User Guide for PowerPoint models including: XPG01 Glass Breakage Sensor Mount Guide, XPG01, Glass Breakage Sensor Mount Guide, Breakage Sensor Mount Guide, Sensor Mount Guide, Mount Guide
23 févr. 2024 — The Glass Break Sensor must always be in direct line of sight of all windows to be protected. The Glass. Break Sensor cannot consistently detect glass ...
Glass Breakage Sensor Mount Guide (XPG01) Mount Guide01-SS-2022 1 Glass breakage Sensor Finding a suitable location The Glass Break Sensor must always be in direct line of sight of all windows to be protected. The Glass Break Sensor cannot consistently detect glass breaking around corners or in other rooms. There is no required front, back, up or down orientation. Wall Mount The best wall-mount location is on the opposite wall, assuming the glass to be protected is within the sensor's range and line of sight. The adjoining wall can also be used Ceiling Mount Mount the Glass Break Sensor in a location that has a direct line of sight of the glass to be protected. Since sound travels directionally out from a broken window, a position 7 ft. (2.1 m) into the room provides better detection. To determine the best mounting location, mount the Glass Break Sensor: At least 3.3 ft. (1 m) from the windows being protected and at least 4 ft. (1.2 m) from noise sources such as TVs, speakers, sinks, and doors. In the direct line of sight of the glass to be protected. In a suitable environment: temperature between 14 and 120°F (-10 and 50°C); and humidity between 10 and 90% noncondensing. On a stable surface up to 23 ft. (7.0 m) from the farthest point on the glass surface. Mount Guide01-SS-2022 22 Glass breakage Sensor Recommended Locations and Range The Glass Break Sensor is omni-directional, providing 360° coverage. Coverage is measured from the Glass Break Sensor to the point on the glass farthest from the sensor. The sensor can be mounted as close as 3.3 ft. (1 m) from the glass. The maximum range depends on the type of glass being protected: Armor-coated glass: Mount the Glass Break Sensor no more than 12 ft. (3.6 m) from the glass. Plate, tempered, laminated, and wired glass: Mount the Glass Break Sensor on the ceiling or the opposite or adjoining wall. Maximum range is 23 ft. (7.0 m). [Ceiling Mount] More than 3.3ft(1m) [Wall Mount] 3.3ft(1m) 7ft(2.1 m) Mount Guide01-SS-2022 33 Glass breakage Sensor 3.3ft(1m) More than 4ft(2m) More than 4ft(2m) More than 6.5ft(2m) 3.3ft(1m) More than 6.5ft(2m) Mount Guide01-SS-2022 44 [Noise sources] More than 4ft(1.2m) More than 6.5ft(2m) Glass breakage Sensor 7ft(2.1m) More than 6.5ft(2m) 3.3ft(1m) [Speaker] Mount Guide01-SS-2022 55Microsoft PowerPoint 2013