Instructions for Tell models including: LE2000 Electronic Keypad Lock, LE2000, Electronic Keypad Lock, Keypad Lock, Lock

PROGRAMMING INSTRUCTIONS FOR LE2000 ELECTRONIC KEYPAD LOCK

SYSTEM SIGNALS Use Cases Sound Light Correct user code entered to unlock door 2 short beeps 2 short green flashes Lock auto-locks 1 long beep 1 long red flash

TEL-0387-00-LE2000-PI-Chart-QR

Product Templates| Tell Manufacturing

tel-0387-00-le2000-pi-chart-qr ?sfvrsn=9a9b893 6
PROGRAMMING INSTRUCTIONS FOR
LE2000 ELECTRONIC KEYPAD LOCK
Featuring SmartKey TechnologyTM with an SC1 Keyway

REFERENCE GUIDE AT A GLANCE

Exterior Lever

Interior Lever (cover removed)

Tell Button Keypad

Program Button

9V Battery Turnpiece

SC1 Keyway

SmartKey Tool Hole

BEFORE BEGINNING ANY PROGRAMMING: ENSURE THAT THE LOCK IS UNLOCKED AND THE DOOR IS KEPT OPEN.
There are two ways to enter the programming mode. First, by pushing the Program Button (shown above in the diagram). A second method is by creating a Programming Code, which allows you to enter the programming mode if you don't have access to the interior of the lock. Please follow the instructions in the table below to begin programming. *NOTE: Programming Codes cannot be the same as User Code.
If you are using a Programming Code, the Program Button will be disabled except to factory reset the lock.

Move swiftly during programming. If no digit is pressed for 10 seconds, the system will time out and you will need to restart the procedure.

TASK

Step 1

Step 2

Step 3

Step 4

Step 5

Step6

CREATE A PROGRAMMING
CODE

Press Program Button*

ADD USER CODE

ADD ONE-TIME CODE

Listen for 2 beeps

DELETE USER CODE

DELETE ALL Enter Program  Press

USER CODES Code

Button

CHANGE AUTO-

or

or

LOCK DURATION Press Program  Listen for

MUTE/UNMUTE Button* LOCK

2 beeps

ENABLE/ DISABLE USER
CODE

ENABLE/ DISABLE TURNPIECE

Press Program

FACTORY RESET Button

Long beep

(approx 30 sec)

Press 3 then Press Button

Enter 4 to 8 Digit Code and Press Button

Press 1 then

Enter 4 to 8

Press Button Digit Code

Press 7 then

Enter 4 to 8

Press Button Digit Code

Press 2 then Press Button

Enter Code You Wish to Delete and Press Button

Press 4 then Enter 9-9-9-9-9-9 Press Button Press Button

Press 8, Green Flash

Press Button, Enter Delay Time (1-99 seconds)

Press 5, Green Flash

Press Button

Re-Enter 4 to 8 Digit Code and Press Button
Press Button
Press Button
Re-Enter Code You Wish to Delete and Press Button Re-Enter 9-9-9-9-9-9 Press Button
Press Button
Green Flash- Success, Red-Failed Attempt

Green Flash-Success, Red-Failed Attempt
Green Flash-Success, Red-Failed Attempt Green Flash-Success, Red-Failed Attempt
Green Flash-Success, Red-Failed Attempt
Green Flash-Success, Red-Failed Attempt
Green Flash- Success, Red-Failed Attempt
--

Press 6

Press

Button

Green Flash- Success, Red-Failed Attempt

--

Press 9

Press

Button

Green Flash- Success, Red-Failed Attempt

--

Press and

Release Program

--

--

--

Button Again

SYSTEM SIGNALS Use Cases Correct user code entered to unlock door Lock auto-locks Turnpiece rotated to unlock position Turnpiece rotated to locked position Low battery alarm 3 incorrect user codes entered Entering factory reset mode after Program Button is pressed and held for 30 seconds. Entering programming mode after pressing and releasing Program Button Successful programming Unsuccessful programming

Sound 2 short beeps 1 long beep 2 short beeps 1 long beep 10 short beeps 15 long beeps
1 long beep
2 beeps 1 long beep 3 short beeps

Light 2 short green flashes 1 long red flash None None 10 short red flashes 15 long red flashes
None
None 1 long green flash 3 short red flashes

TROUBLESHOOTING PROBLEM

SOLUTION

Keypad is not responding.
Desired user code cannot be programmed. Key cannot be removed when unlocked.
Emergency egress function

Check battery.
For security reasons, the first 4 digits of each user code must be unique. For example, you cannot program a user code 4-8-1-5-1 as well as a user code 4-8-1-5-2. This is a feature to ensure the door is always locked and the key is removed (store room function). To remove the key, return the key to vertical position to remove. This lock has an emergency egress function which allows you to exit by turning the lever on the inside, regardless of whether it is in Auto-lock or Passage mode.

