User Manual for APPA models including: A1, 700020080, A1 Mini AC DC Clamp Meter, Mini AC DC Clamp Meter, DC Clamp Meter, AC Clamp Meter
A1 EN Battery Replacement SPECIFICATIONS 1-1 General Specifications Display Count : 6000 count Overrange Display : ”OL or “-OL” Conversion Rate : 2 times / second Dimensions (W x H x D) : 60 x 147 x 31.5 mm
File Info : application/pdf, 50 Pages, 7.37MB
DocumentDocumentA1 User Manual / / YEAR S LIMITE D WARRAN TY EN Mini AC / DC Clamp Meter TC / SC / JP AC DC RU A1 EN Read First Safety Information Use the Meter only as specified in this manual or the protection by the Meter might be impaired. - Always use proper terminals, switch position and range for measurements. - Verify the Meter's operation by measuring a known voltage. If in doubt, have the Meter serviced. - Do not apply more than the rated voltage, as marked on Meter. - To avoid false readings that can lead to electric shock and injury, replace battery as soon as low battery indicator blinks. - Do not use Meter around explosive gas or vapor. - To reduce the risk of fire or electric shock do not expose this product to rain or moisture. - Individual protective equipment should be used if HAZARDOUS LIVE parts in the installation where measurement is to be carried out could be ACCESSIBLE. Caution Do not expose Meter to extremes in temperature of high humidity. 1 A1 EN Symbols as marked on the Meter and Instruction manual Risk of electric shock See instruction manual DC measurement AC measurement Equipment protected by double or reinforced insulation Battery Earth Conforms to EU directives Application around and removal from hazardous live conductors is permitted Do not discard this product or throw away Maintenance Do not attempt to repair this Clamp Meter. It contains no user-serviceable parts. Repair or servicing should only be performed by qualified personnel. Cleaning Periodically wipe the case with a dry cloth and detergent. Do not use abrasives or solvents. 2 A1 EN Power on/off Auto Power Off Auto Power Off Disable Hold down and press 3 A1 ACA & DCA EN CAT. III 600V with respect to earth for the jaw Barrier for Hand Guard Do not hold the meter across the Barrier Auto ACA&DCA Detection / ACA&DCA Dut to the high sensitivity of the clamp meter, perform DCA Zero in the same direction as measurement to avoid interference by external magnetic field. 4 A1 EN Data Hold The display will flash continuously if the measured signal is larger 50counts than the display reading. However, it cannot detect across the AC and DC Current. DCA ZERO Inrush Current The meter calculates the RMS value for 100ms as detecting a more than 5A current. 5 A1 EN Low Pass Filter The cut-off frequency of the low pass filter is about 160Hz with attenuation characteristic of approx-24db/octave. Backlight on/off Voltsense Do not hold the meter across the Barrier Barrier for Hand Guard The number of dashes displaying on the LCD indicates the electric field intensity. If no indication, voltage could still be present. 6 A1 EN Battery Replacement SPECIFICATIONS 1-1 General Specifications Display Count : 6000 count Overrange Display : "OL or "-OL" Conversion Rate : 2 times / second Dimensions (W x H x D) : 60 x 147 x 31.5 mm Weight : 140 g Power requirement : LR44 Size Button Battery 1.5V x 2 Battery Life : 20 hours. Maximum Conductor Size : 22 mm LVD : EN61010-1, EN61010-2-032 EMC : EN61326-1 Installation category : CAT.III. 600V. CAT Application field I The circuits not connected to mains. II The circuits directly connected to Low voltage installation. III The building installation. IV The source of the Low-voltage installation. 