FOS Phantom BAR IP65
This manual contains important information. Please read before operating fixture.

1 Safety Warning
WARNING!!! To reduce the risk of fire, electric shock, or injury to persons, follow these important safety instructions:  non-qualified personnel, not to disassemble the light arbitrarily
and lighting accessories inside.  rated voltage range: AC110V-120V/60Hz or AC200V-240V /
50HZ (to be selected).  Do not install near flammable materials, the fixture should be
kept at least 1 meter distance.  lamps used in ambient temperature: -15  -40 , the highest
temperature of the surface of the lamp: 60 .  Do not keep the fixture in conditions that exceed the IP65
protection range, don't use in permanent outdoor installations.  before using the fixture, must ensure the good grounding.  Ensure the safe installation of the fixtures and perform and
regular inspection.  lamps consecutive working time, is not recommended to exceed
10 hours.  Stop using the fixtures, when abnormalities occur during the
operation session.  Fixtures base, screws, clamps, should be regular inspected and
reinforced in a timely manner to prevent any accident.
 The fixture uses passive heat dissipation, and its surface can
easily accumulate dust, so you must clean it weekly to maintain proper cooling and light output.
1

2 Technical Specifications
 Voltage: 100-240V 50-60Hz  Power consumption: 180W  LEDs: 18 x 10W RGBWA 5in1 LED  LED feature: Each Led pixel individual control  LED Approximate lifespan: 20000 hours  Lens Beam Angle: 20°  With Linear Electronic Frost  Control mode: DMX512, Master-slave, Auto, RDM  DMX Channels: 2CH / 6CH / 9CH / 92CH / 94CH  Display: OLED display with 4buttons  Power: PowerCON in/out  Signal: 3pin XLR in/out  Waterproof rate: IP65  Size: 1006 x 140 x 188 mm  Net weight: 10.25 KG
Installation methods: 1. Stand in ground by floor bracket 2. Mount in truss by omega bracket and clamp 3. Vertical suspension via side M8 hole with Clamp 4. Vertically installed by Base stand (optional) 5. Seamless spliced all around.
2

Product Dimension:

3 Menu Layout
1 Key instruction Button M E  

Meaning Menu/back Enter/confirm
up down

2 All the features selected by pressing the "E" key to confirm 3 Screen Password: E-----E

3

LED Display Menu:

Menu

Item1

DMX Address DMX Address

MODE

DMX mode

Slave Auto
Static

Setting

Display Flip Off Screen

Locking Key DMX State
Dimmer Curve

Item2
001--512 2CH 6CH 9CH 92CH 94CH

Item3

Auto

01-15

speed

01-10

Dimmer

000-255

Colour

01-51

Red

000-255

Green

000-255

Blue

000-255

White

000-255

Yellow

000-255

Fog

000-255

Strobe

00-20

On/Off

Off

20s

40s

60s On/Off (Password: E-----E)

DMX hold

Black out

Linear Curve

Exponential

4

System info

Dimmer Response
White balance Factory reset Firmware
Temperature
RDM UID Time information

Logarithmic

S-curve

LED

Halogen Stage Theatre

Yes/No

YES/NO

Hardware version 18K10W V1.02

Software version 18K10W V3.05

Temp Unit

Celsius Fahrenheit Kelvin

LED pad

xx°C

RDM UID xxxxxxxxxxxx

Usage time Total time

4 DMX Channels Chart

2 Channels

Channel Value

0-4

5-9

1

10-14

...

255-255

2

0-255

Function Null Color 1 Color 2 .... Color 51 Electric frost

5

6Channels

Channel Value

1

0-255

2

0-255

3

0-255

4

0-255

5

0-255

6

0-255

Function Electric frost Red 0%-100% Green 0%-100% Blue 0%-100% White 0%-100% Amber 0-100%

9Channels

CH

Value

1

0-255

2

0-255

3

0-255

4

0-255

5

0-255

6

0-255

7

0-255

8

0-255

9

0-255

Function Dimmer Electric frost Auto Auto speed/Led strobe Red 0%-100% Green 0%-100% Blue 0%-100% White 0%-100% Amber 0%-100%

92Channels

CH

Value

1

0-255

2

0-255

3

0-255

4

0-255

5

0-255

6

0-255

7

0-255

Function Dimmer Electric frost Red1 0%-100% Green1 0%-100% Blue1 0%-100% White1 0%-100% Amber1 0-100%

6

...

...

...

88

0-255 Red18 0%-100%

89

0-255 Green18 0%-100%

90

0-255 Blue18 0%-100%

91

0-255 White18 0%-100%

92

0-255 Amber18 0-100%

94Channels

CH

Value

1

0-255

2

0-255

3

0-255

4

0-255

5

0-255

6

0-255

7

0-255

8

0-255

9

0-255

...

...

90

0-255

91

0-255

92

0-255

93

0-255

94

0-255

Function Dimmer Electric frost Auto Auto speed/Led strobe Red1 0%-100% Green1 0%-100% Blue1 0%-100% White1 0%-100% Amber1 0-100% ... Red18 0%-100% Green18 0%-100% Blue18 0%-100% White18 0%-100% Amber18 0-100%

7

5 Optional base Installation
2lights combine need via a connect part as below, Max. 2lights combine when Vertical no matter use Base stand or via side M8 hole with clamp. Connect parts(optional):
How to install the connect part: First: 3 screws tightened by hand or tool in one light Second: 3screws tightened by hand or tool in another light Third: use tool clockwise rotate 90o to hookup in both lights
8

Base Stand(optional): How to install the Base Stand: First step: 3 screws tightened by hand or tool Second step: use tool clockwise rotate 90o to hookup
9


Name

Warranty Card

Model

Production Purchase

End User Company Name: Add:

Sale Store
Link man: Tel:

Stamp

Description: These must be truthfully fill, seal by the end-user and point-of-sale, or else the warranty will not work (warranty period and terms, see the following) warranty periodone year since purchase warranty terms1If fail when using the product in normal state, you can made under the provisions of the warranty, show the warranty card and purchase bills(copy), and enjoy free maintenance service in a specific service center or the manufacturer. 2. The following will be the implementation of paid service:
(1) Without the effective warranty card (2) There's blank, alter and no point-of-sale name (3) Fail caused by bad earthing, wrong voltage supply (4) Fail caused by transportation or unloading (5) Fail caused by operation not described in the manual (6) Fail caused by disassemble from unauthorized personnel (7) Fail caused by using the unauthorized control system

Note:
Based on our company continue to improve the product, the statement containing data may have changed, without notice. Company retains its right to change specifications related when product is improved. Thank you for your understanding.

10


Adobe PDF Library 24.5.96