LP42HR21NDBBK40 installation
LIGHTED POWER STRIP installation instructions
January 2019
Customer Service: 800-445-6404 www.TaskLighting.com Design Services & Tech Support: 866-848-9094 DesignAndSupport@TaskLighting.com

Lighted Power Strip DV Series
Installation Instructions for LPS WITH Built-In Power Supply

General Guidelines
· Power source MUST be a 20 amp branch circuit protected by a GFCI at the panel or GFCI prior to the connection at LPS. · All wiring must meet NEC® and local codes. · Light valance recommended. · Firmly insert plug straight into receptacle, applying equal pressure to both blades at the same time. Gently rock plug, if needed.

Bottom of Cabinet Tool

Turn power off at panel. Carefully pry open each piece with tool (provided). Insert Romex connector into knockout hole inside of back frame. Pull wires into LPS.

Wiring for Combined Light and Receptacle Circuit - Non Dimmable
Factory Wired

RED +

BLUE -

SWITCH

DRIVER

BK BK
WT WT BK GRN WT GRN

DIVIDER PLATE

120V

BK
GRN WT

BK
GRN WT

12-1/2" Fixture Shown

Step 1 Secure LPS to wall by screwing into wall studs or use anchors provided. Connect BLACK Romex wire to BLACK wire from receptacles and switch. Connect WHITE Romex wire to WHITE wire from receptacles and driver. Ground all GREEN wires to PEM studs inside of back frame.

Step 2 When connecting 2 or more LPS fixtures, run Romex from fixture to fixture. Ground each section to the next.
Step 3 To terminate last LPS, use wire nuts on ends of wires.
Step 4 Snap cover in place and turn power on.

Wiring for Separate Light and Receptacle Circuits

Factory Wired

RED +

BLUE -

SWITCH
BK BK

DRIVER

WT WT

DIVIDER PLATE 1201V20V
for lights

GRN

BK
GRN WT

BK
GRN WT

120V for 12-1/2" Fixture Shown
receptacles

Step 1 Secure LPS to wall by screwing into wall studs or use anchors provided. If running two circuits, one for receptacles, one for lighting, connect fixture wires to appropriate Romex wires. BLACK to BLACK. WHITE to WHITE. Ground all GREEN wires to PEM studs inside of back frame.

Step 2 When connecting 2 or more LPS fixtures, run Romex from fixture to fixture. Ground each section to the next.
Step 3 To terminate last LPS, use wire nuts on ends of wires.

Step 4 Snap cover in place and turn power on.

Customer Service: 800.445.6404 · Design Services/Technical Support: 866.848.9094 · TaskLighting.com

Lighted Power Strip DV Series
Wiring Diagram for 18-1/2" LPS WITH Built-In Power Supply

Wiring Diagram for Combined Light & Receptacle Circuit - Non Dimmable

Positive (+)

Negative (-)

DRIVER

Back Frame

Divider Plate

Cover

120V Receptacle Circuit. Must be GFCI Protected.

18-1/2" Fixture Shown

Wiring Diagram for Separate Light & Receptacle Circuits

Positive (+)

Negative (-)

DRIVER

Back Frame

Divider Plate

Cover

Lighting Circuit

120V Receptacle Circuit. Must be GFCI Protected. (non dimmable)

18-1/2" Fixture Shown
Customer Service: 800.445.6404 · Design Services/Technical Support: 866.848.9094 · TaskLighting.com

Lighted Power Strip RM Series
Installation Instructions for LPS WITHOUT Built-In Power Supply
General Guidelines · Power source MUST be a 20 amp branch circuit protected by a GFCI at the panel or GFCI prior to the connection at LPS. · All wiring must meet NEC® and local codes. · Light valance recommended. · Firmly insert plug straight into receptacle, applying equal pressure to both blades at the same time. Gently rock plug, if needed.

Bottom of Cabinet
Tool
Turn power off at panel. Carefully pry open each piece with tool (provided). Insert Romex connector into knockout hole inside of back frame. Pull wires into LPS.

RED +

BLACK LOW VOLTAGE DIVIDER PLATE

BK WT
GRN GRN 120V

BK
GRN WT

BK
GRN WT

12-1/2" Fixture Shown

Positive (+)

Negative (-)

Back Frame
15vDC wire
Cover

Divider Plate

120V Circuit

18-1/2" Fixture Shown

Remote Power Supply- 120V Entry

Step 1

Secure LPS to wall by screwing into wall studs or use anchors provided. Connect BLACK to BLACK, WHITE to WHITE. Ground all GREEN wires to PEM studs inside of back frame.

Step 2 When connecting two LPS, run Romex from fixture to fixture. Ground each section to the next.

Remote Power Supply-Low Voltage Entry

Step 4

Using appropriate knockout hole, pull low voltage wire from remote power supply into the low voltage space, connect BLACK wire (negative) to BLACK wire from lights and RED wire (positive) to RED wire.

Step 3 To terminate last LPS, use wire nuts on ends of wires.

Step 5 Snap cover in place and turn power on.

Customer Service: 800.445.6404 · Design Services/Technical Support: 866.848.9094 · TaskLighting.com

