Instruction Manual for Advanced Amplifiers models including: AA-1M6G-30, AA-1M6G-30 Solid State RF Amplifier System, Solid State RF Amplifier System, RF Amplifier System, Amplifier System

jUng kOnG

Manual

Advanced Amplifiers 1M6G-30 Solid State RF Am... | ATEC


File Info : application/pdf, 9 Pages, 2.28MB

PDF preview unavailable. Download the PDF instead.

amp2139db-aa-1m6g-30-manual-v1-0-atec
Instruction Manual Including Quick Start Guide Advanced Amplifiers
Solid State RF Amplifier System AA-1M6G-30
1 MHz - 6.0 GHz, 30 Watt, 45dB Min
1 | P a g e - Ver. 1.0 ­ 11-22

Table of Contents
SAFETY INSTRUCTIONS ................................................................................................................................................................ 3 SPECIFICATIONS ............................................................................................................................................................................... 4
ELECTRICAL SPECIFICATIONS: 50, 25°C .................................................................................................................... 4 ENVIRONMENTAL CHARACTERISTICS...........................................................................................................................4 MECHANICAL SPECIFICATIONS........................................................................................................................................4 OPERATING INSTRUCTIONS & GENERAL INFORMATION ........................................................................................... 5 INTRODUCTION....................................................................................................................................................................... 5 INCOMING INSPECTION ..................................................................................................................................................... 5 RF & AC CABLE CONNECTION ........................................................................................................................................ 5 RF TURN ON PROCEDURE ................................................................................................................................................. 5 RF TURN OFF PROCEDURE ................................................................................................................................................ 5 DECLARATION OF CE CONFORMITY.............................................................................................................................6 LIMITED WARRANTY ............................................................................................................................................................. 6 CONTACT INFORMATION ................................................................................................................................................... 6 FRONT & REAR PANEL DESCRIPTIONS.................................................................................................................................7 FRONT PANEL VIEW .............................................................................................................................................................. 7 REAR PANEL VIEW..................................................................................................................................................................8 SYSTEM OUTLINE VIEW................................................................................................................................................................9
2 | P a g e - Ver. 1.0 ­ 11-22

SAFETY INSTRUCTIONS BEFORE USING THIS EQUIPMENT
Read this manual and become familiar with safety markings and instructions. Inspect unit for any sign of external damage. Do not use this equipment if there is physical damage or missing parts. Verify the input AC voltage to the main power supply. For a system with a digital controller option ­ DO NOT USE OR CONNECT a PoE enabled ethernet switch to a system. Our digital controller does not support PoE connection and will cause permanent damages to a controller unit.
INTENDED USE
This product is intended for general laboratory use in a wide variety of industrial and scientific applications.
RF OUTPUT LOAD & PROPER GROUNDING REQUIRED
The RF output connector must be connected to a load before the AC switch is turned on. AC & RF power must be off before disconnecting the output load or other components. The main power source to the equipment must have an uninterrupted safety ground that has sufficient size to the power cord.
REPAIR & MAINTENANCE
All repair or maintenance work must be performed by a factory authorized technician in order to extend the operating life of this equipment and not to void any outstanding warranty.
FORCED AIR COOLING
This equipment requires forced air cooling. All air inlets and outlets must be cleared and free of blocking at all time. Insufficient air flow will result in damaged equipment.
SAFETY SYMBOLS
This symbol is marked on the equipment when it is necessary for the user to refer to the manual for important safety information. This symbol is indicated in the Table of Contents to assist in locating pertinent information.
Dangerous voltages are present. Use extreme care.
The caution symbol denotes a potential hazard. Attention must be given to the statement to prevent damage, destruction or harm. This symbol indicates protective earth terminal.
3 | P a g e - Ver. 1.0 ­ 11-22

SPECIFICATIONS

ELECTRICAL SPECIFICATIONS: 50, 25°C

Parameter

Specification

Band

A

B

Operating Frequency Band

1 - 1000 MHz

1 - 6 GHz

Power Output @ Psat

30 Watt Min / 50 Watt Typ

Power Gain

45 dB Min

Power Gain Flatness

4.0 dB p-p Max

Gain Adjustment Range

20 dB Min

Input Return Loss

-10 dB Max

2-Tone Intermodulation (IMD)

