Instruction Manual for FOS technologies models including: IP65 FOS Phantom BAR Light, IP65, FOS Phantom BAR Light, Phantom BAR Light, BAR Light, Light
10 hours ago — To reduce the risk of fire, electric shock, or injury to persons, follow these important safety instructions: ▫ non-qualified personnel, not to disassemble the ...
22 hours ago — To reduce the risk of fire, electric shock, or injury to persons, follow these important safety instructions: ▫ non-qualified personnel, not to disassemble the ...
FOS Phantom Bar IP65 | Fos Technologies
FOS Phantom BAR IP65 This manual contains important information. Please read before operating fixture. 1 Safety Warning WARNING!!! To reduce the risk of fire, electric shock, or injury to persons, follow these important safety instructions: non-qualified personnel, not to disassemble the light arbitrarily and lighting accessories inside. rated voltage range: AC110V-120V/60Hz or AC200V-240V / 50HZ (to be selected). Do not install near flammable materials, the fixture should be kept at least 1 meter distance. lamps used in ambient temperature: -15 -40 , the highest temperature of the surface of the lamp: 60 . Do not keep the fixture in conditions that exceed the IP65 protection range, don't use in permanent outdoor installations. before using the fixture, must ensure the good grounding. Ensure the safe installation of the fixtures and perform and regular inspection. lamps consecutive working time, is not recommended to exceed 10 hours. Stop using the fixtures, when abnormalities occur during the operation session. Fixtures base, screws, clamps, should be regular inspected and reinforced in a timely manner to prevent any accident. The fixture uses passive heat dissipation, and its surface can easily accumulate dust, so you must clean it weekly to maintain proper cooling and light output. 1 2 Technical Specifications Voltage: 100-240V 50-60Hz Power consumption: 180W LEDs: 18 x 10W RGBWA 5in1 LED LED feature: Each Led pixel individual control LED Approximate lifespan: 20000 hours Lens Beam Angle: 20° With Linear Electronic Frost Control mode: DMX512, Master-slave, Auto, RDM DMX Channels: 2CH / 6CH / 9CH / 92CH / 94CH Display: OLED display with 4buttons Power: PowerCON in/out Signal: 3pin XLR in/out Waterproof rate: IP65 Size: 1006 x 140 x 188 mm Net weight: 10.25 KG Installation methods: 1. Stand in ground by floor bracket 2. Mount in truss by omega bracket and clamp 3. Vertical suspension via side M8 hole with Clamp 4. Vertically installed by Base stand (optional) 5. Seamless spliced all around. 2 Product Dimension: 3 Menu Layout 1 Key instruction Button M E Meaning Menu/back Enter/confirm up down 2 All the features selected by pressing the "E" key to confirm 3 Screen Password: E-----E 3 LED Display Menu: Menu Item1 DMX Address DMX Address MODE DMX mode Slave Auto Static Setting Display Flip Off Screen Locking Key DMX State Dimmer Curve Item2 001--512 2CH 6CH 9CH 92CH 94CH Item3 Auto 01-15 speed 01-10 Dimmer 000-255 Colour 01-51 Red 000-255 Green 000-255 Blue 000-255 White 000-255 Yellow 000-255 Fog 000-255 Strobe 00-20 On/Off Off 20s 40s 60s On/Off (Password: E-----E) DMX hold Black out Linear Curve Exponential 4 System info Dimmer Response White balance Factory reset Firmware Temperature RDM UID Time information Logarithmic S-curve LED Halogen Stage Theatre Yes/No YES/NO Hardware version 18K10W V1.02 Software version 18K10W V3.05 Temp Unit Celsius Fahrenheit Kelvin LED pad xx°C RDM UID xxxxxxxxxxxx Usage time Total time 4 DMX Channels Chart 2 Channels Channel Value 0-4 5-9 1 10-14 ... 255-255 2 0-255 Function Null Color 1 Color 2 .... Color 51 Electric frost 5 6Channels Channel Value 1 0-255 2 0-255 3 0-255 4 0-255 5 0-255 6 0-255 Function Electric frost Red 0%-100% Green 0%-100% Blue 0%-100% White 0%-100% Amber 0-100% 9Channels CH Value 1 0-255 2 0-255 3 0-255 4 0-255 5 0-255 6 0-255 7 0-255 8 0-255 9 0-255 Function Dimmer Electric frost Auto Auto speed/Led strobe Red 0%-100% Green 0%-100% Blue 0%-100% White 0%-100% Amber 0%-100% 92Channels CH Value 1 0-255 2 0-255 3 0-255 4 0-255 5 0-255 6 0-255 7 0-255 Function Dimmer Electric frost Red1 0%-100% Green1 0%-100% Blue1 0%-100% White1 0%-100% Amber1 0-100% 6 ... ... ... 88 0-255 Red18 0%-100% 89 0-255 Green18 0%-100% 90 0-255 Blue18 0%-100% 91 0-255 White18 0%-100% 92 0-255 Amber18 0-100% 94Channels CH Value 1 0-255 2 0-255 3 0-255 4 0-255 5 0-255 6 0-255 7 0-255 8 0-255 9 0-255 ... ... 90 0-255 91 0-255 92 0-255 93 0-255 94 0-255 Function Dimmer Electric frost Auto Auto speed/Led strobe Red1 0%-100% Green1 0%-100% Blue1 0%-100% White1 0%-100% Amber1 0-100% ... Red18 0%-100% Green18 0%-100% Blue18 0%-100% White18 0%-100% Amber18 0-100% 7 5 Optional base Installation 2lights combine need via a connect part as below, Max. 2lights combine when Vertical no matter use Base stand or via side M8 hole with clamp. Connect parts(optional): How to install the connect part: First: 3 screws tightened by hand or tool in one light Second: 3screws tightened by hand or tool in another light Third: use tool clockwise rotate 90o to hookup in both lights 8 Base Stand(optional): How to install the Base Stand: First step: 3 screws tightened by hand or tool Second step: use tool clockwise rotate 90o to hookup 9 Name Warranty Card Model Production Purchase End User Company Name: Add: Sale Store Link man: Tel: Stamp Description: These must be truthfully fill, seal by the end-user and point-of-sale, or else the warranty will not work (warranty period and terms, see the following) warranty periodone year since purchase warranty terms1If fail when using the product in normal state, you can made under the provisions of the warranty, show the warranty card and purchase bills(copy), and enjoy free maintenance service in a specific service center or the manufacturer. 2. The following will be the implementation of paid service: (1) Without the effective warranty card (2) There's blank, alter and no point-of-sale name (3) Fail caused by bad earthing, wrong voltage supply (4) Fail caused by transportation or unloading (5) Fail caused by operation not described in the manual (6) Fail caused by disassemble from unauthorized personnel (7) Fail caused by using the unauthorized control system Note: Based on our company continue to improve the product, the statement containing data may have changed, without notice. Company retains its right to change specifications related when product is improved. Thank you for your understanding. 10Adobe PDF Library 24.5.96