Instruction Manual for nVent RAYCHEM models including: JBM-100-L-A Integrated Power, JBM-100-L-A, Integrated Power, Power
Multiple-Entry Power/Tee Connection with Polymer Junction Box | nVent RAYCHEM
File Info : application/pdf, 12 Pages, 3.30MB
DocumentDocumentJBM-100-L-A Installation Instructions APPROVALS Hazardous Locations (1) (2) Class I, Div. 2, Groups A, B, C, D ® Class II, Div. 2, Groups E, F, G Class III CLI, ZN1, AEx em II T* (1) (JBM-100-L-A only) Ex eb mb IIC T* Gb (2) IECEx (3) JBM-100-L-A is IECEx certified for use with: BTV-CR/BTV-CT: IECEx BAS 20.0011X QTVR-CT: IECEx BAS 20.0013X XTV-CT: IECEx BAS 20.0012X KTV-CT: IECEx BAS 20.0014X HTV-CT: IECEx PTB 21.0007X VPL-CT: IECEx BAS 20.0008X Class I Division 2 (Zone 2**), Groups A, B, C, D Class I Zone 2 IIC Ex eb mb IIC T* Gb; Class I Zone 1 AEx eb mb IIC T* Gb Ex mb tb IIIC T*°C Db; Zone 21 AEx mb tb IIIC T*°C Db * For system Temperature Code, see heating cable or design documentation (1) Except VPL, HTV (FM approval only) (2) Except KTV-CT (3) For HTV-CT only ** Per CE Code Table 18 KIT CONTENTS Item Qty A 1 B 2 C 1 D 1 E 3 F 3 G 1 H 1 I 1 J 1 K 1 Description Stand assembly Grommet plugs Box plug, o-ring, and locknut Cable lubricant Core sealers Green/yellow tubes Box with terminal blocks Lid Spanner Strain relief JBL-100-R Plug-in module Power Connection, Powered Splice, Powered Tee, Dual Power Connection, Splice or Tee with Junction Box and Light DESCRIPTION The nVent RAYCHEM JBM-100-L-A is a Type 4X-rated connection kit. It is designed for use with nVent RAYCHEM BTV-CR, BTV-CT, QTVR-CT, XTV-CT, KTV-CT, HTV-CT and VPL-CT industrial parallel heating cables. The kit can be used to connect one, two, or three heating cables to power, to connect two separate heat-trace circuits, or to splice or tee up to three heating cables. The kit includes a plug-in light module that indicates when power is supplied to the heating cable circuit. Note: For two or more heating cables powered by a single circuit, the length of each heating cable should not exceed the maximum allowable circuit length published in the nVent RAYCHEM self-regulating cables design guide and the total current of all heating cables on the circuit should equal no more than 80% of the circuit breaker current rating. This kit may be installed at temperatures as low as 40°F (40°C). For easier installation store above freezing until just before installation. For technical support call nVent at (800) 545-6258. TOOLS REQUIRED · Wire cutters · Adjustable pliers · Needle nose pliers · Utility knife · 1/4 in or smaller slotted screwdriver · Marking pen · Wire stripper(for VPL-CT) · Large slotted screwdriver · 3/8 in hex key (required for splice and tee connections) ADDITIONAL MATERIALS REQUIRED · Pipe strap · GT-66 or GS-54 glass cloth tape OPTIONAL MATERIALS · Recommended conduit drain: JB-DRAIN-PLUG-3/4IN P/N 278621-000 · Small pipe adapter for 1 in (25 mm) and smaller pipes: Catalog number JBM-SPA P/N D55673-000 A B K C J D I E H F G nVent.com/RAYCHEM | 1 WARNING: This component is an electrical device that must be installed correctly to ensure proper operation and to prevent shock or fire. Read these important warnings and carefully follow all of the installation instructions. · To minimize the danger of fire from sustained electrical arcing if the heating cable is damaged or improperly installed, and to comply with the requirements of nVent, agency certifications, and national electrical codes, ground-fault equipment protection must be used. Arcing may not be stopped by conventional circuit breakers. · The power connection may be powered by more than one circuit. Be sure all power sources are de-energized before opening box. AVERTISSEMENT : Ce composant électrique doit être installé correctement pour éviter les risques d'incendie ou de chocs électriques. Lire ces avertissements importants et suivre attentivement toutes les instructions d'installation. · Pour réduire le danger d'incendie causé par un arc électrique entretenu, si le câble chauffant est endommagé ou mal installé, et pour respecter les exigences de nVent et celles