaker providesoverloadandfaultprotection. 13. AC Input Power Cord Heavydutypowercord. 14. Battery and Surge Protected Outlets Theunithassixbatterypowered/surgesuppression outletsforconnectedequipmenttoensure temporaryuninterruptedoperationofyour equipmentduringapowerfailure.(DONOTpluga laserprinter,papershredder,copier,spaceheater, vacuum,sumppumporotherlargeelectrical devicesintothe"BatteryandSurgeProtected Outlets".Thepowerdemandsofthesedevicesmay overloadanddamagetheunit.) REPLACING THE BATTERY ReplacementofbatterieslocatedinanOPERATOR ACCESSAREA.PleasereadandfollowtheSafety Instructionsbeforeservicingthebattery. CAUTION!RISKOFEXPLOSIONIFBATTERYIS REPLACEDBYANINCORRECTTYPE.DISPOSE OFUSEDBATTERIESACCORDINGTOLOCAL REGULATIONS. CAUTION!Whenreplacingbatteries,replacewith thesamenumber,manufacturerandmodelname ofthebatteries:CyberPower/RB1270X2Ffor PR750LCD3C.ContactCyberPowerSystemsoryour dealerformoreinformationaboutreplacement batteries. CAUTION! Riskofenergyhazard,24V,maximum 7AmperehourbatteryforPR750LCD3C;.Before replacingbatteries,removeconductivejewelrysuch aschains,wristwatches,andrings.Highenergy throughconductivematerialscouldcausesevere burns. CAUTION! Batteriesareconsideredhazardouswaste andmustbedisposedofproperly.Contactyour localgovernmentformoreinformationaboutproper disposalandrecyclingofbatteries.Donotdisposeof batteriesinafire.Thebatteriesmayexplode. CAUTION! Donotopenormutilatebatteries. Releasedmaterialisharmfultotheskinandeyes.It maybetoxic. CAUTION!Toavoidelectricshock,turnofftheunit andunplugitfromtheACpowersourcesbefore servicingthebattery. REPLACING THE BATTERY - continued CAUTION!Onlyusetoolswithinsulatedhandles.Do notlaytoolsormetalpartsontopofUPSorbattery terminals. BATTERY REPLACEMENT PROCEDURE: PR750LCD3C 1. Turnoffandunplugallconnectedequipment. 2. TurntheUPSoffandunplugitfromtheAC powersource. 3. Pushthebuckleandremovethefrontpanelof theUPS. 4. Loosenthescrewandremovethebattery compartmentplate. 5. Removethebatteriesfromthecompartment. 6. Disconnectthebatterywiresfromthebatteries. 7. Installthereplacementbatteriesbyconnecting thewirebundle(composedofoneredwire andoneblackwire)totheconnectorfromthe batterypack. 8. Putthebatteriesbackintothecompartment. 9. Reinstallthebatterycompartmentplateand tightenthescrewbackintoplace. 10.PutthefrontpanelbackontheUPS. 11. ConnecttoACpowerandchargethenew batteriesforupto8hourstoinsureafullcharge. PUSH LCD SETTING GUIDE PressMenuButtontoenterSetupMenuanduseUp/Down Buttontoscrollthroughmenus.PressEnterButtontogointo theselectedmenuandusetheUp/DownButtonandEnter Buttontoselectthesettingitemandtocompletethesetting. EscButtonispressedtoexitthesubmenuandgobackto previouspage. Formoreinformationaboutfunctionssetup,pleasereferto theFunctionSetupGuide. Menu Esc Enter Menu BasicSetup AmbientSetup OutletControl Test Logs About UtilityQuality Sensitivity Item ECOOn/Off LEDBrightness UPSConfiguration SelfTest Event110 UPSModelName UPSSerialNumber LastBatteryChangeDate NextBatteryChangeDate LCDHibernation CyclingDisplay AlarmTest UPSFirmwareVersion IPAddress MACID AudibleAlarm ServicePortnumber LCD SETTING GUIDE - continued Menu Item AdvancedSetup OutputVoltage MinimumOutputVoltage MaximumOutputVoltage LowBatteryThreshold BatteryChangeDate ScheduleTest DateandTime PowerMeterRest IPAccess IPAddress SubnetMask Gateway WiringFault FirmwareUpdate** BacktoDefault **Onlydisplayedinstandby mode TROUBLESHOOTING Problem Possible Cause Solution Circuitbreakerbuttonis projectingfromthebackofthe unit. TheUPSdoesnotperform expectedruntime. Circuitbreakerhastrippeddueto anoverload. TurntheUPSoffandunplugat leastonepieceofequipment. Wait10seconds,resetthecircuit breakerbypressingthebuttonin, andthenturntheUPSon. Batteriesarenotfullycharged. Rechargethebatterybyleaving theUPSpluggedin. Batteriesarewornout. ContactCyberPowerSystems aboutreplacementbatteries. Thepowerbuttonisdesigned topreventdamagefromrapidly turningitoffandon. TurntheUPSoff.Wait10seconds andthenturntheUPSon. TheUPSwillnotturnon. TheunitisnotconnectedtoanAC Theunitmustbeconnectedtoa outlet. 