7 A1 EN 1-2 Environmental Conditions Indoor Use. Maximum operating altitude : 2000m (6562ft) Operating temperature : 0°C ~ 30°C, 80%RH 30°C ~ 40°C, 75%RH 40°C ~ 50°C, 45%RH Storage temperature : -20 to +60°C, 0 to 80% RH (no batteries). Temperature coefficient : 0.2 x (Specified accuracy) / °C, < 18°C, > 28°C Pollution Degree : 2 Shock vibration : MIL-PRF-28800F for A class 2 Instrument Drop Protection : 4 Feet Drop to hardwood on concrete Floor 1-3 Electrical Specifications Accuracy is given as ±(% of reading + counts of least significant digit) at 23°C ± 5°C,with relative humidity Less than 80% R.H. and is specified for one year after calibration. ACV and ACA specifications are ac coupled,true R.M.S. The crest factor may be up to 3.0 as 4000 counts. For non-sinusoidal waveforms, Additional Accuracy by Crest Factor (C.F.): Add 3.0% for C.F. 1.0 ~ 2.0. Add 5.0% for C.F. 2.0 ~ 2.5. Add 7.0% for C.F. 2.5 ~ 3.0. Position Error of Clamp: ±1.5% of LCD reading. 8 A1 EN DC Current Range 60.00A (1) Resolution 0.01A Accuracy ±(1.5%+10D) (2) 300.0A 0.1A ±(1.5%+5D) (1) There are less than 0.3A variation as measuring in different directions. (2) Add 10D to accuracy in Auto AC & DC Sense Mode. AC Current Range Resolution Accuracy (50 ~ 100Hz) Accuracy (100 ~ 400Hz) 60.00A 300.0A 0.01A 0.1A ±(1.5% +25D) ±(2.5%+25D) for < 3A for < 3A ±(1.5% +5D) ±(2.5%+5D) for 3A for 3A Frequency Response: 50 ~ 400Hz (Sine Wave) Low-pass Filter Range 60.00A 300.0A Resolution 0.01A 0.1A Accuracy (50Hz/60Hz) ±(3.5%+25D) for < 3A ±(3.5%+5D) for 3A Cut-off Frequency (-3dB) : Approx. 160Hz Attenuation Characteristic : Approx. -24dB / Oct Inrush Current Range Resolution 300.0A 300.0A Integration Time : 100ms Trigger Current : 5.0 A VoltSense Voltage Range : 80V ~ 600V (At the tip of clamp) 9 A1 EN Limited Warranty This Meter is warranted to the original purchaser against defects in material and workmanship for 3 years from the date of purchase. During this warranty period, manufacturer will, at its option, replace or repair the defective unit, subject to verification of the defect or malfunction. This warranty does not cover fuses, disposable batteries, or damage from abuse, neglect, accident, unauthorized repair, alteration, contamination, or abnormal conditions of operation or handling. Any implied warranties arising out of the sale of this product, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the above. The manufacturer shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expense or economic loss. Some states or countries laws vary, so the above limitations or exclusions may not apply to you. 10 A1 TC - - - - - - - DC AC 11 A1 TC 1 20 12 A1 TC Hold downandpress ACA & DCA CATIII 600V 13 A1 TC ACA&DCA ACA&DCA 1 DCA 50 AC DC 14 A1 TC DCA 2 LPF LPF >5A 5A RMS 100ms LPF 160Hz -24dB 15 A1 TC Voltsense LCD 16 A1 TC 1-1 6000 OL-OL 2 x x 60 x 147 x 31.5 mm 140g LR44 1.5V x 2 20 22mm LVDEN61010-1EN61010-2-032 EMCEN61326-1 CAT.III.600V CAT I II III IV 1-2 2000m (6562ft) 0° C ~ 30° C 80%RH 30° C ~ 40° C 75%RH 40° C ~ 50° C 45%RH -20 60° C0 80% RH 0.2 x ( ) / ° C< 18° C > 28° C 2 MIL-PRF-28800F 2 4 17 A1 TC 1-3 23° C ± 5° C 80% R.H. ±(% + ) ACV ACA 4000 3.0 (C.F.) C.F. 1.0 ~ 2.0 3.0% C.F. 2.0 ~ 2.5 5.0% C.F. 2.5 ~ 3.0 7.0% LCD ±1.5% DC 60.00A (1) 0.01A ±(1.5%+10D) (2) 300.0A 0.1A ±(1.5%+5D) (1) 0.3A (2) AC & DC 10D AC (50 ~ 100Hz) (100 ~ 400Hz) 60.00A 300.0A 0.01A 0.1A ±(1.5% +25D) ±(2.5% +25D) < 3A < 3A ±(1.5% +5D) ±(2.5% +5D) 3A 3A 50 ~ 400Hz (50Hz/60Hz) 60.00A 