User Manual for DNAKE models including: EVC-ICC-A5, Intelligent Elevator Control Module, EVC-ICC-A5 Intelligent Elevator Control Module
EVC-ICC-A5 User Manual V1.0.0ENG 1 Intelligent Elevator Control Module User Manual . Dnake (Xiamen) Intelligent Technology Co., Ltd. Tel: 86-592-5705812
Step 2: Use our Search Tool to find IP address of EVC module. The ID number is E×××× for the EVC module. You can query the device ID, Mac address and IP address. Step 3: Change the local IP address of the PC on the same network segment according to the IP address of the device. EVC-ICC-A5 User Manual V1.0.0ENG 10.
File Info : application/pdf, 22 Pages, 3.78MB
DocumentDocumentEVC-ICC-A5 User Manual V1.0.0ENG Intelligent Elevator Control Module User Manual Dnake (Xiamen) Intelligent Technology Co., Ltd. Tel: +86-592-5705812 Email: support@dnake.com Fax: +86-592-5705812 URL: http://www.dnake-global.com Address: North Gate, No.1, Haijing Road, Haicang District, Xiamen, 361026, Fujian, China 1 EVC-ICC-A5 User Manual Index V1.0.0ENG 1.General....................................................................................................................3 2.Standard Specification ............................................................................................3 3.Functions ................................................................................................................4 4.Dimensions .............................................................................................................5 5.Installation.............................................................................................................. 5 6.Wiring Diagram .......................................................................................................6 7. Quick use steps........................................................................................................9 8.Parameter Settings ...............................................................................................11 8.1 Main............................................................................................................11 8.2 Network.......................................................................................................11 8.3 Device.........................................................................................................12 8.4 Settings.......................................................................................................12 8.4.1 EVRC mode......................................................................................13 8.4.2 EVDC mode(Type: only control Down Button of elevator )...............17 8.4.3 EVDC mode(Type: control UP & Down Buttons of elevator ) ...........18 8.5 Card ............................................................................................................20 8.6 Logout.........................................................................................................22 9.System Connection...............................................................................................22 2 EVC-ICC-A5 User Manual V1.0.0ENG 1.General The elevator is one of the main tools for people in vertical moving. The wide use of the elevator system brings people a lot of convenience and benefits. In most cases, when using the elevator, it's short of measures in safety management and intelligence as well as personal access and permission management. With POE power supply, the equipment uses TCP/IP to communicate and establish system network. It supports network expansion and elevator call permission control by elevator cab button. (Two 485 interfaces are available for extending card interface and communication interface. It identifies the users through IC/ID card and the password, then gives the access permissions.It communicates data and configures the network through 485 bus.) 2.Standard Specification Channels 16 Parameter Storage Enclosure Operation Parameters are stored by EEPROM for more than 10 years IP30 Weight 0.5 Kg Dimensions 197mm(L)*89mm(W)*37mm(H) Ambient Temperature -40 +70 Ambient Humidity 20% to 93% Power Supply POE(Optional 24VDC) Communication RS485*2 & TCP/IP Control Method Relay(1A 120VAC;1A 24VDC) Firmware Upgrade USB/Ethernet Remote Management Yes Network Ethernet (10/100Base-T) RJ-45 RS485 Communication 2 channels Standby Consumption 4W Max Consumption (NC ) 7W Mini Consumption (NO) 1W 3 EVC-ICC-A5 User Manual 3.Functions V1.0.0ENG No. Function No. Network Port for Communication and POE Power Supply Reserved12VDC power supply RS485+ & RS485-,Used to connect ID/IC card reader RS485+ & RS485-, Used for communication with DNAKE outdoor panel or computer serial port Function B1~B16,16-channels relay for controlling elevator key panel Reserved24VDC power supply Fire Switch Indicator Red: power supply(always on) Green: communicating(flashing) 4 EVC-ICC-A5 User Manual 4.Dimensions V1.0.0ENG 5.Installation DIN rail installation 5 EVC-ICC-A5 User Manual 6.Wiring Diagram Connect to Outdoor Panel or Computer V1.0.0ENG Connect to Elevator Working mode:EVDC (Control Down Button) 6 EVC-ICC-A5 User Manual Working mode:EVDC (Control UP & Down Buttons) V1.0.0ENG Working mode:EVRC 7 EVC-ICC-A5 User Manual Fire Switch V1.0.0ENG Connect to ID/IC Card Reader 8 EVC-ICC-A5 User Manual 7.Quick use steps V1.0.0ENG Working logic Unlock from the indoor monitor(or click "call elevator" icon). Monitor will sends command to Outdoor panel,then Outdoor panel sends command to EVC IP Relay Module via network(or RS485 command at the same time);then the corresponding relay will be triggered. Step 1: Connect the EVC ip relay module and PC to network switch. Step 2: Use our Search Tool to find IP address of EVC module The ID number is E×××× for the EVC module. You can query the device ID, Mac address and IP address. Step 3: Change the local IP address of the PC on the same network segment according to the IP address of the device. 