120V50/60Hzoutlet. Batteriesarewornout. ContactCyberPowerSystems aboutreplacementbatteries. Mechanicalproblem. ContactCyberPowerSystemsfor repair. PowerPanel®Businessisinactive. TheUSB/serialcableisnot connected. TheUSB/serialcableisconnected tothewrongport. ConnecttheUSB/serialcableto theUPSunitandanopenUSB/ serialportonthebackofthe computer. Checkthebackofthecomputer foranadditionalUSB/serialport. Movethecabletothisport. Overload Removeexcessiveloadandrestart theUPS. TheFaultLEDisilluminated. OutputShort BatteryOvercharge ContactCyberPowerSystems. ContactCyberPowerSystems. OverTemperature ContactCyberPowerSystems. Additionaltroubleshootinginformationcanbefoundatwww.cyberpowersystems.com/support. TECHNICAL SPECIFICATIONS MODEL Capacity(VA) Capacity(Watts) INPUT NominalInputVoltage InputFrequencyRange InputPlugType OUTPUT OutputReceptacles OnBatteryOutputVoltage OnBatteryOutputFrequency TransferTime(Typical) OverloadProtection SURGE PROTECTION AND FILTERING Lightning/SurgeProtection BATTERY ReplaceableBatteryPack SealedMaintenanceFree RechargeTime(Typical) WARNING DIAGNOSTICS Indicators AudibleAlarms ENVIRONMENTAL OperatingTemperature OperatingRelativeHumidity StorageTemperature StorageRelativeHumidity MANAGEMENT ConnectivityPorts RemoteMonitoring Software SNMP/HTTPNetworking Software PHYSICAL Dimensions(WxHxD)(in/mm) Weight(lb/kg) SAFETY ConformanceApprovals PR750LCD3C 750 750 100Vac125Vac 50/60Hz+/3HzAutosensing NEMA515P (6)NEMA515R 120Vac+/5% (Underatestloadoflessthan60%.Whentheloadexceeds60%, theoutputvoltagerangemayexceed5%.) 50/60Hz+/1% Typical4ms(Atnormalsensitivity) InternalCurrentLimiting Yes(1,350J) RB1270X2F Yes 8hoursto90%(Recoverto90%afterfullloaddischarge) LCDDisplay,LEDIndicators(PowerOn,Online,OnBattery,UPSFault,BatteryFault) OnBattery,BatteryLow,Overload,UPSFault,ReplaceBattery 32°Fto104°F(0°Cto40°C) 0to95%Noncondensing 5°Fto113°F(15°Cto45°C) 0to95%Noncondensing (1)USBPort,(1)SerialPort BuiltinCloudcard PowerPanelCloud Yes,withoptionalRMCARD205/400 PowerPanel®Business 138x162x360(mm)/5.43x6.37x14.17(in) 11.8kg/26.01lbs UL1778,CSAC22.2No.107.3,andFCCClassB NETWORK OPERATION Local Monitoring ConnecteithertheUSBcableorSerialcabletothecorrespondingportontheUPSandonthecomputerwith PowerPanelBusinesssoftwareinstalled.PowerPanelBusinesssoftwareisavailableonourwebsite.Pleasego towww.cyberpowersystems.com/products/software/powerpanelbusinessforthefreedownload. Note:USBandSerialportcannotbeusedsimultaneously.SerialportwillbedisablediftheUSBportisused. Remote Monitoring ThisproductisequippedwithaSNMP/HTTPnetworkslot.IfyouwouldliketocontroltheUPSfromaremote location,especiallyunderaprivatenetwork,aCyberPowerRemoteManagementCard(RMCARD)isrequired. Formoreinformation,visitwww.cyberpowersystems.com. Cloud Monitoring ThisproductfeaturesanEthernetportforCloudConnection,whichmakesiteasytomonitorCyberPower UPSsystemsfromanywhere.FollowbelowstepstogetyourUPSonCloud. 1. Hardwareinstallation:ConnecttheCloudMonitoring(EthernetPort)ontheUPSrearpaneltoawalljack ornetworkswitchusingasuitableEthernetcable. LED Indicators Conditions Link Off TheUPSisnotconntectedtothenetwork On(Yellow) TheUPSisconnectedtothenetwork. Off TheCloudMonitoring(EthernetPort)isnotpowered. Tx/Rx On(Green) TheCloudMonitoring(EthernetPort)ispowered. Flashing Receivingortransmittingdatapacket. 