Instruction Manual for Advanced Amplifiers models including: AA-1M6G-30, AA-1M6G-30 Solid State RF Amplifier System, Solid State RF Amplifier System, RF Amplifier System, Amplifier System
Advanced Amplifiers 1M6G-30 Solid State RF Am... | ATEC
File Info : application/pdf, 9 Pages, 2.28MB
DocumentDocumentInstruction Manual Including Quick Start Guide Advanced Amplifiers Solid State RF Amplifier System AA-1M6G-30 1 MHz - 6.0 GHz, 30 Watt, 45dB Min 1 | P a g e - Ver. 1.0 11-22 Table of Contents SAFETY INSTRUCTIONS ................................................................................................................................................................ 3 SPECIFICATIONS ............................................................................................................................................................................... 4 ELECTRICAL SPECIFICATIONS: 50, 25°C .................................................................................................................... 4 ENVIRONMENTAL CHARACTERISTICS...........................................................................................................................4 MECHANICAL SPECIFICATIONS........................................................................................................................................4 OPERATING INSTRUCTIONS & GENERAL INFORMATION ........................................................................................... 5 INTRODUCTION....................................................................................................................................................................... 5 INCOMING INSPECTION ..................................................................................................................................................... 5 RF & AC CABLE CONNECTION ........................................................................................................................................ 5 RF TURN ON PROCEDURE ................................................................................................................................................. 5 RF TURN OFF PROCEDURE ................................................................................................................................................ 5 DECLARATION OF CE CONFORMITY.............................................................................................................................6 LIMITED WARRANTY ............................................................................................................................................................. 6 CONTACT INFORMATION ................................................................................................................................................... 6 FRONT & REAR PANEL DESCRIPTIONS.................................................................................................................................7 FRONT PANEL VIEW .............................................................................................................................................................. 7 REAR PANEL VIEW..................................................................................................................................................................8 SYSTEM OUTLINE VIEW................................................................................................................................................................9 2 | P a g e - Ver. 1.0 11-22 SAFETY INSTRUCTIONS BEFORE USING THIS EQUIPMENT Read this manual and become familiar with safety markings and instructions. Inspect unit for any sign of external damage. Do not use this equipment if there is physical damage or missing parts. Verify the input AC voltage to the main power supply. For a system with a digital controller option DO NOT USE OR CONNECT a PoE enabled ethernet switch to a system. Our digital controller does not support PoE connection and will cause permanent damages to a controller unit. INTENDED USE This product is intended for general laboratory use in a wide variety of industrial and scientific applications. RF OUTPUT LOAD & PROPER GROUNDING REQUIRED The RF output connector must be connected to a load before the AC switch is turned on. AC & RF power must be off before disconnecting the output load