Installation Guide for Radisys models including: PM4165B GPON Home Gateway Unit, PM4165B, GPON Home Gateway Unit, Home Gateway Unit, Gateway Unit, Unit
Radisys Corporation PM4165B Home gateway Unit 2A29YPM4165B 2A29YPM4165B pm4165b
Quick Installation Guide PM4165B Document Revision 0.1 (draft) Copyright 2023 Radisys Corporation, All Rights Reserved 1. Introduction The Radisys PM4165B GPON Home Gateway Unit (HGU) is a Wi-Fi6 dual band GPON ONT complying with the ITU-T G.984. The gateway is best suited for FTTH residential and small office use. 2.1 Contents - PM4165B ONT - Quick Installation Guide - Power Adaptor - RJ45 Ethernet Cable 2.2 Product Specification Interfaces WAN Uplink Ethernet Specification GPON port (SC/APC) 1 10/100/1000/2.5G Base-T port (RJ45) Copyright 2023 Radisys Corporation, All Rights Reserved Wi-Fi VoIP Power Adaptor Input Power Adaptor Output Operating Temperature Operating Humidity Dimensions 2.3 Interfaces 4 10/100/1000 Base-T ports (RJ45) 2x2/2x2 Wi-Fi 6 (internal antennas) 1 FXS ports (RJ11) 90-240VAC, 50/60Hz +12VDC nominal, 3A 0 to 40°C (32 to 104°F) 10 to 90% (non-condensing) 220 x 145 x 51.56 mm Item 1 LEDs 2 ON/OFF Button 3 POWER Description Status LEDs Turn power ON or OFF Power port for external Power Adaptor Copyright 2023 Radisys Corporation, All Rights Reserved 4 WPS 5 LAN 1-4 6 2.5G LAN 7 PHONE 8 RESET Press to initiate WPS connection 1GE Ethernet ports for PC or LAN (RJ45) 2.5GE Ethernet ports for PC or LAN (RJ45) Phone port for telephony (RJ11) Reboot ONT (quick push) Reset to factory (press and hold for 10 seconds) 2.4 LED Status Indicators Label POWER PON LOS INTERNET LAN1-4 2.5G LAN Color Green Green Red Green Green Green Status OFF ON OFF Flashing ON OFF Flashing OFF ON OFF Flashing ON OFF Definition The device is powered OFF. The device is powered ON. The device has not started the registration process. The device is registering or upgrading. The device has completed the ranging process. The received GPON optical power is normal. Loss of Signal (LOS) alarm The device has no internet connection. The device is connected to the internet. Ethernet port is disabled or no service Data transmitting Ethernet port interface is linked Ethernet port is disabled or no service Copyright 2023 Radisys Corporation, All Rights Reserved 2.4GHz 5GHz WPS PHONE Green Green Green Green Flashing ON OFF Flashing OFF OFF Flashing ON OFF Flashing OFF Flashing ON Data transmitting Ethernet port interface is linked 2.4GHz Wi-Fi radio is disabled 2.4GHz Wi-Fi radio is transmitting data traffic 2.4GHz Wi-Fi radio is enabled 5GHz Wi-Fi radio is disabled 5GHz Wi-Fi radio is transmitting data traffic 5GHz Wi-Fi radio is enabled WPS is not active WPS push-button activated Telephone port is disabled or un-registered Telephone line is off hook Telephone port registered for service 2. Installation 1. Remove ONT from packaging. 2. Lay ONT flat on surface or attach ONT to wall. 3. Remove protection plug (black) from WAN port. 4. Connect fiber optic cable with SC/APC termination to WAN port. 5. Connect telephone cable (5) with RJ11 termination to PHONE. 6. Connect Ethernet cable (6) with RJ45 termination to 10G LAN and LAN 1-4. Recommend CAT6 or better Ethernet cable for 2.4GE port. 7. Connect Power Adaptor cable (7) with 2-pin barrel to POWER port. 8. Plug in Power Adaptor into electrical outlet. 9. Push ON/OFF button. Check LED power up sequence. User note: ONT may be upgraded to newer software image prior to provisioning of services. ONT may reset after the initial boot up sequence is complete, or software image is upgraded. Copyright 2023 Radisys Corporation, All Rights Reserved 2.5 Mounting ONT on a wall ONT has two mounting holes that can be used for wall mount placement. Please see diagram for screw separation and location. ONT should be mounted with LEDs facing up and service interfaces facing down to avoid dust and contamination. Copyright 2023 Radisys Corporation, All Rights Reserved 3. Web Graphical User Interface You can access the ONT through a web browser using the following steps: - Connect an Ethernet cable from your computer to any of the LAN 1-4 or 2.5G LAN ports. - Launch a web browser connect to address 192.168.1.1. - After response, enter the following: 1. Username: user 2. Password: user After initial login, it is recommended that password be changed. 4. Caution Please follow the instructions below to avoid physical injury: - This unit is for indoor use only. - All Ethernet, telephone and power wiring are limited to inside of the building. - You should not install ONT during lighting storms to avoid electrical shock. - Never look directly at the fiber port and fiber cable ends when they are powered on. - DO NOT plug in, turn on or attempt to operate an obviously damaged unit. - DO NOT use near water. - DO NOT operate ONT in a location where maximum ambient temp. exceeds 40°C. - DO NOT place near high temperature source. - Set up the unit away from direct sunlight or other electrical equipment. - Open optical connections must use a protective cap under all circumstances to protect against physical damage and dirt. - Avoid impact stresses when handling connectors. - Physical damage to optical connections impairs transmission quality. - Avoid a bend radius in excess of 30 mm for fiber optic links. - Check the available voltage supply. - Only connect approved accessories. Copyright 2023 Radisys Corporation, All Rights Reserved - This equipment is not suitable for use in locations where children are to be present. - DO NOT disassemble the unit. 5. Limited Warranty The product warranty does not cover damage resulting from hardware being installed in areas subject to rain, high humidity, water ingress and dust or debris. Disassembling product or removing enclosure cover from the assembly is a safety hazard and will void warranty. PM4165B may only be repaired by authorized service personnel. Copyright 2023 Radisys Corporation, All Rights Reserved FCC Warning This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. IC Warning This device complies with Industry Canada's licence-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause interference; and (2) This device must accept any interference, including interference that may cause undesired operation of the device. This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Cet appareil est conforme aux CNR exemptes de licence d'Industrie Canada . Son fonctionnement est soumis aux deux conditions suivantes : ( 1 ) Ce dispositif ne peut causer d'interférences ; et ( 2 ) Ce dispositif doit accepter toute interférence , y compris les interférences qui peuvent causer un mauvais fonctionnement de l'appareil. Ce matériel est complété par une exposition de rayonnements ISED pour un environnement naturel. Ce matériel doit être installé et se faire avec une distance minimale de 20cm entre les radiateurs et les autresYour body shop.Microsoft Word 2019