Parts and Service Manual

KOMATSU HD 1500-8 DUMP TRUCK

Kit Part Number: 700045

Phone: +61 7 3276 7833 | Website: www.breathe-safe.com.au | Email: sales@breathe-safe.com | Address: 62 Mica Street, Carole Park, 4300, QLD

Controlled Document: M0002 | Issue Date: 07/06/22 | Revision: 2

Key Components: HEPA H14 Variable Speed Pressuriser | INPRESS TS Cabin Display with CO2 Sensor | HEPA Return Air Filter

Introduction

This manual provides comprehensive information for the installation, operation, maintenance, troubleshooting, and servicing of the BreatheSafe cabin pressurisation system fitted to the Komatsu HD 1500-8 Dump Truck. It covers critical parts, technical details, user settings, data download procedures, and warranty information.

Installation Overview

Manufacturer KOMATSU
Type Dump Truck
Model HD 1500-8
Cabin Pressure Max (Not Specified)
Set Auto Cabin Pressure (Not Specified)
Diagram shows the HEPA H14 Variable Speed Pressuriser, the INPRESS TS Cabin Display with Data Recorder, and the HEPA Return Air Filter.

Installation

Refer to the installation guide supplied with the BreatheSafe kit for detailed installation steps.

Safety

WARNING

The pressurisation system described in this manual has areas that may be dangerous if not treated with great care.

DANGER

Use only as directed. Do not handle until all safety precautions, including the Safety Data Sheet, have been read and understood.

The product contains hexachloroethane. Wear protective clothing. If exposed or concerned, get medical advice. Store in a cool, dry, secure location. Keep out of reach of children. Dispose of contents/container per location regulations. When used as directed, exposure should be limited and usually poses no hazard because the hexachloroethane is consumed inside the tube as smoke is produced.

Directions: (Smoke Bomb)

  1. Ensure other workers in close proximity are informed of use. Place on a non-combustible container, away from flammable materials.
  2. Place at Blower intake, or upwind of target area, or near centre of space.
  3. Orient "Smoke Issues Here" toward air stream, away from surfaces. Place candle on a flame / heat resistance plate; if not, it will melt into the plastic surface.
  4. Ensure smoke will not create any hazard where it is anticipated to go.
  5. Ignite emitter inside the cabin using a site-approved device (e.g., solder torch or lighter) and conduct smoke test.
  6. Do not touch or hold the smoke generator after ignition; the item becomes very hot and remains hot after use.

Particulate Behaviour

This is the length of time it takes for a particle to drop from a height of 1.5m in STILL air:

Warehouses and workshops do not have still air, so hazardous airborne particulates may remain in air for longer, increasing the chance for workers to breathe in dust. Ensure PPE is worn when installing this system.

Personal Protective Equipment (PPE)

Pre-operational Safety Checks

Operational Safety Checks

Ending Operations and Cleaning Up

Potential Hazards

Don'ts

*This SWP does not necessarily cover all possible hazards associated with this equipment and should be used in conjunction with other references. It is designed as a guide to be used to compliment training and as a reminder to users prior to equipment use.

Critical Parts & Maintenance Schedule

Maintenance Schedule

The following tables show the suggested maintenance schedule for all units. Site conditions may alter this. Excludes high corrosion environments.

Data download is required to claim the 3-year warranty on the Brushless Blower Motor.

Inspect every 500 Hours and replace when filter is full*

Component / System Action Required
Turbo Pre-cleaner Check operation of the Turbo Pre-cleaner
Pressuriser Blower Ensure blower is operational
HEPA Primary Filter p/n: 500000 Replace HEPA filter element. Vacuum out housing before replacing the filter elements.
HEPA Return Air Filter P/N: 500014 Vacuum inside cabin floor before replacing filter.
Filter Frame Assembly, Mounts, Seals and Filter Housing. Check door seals, all bolts, screws, and all mounts are secure. Check the filter canister & ensure it is correctly fitted. Check latches are operational and in good order. Replace / Re-tension fixtures and fittings required.