des codes applicables, il est impératif d'utiliser une protection par disjoncteur différentiel. Les disjoncteurs ordinaires ne sont pas toujours capables de supprimer les arcs électriques. · Les approbations et les performances des composants sont basées sur l'utilisation des pièces nVent spécifiées seulement. N'utilisez pas de pièces de rechange ou de ruban isolant en vinyle. · Component approvals and performance are based on the use of nVent-specified parts only. Do not use substitute parts or vinyl electrical tape. · The black heating cable core and fibers are conductive and can short. They must be properly insulated and kept dry. · Damaged bus wires can overheat or short. Do not break bus wire strands when scoring the jacket or core. · Keep components and heating cable ends dry before and during installation. · Use only fire-resistant insulation materials, such as fiberglass wrap or flame-retardant foam. · Le noyau et les fibres du câble chauffant noir sont conducteurs et peuvent provoquer un court-circuit. Ils doivent être correctement isolés et gardés à sec. · Les fils omnibus endommagés peuvent surchauffer ou subir un court-circuit. · Ne brisez jamais les fils omnibus lorsque vous incisez la gaine ou le noyau. · Maintenez les composants et les extrémités des câbles chauffants secs avant et pendant l'installation. · Les fils omnibus peuvent provoquer un court-circuit s'ils se touchent. Les garder à l'écart les uns des autres · N'utilisez que des matériaux isolants ininflammables, par exemple une gaine de fibre de verre ou de la mousse ignifuge. · Laissez ces instructions d'installation à l'utilisateur pour qu'il puisse les consulter. CAUTION: HEALTH HAZARD: Prolonged or repeated contact with the sealant in the core sealer may cause skin irritation. Wash hands thoroughly. Overheating or burning the sealant will produce fumes that may cause polymer fume fever. Avoid contamination of cigarettes or tobacco. Consult MSDS VEN 0058 for further information. CHEMTREC 24-hour emergency telephone: (800) 424-9300 Non-emergency health and safety information: (800) 5456258. MISE EN GARDE : Danger pour la santé : Le contact prolongé ou répété avec le produit d'étanchéité du noyau peut provoquer une irritation de la peau. Lavez-vous les mains soigneusement. La surchauffe et la combustion du produit d'étanchéité produira des vapeurs qui peuvent causer la fièvre des vapeurs de polymères. Évitez la contamination des cigarettes ou du tabac. Consultez la fiche technique santé-sécurité (FTSS) VEN 0058 pour obtenir de plus amples informations. Téléphone en cas d'urgence 24 heures sur 24 de CHEMTREC : (800) 424-9300 Renseignements non urgents en matière de santé et de sécurité : (800) 545-6258 HEATING CABLE TYPES · Determine heating cable type and continue as shown. Outer jacket Braid Inner jacket Heating element Bus wire connection Clear jacket Insulated bus wire VPL Go to Step 1A Outer jacket Braid Inner jacket Conductive fiber Spacer Bus wire XTV-CT, KTV-CT Go to Step 1B Braid Inner jacket Conductive core Bus wire Outer jacket BTV-CR, BTV-CT, QTVR-CT Go to Step 1B 2 | nVent.com/RAYCHEM Outer Jacket Braid Conductive Core + Electrical Insulation Bus Wire HTV-CT Go to Step 1B 1A VPL · Cut each heating cable 12 in (30 cm) from the center of the first indentation, cut at a 45° angle. Cut at 45 angle 12 in (30 cm) minimum Indentation (bus wire connection) · After heating cable has been cut, align indentations. Allow approximately 24 in(60 cm) of heating cable for installation. 1B BTV, QTVR, XTV, KTV, HTV 24 in (60 cm) Centerline of connection · Allow approximately 24 in(60 cm) of heating cable for installation. · Cut off heating cable end at a 45° angle for easier insertion. Go to Step 2 24 in 12 in (60 cm)(30 cm) Centerline of connection Align heating cable indentations Go to Step 2 3 · Lightly score outer jacket around and down as shown. · Bend heating cable to break jacket at score, then peel off jacket. 