Instruction Manual for emotion models including: motion cross 900 Cross Trainer Fitness, motion cross 900, Cross Trainer Fitness, Trainer Fitness, Fitness

Bedienungsanweisung

, docId:1C97D1841CD1425D8348C0967C1C57A4

Helmut Klein

Instructions for use

Instruction Manual Elliptical Trainer 900 / 900 med Version 1.3 25.01.2023 Page 5 from 14 Warning: The heart rate monitoring system is susceptible to failure due to the system.Excessive exercise can lead to dangerous injuries or death. If you feel unwell, stop exercising immediately and consult your doctor or


File Info : application/pdf, 14 Pages, 1.08MB

PDF preview unavailable. Download the PDF instead.

gb cross 900 v1.3
Instructions for use
for
Elliptical trainer of the motion cardio line 900 & motion cardio line 900 med

motion cross 900 motion cross 900 med

Instruction manual Pedal ergometer 900 / 900 med Page 1 from 17

Version 1.3 25.01.2023

Content
1. General ..................................................................................................................................................................... 2 2. Classification of the devices ..................................................................................................................................... 2 3. Safety instructions .................................................................................................................................................... 3
Safe installation of the equipment ........................................................................................................................... 3 Safe training.............................................................................................................................................................. 4 Indications and contraindications ............................................................................................................................ 5 4. Operating the display ............................................................................................................................................... 6 Overview display/key functions ............................................................................................................................... 6 Programme selection................................................................................................................................................ 7 Pulse systems............................................................................................................................................................ 7 Inductive charging (optional).................................................................................................................................... 8 5. Care, maintenance and servicing ............................................................................................................................. 8 Fault detection (malfunction) guide ....................................................................................................................... 11 Maintenance instructions for the operator............................................................................................................ 11 Maintenance by authorised specialist.................................................................................................................... 11 Calibration/Maintenance ....................................................................................................................................... 12 6. Technical data*....................................................................................................................................................... 12 7. Disposal................................................................................................................................................................... 12 8. Warranty................................................................................................................................................................. 13

Instruction Manual Elliptical Trainer 900 / 900 med Page 1 from 14

Version 1.3 25.01.2023

1. General
Read this user manual with all safety instructions and warnings carefully before using the training equipment for the first time to ensure safe and proper use. Keep this document for future reference and give it to others if you pass on the equipment.
The purpose of the equipment is cardiopulmonary training and the reproducible loading of the body, e.g. for diagnostic and therapeutic measures. The equipment is mainly used by users in cardiology, physiotherapy, sports medicine and in the home. Another application is the use to build up and strengthen skeletal muscles, as well as to increase mobility in the joints affected during training. The equipment enables reproducible physical loading of the human body and the cardiovascular system for the purposes of prevention, rehabilitation and diagnosis.
Text with a grey background indicates text sections that deal exclusively with equipment features of the fitness line.
2. Classification of the devices
 The devices of the cardio line 900 med are medical products according to the directive 93/42 EWG, classified in class IIa. In the control range of the brake, the display accuracy is +/- 5% or +/- 3 watts for loads below 50 watts.
 The devices of the cardio line 900 comply with the standard DIN EN ISO 20957-1 and DIN EN ISO 20957-5; application class S (commercial use/studio) and H (home use) of accuracy class A +/- 10 % and are designed exclusively for the fitness and sports sector.
Only 1 person can exercise with the equipment at a time; the maximum user weight according to the type plate must not be exceeded.

Instruction Manual Elliptical Trainer 900 / 900 med Page 2 from 14

Version 1.3 25.01.2023

3. Safety instructions
Safe installation of the equipment
Movable handles for the whole body workout
Position name plate
Pedals

Display for showing training data and setting the gear
Rigid hand grips for support during lower limb exercises

Adjustable feet for levelling
Fig.1: Device view motion cross 900 & motion cross 900 med with designation of the essential elements

Instruction Manual Elliptical Trainer 900 / 900 med Page 3 from 14

Version 1.3 25.01.2023



Place the unit on a firm, horizontal, level and non-slip surface and level the unit with the

adjusting screws so that it does not wobble.



The free area around the unit must be at least 1 m larger than the movement range of

the unit to ensure safe access and egress from the unit even in emergencies. However, the

safety clearances may overlap (see picture).



Only place the appliance in dry rooms at ,

.



