Classic Thermapen® Operating Instructions

Congratulations! The Classic Thermapen is a precision thermometer used for many applications including cooking. With proper care, it will offer accurate measurements for many years. The Classic Thermapen is splash-proof but should not be immersed.

Instrument Operation

The instrument is switched on by unfolding the thermocouple probe until the display comes on. Conversely, the instrument is turned off by folding the probe away and lightly pressing the tip into the rubber probe retainer located at the bottom rear of the instrument. It is recommended to store the probe when not in use.

Caution: Do not force the probe further than 180° or damage to the rotating hub may occur.

The micro-thermocouple sensor is located at the tip of the probe shaft. Minimum immersion is only 1/8" (3 mm). For best results, immerse or penetrate the probe into the food item so the probe tip is in the place you want to measure. In food, this should normally be the thickest part.

Minimum immersion: 1/8"

Sensor location

Probe Tip

The Classic Thermapen will read to within 1°F of the final temperature of an ice bath within three seconds. Reading times in other foods may vary slightly.

Caution: Do not immerse the probe all the way to the plastic rotating hub. Avoid getting flour, moisture, or oil on the hub itself. Although there is an O-ring seal, oils will work their way past the seal and accumulate inside the hub and may cause failure. The probe tip is sharp. Use caution to avoid injury. Do not “stab” the material to be measured. Use steady force to penetrate meats or semi-solids. Avoid bone. Do not lift or flip heavy meats with the probe tip. The probe shaft is hollow and contains a sensor. If bent, it may fail.

Instrument Configuration

You can personalize your Classic Thermapen by changing several factory default settings, including the temperature display units from °F to °C, changing the temperature display resolution from 1° to 0.1°, and disabling the auto-off feature. To reconfigure these settings, open the battery compartment (see Replacing the Batteries section for instructions on opening the battery compartment) and, using a bent paper clip, change the switch bank settings as instructed below.

Switch bank, Trim adjust, CR2032 battery, Switch (factory default shown)

Switch 1 - Units

Changes the instrument's display units between (°F) Fahrenheit and (°C) Celsius. The factory default is °F or switch set farthest from batteries. To change to °C, move the switch to the position closest to the batteries.

Switch 2 – Resolution

Changes the instrument's display resolution between 1°(F or C) and 0.1°(F or C). The factory default is 1º resolution or switch set farthest from the batteries. To change to 0.1° resolution, move the switch to the position closest to the batteries.

Switch 3 – Auto-Off

Enables or disables the auto-off function. If the auto-off function is enabled (factory default), the unit will automatically turn off after 10 minutes to preserve battery life. If disabled, the unit will remain on until the probe is folded away and turned off by the user. The factory default is auto-off enabled or switch set closest to the batteries. To disable the auto-off function, move the switch to the position farthest from the batteries.

Switch 4 – Trim Adjust

If the Thermapen is within specification, ThermoWorks does not recommend using the Trim Adjust. It should not be needed in normal use. This mode allows the user to set an offset that will add or subtract up to 3.6°F (2.0°C) to all readings of the Thermapen. It can therefore be used to tune the calibration. For detailed instructions, visit www.thermoworks.com.

Instructions to use the Trim Adjust to tune your Thermapen calibration are downloadable from the Classic Thermapen webpage. You should not need to do this under normal use. A complete factory re-calibration, including a certificate, is also available from ThermoWorks for a fee.

Batteries

Each unit includes two pre-installed CR2032 (3V) coin cell batteries located inside the sealed battery compartment. An illuminated battery symbol ? indicates that the battery should be replaced soon. The instrument will continue to measure accurately, but it is recommended to replace the batteries immediately. Once the battery is too low to display readings, the display will be replaced with ‘Flat' then ‘Bat' and then shut down. To continue using the instrument, replace the batteries.

Replacing the Batteries

The batteries are pre-installed on your new Thermapen and should last up to 1,500 hours. Should you need to replace the batteries, remove the battery cover with a coin (a U.S. quarter works best). The battery cover may be tight in order to maintain the Thermapen's splash resistance. Using firm but even downward pressure, rotate the battery cover only to the open position. Lift the cover from the hole with a fingernail. Place both batteries with the positive side up, making sure that the clip snaps over the batteries to hold them in place. Replace the battery cover.

Rotate to open, Lift cover off, Do not force past here, OPEN, Battery Cover, Battery clip, CR2032 3V

Cleaning and Maintenance

To avoid potential bacteria growth and cross-contamination, wipe the probe after each use and regularly clean the entire Thermapen body. Oils and grease should be wiped off the body and the rotating hub. ThermoWorks recommends sanitizing wipes or a damp paper towel with an anti-microbial cleaning solution. DO NOT IMMERSE THE THERMAPEN. The built-in seals will protect the Thermapen from incidental moisture, but due to the folding probe, the Thermapen should not be submerged. Protect the plastic body from high temperatures. DO NOT LEAVE THE THERMAPEN IN AN OVEN OR ON A HOT SURFACE.