2 Complete steps 2 through 6 for each heating cable before going on to the next length of heating cable. Box nut · Do not remove box nut from stand. Push heating cable through stand and nut as 18 in (45 cm) shown. Use cable lubricant if needed. · Square off cable end with 90° angle cut. · Do not attach stand to pipe until step 8. Do not cut braid. 7 1/2 in (190 mm) 4 · Determine heating cable type and continue as shown. VPL Go to Step 5A XTV, KTV Go to Step 5B BTV, QTVR Go to Step 5C HTV Go to Step 5D nVent.com/RAYCHEM | 3 5A VPL · Push braid back and bunch as tight as possible. Lightly score inner jacket around and down as shown. · Peel off inner jacket. · Unwind heating element, cut and remove as shown. · Lightly score clear jacket around and down as shown. · Bend heating cable to break jacket at the score then peel off jacket. · Push braid forward. Use a screwdriver to open braid. · Bend heating cable and work it through opening in braid. · Remove insulation from ends of bus wires. · Pull braid tight to make pigtail. 6 in (152 mm) 6 in (152 mm) 5B XTV, KTV · Push braid back to create a pucker. · At pucker use a screwdriver to open braid. · Bend heating cable and work it through opening in braid. · Lightly score inner jacket around and down as shown. · Peel off inner jacket. 6 1/2 in (165 mm) · Cut and remove all fiber strands. · Score and remove center spacer. · Remove any remaining fiber material from bus wires. · Pull braid tight to make pigtail. 1/2 in (13 mm) 4 | nVent.com/RAYCHEM Go to Step 6 Go to Step 6 5C BTV, QTVR · Push braid back to create a pucker. · At pucker use a screwdriver to open braid. · Bend heating cable and work it through opening in braid. · Lightly score inner jacket around and down as shown. · Peel off inner jacket. 6 1/2 in (165 mm) · Notch core. · Peel bus wire from core. 1/4 in (5 mm) · Score core between bus wires at inner jacket. 5D HTV · Push braid back to create a pucker. · At pucker use a screwdriver to open braid. · Bend heating cable and work it through opening in braid. · Score inner jacket and conductive core around and down as shown. · Peel off inner jacket. · Flip the cable 180ºC and score the other side of inner jacket and conductive core. 180° 6 1/2 inches (165 mm) 180° 6 1/2 inches (165 mm) · Remove the inner jacket, conductive core by using needle-nose pliers as shown. · Bend and snap core. · Peel core from bus wire. · Score and remove center insulation. · Remove any remaining core material from bus wires. · Pull braid tight to make pigtail. Go to Step 6 · Remove any remaining material from bus wires. · Pull braid tight to make pigtail. Go to Step 6 nVent.com/RAYCHEM | 5 6 · Mark the jacket as shown. 8 · Fasten stand to pipe. Do not pinch heating cables. · Loop and tape extra heating cable to pipe. 7 5/8 in (15 mm) · Pull heating cable back into stand as shown. Use cable lubricant if needed. 1 1/4 in (32 mm) · Repeat steps 2 through 7 for other heating cables before continuing to step 8. Note: For 1 in (25 mm) and smaller pipes, use adapter (purchased separately) and install between stand and pipe. JBM-SPA adapter for small pipes Pipe strap Glass cloth tape Position adapter this side up. 9 · Remove box nut. O-ring 10 · Install grommet plugs in unused openings. · Place junction box onto stand. Align key ways in large box hole with alignment feature on stand. · Put box nut back onto stand. · Tighten box nut with spanner. Torque = 22 +/- 2 Nm 6 | nVent.com/RAYCHEM 11 12 · Slide strain relief over heating cables, down onto box nut. · Secure strain relief by tightening screws. CAUTION: Health Hazard. Wash hands after contact with sealant. Consult material safety data sheet VEN 0058. Avertissement: risque pour la santé. Se laver les mains après tout contact avec le produit d'étanchéité. Consulter la fiche de données de sécurité VEN 0058. Optional: Knock out drain hole if installed on bottom of pipe. · If needed, re-twist and straighten bus wires, then insert bus wires into guide tubes as shown. Make sure all strands go into the tubes. Tubes 13 · Push core sealer onto the heating cable to the mark made in step 6. Note: Extra force may be required for larger cables or at lower temperatures. Make sure the bus wires do not kink, bunch, or crossover. 