Make sure that there is no electromagnetic radiation, e.g. from radio antennas, radiating

fluorescent tubes, etc., as these can affect the pulse measurement.

 The underside of the frame must always be free for sufficient ventilation.

 All the units mentioned here are mains-independent. They generate the power themselves during operation or are

supplied with power during programming by the standard built-in capacitor. The capacitor is charged by training and

has a life span of > 20000 cycles.

 Attention: Please always follow the instructions for care, maintenance and servicing in chapter 5 of this manual.

Safe training
 Before starting training, the fitness for training should be checked by an authorised person, e.g. a doctor. Please note the point "Indications and contraindications".
 Note that excessive exercise can be harmful.  If nausea or dizziness occurs, stop training immediately and consult a doctor.  Training on the equipment is only permitted with intact skin.
 When training, tight-fitting, lightweight sports clothing is preferable so that it cannot get caught in parts of the device during training. Always wear suitable sports shoes for a secure footing on the pedals.
 Before starting the training, check the unit for safe standing, defective parts or possible manipulations. If you find any defects or are not sure, ask the supervisor before starting the training.
 Before starting training, make sure that nobody is near the moving parts in order to avoid endangering third parties. In particular, unsupervised children must be kept away from the equipment.
 The crosstrainer does not have a free wheel. Therefore, the exercise cannot be stopped abruptly by the user. Therefore, use the pause/stop button on the display or let the movement slow down.
 The pause/stop button is always active as a safety function and brakes the movement immediately when the button is pressed. In addition, the unit has a speed limit, which is set to 80 rpm by default. If you try to go above 80 rpm, the speed is pushed back below the limit by means of a brake intervention. If you would like to adjust the limit, please contact our service department.
 In order to train biomechanically correctly, no adjustments need to be made to the device. It is only necessary to ensure that the feet are completely on the pedals and that the moving handles are gripped at about shoulder height. Avoid hunched backs or bar cross positions when exercising and never keep your knee and elbow joints in an unbent position (0=position).
 For training the lower extremity only, use the rigid handles. Please note that the movable handles swing and could injure you.

Instruction Manual Elliptical Trainer 900 / 900 med Page 4 from 14

Version 1.3 25.01.2023



Warning: The heart rate monitoring system is susceptible to failure due to the system. Excessive exercise can

lead to dangerous injuries or death. If you feel unwell, stop exercising immediately and consult your doctor or

therapist.



Warning: The unit may only be operated with a housing and in dry rooms.



Warning for optional power connection: Use only approved power supply units that have been tested

according to IEC 60601-1 and approved by the unit manufacturer. Make sure that the power supply is installed in

such a way that it is difficult to disconnect it (e.g. by means of floor tanks, installation under the unit or cable ducts,

position of the power supply in areas that are difficult to access).



Warning: If the medical device is modified, appropriate investigations and tests must be carried out to ensure

continued safe use. Do not modify the device without the manufacturer's permission.

Indications and contraindications Before starting training, please consult a doctor or therapist to ensure fitness for training.

Example indications  Mobility of the musculoskeletal system  Strengthening the musculature  Strengthening the cardiovascular system
Example contraindications
 Cardiovascular diseases  Pain of the musculoskeletal system  During the training:
o Chest pain o Malaise o Nausea o Dizziness o Shortness of breath
Ask the doctor if you are taking medication.

Instruction Manual Elliptical Trainer 900 / 900 med Page 5 from 14

Version 1.3 25.01.2023

4. Operating the display
Various training and test programmes enable individual and varied training with the motion cardio line 900 and motion cardio line 900 med machines.

Basic equipment incl. programme package

cross 900 / 900 med
Quickstart, timed training, pulse training
Quickstart Qualifying Pulse training + 7 more programmes + 4 motion balance programmes

Overview display/key functions

Home Button

PAUSE

COOL PLAY

Fig. 2: Monitor view, explaining the button functions, actual view may vary in colour, button assignment is the same.

Explanation of the buttons:  The Home button is a physical button below the display glass. It is pressed to enter the main menu. Pressing the HOME button for a long time (at least 6 seconds) resets the monitor electronics.  Press the PAUSE button ( ) to pause the training.  Pressing the PLAY button ( ) starts or resumes the training.  The COOL button ( ) stops the training immediately. A summary of the training results is immediately generated, displayed and, if necessary, sent to a compatible training control software.  Use the "+" key or "-" key to increase or decrease the parameters or power values to be set.  Use the arrow keys to navigate through the corresponding menus and confirm values or settings.
 Swipe/swipe gestures navigate through the programme selection.