15,000 Hours / 36 months*

Component / System Action Required
500 Hour Inspection All 500-hour inspection actions.
Pressuriser's Blower 200002 Replace BRUSHLESS Pressuriser blower

Critical Parts

Item Part Number Qty. Description Service Interval
1 500000 1 Fresh Air HEPA H14 Filter TESTED AS PER EN1822 1000* Hours
2 500014 1 HEPA Return Air Filter 500* Hours
3 200002 1 Brushless Blower motor - INPRESS TL4M 15,000 Hours
4 200027 1 BREATHESAFE DIGITAL DISPLAY – DATA RECORDER (INPRESS TS) (Not Specified)

*Filter service hours are subject to cab sealing efficiency, site conditions and correct system use.

Suggested Schedule Servicing*

HME HEPA FRESH AIR HEPA RECIRCULATION FILTER
GRADER 1000-HOURS 500-HOURS
DOZER 1000-HOURS 500-HOURS
TRUCKS 1000-HOURS 500-HOURS
DRILLS 1000-HOURS 500-HOURS
EXCAVATORS 1000-HOURS 500-HOURS
LOADERS 1000-HOURS 500-HOURS

INPRESS TL TS Overview

The BreatheSafe system fitted is fully automatic. Always keep doors and windows closed even when not in service to prevent airborne dust entering the cabin – always during maintenance. A 10-minute "Pre-Start" program setting will ensure the pressuriser speed remains at 30% motor capacity (user resettable 1-10 min or disabled).

During the walk around / Pre-start:

Before and after entering the cabin:

  1. Please remove debris from shoes and clothes before entering the cabin.
  2. Ensure doors are fully closed, and windows are fully shut.
  3. [Start the engine] & turn HVAC on speed 2 (Medium speed).
  4. The BreatheSafe display shows 50 Pascals or above.

>> There is no further action required <<

Please clean the cabin regularly – Use a HEPA-type vacuum and do not use a brush or compressed air.

Troubleshooting – If the display indicates below 50 pascals (customer specified) or low-pressure alarm is activated, please check the following:

  1. Double-check door(s) are fully closed.
  2. Double-check window(s) are fully closed.
  3. Double-check for any signs of damage: door, windows, seals, or missing panels.

If the display is below 50 pascals (customer specified), please check the following:

  1. Monitor the % (volts) output to BreatheSafe cabin pressure display (i.e., 100% means the fresh air filter is completely dust loaded or a significant cabin pressure leak that the pressuriser cannot overcome).

Please note: Positive pressure above 20 pascals (ISO 23875 minimum) is adequate until the next available service.

Screenshot of the INPRESS TL TS display showing Cabin Pressure, CO2 Concentration, Temperature, Motor Capacity, and options like CO2 Sensor and Temperature Sensor.

Specifications High-Capacity HEPA Pressuriser

List of Abbreviations

Abbr.Full Name
DHDual HEPA
DHPRDual HEPA Powered Recirculation
DHACDual HEPA Activated Carbon
DHACPRDual HEPA Activated Carbon Powered Recirculation
CPMCabin Pressure Monitor
CPUCentral Processing Unit
DBDecibel Sensor
DPMDiesel Particulate Matter
GASGas Sensor
HEPAHigh-Efficiency Particulate Air Filter
HPAFUHigh Pressure Air Filtration Unit
HRAFHEPA Return Air Filter
HVACHeating Ventilation and Air Conditioning
MAFMass Air Flow
OEMOriginal Equipment Manufacturer
PMParticulate Mass
RHRelative Humidity
TEMPTemperature
TSTouch screen
UIUser Interface
VMSVehicle Monitoring System
VSVibration Sensor
OGSPOnGuard Sensor Pod
CO2sCO2 Sensor INPRESS TS