15 · Trim bus wires and braid. · Repeat steps 12 through 15 for all heating cables. 1/2 in (13 mm) 1/2 in (13 mm) 14 · Remove the guide tubes and dispose of them in a plastic bag. · Slip the green/yellow tube onto the braid. Heat-shrinking is not required. 16 Finished view of installed core sealers. nVent.com/RAYCHEM | 7 17 This kit uses spring clamp style terminals. Terminals use a steel spring to clamp the wire to provide improved vibration resistance, reduced maintenance and faster installation. To connect wires, firmly insert a slotted screwdriver into the square hole ( 1 ) to open the spring. When fully inserted, the screwdriver will lock into place, allowing you to remove your hand and insert the wire into the round hole ( 2 ). Remove the screwdriver to clamp the wire. The wire is held securely against the bus bar for low contact resistance over time without the need to periodically retighten screws. 1 2 Wire · Refer to wiring diagram, step 18A, 18B, or 18C. · Push screwdriver FIRMLY into square hole. · Insert wire into round hole. · Use green terminal for braid and ground wires. · Remove screwdriver. · Repeat for all connections. Screwdriver slot Wire hole 8 | nVent.com/RAYCHEM 18A Splice Wiring L1 L2 or N 18B Tee Wiring L1 L2 or N 18C Power Connection Wiring WARNING: Shock or fire hazard. When the power connection is energized by two circuits, the L1 and L2 jumpers must be removed to prevent an electrical short. AVERTISSEMENT: risque d'électrocution et d'incendie. Lorsque le raccordement électrique est alimenté par deux circuits, les cavaliers L1 et L2 doivent être enlevés afin d'éviter un court-circuit. L1 Power connection for one heating cable. L2 or N Power supply L1 Power connection for two or three heating cables. L2 or N Power supply Remove jumper L1 Power connection for two heating cable circuits. L2 or N Circuit 1 Circuit 2 Power supply Circuit 1 Circuit 2 Remove jumper nVent.com/RAYCHEM | 9 19A If used as a power connection · Install conduit and fittings as shown. To minimize loosening due to vibration, use flexible conduit. · Pull in power and ground wires, strip off 1/2 in (13 mm) of insulation, and terminate. Power and ground wires 1/2 in (13 mm) 19B If used as a splice or tee connection · Install box plug using 3/8 in hex key. 3/4 in lock nut Watertight conduit seal Make sure conductors are not exposed. Conduit drain · nVent recommends the use of a conduit drain to prevent water condensation build-up. 3/4 in lock nut O-ring Box plug 20 · Plug in the light module in the terminal blocks marked L and N as shown here. (For simplicity the connected wires in the terminal blocks are not shown in this step.) 10 | nVent.com/RAYCHEM 21 · Install lid. Torque = 1.02 to 1.47 Nm · Apply insulation and cladding. · Weather-seal the stand entry. · Leave these instructions with the end user for future reference. Weather seal WARNING: Explosion Hazard- Substitution of Components May Impair Suitablity for Class I Division 2 (Zone 2) AVERTISSEMENT- Risque d'explosion. La substitution de composants peut rendre ce matériel inacceptable pour les emplacements de classe i, division 2 (zone 2). WARNING: Explosion Harzard- Do not disconnect equipment unless power has been switched off or the area is known to be Non-Hazardous. AVERTISSEMENT - Risque d'explosion. Ne pas débrancher l'appareil à moins d'avoir coupé l'alimentation électrique ou à moins qu'il ne s'agisse d'un emplacement non dangereux nVent.com/RAYCHEM | 11 North America Tel +1.800.545.6258 Fax +1.800.527.5703 thermal.info@nVent.com Europe, Middle East, Africa Tel +32.16.213.511 Fax +32.16.213.604 thermal.info@nVent.com Asia Pacific Tel +86.21.2412.1688 Fax +86.21.5426.3167 cn.thermal.info@nVent.com Latin America Tel +1.713.868.4800 Fax +1.713.868.2333 thermal.info@nVent.com nVent.com/RAYCHEM ©2021 nVent. All nVent marks and logos are owned or licensed by nVent Services GmbH or its affiliates. All other trademarks are the property of their respective owners. nVent reserves the right to change specifications without notice. RAYCHEM-IM-H59056-JBM100LA-EN-2111 12 | nVent.com/RAYCHEM PN P000001644