Depending on the programme, some of the following parameters are displayed:

 Programme name.

 Time: Training time completed or remaining.

 Pulse: Heart rate indicator, when using a compatible pulse transmitter belt. The pulse indicator display shows the current pulse range for programmes with target or maximum pulse. The profile indicator in the display shows the

progression of the intensity range during training.

 Watt: Power is displayed in watts. In parallel, the intensity is clarified via a graphic display in the profile.

 km/h: Fictitious speed is displayed in km/h.

 Speed: Pedal revolutions per minute.

 L/R (not with body 900/900 med): The force ratio of the left and right leg is displayed here in %.

 HRV: Heart rate variability is displayed via the RMSSD value (requires

H10 sensor).

Instruction Manual Elliptical Trainer 900 / 900 med Page 6 from 14

Version 1.3 25.01.2023

 resp: Breathing rate (requires

H10 sensor)

 km: Added or remaining distance. The display is in metres; from 1000 m in 10 m steps (1.00 km).  K-Cal: Added or remaining calorie consumption.

 Level: Intensity level 1 - 21.

 : If the parameters are completed with this symbol, they are average values.

Results After completion of a training programme or premature termination via COOL ( ), the results are displayed in the monitor and a 3 minute cool-down takes place. This can be cancelled via the HOME button. Some of the values are averaged (Watt, Km/h, RPM, Pulse, Altitude/ min), some are cumulated (Km, K-Cal, Time, Altitude). The average values are marked with the symbol Ø. These results make it possible to monitor personal performance development and thus serve as motivation.
Programme selection The desired training programme can be selected in the main menu by tapping the corresponding symbol. You will then be taken to the configuration page where you can set the corresponding training parameters. Press the PLAY button ( ) to confirm your entry and start the training. You can return to the main menu via the home icon or the home button.

Fig. 3: Programme selection and configuration for manual training.

Pulse systems

The devices of the motion cardio line 900 and the motion cardio line 900 med have the original

pulse system,

in which the signal acquisition is carried out by means of a chest strap as standard. This enables individual training in

various programmes. The wireless data transmission to the display electronics is coded (either via 5kHz or

).

The new

"Auto-Pairing" technology is based on secure and interference-free data transmission via Bluetooth.

This technology requires the use of the H10 or H9 transmitters. Other parameters, such as HRV and respiratory rate,

are also transmitted to the monitor via the

connection.

If the old transmitters are used, e.g. T31coded, there is downward compatibility. It should be noted, however, that there

may be interference with the signal transmission via the 5 kHz technology.

The colour of the flashing heart symbol gives an indication of the technology used.

light blue=Bluetooth green=5kHz

ANT+ The devices of the motion cardio line 900 and motion cardio line 900 med allow, in addition to the transmission of the

heart rate via 5kHz/

, an optional data transmission via . The performance package is required for this.

By default, Polar 5kHz/

technology is activated. To activate transmission via , the "ANT+" switch in the

info box ( ) must be switched on (marked yellow here). After that, a connection to a transmitter unit that sends the

heart rate via can be established. A dark blue flashing heart symbol confirms the heart rate transmission via .

Instruction Manual Elliptical Trainer 900 / 900 med Page 7 from 14

Version 1.3 25.01.2023

Fig. 4: Activation of ANT+ for heart rate transmission
Safety instruction according to DIN EN ISO 20957
Warning. Heart rate monitoring systems can be inaccurate. Excessive exercise can cause serious damage to health or death. Stop exercising immediately if you feel dizzy or weak.
Inductive charging (optional) An optional inductive charging module can be activated on all motion cardio line 900 and motion cardio line 900 med
units via the "connect package". This allows mobile devices that comply with the Qi standard ( ) to be charged
without contact. Wearers of pacemakers or implanted defibrillators (ICDs) are advised to keep a minimum distance of 10 cm from the charging coil.

5. Care, maintenance and servicing
All cardio equipment from emotion fitness is durable and requires little maintenance to function as training equipment for a long time. However, it is imperative that the necessary care is carried out conscientiously.

