Instruction Manual for PARADOX models including: PS45-EI01, PS45-EI02, PS45 75W Supervised Backup Power Supply, Supervised Backup Power Supply, Backup Power Supply, Power Supply
PS45-EI01 02/2020 PARADOX.COM PS45 75W 100-240 Vac to 15 Vdc Supervised Backup Power Supply EVO / MG / SP Installation Manual Introduction The PS45 is a 75W supervised or standalone backup battery multi-purpose
The PS45's firmware can be upgraded in Infield via BabyWare using a. 307USB Direct Connect Interface. Programming EVO. 1. Enter section [3038]. 2. Select ...
File Info : application/pdf, 2 Pages, 321.96KB
DocumentDocumentPS45 75W 100-240 Vac to 15 Vdc Supervised Backup Power Supply EVO / MG / SP Installation Manual Introduction The PS45 is a 75W supervised or standalone backup battery multi-purpose power supply. Mainly designed to power up, up to 10 video cameras, or any 13.8V rated devices. With up to 29 Ah battery backup capability, the PS45 will provide a reliable robust backup power solution. Compatibility · EVO192, EVOHD all versions · MG5075, MG5050, SP5500, SP6000, SP7000 v7.14 and higher · BabyWare v5.2 and higher · Infield v5.2 and higher Connections Connect the 4-wire cable (BLK GRN YEL) on the panel bus, there is no need to connect the RED. Connect the battery (7Ah and up to a 22Ah additional battery) to the BATT terminals on the board using the provided cable. Connect the brick power or the external power supply's DC output to the PS45's DC in 15 VDC + - terminals. Up to an 22Ah additional battery may be added in an external box thus providing 29Ah battery backup. The second battery cannot be installed as a single battery in end product, only in parallel to the 7Ah battery. Separate battery and external box tamper connectors are located on the PS45 board. As the battery ages, its capacity diminishes like all rechargeable components. The minimum acceptable battery capacity is 90%. Any lower value will result in a battery trouble. Connect wires to the tamper and common terminals, no enrollment is needed, it will auto detect the tamper once the terminal is shorted and it will follow panel configuration. Note: Any combination of outputs can be wired in parallel to combine output power. Combine outputs 1 and 2 for one output of 3A. Combine outputs 1, 2 and 3 one output of 4.5A. We recommend that only one PS45 power supply is connected when using an MGSP panel. Battery 1 Connector DC IN Battery 2 Connector AUX Power Tamper Common Brick OR 7Ah Battery 22Ah Battery 60W Wall Plug Note: Adequate breaking capacity circuit shall be connected in series with the AC input. A plug on the power supply cord is used as the disconnect device. When using the 60W wall plug, the maximum auxiliary current output available is 2.5A. Box Installation Mount the PS45 box using the designated mounting holes, as shown below. We recommend installing the PS45 on a wall. PS45-EI01 02/2020 PARADOX.COM LED Programming MGSP LED AC BATT BUS 1A 2.5A 4A OFF ON No power AC present (Green) No battery or AC fail Battery present No connection to the panel Panel is online If current is below 1A If current is below 2.5A If current is below 4A If current is between 1A and 2.5A (Green) If current is between 2.5A and 4A (Green) If current is above 4A (Orange) Upgrading Firmware The PS45's firmware can be upgraded in Infield via BabyWare using a 307USB Direct Connect Interface. Programming EVO 1. Enter section [3038]. 2. Select option [7] to enable or disable Tamper supervision on the bus module. Default is disabled. 3. Enter section [3034]. Select option [5] and [6] to define Keypad/Bus Module Tamper Recognition options. Refer to the table below. Options 5 OFF OFF 6 OFF ON ON OFF ON ON Description Disabled Trouble only When armed: Follows zone types for zone tamper; generates trouble for module tamper When disarmed: Trouble only When armed: Follows zone types When disarmed: generates audible alarm 4. Enter section [4003]. 5. Enter the PS45's eight-digit module serial number. 6. Enter the three-digit module section number you wish to program. 7. Enter section [002]. The value programmed in this section represents how long the Power Supply Module will wait before reporting an AC power failure to the control panel. The trouble and trouble restore will be generated after the AC fail delay of the module. 8. Enter a three-digit decimal value (000 to 255 minutes). Default is set 30 minutes. 1. Enter section [700]. 2. Select option [7] to enable or disable Tamper supervision on the bus module. Default is disabled. 3. Enter section [705]. Select option [3] and [4] to define Keypad/Bus Module Tamper Recognition options. Refer to the table below. Options 3 OFF OFF 4 OFF ON ON OFF ON ON Description Disabled Trouble only When armed: Audible alarm When disarmed: Trouble only Audible alarm 4. Enter section [839]. The value programmed in this section represents how long the Power Supply Module will wait before reporting an AC power failure. 5. Enter a three-digit decimal value (000 to 255 minutes). Default is set 30 minutes. Technical Specifications AC Power 100 to 240 Vac, 1A, 50-60 Hz Auxiliary Voltage Output 15 Vdc +/- 5% AC or battery backup* Auxiliary Current Output 4.0A maximum continuous current, cut off at 4.5A Type of Power Supply Type A Battery 7 Ah in single box installation 7 Ah (single box) + 22 Ah in dual box installation Low Battery 11.9 Vdc Charging 500 mA to 1500 mA, adaptive Operating Temperature -20 to +50 °C (-4 to 122 °F) Humidity Bus Supervision Dimensions (H x W x D) and Weight Certifications 95% maximum AC, Battery, Aux voltage status and Consumption, Tamper 25.4 x 27.3 x 8.9 cm (10 x 10.75 x 3.5 in.) 1.3 kg (2.86 lbs.) EN 50131-1, EN 50131-6, Grade 2 Class II Certification Body: Applica Test and Certification * When AC power is disconnected and the power supply is operating on battery, the Auxiliary Voltage Output is 15V±10%. Warranty For complete warranty information on this product, please refer to the Limited Warranty Statement is found on our website: paradox.com/terms or contact your local distributor. Specifications may change without prior notice. Patents US, Canadian and international patents may apply. Paradox is a trademark or registered trademark of Paradox Security Systems (Bahamas) Ltd. PS45-EI01 02/2020 PARADOX.COM