2. Applicationinstallation:InstallPowerPanelCloudApponyoursmartphoneandthenlaunchthe application.PowerPanelCloudAppisavailablefordownloadontheAppleAppStoreorGooglePlay. iOS Android 3. Signupandlogin. NETWORK OPERATION - continued 4. AddadeviceinthePowerPanelCloudApp. (a) Click"+"intheupperrightcornerofthehomepage. (b) Locatethe"AddDevicebyQRCode"toaddyourCloudUPS. (c) ScantheQRCodeonthetopsideoftheUPS.IftheQRCodescanwassuccessful,click"Add" andnamethedeviceyouaremonitoring. (d) Afterthesetupiscompleted,youwillseeyourdeviceonthehomepage. (e) WaittilltheUPSissuccessfullyconfigured. 5. StartmonitoringyourUPS! InadditiontotheMobileApp,youcanaccessthePowerPanelCloudaccountviaawebbrowser: https://powerpanel.cyberpower.com.Formoreinformation,pleaserefertothePowerPanelCloudUser'sManual. CYBERPOWER GREENPOWER UPSTM TECHNOLOGY Advanced Energy-Saving Patented Bypass Technology CyberPower'spatentedGreenPowerUPSTMwithBypassTechnologyreducesUPSenergy costsbyupto75%comparedtoconventionalUPSmodels.Evenwhenutilitypoweris normal,conventionalUPSmodelsconstantlypasspowerthroughatransformer.Bycon trast,undernormalconditionstheadvancedcircuitryofaGreenPowerUPSTMbypasses thetransformer.Asaresult,thepowerefficiencyissignificantlyincreasedwhilede GREENPOWER UPSTM EnergySavingTechnology creasingwasteheat,usinglessenergy,andreducingenergycosts.Whenanabnormal powerconditionoccurs,theGreenPowerUPSTMautomaticallyrunspowerthroughitstransformertoregulate voltageandprovide"safe"power.Sinceutilitypowerisnormalover88%ofthe time,theGreenPowerUPSTMoperatesprimarilyinitsefficientbypassmode.TheGreenPowerUPSTMisalso manufacturedinaccordancewiththeRestrictiononHazardousSubstances(RoHS)directivemakingitone ofthemostenvironmentallyfriendlyonthemarkettoday. FCC COMPLIANCE STATEMENT Thisdevicecomplieswithpart15oftheFCCrules.Operationissubjecttothefollowingtwoconditions: (1)thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustacceptanyinterference received,includinginterferencethatmaycauseundesiredoperation. Note:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice,pursuantto part15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferenceina residentialinstallation.Thisequipmentgenerates,uses,andcanradiateradiofrequencyenergyand,ifnotinstalledand usedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradiocommunications.However,thereis noguaranteethatinterferencewillnotoccurinaparticular installation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcanbedetermined byturningtheequipmentoffandon,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthe followingmeasures: Reorientorrelocatethereceivingantenna. Increasetheseparationbetweentheequipmentandreceiver. Connecttheequipmenttoanoutletonacircuitdifferentfromthattowhichthereceiverisconnected. Consultthedealeroranexperiencedradio/TVtechnicianforhelp. Warning:Changesormodificationsnotexpresslyapprovedbythepartyresponsibleforcompliancecouldvoidthe user'sauthoritytooperatetheequipment. Canadian Compliance Statement CANICES3(B)/NMB3(B) LIMITED WARRANTY AND CONNECTED EQUIPMENT GUARANTEE Pleasevisitwww.CyberPowerSystems.comforacopyoftheLimitedWarrantyandConnectedEquipment Guarantee. Where Can I Get More Information? TheapplicationoftheUnitedNationsConventionofContractsfortheInternationalSaleof Goodsisexpresslyexcluded.CyberPoweristhewarrantorunderthisLimitedWarranty. ForfurtherinformationpleasefeelfreetocontactCyberPowerat: CyberPowerSystems(USA),Inc.424112thAveE.,STE400,Shakopee,MN55379; callusat(877) 297-6937;orsubmitawebticketonlineatcyberpowersystems.com/support. CyberPowerSystems(USA),Inc.encouragesenvironmentallysoundmethodsfordisposal andrecyclingofitsUPSproducts.Pleasedisposeand/orrecycleyourUPSandbatteriesin accordancetothelocalregulationsofyourstate. WARNING:ThisproductcanexposeyoutochemicalsincludingbisphenolA(BPA)andstyrene,whichisknowntothe StateofCaliforniatocausereproductiveharmandcancer.Formoreinformation,gotowww.P65Warnings.ca.gov. ©2024CyberPowerSystems(USA),Inc.PowerPanel®isaregisteredtrademarksofCyberPowerSystems(USA),Inc. Allrightsreserved.Allothertrademarksusedarepropertyoftheirrespectiveowners. K01000099102