Parts List - TL4 24V DC Pressuriser Unit

Pressuriser Assembly No: 200000

Item No.Qty.DescriptionPart No.
11Pre-cleaner Hood & Rotor Assy200004
24Pre-cleaner Injector Ring200005
31TL Fan Blade (inc. in #7)200006
41TL Nose Cone / Pre-cleaner200007
51TL Motor Housing200008
61TL Filter Housing200009
7124v DC Brushless VSD Motor & TL Fan Blade200002
81O Ring Seal Kit 2 Parts200010
91Included in 8200011
101Wiring Sleeve200012
111HEPA H14 Filter500000
123M6 Nyloc Nut300218 (M6NYL)
133M6 x 55mm Hex Bolt300982 (M655B)
144M8 x 190 Hex Bolt301136 (M8190B)
158M8 x 22mm O/D HD Washer300230 (M8222HTW)
164M8 Nyloc Nut300249 (M8NYL)
175M4 x 75mm Pan Head Phillips Screw300162 (M475PBH)
Exploded view diagram of the TL4 24V DC Pressuriser Unit, showing components numbered 1 through 17.

Parts List GA

Complete Assembly No: 700045

Item No.Part No.RevDescriptionQtyColourCategory
1100011A010Pressuriser Module1Charcoal Grey MX83-682Module
2100011F010Fresh Air Module1Charcoal Grey MX83-682Module
3100011P010Pipework Module1Charcoal Grey MX83-682Module
4100011M010Monitor Mount Assy1Charcoal Grey MX83-682Module
5100011R010Return Air Assy1Charcoal Grey MX83-682Module
Diagram showing the main modules of the system: Pressuriser Module, Fresh Air Module, Pipework Module, Monitor Mount Assy, and Return Air Assy.

Parts List - Pressuriser Mount

Pressuriser Assembly No: 100011A01

Item No.Part No.RevDescriptionQtyMaterialThicknessColourCategory
1ST100007[*]TL Mount Bracket H1Mild Steel3Charcoal Grey MX83-682Stock Item
2200000-TL4 24v DC TL UNIT1Polypropelene--Stock Item
3500000-HEPA H14 F.A.F1---Stock Item
4M825FW-M8 X 25mm Flat Washer8Zinc Plated--Fasteners
5300249 (M8NYL)-M8 Nyloc Nut4Zinc Plated--Fasteners
6301136 (M8190B)-M8 X 190mm Bolt4Zinc Plated--Fasteners
Diagram showing the TL Mount Bracket H and associated fasteners for the pressuriser assembly.

Parts List - Fresh Air Inlet

Fresh Air Module No: 100011F01

Item No.Part No.RevDescriptionQtyColourCategory
1100011F020Fresh Air Assy1Charcoal Grey MX83-682Weld Assy
2100011F030F/A Mount Brkt LH1Charcoal Grey MX83-682Weld Assy
3100011F040F/A Mount Brkt RH1Charcoal Grey MX83-682Weld Assy
Diagram showing the Fresh Air Assy and its mounting brackets.

Parts List - Piping / Ducting

Pipework Assembly No: 100011P01

Item NoPart No.RevDescriptionQtyMaterialThicknessCol.Category
1TQ420276SS350-76.3 x 1.6 @ 350mm1Stainless Steel TubeØ3.0" ODx1.6W/T-Tube
2TQ420276SS450-76.3 x 1.6 @ 450mm1Stainless Steel TubeØ3.0" ODx1.6W/T-Tube
3200307 (TQ4203390LD)-3" X 90* Elbow Long Drop Sil2Silicon--Plumbing
4300850 (TQ420376110)-3" Hose1Silicon--Plumbing
5300848 (TQ420368379)-3" Cobra Neck1---Hardware
6300001 (TQ138048)-65-89mm Hose Clamp7---Hardware
7300480 (TQ5533761)-3" Stauff Clamp2---Hardware
8300483 (TQ5533761MW3)-3" Stauff Weld Plate1Mild Steel--Hardware
9300481 (TQ55337617W3)-3" Stauff Cover Plate1Mild Steel--Hardware
Diagram showing various piping and ducting components including elbows, hoses, clamps, and plates.

