Installation Guide for MOXA models including: EDS-4009 Series, EtherDevice Switch, EDS-4009 Series EtherDevice Switch, Switch
MOXA EDS-4009-3MST-HV-T
File Info : application/pdf, 18 Pages, 1.12MB
DocumentDocumentEDS- 4 0 0 9 Series Quick I nstallation Guide M oxa Et her DeviceTM Sw it ch Version 1 .0 , March 2 0 2 2 Te chnica l Suppor t Con t a ct I nfor m a t ion w w w .m oxa.com / support 2022 Moxa I nc. All right s reserved. P/ N: 1802040090010 *1802040090010* Pa ck a ge Che ck list The EDS- 4009 Series indust rial DI N- rail Et herDevice Sw it ch ( EDS) is shipped wit h t he following it em s. I f any of t hese it em s are m issing or dam aged, please cont act your cust om er service represent at ive for assist ance. · 1 EDS- 4009 Et hernet sw it ch · Quick inst allat ion guide ( print ed) · Warrant y card · Subst ance disclosure t able · Product cert ificat e of qualit y inspect ion ( Sim plified Chinese) · Product not ices ( Sim plified Chinese) N OTE You can find inform at ion and soft w are dow nloads on t he relevant product pages locat ed on Moxa's websit e: www.m oxa.com Default Settings · I P address: 192.168.127.253 · Subnet Mask: 255.255.255.0 · Usernam e: adm in · Passw ord: m oxa Panel View s of EDS- 4 0 0 9 Series 1. 100BaseT( X) LED indicat or 2. 10BaseT( X) LED indicat or 3. 10/ 100BaseT(X) port s, port 4 to 9 4. 100BaseFX port ( SC/ ST type), port 1 to 3 5. 100BaseFX LED indicat or 6. Grounding connect or screw 7. Term inal blocks for power input, digital input, and relay output 8. LED indicat ors: STATE ( S) , FAULT ( F) , PWR1 ( P1) , PWR2 ( P2) , MSTR/ HEAD ( M/ H) , CPLR/ TAI L ( C/ T) , SYNC 9. Console port ( RJ45, RS- 232) 10. USB st orage port ( t ype A, current ly disabled) 11. Model nam e - 2 - Bottom Panel View 1. m icroSD card slot (current ly disabled) 2. Reset but t on 3. DI P swit ches for Turbo Ring, Ring Mast er, and Ring Coupler Mounting Dim ensions ED S- 4 0 0 9 - 3 M SC( - T) / ED S- 4 0 0 9 - 3 SSC( - T) M ode ls - 3 - EDS- 4 0 0 9 - 3 M ST( - T) Models DI N-rail Mounting The DI N- rail m ount ing k it is fixed t o t he back panel of t he EDS device w hen you t ake it out of t he box. Mount t he EDS device on corrosionfree m ount ing rails t hat m eet t he EN 60715 st andard. I nstallation STEP 1 --I nsert t he upper lip of the DI N rail into the DI N-rail mounting kit. STEP 2 --Press t he EDS device t owards t he DI N rail unt il it snaps int o place. - 4 - Rem oval STEP 1 --Pull dow n t he lat ch on the mounting kit with a scr ew d r iv er . STEP 2 & 3 --Slight ly pull t he EDS device forw ard and lift up t o remove it from the DI N rail. N OTE Our DI N rail kit now ut ilizes a quick release m echanism t o m ake it easier for user s t o rem ove t he DI N rail from t he EDS device. W all Mounting ( Optional) For som e applicat ions, y ou w ill find it convenient t o m ount t he Moxa EDS device on a w all, as show n in t he follow ing illust rat ions: STEP 1 --Rem ove t he DI N- rail at t achm ent plat e from t he rear panel of t he EDS device, as illust rat ed in t he diagram on t he right. STEP 2 --Mount ing t he EDS device on a w all requires six screw s. Use t he EDS device, w it h w all m ount plat es at t ached, as a guide t o m ark t he correct locat ions of t he six screws. The heads of t he screws should be less t han 6.0 m m in diam et er, and t he shaft s should be less t han 3.5 m m in diam