
User Manual for Acrel models including: ADL10-E, ADL10-E Din Rail Energy Meter, Din Rail Energy Meter, Rail Energy Meter, Energy Meter, Meter
241 ADL10-E ACREL Co,.Ltd Declare The copyright is the property of Acrel. Any information in any paragraph or section cannot be extracted, copied or otherwise reproduced or propagated. Otherwise offenders shall take all consequences. All rights are reserved. Acrel reserves the right to modify the product specifications herein without notification. Please consult the local agent about the latest specifications before placing a purchase order. 1 General.................................................................................................................................. 1 2 Functions.......................................................................................................................1 3 Technical parameter...................................................................................................... 1 4 Outline...........................................................................................................................2 5 Wiring and installing.................................................................................................3 6 Display description....................................................................................................... 3 7 Communication description..........................................................................................3 1 General ADL10-E LCD IEC62053-21IEC62053-22 ADL10-E single phase electric energy meter is a new generation energy meter designed by Acrel Co,.Ltd with many years' experience in designing electricity meters. Measurement, statistic, communication and LCD display functions are installed in the power meter. This power meter has advantages of high stability, low power consumption and data saving after blackout etc. All meters meet the related technical requirements of electronic power meter in the IEC62053-21 IEC62053-22 standards. 2 Functions Function Function description Measurement of kWh Measurement of electrical parameters LCD LCD Display Communication () Single-phase active kWh (positive and negative) UI PQSPFF Voltage, Current, Active power, Reactive power, Apparent power, Power factor and Frequency 8 LCD 8 bits section LCD display RS485 MODBUS-RTU Communication interface: RS485, Communication protocol: MODBUS-RTU ( means standard; means optional) 3 Technical parameter 3.1 Electric performance Reference voltage Input voltage Reference frequency Power consumption Input current Basic current AC220V 50Hz <10VA 10A Function provide C Measurement performance Communication Maximum current Starting current Consumption Accuracy of measuring Range of measuring Interface Connection mode Protocol 60A 0.004Ib <4VA () (Maximum current) 1 1 Class 000000.00~999999.99kWh RS485(A+B-) Shielded twisted pair conductors MODBUS-RTUDL/T645-07 3.2 Mechanical performance ×× 18mm×96 mm×70mm Outline (Length × Width × Height) 3.3 Work environment Range of temperature Working temperature Storing temperature Relative humidity Altitude -25~55 -40~70 95%(No condensation) <2000m 4 Dimension drawings 4.0N·m 5 Wiring and installing 5.1 Wiring diagram 5.2 Installing notices ADL10 ADL10 single phase electric meter used the direct connecting method. Please pay attention to the direction of input and output while wiring and screw tightly (torque less than 12Nm) prevent the meter from the abnormal work. 6 Display description The meter shows total energy first while turning on and then shows voltage, current and power, etc. in turn. The example shows as following: Current total energy 12.34kWh Current voltage 220.0V Current current10.00A Current power 2.20kW Power factor 1.00 Current even test, baud rate 9600 Current address 001 Current version V1.00 7 Communication description 7.1 Communication protocol MODBUS-RTU DL/T645-2007 The meters adapt Modbus and DL/T645 protocol. Please refer to the relevant standards for more information. 7.2 MODBUS Communication address table Address Variable Length R/W 0000H 4 R 0001H 0002H Current total electricity ... Reserved 000AH 000BH 000CH Voltage Current 2 R 2 R 000DH 2 R 000EH Active power 2 R 000FH Reactive power 2 R Apparent power 0010H 2 R 0011H Power factor 2 R 0012H Frequency ... Reserved 0014H 0015H Address 1 R/W 0015H Communication baud rate 1 R/W 0016H ... 0047H 0048H 0049H ... Reserved Method of testing Device ID 2 R/W 6 R/W Notes unit: 0.01kWh unit0.1V unit0.01A unit 0.001kw unit 0.001kvar unit 0.001kVA unit0.001 unit 0.01Hz 1247 009600 014800 022400 03:1200 02: even 00: none 004BH 004CH 4 004DH Forward reactive electric energy 004EH 004FH Reversing reactive electric energy 4 0050H ... 0067H Reserved 0068H 0069H Forward active electric energy 4 006AH ... 0071H Reserved 0072H 4 0073H Reversing active electric energy R unit 0.01kWh unit R 0.01kWh R 0.01kWh R 0.01kWh