Parts List - Monitor Mount

Monitor Assembly No: 100011M01

Item No.Part No.RevDescriptionQtyColourCategory
1100011M020Monitor Mount Assy1Charcoal Grey MX83-682Assy
2200027N/AINPRESS TS Display with Data Recorder1-Stock Item
3200031N/ACO2 Sensor (Suit 200027)1-Stock Item
4300016 (RJ45300)N/ACAT 5E FTP 300mm Cable w/ RJ45 Plug1-Stock Item
5300164 (M4NYL)N/AM4 NYLOC NUTS4-Stock Item
6300155 (M412PBH)N/AM4 x 12mm Phillips Button Head Screw4-Stock Item
7300010 (M530PHCSK)N/AM5 x 30mm HEX Counter Sunk Screw4-Stock Item
8400001 (L100001)N/A12 Pin 0.5m Master Controller Loom1--
9400002 (L100002)N/A2 Pin 5m Main Power & Earth Supply Loom1--
10400003 (L100003)N/A3 Pin 5m Power, Earth & Speed Control Loom1--
11400004 (L100004)N/A5m Air Pressure Sense Pipe w/ Sleeving1--

NOTE: Items 4 -13 not shown in diagram.

The INPRESS Cabin Pressure Monitor can be installed independently to display and record cabin pressure. This is a cost-effective method for fitting a cabin pressure display including capability to record & download data.

Please note that positive AIR pressure inside the cabin does not mean overall safety without SUBMICRON or high-efficiency particulate air (HEPA) filtration pressurisation.

Diagram showing the Monitor Mount Assy with the INPRESS TS Display and CO2 Sensor, along with associated cables and connectors.

Parts List - Return Air Filtration

Return Air Filter No: 100011R01

Item NoPart No.RevDescriptionQtyMaterialThicknessColourCategory
1100011R020R.A.F. Base Assy1Prt DwgsPrt DwgsCharcoal Grey MX83-682Weld Assy
2100011R030Clamp Assy4Prt DwgsPrt DwgsCharcoal Grey MX83-682Weld Assy
3100011-R2030R.A.F. Filter Outer1Zan1.6Charcoal Grey MX83-682R.A.F. Frame
4500014 (TQ4701280250H)-HEPA Filter 280 x 250 x 311-280 x 250 x 31-HEPA Filter
5300813 (TQ9111525)-M6 Female Scallop Knob4---Hardware
Diagram showing the Return Air Filter components, including the base assembly, clamp assembly, outer frame, and HEPA filter.

Technical Details

Display Key Features

CO2 Sensor

Diagram illustrating the INPRESS TS display unit with dimensions and a close-up of the CO2 sensor with dimensions.

Smoke Emitter Cabin Pressure Leak Test

Link to MSDS: SMOKE GENERATOR TQ7621AT30S.pdf

Smoke Emitter Cabin Pressure Leak Test Procedure

  1. The pressuriser system is switched on (TEST MODE).
  2. Hold the smoke emitter angled down.
  3. Ignite emitter using a site-approved ignitor (e.g., solder torch or 'lighter').
  4. When the product ignites, remove the lighter.
  5. If the product flames up, blow out the flame.
  6. Place the emitter in a non-flammable container and place it inside the cabin at floor level and close the door/windows.
  7. Observe smoke leaks to indicate worn-out or broken seal locations. Check leakage points outside the cabin.
  8. Do not come into contact with or inhale smoke haze.
  9. Wait until the smoke haze completely disperses before re-entering the cabin. Open door to allow sufficient ventilation of smoke prior to entering cabin.