et er, as shown in t he figure on at right . NOTE Before t ight ening t he screws int o t he wall, m ake sure t he screw head and shank size are suit able by insert ing t he screw t hrough one of t he keyhole- shaped apert ur es of t he Wall Mount ing Plat es. - 5 - N OTE Do not screw t he screw s in all t he w ay--leave about 2 m m t o allow room for sliding t he wall m ount panel bet ween t he wall and t he screws. STEP 3 --Once t he screw s are fixed t o t he wall, insert t he four screw heads t hrough t he wide parts of the keyholeshaped apert ures, and t hen slide t he EDS device downwards, as indicat ed in the figure at the right. Tight en t he four screws for m ore st abilit y. W iring Requirements ATTEN TI ON Safety First ! Ext ernal m et al part s are hot . Take t he necessar y precaut ions if you are required t o handle t he device. ATTEN TI ON I n order t o ensure reliable operat ions, please m ake sure t he operat ing t em perat ure of t he environm ent does not exceed t he specificat ions. When m ount ing an EDS device w it h ot her operat ing unit s in a cabinet wit hout forced vent ilat ion, a m inim um of 4 cm space on bot h t he left and right of t he swit ch is recom m ended. ATTEN TI ON Safety First ! Be sure t o disconnect t he power cord before inst alling and/ or w iring your EDS device. Calculat e t he m axim um possible current in each power wire and com m on wire. Observe all elect rical codes dict at ing t he m axim um current allowable for each wire size. I f t he current goes above t he m axim um rat ings, t he wiring could overheat , causing serious dam age t o your equipm ent . - 6 - Be sure t o read and follow t hese im port ant point s below: · Use separat e pat hs t o rout e w iring for pow er and devices. I f pow er wiring and device wiring pat hs m ust cross, m ake sure t he wires are perpendicular at t he int ersect ion point . N OTE Do not run signal or com m unicat ions wiring and power wiring t hrough t he sam e wire conduit . To avoid int erference, wires wit h different signal charact erist ics should be rout ed separat ely. · You can use t he t ype of signal t ransm it t ed t hrough a w ire t o det erm ine which wires should be kept separat e. The rule of t hum b is t hat wiring t hat shares sim ilar elect rical charact erist ics can be bundled together. · You should separat e input w iring from out put w iring. · We advise t hat you label t he wiring t o all devices in your syst em . Grounding t he M oxa ED S Series Grounding and w ire r out ing help lim it t he effect s of noise due t o elect rom agnet ic int erference ( EMI ) . Run t he ground connect ion from t he ground screw t o t he grounding surface prior t o connect ing devices. ATTEN TI ON This product is int ended t o be m ount ed t o a well- gr ounded m ount ing surface such as a m et al panel. Sugge st e d W ir e Type for W ir ing Re la y Cont a ct ( RELAY) , Digit al I nput ( DI ) , and Pow er I nput s ( P1/ P2) The EDS device includes t w o 4- pins 3.5 m m pin- pit ch t erm inal block s. When w iring t he relay cont act ( RELAY) , digit al input ( DI ) , and pow er input s ( P1/ P2) , w e suggest using t he cable t ype AWG 18- 24 and t he corresponding pin t ype cable t erm inals. N OTE The wire m ust be able t o wit hst and at least 105° C and t he t orque value should be 4.5 lb-in ( 0.51 N- m ) . - 7 - N OTE We suggest t he lengt h of t