User Guide for KRAMER models including: KRAMER, VM-3DT, 1 3, HDBT, Distributor
3. EDID SETUP Button. Press to capture the input EDID, force RGB mode or select the default EDID. 4. ACTIVE INPUT LED. Lights green when an HDMI signal is ...
Kramer VM-3DT 1x3 4K60 4:2:0 Long-Reach HDBaseT VM-3DT B&H Photo
File Info : application/pdf, 4 Pages, 757.88KB
DocumentDocumentScan for full manual VM-3DT Quick Start Guide This guide helps you install and use your VM-3DT for the first time. Go to www.kramerav.com/downloads/VM-3DT to download the latest user manual and check if firmware upgrades are available. Step 1: Check what's in the box VM-3DT 1:3 HDBT Distributor 1 Power adapter and cord 1 Quick start guide 4 Rubber feet Step 2: Get to know your VM-3DT # Feature 1 ON LED 2 PROGRAM Mini USB Connector 3 EDID SETUP Button 4 ACTIVE INPUT LED 5 HDBT LINK LEDs IN OUT 6 OUTPUTS CONNECTED LEDs 7 INPUT HDBT Connector 8 HDBT OUT Connectors 9 SETUP 8-way DIP-switches 10 SETUP 4-way DIP-switch 11 5V DC Function Lights green when the unit receives power. Use to send RS-232 commands. Connect to a PC to perform firmware upgrades (via K-Upload) and work with the EDID Designer. K-Upload and EDID Designer can be downloaded from our Web site at:www.kramerav.com/manual/EDID Designer. To use the mini USB port, you need to download and the Kramer USB driver from our Web site at: www.kramerav.com/support/product_downloads.asp and install it. Press to capture the input EDID, force RGB mode or select the default EDID. Lights green when an HDMI signal is embedded on the HDBaseT input. Lights green when a link is established with the HDBaseT transmitter. Lights green when a link is established with the HDBaseT receiver (1 to 3). Flashes when a non-HDCP acceptor is connected to the output and the input is HDCP-encrypted (the content is displayed for only a few seconds). Lights green when an acceptor (sink) is detected on the HDBaseT receiver connected to the output (from 1 to 3). Connects to an HDBaseT source, for example VS-44DT. Connect to an HDBaseT acceptor (from 1 to 3), for example TP-580R. Use to set IR (DIP-switches 1-3) and RS-232 (DIP-switches 5-7) command behavior. Always keep all four DIP-switches UP (off). +5V DC connector for powering the unit. VM-3DT Quick Start P/N: 2 9 0 0 - 3 0 0 7 9 6 QS Rev: 2 Step 3: Install the VM-3DT Install VM-3DT using one of the following methods: · Attach the rubber feet and place the unit on a flat surface. · Fasten a bracket (included) on each side of the unit and attach it to a flat surface. For more information go to www.kramerav.com/downloads/VM-3DT. · Mount the unit in a rack using the recommended rack adapter (see www.kramerav.com/product/VM-3DT). Step 4: Connect the inputs and outputs Always switch OFF the power on each device before connecting it to your VM-3DT. For best results, we recommend that you always use Kramer high-performance cables to connect AV equipment to the VM-3DT. HDBT RJ-45 Pinout: Use a straight pin-to-pin cable with RJ-45 connectors. We recommend that for HDBT cables, the ground shielding be connected/soldered to the connector shield. DIP-Switch Setup: To enable/disable IR and RS-232 routing, set the DIP-switches as follows: PIN EIA /TIA 568B PIN Wire Color 1 Orange / White 2 Orange 3 Green / White 4 Blue 5 Blue / White 6 Green 7 Brown / White For optimum range and performance use the recommended Kramer cables available at www.kramerav.com/product/VM-3DT. Out # OUT 1 OUT 2 OUT 3 Note: DIP-switches 4 and 8 are reserved for future use. By default, all DIPswitches are set to OFF (up). IR Routing is enabled when: DIP 1 OFF (up) DIP 2 OFF (up) DIP 3 OFF (up) RS-232 Routing is enabled when: DIP 5 OFF (up) DIP 6 OFF (up) DIP 7 OFF (up) Step 5: Connect the power Connect the power adapter to the VM-3DT and plug the adapter into the mains electricity. Safety Instructions Caution: There are no operator serviceable parts inside the unit. Warning: Use only the Kramer Electronics power supply