Cabin Sealing Test Procedure

Cabin Sealing Efficiency Test Procedure

  1. Start Engine – Pressuriser System is ON.
  2. Ensure all windows & door(s) are CLOSED correctly (no cabin pressure leaks).
  3. NOTE: For a new cabin with effective seals, you may need to open a window slightly before closing the door to bleed the static cabin air pressure outwards. Once the door is fully closed, then close windows to begin testing.
  4. Enter the Settings menu via the touch screen button.
  5. Select and press the System Check button to go to System Test – Max Fan.
  6. Record / photograph the maximum cabin pressure achieved.
Screenshots showing the INPRESS TS display during the cabin sealing test, illustrating steps like 'Press Settings' and 'Press "System Check – Set Max" box', and the final result display.

Commissioning Procedures – Cabin Pressuriser

Follow each step of the installation guide that was supplied with the BreatheSafe kit. Cabin sealing is an integral part of RS20 & ISO 23875; you must ensure that cabin seals are adequate for maintaining positive pressure. In addition, the site (end-user) must have the correct procedure(s) for servicing OPERATOR enclosure seals in a proactive manner rather than reactive. Items such as door and window seals must be in good working order or new seals FITTED before the BreatheSafe system installation.

Touch-screen cabin pressure display/controller Part# 200027:

Submission for commissioning procedure:

The commissioning images required are:

Fill in the BreatheSafe Service Tag with the following details:

Please upload machine and installation details in conjunction with the required images. A Commissioning Certificate will be sent to the email address you nominate. **Extended warranty for (RS20 & ISO 23875) BreatheSafe Systems is only applicable to operator enclosures meeting this requirement.

Proceed to online commissioning: Commissioning - BreatheSafe

Diagram illustrating the commissioning submission process, including required images and service tag details.

Troubleshooting Guide

FAULTPOSSIBLE CAUSESOLUTION
*ERR Error CodePoor Sensor connectionRemove & refit pod connection cable
Corrupted codingAccess Factory setup - Default reset - pin 6759
*Check Filter AlarmService hour timeoutAccess Check Runtime menu - Reset hours via 7597 Code
Temperature / CO2 ErrorSensor not connectedFit sensor or disable via Site access CO2 & Or Temperature menu
Pressuriser running at full speed/NoisyFilter blockedService filter
Door or window openEnsure doors & windows securely shut
Cabin sealing capacity not adequatePerform pressure test procedure & seal leak points as required
Sense pipe blockedEnsure clear & not bent
Internal sensor damagedReplace controller
Filter blocking quicklyDefective cabin sealingPerform pressure test procedure & seal leak points as required
Pre-cleaner failedCheck operation & replace if necessary
Display BlankPoor power supplyCheck mains supply fuse & correct voltage
Check voltage & 20AMP supply/connections at pin 1 @ monitor
Check earth continuity at controller pin 12
Controller showing 0.0 Pressure / Low Pressure AlarmFailed ControllerReplace monitor
Fresh air filter blockedCheck filter condition & replace if required.
Door or window openEnsure doors & windows securely shut
Cabin sealing capacity not adequatePerform pressure test procedure & rectify cab sealing
Pressuriser not operatingPressuriser not operatingEnsure correct voltage 12v or 24v to pressuriser motor pin A
Check 1.6V - 10V present at motor Pin C
Check 20A Supply fuse
Check earth continuity Pin B
Pressure sense tube blockedUnplug at monitor & ensure clear flow to external of cabin
Ensure pressure tube fitted correct port A
Pressuriser not workingPoor Power Supply**No need to change setpoint
Check 20A mains fuse & correct voltage
Ensure adequate wire size & no voltage drop
Ensure correct voltage 12v or 24v to pressuriser motor pin A
Check 1.6V - 10V present at motor Pin C
Poor EarthCheck earth continuity @ motor pin B
Motor faultyReplace TL4M

Access Codes: Site Access: 7597 | Factory Setup: 6759

User Settings Instructions

Enter Set Up Mode

Start-Up Screen > Main Screen > Settings Button > Settings Screen > Site Access Button > Insert Pin > Site Menu

To enter the Setup mode, press the SETTING button. Then enter SITE ACCESS MENU. Type in 4-number pin and press ENTER.