he pin t ype cable t erm inal is 8 m m . I n order t o t ight en t he wire properly, use a sm all flat head screwdriver t o press t he push-in but t on beside each t erm inal of t he t erm inal block connect or before and during insert ing t he w ire. Release t he screw driver aft er t he w ire has been fully insert ed. Please refer t o t he diagram below . W ir ing t he Re la y Cont a ct The EDS device has one set of relay out put . This relay cont act uses t w o cont act s of t he t erm inal block on t he EDS's pow er m odule. Refer t o t he sect ion for det ailed inst ruct ions on how t o connect t he wires t o t he t erm inal block connect or, and how t o at t ach t he t erm inal block connect or t o t he t erm inal block recept or. Relay: The t wo cont act s of t he 4- pin t erm inal block connect or are used t o det ect user- configured event s. The t wo w ires at t ached t o t he fault cont act s form an open circuit when a user-configured event is triggered or there is no power supply t o t he swit ch. I f a userconfigured event does not occur, t he fault circuit rem ains closed. - 8 - W iring the Redundant Pow er I nputs The EDS device includes bot h high- volt age and low - volt age pr oduct s. For t he low - volt age ( LV m odels) product s, t here are t w o pow er input s for redundancy; for t he high-volt age (HV m odels) product s, t here is only one power input . Bot h use t erm inal block connect ors on t he right side panel of t he product . Refer t o t he inst ruct ions and diagram below on how t o connect t he wires t o t he t erm inal block connect or on t he recept or. STEP 1 : I nsert t he Posit ive/ Negat ive DC or Line/ Neut ral AC w ires int o t he V+ / V- or L/ N t erm inals, respect ively. STEP 2 : To keep t he DC or AC wires from pulling loose, use a sm all flat blade screwdriver t o t ight en t he wireclam p screws on t he front of t he t erm inal block connect or. STEP 3 : I nsert t he plast ic t erm inal block connect or prongs int o t he t erm inal block recept or, which is locat ed on t he EDS devices' right side. W iring the Digital I nputs The EDS device has one set of digit al input ( DI ) . The DI consist s of t w o cont act s of t he 4- pin t erm inal block connect or on t he EDS's right - side panel. Refer t o t he inst ruct ions and diagram below on how t o connect t he wires t o t he t erm inal block connect or on t he recept or. - 9 - STEP 1 : I nsert t he negat ive (ground)/ posit ive DI wires int o t he / I t erm inals, respect ively. STEP 2 : To keep the DI wires from pulling loose, use a sm all flat -blade screwdriver t o t ight en t he wire-clam p button on the front of the terminal block connect or. STEP 3 : I nsert t he plast ic t erm inal block connect or prongs int o t he t erm inal block recept or, which is locat ed on t he EDS devices' right side. Rotating the Pow er Module The pow er m odule for t he EDS device can be rot at ed t o m ake it easier t o fit your field sit e applicat ion. St e p 1 : Rem ove t he t w o screw s t hat fast en t he pow er m odule t o t he EDS device. St e p 2 : Rem ove t he pow er m odule. St e p 3 : Turn t he power m odule clockwise so t hat t he power, digit al input , and relay out put connect ors can be m oved upwards. St e p 4 : Place t he m odule back on t o t he EDS device and t hen fast en t he t wo screws on t o t he m odule. Com m unica t ion Conne ct