User Manual for STMicroelectronics models including: RHFAD128 GUI Rad-Hard 8-Channel 12-bit A-D Converter, RHFAD128, GUI Rad-Hard 8-Channel 12-bit A-D Converter, 8-Channel 12-bit A-D Converter, 12-bit A-D Converter, A-D Converter, Converter

The RHFAD128 GUI The RHFAD128 GUI - User manual

STMICROELECTRONICS

UM3165 The RHFAD128 GUI

RHFAD128 - Rad-Hard 8-channel 12-bit A/D converter - STMicroelectronics

The RHFAD128 GUI - User manual

29 mag 2023 — The RHFAD128 is specifically designed to sustain ionizing dose and heavy ions for space applications by using a high-end proven CMOS technology.


File Info : application/pdf, 14 Pages, 728.31KB

PDF preview unavailable. Download the PDF instead.

um3165-the-rhfad128-gui-stmicroelectronics
UM3165
User manual
The RHFAD128 GUI
Introduction
The RHFAD128 is specifically designed to sustain ionizing dose and heavy ions for space applications by using a high-end proven CMOS technology. This device is a low-power, multiplexed eight-channel 12-bit analog-to-digital converter for conversion from 50 ksps to 1 Msps. The architecture is based on the successive-approximation register with internal track-and-hold. The RHFAD128 features 8 analog inputs that can be programmed to be either 8 single-ended or 4 differential inputs using the control register bits. The output serial data are straight binary and are compatible with SPI. EVAL-RHFAD128V2 is the evaluation board of the RHFAD128. This board can be connected to a NUCLEO-L476RG and be monitored with a graphical user interface (GUI): the RHFAD128_GUI.

UM3165 - Rev 1 - May 2023 For further information contact your local STMicroelectronics sales office.

www.st.com

1
1.1
1.2
1.2.1

Getting started

System requirements
The RHFAD128_GUI software needs the following system requirements to perform:

Table 1. System requirements

NUCLEO-L476RG Mini-B USB cable AKI_BIN_for_NucleoL476RG RHFAD128_GUI EVAL-RHFAD128V2 Operating system STSW-LINK009

Main components STM32 Nucleo development board With USB data support Software for Nucleo RHFAD graphical user interface RHFAD128 evaluation board Windows OS SW for Nucleo connection

Hardware configuration
RHFAD128 (EVAL-RHFAD128V2)

Figure 1. EVAL-RHFAD128V2

UM3165
Getting started

UM3165 - Rev 1

page 2/14

UM3165
Software configuration
Connect the EVAL-RHFAD128V2 to the Nucleo using the following pinout.
Figure 2. SPI connectors on the EVAL-RHFAD128V2 and the pinout for the connection to the Nucleo

1.3
1.3.1

Software configuration
Nucleo connection 1 - Connect the NUCLEO-L746RG to the laptop using a Mini-B USB cable:
Figure 3. NUCLEO-L476RG used to run the GUI

2 - Please make sure that STLINK is installed and up to date:
UM3165 - Rev 1

page 3/14

Figure 4. STLINK must be installed

UM3165
Software configuration

3 - Launch the RHFAD128_GUI a. Unzip the zipped folder RHFAD128_GUI.zip
Figure 5. There are two documents: RHFAD128_GUI folder containing the RHFAD128_GUI.exe to launch on the laptop - AKI_Bin_for_NucleoL476RG.bin to upload in the Nucleo

4 - Upload the binary into the STM32 Nucleo board

Connect the Nucleo board to the PC using a USB Mini-B cable, drag and drop the binary file to the Nucleo board (NODE_L476RG)

·

use the binary file: AKI_Bin_for_NUCLEOL476RG.bin

Figure 6. This file must be uploaded in the Nucleo

UM3165 - Rev 1

page 4/14

2

Use of the GUI

In the RHFAD128_GUI folder, click on the RHFAD128_GUI.exe file to open the GUI. The following window must appear.

