Product Overview

This document provides installation instructions for the Danfoss Aero® RA/V thermostatic sensors series.

The Danfoss Aero® RA/V is a thermostatic sensor designed for regulating room temperature.

Installation

The following steps detail the installation process for the Danfoss Aero® RA/V sensor.

  1. Step 1: The Danfoss Aero® RA/V sensor is shown being attached to a valve body. An arrow indicates pushing the sensor onto the valve.

  2. Step 2: A hand is shown turning a locking nut or ring on the sensor. A magnified view highlights the number '5', possibly indicating a setting or a locking position.

  3. Step 3: The sensor is now attached to the valve body. An arrow points to the connection point, confirming the attachment.

  4. Step 4: A close-up shows a locking mechanism or clip being secured to ensure the sensor is firmly attached to the valve.

Temperature Limitation (MAXIMUM)

This section describes how to set the maximum temperature limitation for the Danfoss Aero® RA/V sensor.

  1. Step 1: A close-up of the sensor's temperature dial is shown, with settings from 0 to 5. The dial is set to '4', indicated as MAX = 4. A magnified view confirms the pointer is at '4'.

  2. Step 2: The sensor is shown with an arrow indicating the temperature dial. The dial has MAX and MIN markings. The instruction is to move the pointer to the MAX position.

  3. Step 3: A screwdriver is depicted being used to adjust the internal mechanism that controls the temperature setting.

Temperature Limitation (MINIMUM)

This section describes how to set the minimum temperature limitation for the Danfoss Aero® RA/V sensor.

  1. Step 1: The sensor's temperature dial is shown set to '2', indicated as MIN = 2. A magnified view confirms the pointer is at '2'.

  2. Step 2: The sensor is shown with an arrow indicating the temperature dial. The dial has MAX and MIN markings. The instruction is to move the pointer to the MIN position.

Specific Model Information

Sensor with Code No. 013G1246

This variant includes a "Blind mark" feature. A diagram shows a magnified view of the sensor's dial with the number '3' prominently displayed, indicating a specific setting or marking.

Sensor with Code No. 015G4951

This section details the installation for the sensor with code number 015G4951, showing assembly steps:

  1. Step 1: Components are shown being prepared for assembly.

  2. Step 2: Further assembly of the sensor parts is depicted.

  3. Step 3: A locking mechanism is shown being engaged to secure the assembly.

  4. Step 4: The fully assembled Danfoss Aero® RA/V sensor is shown mounted onto a valve body.

Models: 013G1246, 015G4951, Aero RA-V Series Thermostatic Sensors, Aero RA-V Series, Thermostatic Sensors, Sensors

PDF preview unavailable. Download the PDF instead.

AN446358282428en-000101 Danfoss A/S Adobe PDF library 17.00

Related Documents

Preview Danfoss Aero RA click Thermostatic Sensors Installation Guide
Installation guide for the Danfoss Aero RA click thermostatic sensors series, detailing installation, uninstallation, temperature setting, shut-off, and theft protection features with step-by-step instructions.
Preview Danfoss Aveo RA Click Thermostatic Sensors Installation Guide
Installation guide for the Danfoss Aveo RA Click thermostatic sensors series, covering installation, uninstallation, and temperature limitation.
Preview Danfoss React™ RA click Thermostatic Sensor Installation Guide
Comprehensive installation guide for the Danfoss React™ RA click thermostatic sensors series, covering installation, uninstallation, temperature limitation (maximum and minimum), theft protection, and blind mark features. Includes model numbers 015G3090, 015G3080, 015G3290.
Preview Danfoss Aveo® RA click Thermostatic Sensors Installation Guide
Comprehensive installation, uninstallation, temperature limitation, and theft protection guide for the Danfoss Aveo® RA click thermostatic sensors series. Includes part numbers for associated tools.
Preview Danfoss Aero® and Danfoss Aveo® Tamper Shells Installation Guide
Installation guide for Danfoss Aero® and Danfoss Aveo® tamper shells, designed for RAV and RAVL valve connections. Includes step-by-step instructions and product details.
Preview Danfoss Aero & Aveo Tamper Shells Installation Guide for RAV & RAVL
Step-by-step installation guide for Danfoss Aero and Danfoss Aveo tamper shells with RAV and RAVL connections, including versions with remote sensors.
Preview Danfoss Regus® RA nut with RLV-KB Installation Guide
Comprehensive installation guide for the Danfoss Regus RA nut and RLV-KB valve, providing step-by-step instructions for connecting the thermostatic radiator valve to heating systems.
Preview Danfoss Redia RA click Thermostatic Sensor Installation Guide
Comprehensive installation guide for the Danfoss Redia RA click thermostatic sensor series, covering installation, BIV installation, uninstallation, temperature limitation (maximum and minimum), and theft protection features.