ions Each EDS- 4009 Series sw it ch has various t y pes of com m unicat ion por t s: · RJ45 console port ( RS- 232 int erface) · USB st orage port ( t ype A connect or, current ly disabled) · m icroSD card slot (current ly disabled) · 10/ 100BaseTX Et hernet port s · 100BaseFX ( SC/ ST- t ype connect or ) fiber port s Con sole Por t Con n e ct ion The EDS device has one RJ45 console port ( RS- 232) , locat ed on t he front panel. Use eit her an RJ45- t o- DB9 ( see t he cable follow ing w iring diagram s) t o connect t he EDS's console port t o your PC's COM port . You m ay t hen use a console t erm inal program , such as Moxa PCom m Term inal Em ulat or, t o access t he EDS t hat has a baud rat e of 115200. - 10 - RJ4 5 Console Por t Pinou t s Pin D e scr ip t io n 1 DSR 2 RTS 3 4 Tx D 5 Rx D 6 GND 7 CTS 8 DTR USB Conn e ct ion N OTE The USB funct ion is current ly reserved and m ay be required in t he fut ure. I t should be not ed t hat t his port cannot be used for charging any devices. 1 0 / 1 0 0 Ba se T( X) Et h e r n e t Por t Con n e ct ion The 10/ 100BaseT( X) port s locat ed on t he front panel of t he swit ch are used t o connect t o Et hernet - enabled devices. Most users w ill choose t o configure t hese port s for Aut o MDI / MDI - X m ode, in which case t he port 's pinout s are adj ust ed aut om at ically depending on t he t ype of Et hernet cable used ( st raight - t hrough or cross- over ) , and t he t ype of device ( NI C- t ype or HUB/ Sw it ch- t ype) connect ed t o t he port . I n w hat follow s, w e give pinout s for bot h MDI ( NI C- t ype) port s and MDI - X ( HUB/ Sw it ch- t ype) port s. We also give cable w iring diagram s for st raight - t hrough and cross- over Et hernet cables. 1 0 / 1 0 0 Ba se T( x ) RJ4 5 Pinou t s MDI Port Pinouts MDI -X Port Pinouts 8 - pin RJ4 5 Pin Signal 1 Tx + 2 Tx - 3 Rx + 6 Rx - Pin Sig n a l 1 Rx + 2 Rx - 3 Tx + 6 Tx - RJ4 5 ( 8 - pin) t o RJ4 5 ( 8 - pin) St r a ight - Thr oug h Ca ble W ir ing - 11 - RJ4 5 ( 8 - pin) t o RJ4 5 ( 8 - pin) Cr oss- Ove r Ca ble W ir ing 1 0 0 Ba se Fx Et h e rn e t Por t Con n e ct ion The concept behind t he SC/ ST por t and cable is quit e st raight forw ar d. Suppose you are connect ing devices I and I I . As opposed t o elect rical signals, opt ical signals do not require a circuit in order t o t ransm it dat a. Consequent ly, one of t he opt ical lines is used t o t ransm it dat a fr om device I t o device I I , and t he ot her opt ical line is used t ransm it dat a from device I I t o device I , for full- duplex t ransm ission. All you need t o rem em ber is t o connect t he Tx ( t ransm it ) port of device I t o t he Rx ( receive) port of dev ice I I , and t he Rx ( receive) port of device I t o t he Tx (t ransm it ) port of device I I . I f you are m aking your own cable, we suggest labeling t he t wo sides of t he sam e line wit h t he sam e let t er (A-t o-A and B-t o-B, as shown by t he following illust rat ion, or A1-t o-A2 and B1-to-B2) . SC- Por t Pinout s SC- Por t t o SC- Por t Ca ble W ir in g ST- Port Pinouts ST- Por t t o ST- Por t Ca ble W ir in g ATTEN TI ON This is a Class 1 Laser/ LED product . To prevent dam age t o y our eyes, do not st are direct ly int o t he laser beam . - 12 - Reset Button There are t w o funct ions available on t he Reset But t on. One is t o reset t he Et hernet sw it ch t o fact ory default set t ings by