Screenshot showing the PIN entry screen with a keypad and the input "7597".

Set Up Parameters

Placing the BreatheSafe 200027 unit into Setup mode allows the adjustment of the following parameters:

Pressure Setpoint

The pressure setpoint changes the pressure that the cabin will be maintained. INPRESS TS maintains the pre-set pressure within the cabin compared to outside. Enter Setup mode and select ADJUST SETPOINT button. Then, use the onscreen UP and DOWN buttons to change the corresponding fields.

Pressure Alarm Setting

The mining industry benchmark for cabin pressure is 50 pascals and low-pressure is set at 20 pascals. After a delay, the alarm will activate if cabin pressure remains below the pre-set value. Enter Setup mode and select ADJUST SETPOINT button. Then, use the onscreen UP and DOWN buttons to change the corresponding fields.

Screenshots illustrating the navigation through the user settings menus for Pressure Setpoint and Pressure Alarm Setting, including PIN entry and parameter adjustment screens.

Service Interval

Use the onscreen UP and DOWN buttons to change the service interval setpoint. To reset the current runtime to zero, press the RESET CURRENT RUNTIME button and enter the site access pin.

Date & Time Settings

Change the recorded date displayed and measured by the INPRESS TS.

Screenshots illustrating the navigation through the user settings menus for Service Interval and Date & Time Settings.

Alarm Buzzer Settings

To disable the buzzer, toggle through to the ENABLED and DISABLED buttons.

Calibrate Zero Sensor

Over long runtime, the 200027 may need recalibration. This screen allows the sensor to be recalibrated if more than 5 Pascals are out. To recalibrate, open windows and doors, turn off air conditioning, and any other device that may alter cabin pressure. Then, press the AUTO ZERO SENSOR button and leave the cabin while measuring. This process will reset the Zero Pressure.

Screenshots illustrating the navigation through the user settings menus for Alarm Buzzer Settings and Calibrate Zero Sensor.

CO2 Settings

CO2 Module Enable/Disable

Enable or disable the CO2 module used for measuring CO2 levels within the cabin.

CO2 Primary Alarm Point

The first alarm will sound when CO2 levels inside the enclosure reach this point.

CO2 Alarm Delay

After CO2 (concentration in ppm) within the cabin reaches the 1000 ppm setpoint, the alarm will sound after this designated amount of time. The Alarm Delay adjusts the time between the INPRESS TS measuring CO2 concentration and sounding the alarm. Use the onscreen ADJUST buttons to change the corresponding fields. For example, press to toggle through Disabled / 1 - 10 minutes.

CO2 Critical Alarm Mute Reset

The critical alarm is set at 2500 PPM and cannot be changed. The mute delay, however, can be configured.

Screenshots illustrating the navigation through the user settings menus for CO2 Settings, including Alarm Delay and Critical Alarm Mute Reset.

Data Download

Setting up RS232 Connection

  1. Plug the RS232/USB adaptor into a free USB port on your computer.
  2. Open up TeraTerm software. (TeraTerm is an open-source software tool and easily accessible via online search).
  3. Use the following settings in TeraTerm: Serial and choose the correct port connection. Hint: Click on the COMxx Port with the "USB serial Port" connection from the drop-down menu. Example: COM 21. This connection may be different on your computer.
  4. Click OK once the correct communication port has been identified.
  5. Go to SETUP and click on Serial Port.
  6. Change the COM ports to the following configuration: Baud Rate: 57600 Data: 8 bit Parity: EVEN Stop: 2 bit Flow Control: NONE
  7. If required, you may choose to save the COM port settings. Go to Settings and click Save Setup. Name the file and save it.
  8. The next time a download is required, you may restore the setup, and the required COM PORT settings will be loaded, ready to download the data file from the 200027 unit.
  9. From the drop-down menu, click on the Save setup.
  10. Click Restore setup.
  11. Choose the file name you have already saved.