9 EVC-ICC-A5 User Manual V1.0.0ENG Step 4: Input the IP address of EVC to the browser, then input the user name and password(the default name is "admin",the password is "123456") to into the following interface: 10 EVC-ICC-A5 User Manual 8.Parameter Settings 8.1 Main The system and software information: 8.2 Network V1.0.0ENG Network Settings: DHCP: enable / disable DHCP function IP: IP address should be unique in the same network Mask: according to the actual network situation Gateway: according to the actual network situation DNS: according to the actual network situation Click the submit button to complete parameter modification: 11 EVC-ICC-A5 User Manual 8.3 Device V1.0.0ENG Lift control device settings: Build: Building number of EVC ( the same with the outdoor panel which is used together.),range 1~999 Riser: Unit number of EVC,range 0~99 Device Address: range 0~98 Click the submit button to complete parameter modification: 8.4 Settings 12 EVC-ICC-A5 User Manual V1.0.0ENG Lift control Settings: Mode: Working mode EVRC or EVDC EVRC:Usually used to control the internal call panel of elevator Use contacts:Choose the type of contacts Type:Control down and up key of lift's external call panel,or only control down key of lift's external call panel Relay time:The default time is 500ms,which is used to stimulate the time of pressing up and down key. EVDC:Usually used to control the external panel of elevator Select the EVRC/EVDC mode and click the submit button, the corresponding parameter setting interface will appear. Use contacts:Choose the type of contacts Type:Control Automatically or Control Manually Use:Configure the settings based on Floor and Apartment Lift release time (card):The duration of triggering with card Lift release time (intercom): The duration of triggering via intercom Energise all relays(FailSafe):if you want the relay status to be opposite when power it,enable it,if not,leave it alone. Usage: On EVRC mode of the elevator module, when you enable this option, you can use the NC port of the relays as an NO port to connect the Floor buttons inside the elevator. In this way, the module in the case of failure or power will not affect the normal use of the elevator. 8.4.1 EVRC mode Lift release time (card): 0~9999 (default 5s)seconds Lift release time (intercom):0~9999 (default 1s)seconds use Contacts COM/NO:When receiving the corresponding trigger command, the normally-open (NO) relay will activate. use Contacts COM/NC:When receiving the corresponding trigger command, the normally-closed (NC) relay will activate. Type:Control Automatically or Control Manually Use:Configure the settings based on Floor and Apartment Energise all relays(FailSafe): When EVC enables this function, all relays are in the opposite state. When EVC is Powered on with this function enabled,all relays are in the opposite state. use Contacts COM/NO:When receiving the corresponding trigger command, the normally-closed (NC) relay will activate. 13 EVC-ICC-A5 User Manual V1.0.0ENG use Contacts COM/NC:When receiving the corresponding trigger command, the normally-open (NO) relay will activate. The relay will be restored to its original state after Power OFF. If "Use" at "Settings" is configured as "Floor",you will see "Advanced" as follow: If "Use" at "Settings" is configured as "Apartment",you will see "Advanced" as follow: When "Type" is configured as "Automatic",the table will display as follow. In this configuration,the two relays at lift controller will be triggered at the same time,B1 and B9,B2 and B10,B3 and B11...will be triggered in pairs at the same time. Select button: Setting Upload File Path Import: After setting the file path, click Import to upload the file.Only support ".csv" format file. 14 EVC-ICC-A5 User Manual V1.0.0ENG Export: Export configuration file (.csv) Port: Select port 1~16(B1~B16) Floor/Apartment: Support 1 to 4 digits that is the same as the indoor monitor's room number For Example: Indoor Monitor IP Address: 192.168.98.190 Building Number: 1 Unit: 1 Room: 101 Device: 0 Outdoor Panel: IP Address: 192.168.98.54 Building: 1 Unit: 1 15 EVC-ICC-A5 User Manual V1.0.0ENG EVC Module: IP Address:192.168.98.231 Building:1 Riser(Unit):1 Calling room number 101 from the outdoor panel.When indoor monitor unlocks the door, when "Type" is configured as "Manual",the EVC relay Port1 (B1) normally-open contact will work,and visitors can press the floor button he want to visit,in this example,he will have access to press floor 1;When "Type" is configured as "Automatic", the EVC relay Port1 (B1) and Port9 (B9) normally-open contact will work at the same time,vistors no need to do any operation. Permit button: Permission to open the floor where the indoor monitor is located 16 EVC-ICC-A5 User Manual V1.0.0ENG 8.4.2 EVDC mode(Type: only control Down Button of elevator ) 17 EVC-ICC-A5 User Manual V1.0.0ENG Parameter settings are the same as EVRC. Click indoor monitor Elevator icon(only Down button enable) , the EVC relay Port1 (B1) normally-open contact will work. 8.4.3 EVDC mode(Type: control UP & Down Buttons of elevator ) 18 EVC-ICC-A5 User Manual V1.0.0ENG Parameter settings are the same as EVRC. Click indoor monitor Elevator icon(Down button) , the EVC relay Port1 (B1) normallyopen contact will work. Click indoor monitor Elevator icon(UP button) , the EVC relay Port9 (B9) normally-open contact will work. Note: Port 1(B1) corresponds to port 9(B9) Port 2(B2) corresponds to port 10(B10) Port 3(B3) corresponds to port 11(B11) Port 4(B4) corresponds to port 12(B12) Port 5(B5) corresponds to port 13(B13) Port 6(B6) corresponds to port 14(B14) 19 EVC-ICC-A5 User Manual V1.0.0ENG 8.5 Card 20 EVC-ICC-A5 User Manual V1.0.0ENG The controller supports to connect with a card reader via RS485 to realize that the residents can swipe their fobs at lift car to call the lift/elevator,and the controller will provide access to the floor where the fobs are bound with. You can Export and Import the card list here,and also Add the fobs/cards here manually and automatically. If you want to Add the fobs/cards automatically,pls make sure the controller and card reader is connected correctly,and then press "Start read" to start reading card No.,swipe the fob/card above card reader,a card adding interface will come out automatically,you can only input apartment No.,then press "Add" to add this card to the card list. Note:1. The card list only works at "EVRC" mode. 2.Make sure the RS485 port is existing at the controller,because some old version doesnot support RS485 now,because some components are not patched before. 21 EVC-ICC-A5 User Manual 8.6 Logout 9.System Connection V1.0.0ENG 22