pressing and holding t he Reset but t on for 5 seconds. Use a point ed obj ect , such as a st raight ened paper clip or t oot hpick, t o depress t he Reset but t on. This w ill cause t he STATE LED t o blink once a second. Aft er depressing t he but t on for 5 cont inuous seconds, t he STATE LED w ill st art t o blink rapidly. This indicat es t hat fact ory default set t ings have been loaded and you can release t he reset but t on. The ot her funct ion is t o reboot t he device by depressing t he reset but t on for less t han five seconds. Turbo Ring DI P Sw itch Settings The EDS devices are plug- and- play m anaged redundant Et hernet sw it ches. The propriet ar y Turbo Ring prot ocol w as developed by Mox a t o pr ovide bet t er net work reliabilit y and fast er recovery t im e. Moxa Turbo Ring's recover y t im e is less t han 50 m s ( Tur bo Ring 2 ) -- com pared t o a 3- t o 5- m inut e recovery t im e for com m ercial swit ches-- decreasing t he possible loss caused by net work failures in an indust rial set t ing. There are five Hardw are DI P Sw it ches for Turbo Ring on t he bot t om panel of t he EDS device t hat can help set up t he Turbo Ring easily wit hin seconds. I f you do not want t o use a hardware DI P swit ch t o set up t he Turbo Ring, y ou can use a w eb brow ser, t elnet , or console t o disable t his funct ion. N OTE Please refer t o t he Tur bo Ring sect ion in User's Manual for m ore det ail inform at ion about t he set t ing and usage of Turbo Ring V2. Turbo Ring DI P Sw itch Settings The default set t ing for each DI P Sw it ch is OFF. The following t able explains t he effect of set t ing t he DI P Swit ch t o t he ON posit ion. Rem ove t he rubber cover on t he bot t om panel of t he device t o expose t he DI P swit ches. DI P Sw itch Settings DI P 1 DI P 2 DI P 3 DI P 4 DI P 5 ON : Enables t he ON : Enables ON : ON : Act ivat es default " Ring t his EDS as Enables t he DI P sw it ch 2, Co u p l i n g t he Ring default 3, and 4 to (backup)" port Mast er. " Ring con f i g u r e when DI P swit ch 4 Reserved is already enabled. for future use OFF: Enables t he OFF: This default Ring EDS w ill not Coupling" Turbo Ring V2 por t . set t ings. OFF: This OFF: DI P EDS w ill not sw it ch 2, 3, Co u p l i n g be t he Ring be t he Ring and 4 w ill be (prim ary) port Mast er. Coupler. disabled. when DI P swit ch 4 is already enabled. - 13 - N OTE You m ust enable t he Tur bo Ring ( DI P sw it ch 5) fir st before using t he DI P sw it ch t o act ivat e t he Mast er and Coupler funct ions. NOTE I f y ou do not enable any of t he EDS sw it ches t o be t he Ring Mast er, t he Turbo Ring prot ocol w ill aut om at ically choose t he EDS sw it ch w it h t he sm allest MAC address range t o be t he Ring Mast er. I f you accident ally enable m ore t han one swit ch t o be t he Ring Mast er, t hese sw it ches w ill aut o- negot iat e t o det erm ine w hich one w ill be t he Ring Mast er. LED I ndicat ors The front panel of t he Moxa EDS- 4009 Series cont ains several LED indicat ors. The funct ion of each LED is described in t he follow ing t able: D evice LED I n dica t ors LED STATE FAULT P1 P2 Co l o r Gr e e n Red Red Am ber Am ber St a t e D e scr ip t io n When syst em has passed power- On on self- t est ( POST) and is ready to run. Blin k i n g Press t he reset but t on for five seconds t o reset t o fact ory default ( 1 tim e/ sec) set t ings Blin k i n g When pressing t he reset but t on depress for 5 seconds t o reset t o ( 4 tim e s/ sec) fact ory default . Off N/ A The syst em has init ially failed t he On boot -up process · Syst em I nfo. Read Fail or EEPROM infor m at ion error 1. The relay cont act has been t r igger ed On 2. The ingress rat e lim it has been exceeded and t he port has ent ered shut down m ode 3. I nvalid Ring port connect ion When t he syst em boot s up and Off runs correct ly or a user- configured event is not t riggered. On Pow er is being supplied t o pow er input PWR. Off Pow er is not being supplied t o pow er input PWR. Pow er is being supplied t o pow er On input PWR. Off Pow er is not being supplied t o pow er input PWR. - 14 - LED M ST R/ H EAD ( M/ H) CP LR / TAI L Sy st e m LED ( Except PW R) Sy st e m LED ( Except PW R) Co l o r Gr e e n Gr e e n Green + Am ber + Red Green + Am ber + Red St a t e On Blin k i n g ( 4 tim e s/ sec) Off On Blin k i n g ( 4 tim e s/ sec) Off Blin k i n g ( 2 tim e s/ sec) Rot a t e On - > Off Se q u e n t ia lly D e scr ip t io n When t he swit ch is Mast er/ Head/ Root of Tur bo Ring/ Turbo Chain/ Fast RSTP. 1. The swit ch has becom e t he Mast er of Turbo Ring aft er Turbo Ring has gone dow n 2. The swit ch is set as Head of Turbo Chain and Turbo Chain has gone down 3. The swit ch is set as t he Turbo Ring's Mem ber and t he corresponding Ring port is down 4. The swit ch is set as t he Turbo Chain's Mem ber/ Tail and t he corresponding Head-end Chain port is dow n. When t he swit ch is not t he Mast er/ Head/ Root of t his Turbo Ring/ Turbo Chain/ Fast RSTP. 1. The swit ch's ring coupling or dual hom ing funct ion is enabled. 2. The swit ch is set as t he Tail of Turbo Chain. 1. The swit ch is set as t he Tail of Turbo Chain and t he Chain has gone down. 2. The swit ch is set as t he Turbo Chain's Mem ber/ Head and t he corresponding Tail- end Chain port is down. When t he swit ch disables t he coupling or t ail r ole of Turbo Ch a i n . The swit ch is being discovered/ locat ed by t he locat or funct ion. The swit ch is im port ing/ export ing a file via ABC- 02- USB or SD card (current ly disabled) Port s LED I ndicat ors LED 10M/ 100M Coppe r top LED Co l o r Gr e e n St a t e D e scr ip t io n On When t he port is act ive and links at 1 0 0 Mb p s. Blinking When the port's data is being ( 4 t im e s/ se c) t ransm it t ed at 100Mbps. Off When t he port is inact ive or link down. - 15 - LED 10M/ 100M Coppe r bottom LED 100M Fib e r LED Co l o r Am ber Gr e e n St a t e D e scr ip t io n When t he port is act ive and links at On 10Mbps. Blinking When the port's data is being ( 4 tim e s/ sec) t ransm it t ed at 10Mbps. When t he port is inact ive or link Off down. On When the port's data is being t ransm it t ed at 100Mbps. Blinking When the port's data is being ( 4 t im e s/ se c) t ransm it t ed at 100Mbps. Off When t he port is inact ive or link down. Sp e cif ica t ion s I nterface RJ45 Port s 10/ 100BaseT( X) or 10/ 100/ 1000BaseT( X) Fiber Port s 1 0 0 Ba se Fx Console Port RS- 232 ( RJ45) Bu t t on Reset but t on LED I ndicat or s STATE ( S) , FAULT ( F) , PWR1 ( P1) , PWR2 ( P2) , MSTR/ HEAD ( M/ H) , CPLR/ TAI L ( C/ T) , SYNC Alarm Cont act 1 norm ally open elect rom agnet ic relay out put wit h current carrying capacit y of 1 A @ 24 VDC Digital I nput 1 isolat ed digit al input : + 13 t