or other components. The main power source to the equipment must have an uninterrupted safety ground that has sufficient size to the power cord. REPAIR & MAINTENANCE All repair or maintenance work must be performed by a factory authorized technician in order to extend the operating life of this equipment and not to void any outstanding warranty. FORCED AIR COOLING This equipment requires forced air cooling. All air inlets and outlets must be cleared and free of blocking at all time. Insufficient air flow will result in damaged equipment. SAFETY SYMBOLS This symbol is marked on the equipment when it is necessary for the user to refer to the manual for important safety information. This symbol is indicated in the Table of Contents to assist in locating pertinent information. Dangerous voltages are present. Use extreme care. The caution symbol denotes a potential hazard. Attention must be given to the statement to prevent damage, destruction or harm. This symbol indicates protective earth terminal. 3 | P a g e - Ver. 1.0 11-22 SPECIFICATIONS ELECTRICAL SPECIFICATIONS: 50, 25°C Parameter Specification Band A B Operating Frequency Band 1 - 1000 MHz 1 - 6 GHz Power Output @ Psat 30 Watt Min / 50 Watt Typ Power Gain 45 dB Min Power Gain Flatness 4.0 dB p-p Max Gain Adjustment Range 20 dB Min Input Return Loss -10 dB Max 2-Tone Intermodulation (IMD) -30 dBc Typ Harmonics <-20 dBc Typ Spurious -60 dBc Max Operating Voltage 100 - 240 VAC Power Consumption 500 Watt Max Input Power Protection +10 dBm Max1 Load VSWR Protection 6 : 1: Max2 Sample Port (optional) -40 dB 1 Units with optional digital monitor and control, for basic units <10 Sec without damage 2 Units with optional digital monitor and control, for basic units <1 minute at rated Pout ENVIRONMENTAL CHARACTERISTICS Parameter Operating Ambient Temperature Storage Temperature Relative Humidity Altitude Shock & Vibration 3 MIL Spec available for quotation Specification 0 to +50 °C -40 to +85 °C up to 95 % 3000 meters Normal transport3 MECHANICAL SPECIFICATIONS Parameter Dimensions W x H x D Weight RF Connectors Input/Output/Sample Interface Connector AC Power Cooling OPTIONAL: Digital Monitor & Control (DMC) FWD, REV, VSWR, GAIN, ALC, V & I, TEMP, Optional Safety Interlock (INT) e Specification 430 x 88 x 700 mm 12 Kg. N-Female 9-Pin D-Sub IEC 60320-C14 Built in Fan Cooling Ethernet RJ-45 TCP/IP, RS422/485, USB Optional GPIB Interface Open=STBY/Short=RFON Notes Band switching @ 15 mS Max CW or Pulse 0dBm or less for rated Pout Constant input power Local or remote 35dBm/Tone, = 1MHz At rated Pout Non-harmonics 47 - 63 Hz At rated Pout Foldback @ preset limit N-Female Notes Non-condensing Notes 2U, excluding handles Front or rear panel Rear panel Or equivalent Variable speed IEEE rear panel BNC-F rear panel 4 | P a g e - Ver. 1.0 11-22 OPERATING INSTRUCTIONS & GENERAL INFORMATION INTRODUCTION Advanced Amplifiers is an amplifier equipment and services company supporting commercial and government organizations worldwide. Headquartered in San Diego, California, the company utilizes its global network of resources to effectively serve and support customer requirements. As a unique original equipment manufacturer of power amplifiers ranging from 10KHz to 40GHz with various output power levels for CW & pulse testing applications, we can also fully support custom designs and manufacturing requirements for both small and large volume procurements. We bring decades of combined experience in the RF field for numerous applications including and not limited to, EMI/EMC, communications, and various commercial and industry standards. With our in-house capabilities and fully equipped testing facilities, Advanced Amplifiers is committed to provide the best in RF products with industry leading quality and lead times. INCOMING INSPECTION Inspect unit for any sign of external damage. Do not use this equipment if there is physical damage or missing parts. Inspect all front and rear panel connectors for damage. Inspect fans and their airways for any damage or blockings. For a unit with a digital controller option, the USB and ethernet interface and commands list is in the second part of the manual. RF & AC CABLE CONNECTION RF Input and Output connectors are outlined in the specifications table. Use the standard AC cable that was supplied by the manufacturer or higher power rating cables than the manual