that is provided with the unit. Warning: Disconnect the power and unplug the unit from the wall before installing. See www.KramerAV.com for updated safety information. Step 6: Operate the VM-3DT Acquire EDID by: · Using the EDID SETUP front panel button. · Using the Kramer EDID Designer PC tool connected to USB. · Manually sending RS-232 serial commands via laptop connected to USB. USB setup for RS-232 communication: RS-232 Baud Rate: 115200 Data Bits: 8 Stop Bits: 1 Parity: None Command Format: ASCII Example (Copy the EDID data from Output 1 to the Input): "#CPEDID 1,1,0<cr> Factory Reset Protocol 3000: #FACTORY command to reset to factory default configuration. VM-3DT supports EDID Designer (via the mini USB port) that can be loaded from our Web site: Kramer EDID Designer. To use the mini USB port, you need to download and the Kramer USB driver from our Web site at: www.kramerav.com/support/product_downloads.asp and install it. Acquiring the EDID via front panel Press the EDID SETUP once to display the current EDID source: OUT 1, OUT 2, OUT 3, or all OUT LEDs flash (default EDID). To acquire an EDID: 1. Press EDID SETUP. the current EDID source is displayed. 2. Press EDID SETUP (a second time) to enter EDID select mode. 3. Press EDID SETUP repeatedly to cycle through the EDID source options. The OUT LEDs flash in the following order: OUT 1 -> OUT 2 -> OUT 3 -> all output LEDs flash (default EDID). Stop pressing EDID SETUP once the required EDID source is reached. 4. Wait a few seconds, until VM-3DT acquires the EDID. When complete, all output LEDS return to normal operation, displaying the present output connection status. If an unconnected output is chosen or the connected EDID cannot be read, the VM-3DT loads the default EDID. Forcing the RGB Mode Normally (the default state), when acquiring the EDID, the device supports any color space that is defined in the acquired EDID parameters. In case of a color space problem, using the Force RGB mode may improve the colors of the image on the display. To: Force the acquired EDID to support only RGB color space: Return to the normal EDID mode: View the current EDID mode: Do the following: Press and hold the EDID button for few seconds until all the output LEDs flash together four times. Continue to acquire the desired EDID. This acquired EDID is then forced to support the RGB color space only. Press and hold the EDID button for few seconds until the output LEDs flash together once. Continue to acquire the desired EDID. Power cycle the unit. All output LEDs will flash together once when in normal EDID mode, and four times when in Force RGB mode. Technical Specifications Input 1 HDBT On a female HDMI connector Outputs 3 HDBT On RJ-45 female connectors Ports 1 USB On a Mini female connector Maximum Extension Range 40m (130ft) At 4K@60Hz (4:2:0) 70m (230ft) At full HD (1080p@60Hz 36bpp) The specs only apply when using Kramer HDBaseT cables. This reach applies to each IN and OUT port separately; the total end-to-end reach is the sum of all ports' reach. Video Max. Resolution 4K@60Hz 4:2:0 Max. Data Rate 10.2Gbps (3.4Gbps per graphic channel) Compliance Supports HDMI 2.0, HDCP 1.4 and HDBaseT 1.0 Control Front Panel EDID SETUP button OUTPUTS CONNECTED, HDBT LINK, ACTIVE INPUT, and ON indication LEDs Rear Panel DIP-switches Power Consumption 5V DC, 3.2A Source 5V DC, 4A Environmental Conditions Operating Temperature 0° to +40°C (32° to 104°F) Storage Temperature -40° to +70°C (-40° to 158°F) Humidity 10% to 90%, RH non-condensing Regulatory Compliance Safety CE, FCC Environmental RoHs, WEEE Enclosure Size Desktop Cooling Fan ventilation General Net Dimensions (W, D, H) 21.5cm x 16.3cm x 4.4cm (8.4" x 6.4" x 1.8") Shipping Dimensions (W, D, H) 35.1cm x 21.2cm x 7.2cm (13.8" x 8.3" x 2.8") Net Weight 0.53kg (1.2lb) approx. Shipping Weight 1.3kg (2.9lb) approx. Accessories Included Power cord and adapter Specifications are subject to change without notice at www.kramerav.com