Warning: IPA and other solvents may cause damage to the case and screen of this instrument.

Error Messages

For all other error messages, contact ThermoWorks' Technical Support at 1-800-393-6434 or techsupport@thermoworks.com.

What is NSF Certification?

The NSF Mark indicates that the design, materials, production process, and quality controls used in the production of the Classic Thermapen have been verified and certified for food safety by NSF International, an independent standards organization.

Biomaster

Biomaster is a silver-based antimicrobial additive that is molded directly into the plastic housing, becoming an integral part of the product to prevent bacteria growth on its surface. The controlled release of the active ingredient provides maximum antimicrobial protection for the life of the product. When bacteria come into contact with a Biomaster-protected surface, the silver ions prevent them from growing, producing energy, or replicating, therefore they die, inhibiting degradation, discoloration, or odors. Biomaster is an additional line of defense between cleanings.*

NIST-traceable Calibration Certificate

Your calibration certificate is a document showing that your Classic Thermapen is in compliance with key industrial regulations and that its performance meets certain key standards for high performance. This means that your Classic Thermapen was tested in the ThermoWorks calibration lab, and those measurements taken are traceable by an unbroken, documented chain of calibrations to the National Institute of Standards and Technology (NIST).

Repair Services

ThermoWorks offers a full repair service for Thermapens damaged for any reason. Contact technical support at 1-800-393-6434 or email techsupport@thermoworks.com.

Additional Technical Information

For more information on using the Thermapen, consult the 20-page Guidebook included and visit ThermoWorks' blog and Help Center for helpful tips and videos at www.thermoworks.com/blog and help.thermoworks.com.

Product Warranty

This instrument carries a two-year warranty against defects in either components or workmanship. During this period, products that prove to be defective will, at the discretion of ThermoWorks, be either repaired or replaced without charge. This warranty does not apply to probes, where a six-month period is offered. Full details of liability are available within ThermoWorks' Terms & Conditions of Sale at www.thermoworks.com/product-warranty.

Thermapen Accessories

Available at www.thermoworks.com:

Models: Classic Thermapen, thermometer, 830-110-LX, 830-001, 10203, 830-260, 830-265

File Info : application/pdf, 4 Pages, 349.55KB

PDF preview unavailable. Download the PDF instead.

classic thermapen operating instructions

References

Adobe PDF Library 15.0 Adobe InDesign 16.0 (Macintosh)

Related Documents

Preview Thermapen ONE Operating Instructions
Operating instructions for the Thermapen ONE thermometer, covering instrument operation, configuration, battery replacement, cleaning, maintenance, error messages, NSF certification, Biomaster technology, NIST traceability, repair services, and available accessories.
Preview Thermapen ONE Precision Thermometer: Operating Instructions & Guide
Comprehensive operating instructions, configuration guide, and maintenance information for the ThermoWorks Thermapen ONE precision thermometer, featuring one-second response time and high accuracy for cooking and other applications.
Preview Thermapen ONE Operating Instructions & Guide | ThermoWorks
Comprehensive operating instructions, configuration, maintenance, and warranty information for the ThermoWorks Thermapen ONE digital thermometer. Learn about its features, calibration, and accessories.
Preview ThermoWorks Pro-Surface & Air Thermapen Operating Instructions and Specifications
Comprehensive operating instructions, specifications, and warranty information for the ThermoWorks Pro-Surface and Air Thermapen thermometers. Includes setup, usage, cleaning, battery replacement, error messages, and measurement recommendations.
Preview EXEC™ Digital Thermometer Operating Instructions & Temperature Guide | ThermoWorks
Comprehensive operating instructions and temperature charts for the ThermoWorks EXEC™ digital thermometer. Learn how to use, care for, and calibrate your thermometer, plus find essential cooking temperatures for meats, candy, and more.
Preview ThermoPop 2 Operating Instructions and Food Temperature Guide | ThermoWorks
Comprehensive operating instructions for the ThermoPop 2 digital thermometer by ThermoWorks, featuring quick response, auto-rotating display, and detailed food safety and cooking temperature charts for meats, water, and candy.
Preview OutWard™ Digital Thermometer Operating Instructions and Temperature Guide | ThermoWorks
Comprehensive operating instructions and temperature reference guide for the ThermoWorks OutWard™ digital thermometer, featuring accuracy, IP67 rating, and detailed cooking temperature charts.
Preview Thermapen Blue Digital Thermometer Operating Instructions
Comprehensive operating instructions for the ThermoWorks Thermapen Blue digital thermometer, detailing specifications, features, usage, care, warranty, and regulatory compliance.