Warning: The unit may only be opened by an authorised specialist

Symbols and meaning

Safety sign

Reference ISO 7010-P017

Title Pushing prohibited

ISO 7010-W012 ISO 7000-1641

Warning, Electricity Instructions for use

DIN EN ISO 20957

Safety Notice Heart Rate Monitoring

ISO 7000-3082

Manufacturer

Instruction Manual Elliptical Trainer 900 / 900 med Page 8 from 14

Version 1.3 25.01.2023

ISO 7000-2497 ISO 7000-0632

Date of manufacture Temperature limit

ISO 7000-2620

Air humidity, limitation

ISO 7010-W001

General warning sign

ISO 7010-M002

Follow the operating instructions

IEC 60417-5840 ISO 15233

Type B applied part (concerns saddle, pedals and handlebars)
Medical device

The safety level of the units can only be maintained if the units are regularly checked for damage and wear. Defective parts must be replaced immediately and the unit must be shut down until it is repaired.

Instruction Manual Elliptical Trainer 900 / 900 med Page 9 from 14

Version 1.3 25.01.2023

Fault diagnosis
The following error messages may occur. If the error is displayed repeatedly, the measures listed below can help. If these do not lead to success, the manufacturer and, if necessary, the software manufacturer should be contacted.

Error message "RFID Error"
"Heart Sensor?" "USB Problem"
"Radio Problem"
"NDEF err: length"
"NDEF err: verify" Missing value: XX
(XX=number) Value XX out of Range
(XX=number)

Measure/s

Affected

unit types

 RFID number, i.e. number on transponder is too short or too long.

All ergometers

 An error occurred while reading the RFID number.  use a different transponder

The monitor wants to start a programme that

All

requires a heart rate sensor to be worn. If no sensor ergometers

is found, this message is displayed.

The radio message was successfully sent from the

All

radio module of the monitor to the radio module of the ergometers

PC (i.e. the receiver module acknowledged receipt of

the message), but there was no response from the

PC after the specified time period:

 Restart the PC and plug the USB dongle into the

PC again. If necessary, restart the software service.

 The unit does not receive a response from the USB dongle.

All ergometers

Attention! This error message can also be displayed

if the message sent from the dongle to the monitor is

faulty (e.g. wrong format or message incomplete).

 Restart the PC and plug the USB dongle into the

PC again. If necessary, restart the software service.

 The message found on the NFC tag (i.e. the message transmitted from the smartphone) is too

All ergometers

long.

 Contact the software manufacturer or device

manufacturer

 The NFC tag could not be accessed. This is an authorisation problem when accessing the NFC tag

All ergometers

through the monitor using the super password.

 Contact the manufacturer or software producer

 A necessary setting parameter was not sent to the ergometer by the PC software Contact the

All ergometers

manufacturer or software producer.

 A necessary setting parameter was sent outside the All permissible range from the PC software to the unit ergometers

contact the manufacturer or software producer

Instruction Manual Elliptical Trainer 900 / 900 med Page 10 from 14

Version 1.3 25.01.2023

Fault detection (malfunction) guide If any faults occur on the equipment that you cannot classify, please contact emotion fitness GmbH & Co.KG. For each error message, you should have the serial number and model type of the defective device ready, as this could be important in order to be able to make the correct diagnosis and, above all, to provide the appropriate replacement parts for you!
Maintenance instructions for the operator Ideally, visually inspect the unit before each use, but at least daily, and pay particular attention to defective parts, loose connections and atypical noises.
The following checks must be carried out at least every 6 months:  Visually inspect all visible joints, as well as welds.  Clean the unit thoroughly.  Check all screw connections for tightness.  Check the integrity and strength of the pedals and cranks.
Generally speaking:  Clean the plastic casing and frame parts regularly as required with a damp cloth and mild soap, then wipe dry again.  The use of spray bottles with cleaning agents is not permitted; it has been shown that the units never become dry in inaccessible places. Rust infestation cannot be ruled out by this procedure.  Make sure that no liquid gets into the monitor housing,  For any necessary disinfection of the devices, please use only mikrozid® sensitive wipes disinfectant wipes (http://www.schuelke.com/).  The monitor display may show a capacitor voltage that is too low, at which a function without braking current cannot be safely guaranteed. You can recharge the capacitor by pedalling with a higher load or a power supply unit approved by the device manufacturer.  Check the housing fixings for tightness.  We recommend a regular visual inspection of all parts of the unit, especially screws, welds and other fixings.  Check that the feet of the appliance are firmly seated.  Only use original spare parts - contact us for this.
Maintenance by authorised specialist In case of problems with the device that you cannot solve yourself in a simple way, always contact the emotion fitness
service. The authorised service will help you quickly and competently or provide you with instructions.