-30 dBc Typ

Harmonics

<-20 dBc Typ

Spurious

-60 dBc Max

Operating Voltage

100 - 240 VAC

Power Consumption

500 Watt Max

Input Power Protection

+10 dBm Max1

Load VSWR Protection

6 : 1: Max2

Sample Port (optional)

-40 dB

1 Units with optional digital monitor and control, for basic units <10 Sec without damage 2 Units with optional digital monitor and control, for basic units <1 minute at rated Pout

ENVIRONMENTAL CHARACTERISTICS
Parameter Operating Ambient Temperature Storage Temperature Relative Humidity Altitude Shock & Vibration
3 MIL Spec available for quotation

Specification 0 to +50 °C -40 to +85 °C up to 95 % 3000 meters Normal transport3

MECHANICAL SPECIFICATIONS
Parameter Dimensions W x H x D Weight RF Connectors Input/Output/Sample Interface Connector AC Power Cooling OPTIONAL: Digital Monitor & Control (DMC) FWD, REV, VSWR, GAIN, ALC, V & I, TEMP, Optional Safety Interlock (INT)
e

Specification 430 x 88 x 700 mm
12 Kg. N-Female 9-Pin D-Sub IEC 60320-C14 Built in Fan Cooling Ethernet RJ-45 TCP/IP, RS422/485, USB Optional GPIB Interface Open=STBY/Short=RFON

Notes
Band switching @ 15 mS Max CW or Pulse
0dBm or less for rated Pout Constant input power Local or remote
35dBm/Tone,  = 1MHz At rated Pout Non-harmonics 47 - 63 Hz At rated Pout
Foldback @ preset limit N-Female
Notes
Non-condensing
Notes 2U, excluding handles
Front or rear panel Rear panel
Or equivalent Variable speed IEEE rear panel BNC-F rear panel

4 | P a g e - Ver. 1.0 ­ 11-22

OPERATING INSTRUCTIONS & GENERAL INFORMATION
INTRODUCTION
Advanced Amplifiers is an amplifier equipment and services company supporting commercial and government organizations worldwide.
Headquartered in San Diego, California, the company utilizes its global network of resources to effectively serve and support customer requirements.
As a unique original equipment manufacturer of power amplifiers ranging from 10KHz to 40GHz with various output power levels for CW & pulse testing applications, we can also fully support custom designs and manufacturing requirements for both small and large volume procurements. We bring decades of combined experience in the RF field for numerous applications including and not limited to, EMI/EMC, communications, and various commercial and industry standards.
With our in-house capabilities and fully equipped testing facilities, Advanced Amplifiers is committed to provide the best in RF products with industry leading quality and lead times.
INCOMING INSPECTION
Inspect unit for any sign of external damage. Do not use this equipment if there is physical damage or missing parts. Inspect all front and rear panel connectors for damage. Inspect fans and their airways for any damage or blockings. For a unit with a digital controller option, the USB and ethernet interface and commands list is in the second part of the manual.
RF & AC CABLE CONNECTION
RF Input and Output connectors are outlined in the specifications table. Use the standard AC cable that was supplied by the manufacturer or higher power rating cables than the manual specifies. Refer to the front and rear panel description page for the location of RF and AC connectors.
For a system with a digital controller option ­ DO NOT USE OR CONNECT a PoE enabled ethernet switch to a system. Our digital controller does not support PoE connection and will cause permanent damages to a controller unit.
RF TURN ON PROCEDURE
Connect RF input to an RF Pulse Generator and Gating signal. Connect a suitable load for the power rated and continuous operation to the output connector. Turn on the AC switch, display will show STANDBY. Optionally, connect the unit to a digital control Software or Ethernet connection. Set the RF generator to nominal 0dBm and set the desired frequency in the specified range. Select Gain or ALC and set to the desirable output power level then press the ONLINE button. Use the front panel LCD gain adjust or the remote function to adjust the output power on the power meter and the LCD screen to desired levels.
Refer to Appendix-1 for detailed operating instructions of the local and remote controller.
RF TURN OFF PROCEDURE
Decrease the RF drive from the RF generator to below -20dBm and press STANDBY on the LCD or via the control software. Turn off AC switch on the front panel. Disconnect any unnecessary cable connections.
5 | P a g e - Ver. 1.0 ­ 11-22