Figure 7. Device selection window

UM3165
Use of the GUI

UM3165 - Rev 1

page 5/14

Figure 8. RHFAD128_GUI interface

UM3165
Use of the GUI

Table 2. SPI speed used by the GUI to communicate with the RHFAD128

Product RHFAD128

SPI speed used by the GUI 500 Msps

UM3165 - Rev 1

page 6/14

3

Troubleshooting

3.1

Device not found

Figure 9. Device not found window

UM3165
Troubleshooting

Issue:

·

The Nucleo board is not detected

Resolution:

·

Please connect the appropriate Nucleo board

·

Be sure that STLINK is installed and up to date

·

It is also better to have only one Nucleo board connected to the computer

·

Then click on "OK".

UM3165 - Rev 1

page 7/14

3.2

Connection issue

Figure 10. Connection issue message

UM3165
Connection issue

Issue:

·

In case of unwanted disconnection or a problem in reading the device, the message "Connection issue"

appears in the Single read mode communication box.

Resolution:

·

Close the GUI and disconnect/reconnect the Nucleo board and restart the GUI

·

If the problem persists, check if the board is correctly connected.

UM3165 - Rev 1

page 8/14

4

List of acronyms

Term GUI

Table 3. List of acronyms Meaning
Graphical user interface

UM3165
List of acronyms

UM3165 - Rev 1

page 9/14

Revision history
Date 29-May-2023

Table 4. Document revision history

Version 1

Initial release.

Changes

UM3165

UM3165 - Rev 1

page 10/14

UM3165
Contents
Contents
1 Getting started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 1.1 System requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1.2 Hardware configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.2.1 RHFAD128 (EVAL-RHFAD128V2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1.3 Software configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.3.1 Nucleo connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2 Use of the GUI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 3 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
3.1 Device not found . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 3.2 Connection issue. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 4 List of acronyms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

UM3165 - Rev 1

page 11/14

UM3165
List of tables

List of tables

Table 1. Table 2. Table 3. Table 4.

System requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 SPI speed used by the GUI to communicate with the RHFAD128 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 List of acronyms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Document revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

UM3165 - Rev 1

page 12/14

UM3165
List of figures

List of figures

Figure 1. Figure 2. Figure 3. Figure 4. Figure 5.
Figure 6. Figure 7. Figure 8. Figure 9. Figure 10.

EVAL-RHFAD128V2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 SPI connectors on the EVAL-RHFAD128V2 and the pinout for the connection to the Nucleo. . . . . . . . . . . . . . . 3 NUCLEO-L476RG used to run the GUI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 STLINK must be installed. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 There are two documents: RHFAD128_GUI folder containing the RHFAD128_GUI.exe to launch on the laptop AKI_Bin_for_NucleoL476RG.bin to upload in the Nucleo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 This file must be uploaded in the Nucleo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Device selection window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 RHFAD128_GUI interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Device not found window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Connection issue message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

UM3165 - Rev 1

page 13/14

UM3165
IMPORTANT NOTICE ­ READ CAREFULLY STMicroelectronics NV and its subsidiaries ("ST") reserve the right to make changes, corrections, enhancements, modifications, and improvements to ST products and/or to this document at any time without notice. Purchasers should obtain the latest relevant information on ST products before placing orders. ST products are sold pursuant to ST's terms and conditions of sale in place at the time of order acknowledgment. Purchasers are solely responsible for the choice, selection, and use of ST products and ST assumes no liability for application assistance or the design of purchasers' products. No license, express or implied, to any intellectual property right is granted by ST herein. Resale of ST products with provisions different from the information set forth herein shall void any warranty granted by ST for such product. ST and the ST logo are trademarks of ST. For additional information about ST trademarks, refer to www.st.com/trademarks. All other product or service names are the property of their respective owners. Information in this document supersedes and replaces information previously supplied in any prior versions of this document.
© 2023 STMicroelectronics ­ All rights reserved

UM3165 - Rev 1

page 14/14



References

C2 v20.4.0000 build 240 - c2 rendition config : Techlit Active Antenna House PDF Output Library 7.2.1732; modified using iText 2.1.7 by 1T3XT