Excel Data Instructions - Unformatted

Open an Excel sheet and select the first cell A-1. Next, press and hold down the CTRL button on your keyboard and then press the letter V on the keyboard.

This procedure will paste the copied data onto that Excel sheet. Once that data has been pasted onto the Excel sheet, click on ‘DATA’ on the pull-down menu, followed by ‘Text to Columns’. Next, select ‘Delimited’ on the newly opened window and click on Next.

Only select the 'Comma' button in the next window and then click 'Finish'. Then, the Excel fields will update such that each piece of data is placed in the correct columns.

The data is now ready for archiving.

  1. Open a blank excel document and click on the page. Then, right-click to paste the copied table.
  2. Fields are: Date, time, motor (volts) output, cabin pressure (Pa), cabin pressure pre-set (Pa), low cabin pressure alarm (Pa).

Data Logging Formats

Alarm Type

CodeDescription
0No alarm
1Low-pressure alarm
2Window open
3Door open
Screenshots illustrating the RS232 connection setup in TeraTerm, saving and restoring configurations, and pasting data into Excel.

Inpress TL Warranty

Express Warranty

All BreatheSafe products carry a warranty against defects in materials or workmanship, provided the defects are not from factors outside of BreatheSafe's control (including neglect, lack of maintenance, improper installation or operation, unauthorized servicing repair, etc.). BreatheSafe will replace goods defected in material or workmanship at our Queensland factory or designated branch*. All parts deemed as failed or faulty must be returned to BreatheSafe for evaluation unless otherwise stated in writing.

Note: Systems must be installed and commissioned as per BreatheSafe installation and commissioning instructions. Once commissioned, the online commissioning sheet must be filled in, extending the components warranty as below. In addition, the system must be serviced and maintained correctly and by trained and qualified personnel. This requisite includes BreatheSafe technicians, qualified automotive air-conditioning technicians, or qualified auto electricians.

Warranty Period - Standard

Must be supplied with a variable speed pressure controller, data download required for 3-year warranty option. Link to online Commissioning and Extended Warranty Registration form: https://www.breathe-safe.com.au/commission/

What is not covered under Express Warranty?

This Express Warranty is VOID if the product is altered, modified, or used in the manner it was not designed for, also including unauthorized repairs, or using maintenance and repair parts other than those supplied by BreatheSafe.

BreatheSafe Responsibilities

If there is a defect in material or workmanship not caused by the excluded failures during the warranty period, BreatheSafe will either replace the defective goods at our Queensland factory, or designated branch*. Alternatively, BreatheSafe may elect to provide new replacement parts, BreatheSafe approved repair parts or assembled components needed to repair the defect. BreatheSafe reserves the right to provide a refund of the purchase price in lieu of replacement or repair at BreatheSafe's discretion. The replacement or repaired product will be sent to you freight prepaid by the customer or made available for pick-up on site.

Users Responsibilities

The customer should ensure that the system is maintained according to BreatheSafe service requirements and only authorized parts must be used to service and maintain BreatheSafe systems. In the event of a suspected warranty claim, BreatheSafe should be contacted in the first instance to arrange the repair or to assist with diagnosis. Claims should be made within one week of the repair.

*After contacting BreatheSafe, you may be required to deliver or send the parts to BreatheSafe's Queensland factory or designated branch. Link to online Warranty claim form: https://www.breathe-safe.com.au/warranty/

Exclusion and Limitations on Damages and Remedies

This warranty is provided in lieu of all other warranties, written or oral, whether expressed by affirmation, promise, description, drawing, model, or sample. To the extent allowed by law, all warranties other than this warranty, whether express or implied, including implied warranties of fitness for a particular purpose, are disclaimed. The maximum liability of BreatheSafe under this warranty shall not exceed the original purchase price of the product. Interference with the equipment by or abuse, or by operating the equipment at ambient temperatures or with electrical power characteristics outside the ranges indicated in our specification shall be excluded from this warranty, as shall consequential damages.