DECLARATION OF CE CONFORMITY
We, Advanced Amplifiers Corp, declare under our sole responsibility that the product to which this declaration relates is in conformity with the following standard(s) or other normative document(s): Council Directive 98/37/EC on the Safety of Machinery Directive Council Directive 2014/35/EC on Low Voltage Equipment Safety
LIMITED WARRANTY
Advanced Amplifiers warrants that goods delivered hereunder, at the time of delivery, will be free from defects in workmanship and material and will conform to the requirements of the purchase order. Seller's liability hereunder shall be limited to the repair or replacement of defective goods F.O.B. factory of which Seller is modified in writing by Buyer within three (3) years following delivery thereof to Buyer, and in no event will Seller be liable for incidental, special or consequential damages. (Note: One (1) year warranty for moving parts such as fans and power supplies). The foregoing warranty is in lieu of all other warranties express or implied (except as to title), including any implied warranty of merchantability or suitability for purpose or against infringement. .
CONTACT INFORMATION
Please send all inquiries to: Advanced Amplifiers 10401 Roselle Street San Diego, CA 92121 WEB: WWW.ADVANCEDAMPLIFIERS.COM EMAIL: SALES@ADVANCEDAMPLIFIERS.COM
COPYRIGHT & TRADEMARKS
Copyright 2022 Advanced Amplifiers, All rights reserved. All other trademarks and brand names are the property of their respective proprietors.
6 | P a g e - Ver. 1.0 ­ 11-22

FRONT PANEL VIEW

FRONT & REAR PANEL DESCRIPTIONS

No.

Title

Function

1

RF SAMPLE A

N Female, RF SAMPLE Connector. SAMPLE PORT MUST BE TERMINATED AT ALL TIME

2

RF SAMPLE B

N Female, RF SAMPLE Connector. SAMPLE PORT MUST BE TERMINATED AT ALL TIME

3

0dBm INPUT

N Female, 0dBm INPUT Connector.

4

FAULT LED

System Fault LED: Turn ON an LED when Over-Temp, Ext. Shutdown.

5

POWER SWITCH System Power Switch.

6

LCD DISPLAY

4" Touch screen LCD Display, System Control LCD Panel.

7 | P a g e - Ver. 1.0 ­ 11-22

REAR PANEL VIEW

No.

Title

Function

1 AC POWER CONNECTOR AC Power Input 100 ~ 240VAC, 47/63Hz, IEC60320-14 Connector.

System RS-422 Communication / Gating Signal Female 9-Pin D-Sub Connector.

P1 TX-

P6 N/C

2

RS-422

P2 TX+ P3 RX+

P7 N/C P8 N/C

P4 RX-

P9 N/C

P5 GND (RS-422)

3

GPIB

IEEE-488 GPIB Interface Connector, Female.

4

DEBUG

System Controller Debugging Female Connector. Port access requires factory authorization

5

USB

USB Communication Connector, Type A Female.

Ethernet Communication Female Connector, RJ-45.

For a system with a digital controller option ­ DO NOT USE OR

6

ETHERNET

CONNECT a PoE enabled ethernet switch to a system. Our digital

controller does not support PoE connection and will cause permanent

damages to a controller unit.

BNC Female, Safety Interlock Connector

7

INTERLOCK

Interlock Close Circuit : Normal operation

Interlock Open Circuit : RF Off operation

8

GND

Frame Ground.

9

50 OUTPUT

N Female, 50 OUTPUT Connector.

10

Cooling FAN

System Outlet Cooling FAN.

8 | P a g e - Ver. 1.0 ­ 11-22

SYSTEM OUTLINE VIEW
9 | P a g e - Ver. 1.0 ­ 11-22



References

Microsoft Word 2016