Important: Read all instructions prior to installation.
Dimmable LED Panel Light
Dimensional Drawings
23.75in 603.25mm

47.75in 1212.85mm

3.50in 88.90mm

9.08in 230.70mm

23.75in 603.25mm

9.08in 230.70mm
3.50in 88.90mm

23.75in 603.25mm
Rev Date: V2 03/16/2021

User Manual
LPD6 Series
0.39in 9.91mm
3/4 INCH CONDUIT KNOCKOUT
1.35in 34.29mm LPD6-xK24-50-S
3/4 INCH CONDUIT KNOCK OUT
0.39in 9.91mm
0.39in 9.91mm LPD6-xK22-40-S

Dimmable LED Panel Light
LPD6 Series
User Manual
LPD6-40K24-50-S
Rev Date: V2 03/16/2021

Important: Read all instructions prior to installation.
Dimmable LED Panel Light

User Manual
LPD6 Series

Included Parts 1 - LED panel Light

Recommended Accessories

· 0­10V Slide Dimmer (F019) · 0­10V Knob Dimmer (A019)

Specifications

Model Operating Voltage Rated Power Consumption Current Draw Dimmable Operating Temperature Product Weight IP Rating

LPD6-xK22-40-S

LPD6-xK24-50-S

100­277 VAC

40 W

50 W

333 mA (0.33 A)@120 VAC 417 mA (0.42 A)@120 VAC

0­10 V

-4°­113° F(-20°­45° C)

6 lb (2.7 kg)

12.35 lb (5.6 kg)

IP20

Safety Information

· Product should be installed by a certified electrician in accordance with applicable national, state, and local building and electrical codes.
· To reduce the risk of electric shock, ensure that the main power source and circuit breakers are switched off before performing any installation or wiring procedures.
· Avoid looking directly into the light when illuminated. · Failure to properly support the fixture may result in damage or injury, for
which the manufacturer does not assume responsibility. A safety cable is not included, but it is recommended that one be connected to grid clip during installation.

Wiring Diagram

Neutral (white) Line (black)

Ground (green)

Dim- (gray) Dim+ (purple)

Drop Ceiling Installation

1. Turn supply power to circuit off. If installing as a retrofit, remove existing fixture. 2. Open driver box and remove knockout(s) for wiring. Make electrical connections
using wiring diagram. Once complete, resecure driver box cover.

FIG 1

Firmly bend Safety Tabs up and out

Safety Tab

3. Bend out safety tab to be vertical, then upper portion out 90 degrees. It is recommended that a safety cable (included) be installed to anchor the fixture as well.
4. Lay fixture into T-grid.

FIG 2

Fixture

Safet Tab

T-Grid

Driver Box

Note: Tabs should secure light in T-grid while still allowing reinstallation of adjacent ceiling tiles.