o + 30V for st at e " 1" -30 t o + 3V for st at e " 0" Max. input current : 8 m A Pow er Pre- inst alled Pow er - LV/ - LV- T m odels: PWR- 100- LV Mod u l e - HV/ - HV- T m odels: PWR- 105- HV- I Not e The EDS- 4009 Series support s m odular pow er supplies. The m odel nam es and power param et ers are det erm ined by t he inst alled power m odule. For exam ple: EDS- 4009- T + PWR- 100- LV = EDS- 4009- LV- T EDS- 4009- T + PWR- 105- HV- I = EDS- 4009- HV- T Rat ed Volt age Operat ing Volt age Rat ed Current I f you inst all a different power m odule, refer t o t he specificat ions of t he corresponding m odel. For exam ple, if you replace t he power m odule of t he EDS- 4009- LV- T w it h t he PWR- 105- HV- I , refer t o t he specificat ions of t he EDS- 4009- HV- T. - LV/ - LV- T m odels: 12/ 24/ 48 VDC, redundant dual inputs - HV/ - HV- T m odels: 110/ 220 VDC/ VAC, single input - LV/ - LV- T m odels: 9.6 t o 60 VDC - HV/ - HV- T m odels: 88 t o 300 VDC, 85 t o 264 VAC - LV/ - LV- T m odels: 12- 48 VDC, 1.50- 0.40 A or 24 VDC, 0.70 A - HV/ - HV- T m odels: 110- 220 VAC, 50- 60 Hz, 0.300.20 A or 110- 220 VDC, 0.30- 0.20 A - 16 - Pow er EDS- 4009- 3MSC- LV( - T) m odels: 9.51 W Consum pt ion EDS- 4009- 3MSC- HV( - T) m odels: 12.14 W EDS- 4009- 3MST- LV( - T) m odels: 9.51 W EDS- 4009- 3MST- HV( - T) m odels: 12.17 W EDS- 4009- 3SSC- LV( - T) m odels: 9.51 W EDS- 4009- 3SSC- HV( - T) m odels: 12.34 W I nrush Current Max. 0.58 A @ 48 VDC ( 0.1 1 m s) ( Applied t o - LV m odels) Overload Current Support ed Prot ect ion at I nput Reverse Polarit y Support ed Prot ect ion Connect ion 2 rem ovable 4- cont act t erm inal blocks Physical Characteristics Housing Met al, I P40 pr ot ect ion Dim ension ED S- 4 0 0 9 - 3 M SC( - T) / ED S- 4 0 0 9 - 3 SSC( - T) m odels: 55 x 140 x 120 mm (2.17 x 5.51 x 4.72 in) EDS- 4 0 0 9 - 3 M ST( - T) m odels: 55 x 140 x 132 mm (2.17 x 5.51 x 5.20 in) Weight EDS- 4009- 3MSC( - T) m odels: 821. 5 g ( 1.81 lb) EDS- 4009- 3MST( - T) m odels: 920 g ( 2.03 lb) EDS- 4009- 3SSC( - T) m odels: 932 g ( 2.05 lb) I nst allat ion DI N-rail m ount ing, wall m ounting (with optional kit) Environm ental Lim its Operat ing - 10 t o 60° C ( 14 t o 140° F) for st andard m odels Tem perat ure - 40 t o 75° C ( - 40 t o 167° F) for - T m odels St or age - 40 t o 85° C ( - 40 t o 185° F) Tem perat ure Am bient Relat ive 5 t o 95% ( non- condensing) Hum idit y Alt it u de Up t o 2000 m Not e: Please cont act Moxa if y ou r equire product s guarant eed t o funct ion properly at higher alt it ude. Regulatory Approvals I ndust rial I EC 62443- 4- 1, I EC 62443- 4- 2 Cybersecurit y Safet y UL 61010- 2- 201, EN 62368- 1( LVD) EMC EN 55022/ 24, EN 61000- 6- 2/ 6- 4 EMI FCC Part 15 Subpart B Class A EMS EN 61000- 4- 2 ( ESD) Level 4 EN 61000- 4- 3 ( RS) Level 3 EN 61000- 4- 4 ( EFT) Level 4 EN 61000- 4- 5 ( Surge) Level 4 EN 61000- 4- 6 ( CS) Level 3 EN 61000- 4- 8 Level 4 Shock I EC 60068- 2- 27 Free Fall I EC 60068- 2- 32 Vibr at ion I EC 60068- 2- 6 Rail Traffic EN 50121- 4 ( Way side) Traffic Cont rol NEMA TS2 Warranty - 17 - War r an t y 5 years ATTEN TI ON This device com plies w it h Part 15 of t he FCC rules. Operat ion is subj ect t o t he following condit ions: 1. This device m ay not cause harm ful int erference. 2. This device m ust accept any int erference received including int erference t hat m ay cause undesired operat ion. - 18 -