300.0A 0.01A 0.1A ±(3.5% +25D) < 3A ±(3.5% +5D) 3A (-3dB) 160Hz -24dB 18 A1 TC 300.0A 100ms 5.0A 300.0A 80V ~ 600V 3 19 A1 SC - - - - - - - DC AC 20 A1 SC 1 20 21 A1 SC Hold downandpress ACA & DCA CATIII 600V 22 A1 SC ACA&DCA ACA&DCA 1 DCA 50 AC DC 23 A1 SC DCA 2 LPF LPF >5A 5A RMS 100ms LPF 160Hz -24dB 24 A1 SC Voltsense LCD 25 A1 SC 1-1 6000 OL-OL 2 x x 60 x 147 x 31.5 mm 140g LR44 1.5V x 2 20 22mm LVDEN61010-1EN61010-2-032 EMCEN61326-1 CAT.III.600V CAT I II III IV 1-2 2000m (6562ft) 0° C ~ 30° C 80%RH 30° C ~ 40° C 75%RH 40° C ~ 50° C 45%RH -20 60° C0 80% RH 0.2 x ( ) / ° C< 18° C > 28° C 2 MIL-PRF-28800F 2 4 26 A1 SC 1-3 23° C ± 5° C 80% R.H. ±(% + ) ACV ACA 4000 3.0 (C.F.) C.F. 1.0 ~ 2.0 3.0% C.F. 2.0 ~ 2.5 5.0% C.F. 2.5 ~ 3.0 7.0% LCD ±1.5% DC 60.00A (1) 0.01A ±(1.5%+10D) (2) 300.0A 0.1A ±(1.5%+5D) (1) 0.3A (2) AC & DC 10D AC (50 ~ 100Hz) (100 ~ 400Hz) 60.00A 300.0A 0.01A 0.1A ±(1.5% +25D) ±(2.5% +25D) < 3A < 3A ±(1.5% +5D) ±(2.5% +5D) 3A 3A 50 ~ 400Hz (50Hz/60Hz) 60.00A 300.0A 0.01A 0.1A ±(3.5% +25D) < 3A ±(3.5% +5D) 3A (-3dB) 160Hz -24dB 27 A1 SC 300.0A 100ms 5.0A 300.0A 80V ~ 600V 3 28 A1 JP - - - - - - - 29 A1 JP DC AC EU 30 A1 JP / 1 20 APO Hold downand press 31 A1 ACA & DCA JP III 600V ACA & DCA /ACA & DCA 2 - 32 A1 JP 50 AC DC DCA 2 LPF >5A 5A 100 ms RMS 33 A1 JP LPF LPF 160Hz -24db/ / CLD 34 A1 JP 1-1 6000 OL-OL 2 x x 60 x 147 x 31.5 mm 140 g LR44 1.5V x 2 20 22 mm LVDEN61010-1 EN61010-2-032 EMCEN61326-1 III600V I II III IV 35 A1 JP 1-2 6562ft (2000m) 0°C 30°C80%RH 30°C 40°C75%RH 40°C 50°C45%RH -20 +60°C0 80% RH ( ) 0.2 x ( ) / °C< 18°C> 28°C 2 MIL-PRF-28800F 2 4 ft 1.2m 1-3 80% 23°C ± 5°C ±( % + ) 1 ACV ACA AC 4000 3.0 C.F. : 3.0% C.F.1.0 2.0 5.0% C.F.2.0 2.5 7.0% C.F.2.5 3.0 LCD ±1.5% 36 A1 JP DC 60.00A (1) 0.01 A ±(1.5%+10D) (2) 300.0 A 0.1 A ±(1.5%+5D) (1) 0.3A (2) AC&DC 10D AC (50 ~ 100Hz) (100 ~ 400Hz) 60.00 A 300.0 A 0.01 A 0.1 A < 3A < 3A ±(1.5% +25D) ±(2.5% +25D) 3A 3A ±(1.5% +5D) ±(2.5% +5D) 50~400Hz 60.00 A 300.0 A 0.01 A 0.1 A (50Hz/60Hz) < 3A ±(3.5% +25D) 3A ±(3.5% +5D) (-3dB) 160Hz -24dB / Oct 300.0 A 300.0 A 100ms 5.0 A 80V 600V ( ) 37 A1 JP 3 38 A1 RU ; . , . , . . , , . , , , . . . , , , . . 39 A1 RU , . . , . . . . 40 A1 RU / . 1 20 . Hold downan, dpress 41 A1 ACA DCA RU CAT. III, 600 ACA DCA / ACA DCA >1 - , 42 A1 100A RU 50 . , . , , . (DCA Zero) >1 LPF LPF >5 100 5 . 43 A1 LPF 1A/1k RU LPF 160 -24 . / VoltSense , -, . . 44 A1 RU 1-1 : 6000 . : OL -OL : 2 ( x x ): 60 x 147 x 31,5 : 140 : 2 1,5 LR44 : 20 : 22 : EN61010-1, EN61010-2-032 : EN61326-1 : CAT.III. 600 . CAT I , . II , . III . IV . 45 A1 RU 1-2 . : 2000 (6562 ) : 030 °C, . 80 % 3040 °C, . 75 % 4050 °C, . 45 % : -20 60 °C, 0 80 % RH ( ). : 0,2 x ( ) / °C, < 18 °C, > 28 °C : 2 : MIL-PRF-28800F 2 : 4 1-3 ± (% + ) 23 °C ± 5 °C, . 80 % . ACV ACA: , . 3,0 4000 . (): 3,0 % 1,02,0. 5,0 % 2,02,5. 7,0 % 2,53,0. : ± 1,5 % -. 46 A1 RU 60,00 (1) 300,0 A 0,01 A 0,1 A ± (1,5 % + 10 . ) (2) ± (1,5 % + 5 . ) (1) 0,3 . (2) . . 10 . . (50100 ) (100400 ) 60,00 A 300,0 A 0,01 A 0,1 A ± (1,5 % + 25 . ± (2,5 % + 25 . ) < 3 ) < 3 ± (1,5 % + 5 . ) ± (2,5 % + 5 . 3 ) 3 : 50400 ( ) (50/60 ) 60,00 A 300,0 A 0,01 A 0,1 A ± (3,5 % + 25 . ) < 3 ± (3,5 % + 5 . ) 3 (3 ): 160 : 24 300,0 A 300,0 A : 100 : 5,0 A VoltSense : 80600 ( ) 47 A1 RU 3 . . , , , , , , . , , , , , . , , , , . , . 48 www.appatech.com APAC MGL APPA Corporation cs.apac@mgl-intl.com Flat 4-1, 4/F, No. 35, Section 3 Minquan East Road, Taipei, Taiwan Tel: +886 2-2508-0877 : / : : : : : : : 35 4 : cs.apac@mgl-intl.com : 02-2508-0877 / 72 400-099-1987 cs.cn@mgl-intl.com 700020080