Allsun EM3082 Digital Multimeter User Manual

WARRANTY

This instrument is warranted to be free from defects in material and workmanship for a period of one year. Any instrument found defective within one year from the delivery date and returned to the factory with transportation charges prepaid, will be repaired, adjusted, or replaced at no charge to the original purchaser. This warranty does not cover expandable items such as button cell or fuse. If the defect has been caused by a misuse or abnormal operation conditions, the repair will be billed at a nominal cost.

SAFETY INFORMATION

The multimeter has been designed according to IEC 61010 concerning electronic measuring instruments with a measurement category (CAT II 600V) and Pollution degree 2.

Warning

To avoid possible electric shock or personal injury, follow these guidelines:

Caution

To avoid possible damage to the meter or to the equipment under test, follow these guidelines:

Electrical Symbols

Symbol Description
~ Alternating Current
= Direct Current
Both direct and alternating current
[Warning Symbol] Caution, risk of danger, refer to the operating manual before use.
[Electric Shock Symbol] Caution, risk of electric shock.
[Earth Symbol] Earth (ground) Terminal
[Fuse Symbol] Fuse
CE Conforms to European Union directives
[Double Insulation Symbol] The equipment is protected throughout by double insulation or reinforced insulation.

INTRODUCTION

This meter is a compact 3 1/2-digit autorange digital multimeter for measuring DC and AC voltage, DC and AC current, resistance, diode and Continuity. It features data hold and polarity indication. It is easy to operate and is an ideal measurement tool.

INSTRUCTION

The multimeter features the following components:

Built-in Buzzer:

  1. When you press a key, the buzzer will sound a beep if this press is effective.
  2. The buzzer will sound several short beeps about one minute before the meter turns off automatically and will sound a long beep before the meter turns off automatically.

GENERAL SPECIFICATION

SPECIFICATION

Accuracy is specified for a period of 1 year after calibration and at 18°C – 28°C, with relative humidity up to 75%.

Accuracy specifications take the form of: ± [(% of Reading) + (Number of Least Significant Digits)]

DC Voltage

Range Resolution Accuracy
200mV 0.1mV ± (0.8% + 5)
2V 0.001V
20V 0.01V
200V 0.1V
600V 1V ± (1.0% + 5)

Input Impedance: 10MΩ

Overload Protection: 600V DC/AC rms

AC Voltage

Range Resolution Accuracy
2V 0.001V ± (1.0% + 5)
20V 0.01V
200V 0.1V
600V 1V ± (1.2% + 5)

Input Impedance: 10MΩ

Frequency Range: 40Hz to 400Hz

Overload Protection: 600V DC/AC rms

Response: Average, calibrated in rms of sine wave

DC Current

Range Resolution Accuracy
20mA 0.01mA ± (1.2% + 5)
200mA 0.1mA

Overload Protection: 250mA/250V Fast fuse

AC Current

Range Resolution Accuracy
20mA 0.01mA ± (1.5% + 5)
200mA 0.1mA

Overload Protection: 250mA/250V Fast fuse

Frequency Range: 40Hz to 400Hz

Response: Average, calibrated in rms of sine wave

Resistance

Range Resolution Accuracy
200Ω 0.1Ω ± (1.2% + 5)
2kΩ 0.001kΩ
20kΩ 0.01kΩ ± (1.0% + 5)
200kΩ 0.1kΩ
2MΩ 0.001MΩ ± (1.2% + 5)
20MΩ 0.01MΩ ± (1.5% + 5)

Diode and Continuity

Range Description Remark
[Diode Symbol] The approx. forward voltage drop of the diode will be displayed. Open Circuit Voltage: about 1.5V
[Continuity Symbol] The built-in buzzer will sound if the resistance is less than about 30Ω. The buzzer may or may not sound if the resistance is between 30Ω and 100Ω. The buzzer will not sound if the resistance is more than 100Ω. Open Circuit Voltage: about 0.5V

Open Circuit Voltage: About 0.25V

Overload Protection: 250V DC/AC rms

OPERATING INSTRUCTION

Data Hold Mode

Press the " HOLD " key to hold the present reading on the display. The symbol " HOLD " will appear on the display as an indicator. To exit Data Hold mode, just press this key again. The symbol " HOLD " disappears.

Measuring DC Voltage

  1. Set the function switch to [DC Voltage Symbol] position.
  2. Connect the test leads across the source or circuit to be tested.
  3. Read the reading on the display. The polarity of the red test lead connection will be indicated as well.

Note:

  1. The meter may display an unstable reading before the test leads are connected to the source or circuit to be tested. This is normal and will not affect measurements.
  2. To avoid electric shock to you or damage to the meter, do not measure a voltage higher than 600V.

Measuring AC Voltage

  1. Set the function switch to [AC Voltage Symbol] position.
  2. Connect the test leads across the source or circuit to be tested.
  3. Read the reading on the display.

Note:

  1. The meter may display an unstable reading before the test leads are connected to the source or circuit to be tested. This is normal and will not affect measurements.
  2. To avoid electric shock to you or damage to the meter, do not measure a voltage higher than 600V.

Measuring DC or AC Current

  1. Set the function switch to [Current Symbol] position.
  2. If you want to measure DC current, press the " FUNC " key until the symbol " [DC Current Symbol] " appears on the display. If you want to measure AC current, press the " FUNC " key until the symbol " [AC Current Symbol] " appears on the display.
  3. Turn off power to the circuit to be tested. Then discharge all capacitors.
  4. Break the circuit path to be tested, then connect the test leads in series with the circuit.
  5. Turn on power to the circuit, then read the display. For DC current measurements, the polarity of the red test lead connection will be indicated as well.

Measuring Resistance

  1. Set the function switch to [Resistance Symbol] position.
  2. Connect the test leads across the object to be measured.
  3. Read the reading on the display.

Note:

  1. For resistance measurements > 1MΩ, the meter may take a few seconds to stabilize reading. This is normal for high resistance measurements.
  2. When the test leads are in open circuit state, "OL" will be displayed as overrange indication.
  3. Before measurement, disconnect all power to the circuit to be tested and discharge all capacitors thoroughly.

Measuring Diode

  1. Set the function switch to [Diode Symbol] position. Then press the " FUNC " key until the symbol " [Diode Forward Voltage Symbol] " appears on the display.
  2. Connect the red test lead to the anode of the diode to be tested and the black test lead to the cathode of the diode.
  3. The display shows the approximate forward voltage drop of the diode. If the connection is reversed, "OL" will be shown on the display.

Continuity Test

  1. Set the function switch to [Continuity Symbol] position. Then press the " FUNC " key until the symbol " [Buzzer Symbol] " appears on the display.
  2. Connect the test leads across the circuit to be tested.
  3. If the resistance is less than about 30Ω, the built-in buzzer will sound.

Note: Before test, disconnect all power to the circuit to be tested and discharge all capacitors thoroughly.

Auto Power Off

If you have not operated the meter for more than about 15 minutes, it will turn off automatically and go into "sleep" mode. To arouse the meter from Sleep, rotate the function switch or press a key. If you press the " HOLD " key to arouse the meter from Sleep, the auto power off function will be disabled.

Models: EM3082, Digital Multimeter, EM3082 Digital Multimeter, Multimeter

PDF preview unavailable. Download the PDF instead.

EM3082 manual Adobe Scan for Android 21.09.20-regular(Foxit Advanced PDF Editor) iLovePDF

Related Documents

Preview Digital Earth Tester Users Manual
This manual provides instructions for the Digital Earth Tester, model 480D, covering its features, safety precautions, specifications, and operation for measuring grounding resistance and AC voltage.