Instruction Manual Elliptical Trainer 900 / 900 med Page 11 from 14

Version 1.3 25.01.2023

Calibration/Maintenance
On elliptical and stair-climbing machines (cross and stair), no MTK is required by law for the operator. This is because the body weight has an influence on the resulting power on these machines. emotion fitness GmbH & Co. KG offers to calibrate the brake power on request. In addition, we recommend maintenance with inspection of the safety-relevant components (STÜ) by authorised employees/partners every 12 months. This section refers to the legal situation in Germany. Please check the applicable laws for operating medical devices in your country.
Devices with the suffix "med" are in accordance with the Medical Devices Directive 93/42/EEC. They thus bear the CE mark and the number of the notified body.
The distributor/operator is responsible for carrying out maintenance, servicing and calibration, as well as possible inspections in accordance with applicable regional laws and regulations at the location of the equipment! Your local authorised dealer can also provide further information.

6. Technical data*

Device type
motion cross 900 motion cross 900 med

Dimensions (L/W/H) 200 cm x 65 cm x 169 cm

Weight 101 kg

Max. user weight

Safe workload

150 kg; boosted: 200 kg 251 kg; boosted: 301 kg

Resistance system: Mains-independent braking system Power range: speed-independent: 100-500 watts (optionally 100-950 watts); speed-dependent: 100-1,000 watts Freewheel: not available The following EU directives are fulfilled:
2001/95/EC General Product Safety Directive 93/42/EEC Medical Devices Directive Class IIa (only fulfilled for devices with the suffix med) 2014/30EU EMC Directive The following standards were used: DIN EN ISO 20957-1 Accuracy class A, use class SH; DIN EN ISO 20957-5; DIN EN 60601-1:2013; DIN EN 60601-1-2
* Values may vary due to unit changes and options.
We reserve the right to make technical and optical changes as well as printing errors.

7. Disposal
With the conclusion of the purchase contract, it shall be deemed agreed that business customers will dispose of the EU Directive 2002/96/EU on waste electrical and electronic equipment themselves.

Instruction Manual Elliptical Trainer 900 / 900 med Page 12 from 14

Version 1.3 25.01.2023

8. Warranty

This is based on the statutory warranty. emotion fitness GmbH & Co. KG, as the distributor of this product, will provide free service for 12 months on parts and labour for professional users if the proper use and care listed in this user manual can be verified. For a further 12 months, emotion fitness GmbH & Co. KG will provide replacement parts free of charge. The warranty claim expires if the product has been serviced or repaired by unauthorised persons. As soon as a warranty case occurs, you should immediately inform emotion fitness GmbH & Co KG of this in writing or by e-mail. Information about the serial number of the device, the time of purchase, a detailed description of the fault and the source of supply must be provided by the owner of the device. emotion fitness GmbH & Co KG will arrange for a service, but reserves the right to determine the type of service.
The following procedures are conceivable: 1. the service is carried out on site by our service. 2. we send the desired spare part. 3. we will send a replacement unit.
The defective parts shall be returned to us immediately by the customer. Otherwise, the delivered spare parts will be invoiced. If the causes lie outside the scope of the warranty, emotion fitness GmbH & Co. KG reserves the right to charge all repair costs. Some wear parts are not covered by the warranty. These are in particular the saddle, cranks and crank attachment,

pedals, pedal loops, upholstery fabrics and the grip rubber on the handlebar. The legal warranty.

pulse systems come with the

These warranty provisions shall in no way affect the general statutory claims. Our General Terms and Conditions of Delivery, as amended from time to time, can be viewed and downloaded from our website www.emotion-fitness.de.

Thank you for your trust!
Manufacturer emotion fitness GmbH & Co. KG
Trippstadter Str. 68 67691 Hochspeyer, Germany
Tel +49 (0) 6305-71499-0 Fax +49 (0) 6305-71499-111 Internet: www.emotion-fitness.de E-mail: info@emotion-fitness.de
Manufacturer EUDAMED SRN: DE-MF-000016584

Instruction Manual Elliptical Trainer 900 / 900 med Page 13 from 14

Version 1.3 25.01.2023



References

Microsoft Word 2013 Microsoft Word 2013