specifies. Refer to the front and rear panel description page for the location of RF and AC connectors. For a system with a digital controller option DO NOT USE OR CONNECT a PoE enabled ethernet switch to a system. Our digital controller does not support PoE connection and will cause permanent damages to a controller unit. RF TURN ON PROCEDURE Connect RF input to an RF Pulse Generator and Gating signal. Connect a suitable load for the power rated and continuous operation to the output connector. Turn on the AC switch, display will show STANDBY. Optionally, connect the unit to a digital control Software or Ethernet connection. Set the RF generator to nominal 0dBm and set the desired frequency in the specified range. Select Gain or ALC and set to the desirable output power level then press the ONLINE button. Use the front panel LCD gain adjust or the remote function to adjust the output power on the power meter and the LCD screen to desired levels. Refer to Appendix-1 for detailed operating instructions of the local and remote controller. RF TURN OFF PROCEDURE Decrease the RF drive from the RF generator to below -20dBm and press STANDBY on the LCD or via the control software. Turn off AC switch on the front panel. Disconnect any unnecessary cable connections. 5 | P a g e - Ver. 1.0 11-22 DECLARATION OF CE CONFORMITY We, Advanced Amplifiers Corp, declare under our sole responsibility that the product to which this declaration relates is in conformity with the following standard(s) or other normative document(s): Council Directive 98/37/EC on the Safety of Machinery Directive Council Directive 2014/35/EC on Low Voltage Equipment Safety LIMITED WARRANTY Advanced Amplifiers warrants that goods delivered hereunder, at the time of delivery, will be free from defects in workmanship and material and will conform to the requirements of the purchase order. Seller's liability hereunder shall be limited to the repair or replacement of defective goods F.O.B. factory of which Seller is modified in writing by Buyer within three (3) years following delivery thereof to Buyer, and in no event will Seller be liable for incidental, special or consequential damages. (Note: One (1) year warranty for moving parts such as fans and power supplies). The foregoing warranty is in lieu of all other warranties express or implied (except as to title), including any implied warranty of merchantability or suitability for purpose or against infringement. . CONTACT INFORMATION Please send all inquiries to: Advanced Amplifiers 10401 Roselle Street San Diego, CA 92121 WEB: WWW.ADVANCEDAMPLIFIERS.COM EMAIL: SALES@ADVANCEDAMPLIFIERS.COM COPYRIGHT & TRADEMARKS Copyright 2022 Advanced Amplifiers, All rights reserved. All other trademarks and brand names are the property of their respective proprietors. 6 | P a g e - Ver. 1.0 11-22 FRONT PANEL VIEW FRONT & REAR PANEL DESCRIPTIONS No. Title Function 1 RF SAMPLE A N Female, RF SAMPLE Connector. SAMPLE PORT MUST BE TERMINATED AT ALL TIME 2 RF SAMPLE B N Female, RF SAMPLE Connector. SAMPLE PORT MUST BE TERMINATED AT ALL TIME 3 0dBm INPUT N Female, 0dBm INPUT Connector. 4 FAULT LED System Fault LED: Turn ON an LED when Over-Temp, Ext. Shutdown. 5 POWER SWITCH System Power Switch. 6 LCD DISPLAY 4" Touch screen LCD Display, System Control LCD Panel. 7 | P a g e - Ver. 1.0 11-22 REAR PANEL VIEW No. Title Function 1 AC POWER CONNECTOR AC Power Input 100 ~ 240VAC, 47/63Hz, IEC60320-14 Connector. System RS-422 Communication / Gating Signal Female 9-Pin D-Sub Connector. P1 TX- P6 N/C 2 RS-422 P2 TX+ P3 RX+ P7 N/C P8 N/C P4 RX- P9 N/C P5 GND (RS-422) 3 GPIB IEEE-488 GPIB Interface Connector, Female. 4 DEBUG System Controller Debugging Female Connector. Port access requires factory authorization 5 USB USB Communication Connector, Type A Female. Ethernet Communication Female Connector, RJ-45. For a system with a digital controller option DO NOT USE OR 6 ETHERNET CONNECT a PoE enabled ethernet switch to a system. Our digital controller does not support PoE connection and will cause permanent damages to a controller unit. BNC Female, Safety Interlock Connector 7 INTERLOCK Interlock Close Circuit : Normal operation Interlock Open Circuit : RF Off operation 8 GND Frame Ground. 9 50 OUTPUT N Female, 50 OUTPUT Connector. 10 Cooling FAN System Outlet Cooling FAN. 8 | P a g e - Ver. 1.0 11-22 SYSTEM OUTLINE VIEW 9 | P a g e - Ver. 1.0 11-22