Excluded from any express warranty are costs incurred in relation to service outside our factory or our designated service branch, including traveling time, waiting time, transport costs, mechanical and overtime payments required.

As per Australian Consumer Law: You are entitled to choose a refund or replacement for major failures with goods. If a failure with the goods or service does not amount to a major failure, you are entitled to have the failure rectified in a reasonable time. If this is not done, you are entitled to a refund for the goods and to cancel the contract for the service and obtain a refund of any unused portion. You are also entitled to be compensated for any other reasonably foreseeable loss or damage from a failure in the goods or service.

*This express warranty gives you specific legal rights, and you may also have other rights that vary from country to country.

**Extended warranty for (RS20 & ISO 23875) BreatheSafe Variable Speed Systems is only applicable to operator enclosures meeting this requirement.

Models: HD 1500-8, HD 1500-8 Dump Truck, Dump Truck, Truck

File Info : application/pdf, 29 Pages, 2.78MB

PDF preview unavailable. Download the PDF instead.

KOM-HD-1500-8-HD605-8-DH-INCO2-700045

References

Microsoft Word for Microsoft 365

Related Documents

Preview John Deere 332G Skid Steer Parts and Service Manual | BreatheSafe
Comprehensive parts and service manual for the John Deere 332G Skid Steer featuring BreatheSafe HEPA H14 Pressuriser system, INPRESS TS Cabin Display with CO2 Sensor, and HEPA Return Air Filter. Includes installation, safety, maintenance, specifications, parts lists, troubleshooting, and warranty information.
Preview Caterpillar 432 Loader BreatheSafe Parts and Service Manual
Comprehensive guide for the BreatheSafe cabin pressurisation system on Caterpillar 432 Loader, covering installation, operation, safety, maintenance, parts, and troubleshooting.
Preview Caterpillar 775G Truck Parts and Service Manual - BreatheSafe Air Filtration System
This manual provides comprehensive parts and service information for the BreatheSafe air filtration system installed on Caterpillar 775G Trucks. It covers installation, safety precautions, maintenance schedules, operator guidance, technical specifications, troubleshooting, user settings, data download procedures, and warranty information.
Preview BreatheSafe Parts and Service Manual for KOBELCO SK210 LC Excavator
Comprehensive parts and service manual for the BreatheSafe cabin pressurisation system installed on KOBELCO SK210 LC Excavators. Covers installation, safety, maintenance, operator guide, technical specifications, parts lists, troubleshooting, user settings, data download, and warranty information.
Preview Hitachi ZX225USLC-5 Excavator BreatheSafe Pressuriser Parts and Service Manual
Comprehensive parts and service manual for the BreatheSafe HEPA H14 Variable Speed Pressuriser system installed on the Hitachi ZX225USLC-5 Excavator, covering installation, operation, maintenance, troubleshooting, and warranty.
Preview BreatheSafe Parts and Service Manual for CASE CX60C Excavator
Comprehensive parts and service manual for the BreatheSafe cabin pressurisation system, designed for the CASE CX60C Excavator. Covers installation, operation, maintenance, troubleshooting, and technical specifications for components like the HEPA H14 Pressuriser and INPRESS TS Cabin Display.
Preview BreatheSafe Parts and Service Manual for TATRA T815-2 Offroad Truck
Comprehensive guide detailing the installation, operation, maintenance, and troubleshooting of the BreatheSafe air filtration and pressurization system for the TATRA T815-2 Offroad Truck, featuring HEPA filters and CO2 monitoring.
Preview BreatheSafe HEPA Filtration System for Komatsu PC3400-11: Parts and Service Manual
This Parts and Service Manual details the BreatheSafe HEPA H14 Variable Speed Pressuriser system for Komatsu PC3400-11 cabins, covering installation, maintenance, troubleshooting, and user settings for enhanced operator safety and air quality.