User Guide for HUAWEI models including: FusionPower UPS5000-A Series Double Conversion UPS, FusionPower, UPS5000-A Series Double Conversion UPS, Double Conversion UPS, Conversion UPS
FusionPower UPS5000-E Series - Powercom-Group
FusionPower Series UPS5000-A-(400-600kVA) Introduction Huawei UPS5000-A (400-600kVA) is an online double conversion UPS which can output pure sine wave with rated voltage of 380/400/415 Vac. UPS5000-A has a high efficiency of up to 96% and high power density of up to 300kVA per cabinet; all-digital control allows precise output at any input and load condition. It's suitable to ensure continuous power supply to critical loads in large datacenters. Scenarios · Large data centers, server rooms, security systems of finance, telecom and other large enterprises · Data center of government or public institutions · Precision instruments Features Reliable · Wide input voltage range to minimize battery use: 485-305 V for 100% load; 305-138 Vac for 100%-40% load (derating linearly) · Better load adaptability: high output power factor up to 1 and no derating for capacitive or inductive devices with a PF>0.5 Efficient · High efficiency of up to 96%, reducing power consumption effectively · High power density of up to 300kVA per rack, 50% footprint saving Simple · Flexible battery configuration: 30-44 batteries per string allow customers to get the faulty battery out instead of replacing it UPS5000-A-200/300K UPS5000-A-400/500K Specifications Rated Capacity 400kVA/400kW 500kVA/500kW 600kVA/600kW Input Wiring 3Ph+N+PE Rated Voltage 380/400/415Vac Mains Input Voltage Range Frequency Range 138-485Vac 40-70Hz Total Harmonic Distortion THDi<3% for 100% linear load Input Power Factor 0.99 Bypass Input Input Wiring Rated Voltage Input Frequency 3Ph+N+PE 380/400/415Vac 50/60±6Hz Battery Rated Voltage 360-528Vdc (The number of batteries can be selected from 30 to 44; 40 batteries in default) Output Wiring 3Ph+N+PE Rated Voltage 380/400/415 Vac±1% Output Frequency Tracking the bypass input (Normal mode); 50/60 Hz±0.05% (Battery mode) Waveform Sine wave (THDv<1%for 100% linear load) Overload Capacity 110% overload for 60 minutes; 125% overload for 10 minutes; 150% overload for 1 minute Output Power Factor 1 System Efficiency 96% Expandability Up to 8 units connected in parallel Operating Temperature 0-40ºC Environment Storage Temperature Relative Humidity Operating Altitude -40 to 70ºC 0%-95% (No condensing) 0-1000m. Above 1000m, derating rate based on EN/IEC 62040-3 Audible Noise Height×Width×De pth (mm) 66-75dB 2000 × 1200 × 850 2000 × 1400× 850 Others Weight Certifications 710kg 850kg 1100kg EN/IEC 62040-1; EN/IEC62040-2; EN/IEC 62040-3; CE;CB;RoHS, REACH,WEEE,etc. Communications Dry contacts, RS485, SNMP Remark: For important systems that are related to important economic interests or public security, such as civil aviation management center, financial clearing center, and trading center, the Tier IV or Tier III power supply level specified in TI942 must be used. That is, two UPSs form dual-bus power supply or the UPS and mains form dualbus power supply. Copyright © Huawei Technologies Co., Ltd. 2020. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd.Adobe InDesign CC (Windows) Adobe PDF Library 20.9.95