Installation Guide for ENVIRO models including: Q1, Q1 Fireplace, Fireplace
Q1FP-InstallGuide - Urban Fireplaces
Q1 FIREPLACE Installation Reference Guide REFER TO OWNER'S MANUAL FOR SPECIFIC INSTALLATION REQUIREMENTS AND ADDITIONAL PRODUCT INSTRUCTIONS Minimum Framing Dimensions Note: When framing the unit, care must be taken to consider the final floor thickness, the bottom of the fireplace must sit flush with the finished floor to ensure proper fit of the surround components Width Framing Height - Rear Vent Framing Height - Top Vent Gas Inlet (Distance from Back) Depth (No Surround Panel) 25¼" 641 mm 35¼" 895 mm 41" 1041 mm 6 15/16" 176 mm 17 15/16" 456 mm *Minimum dimension with only an elbow off the top. Any additional vertical rise added will increase the enclosure height accordingly. Gas Inlet 615/16" 176 mm Wood Framing Stud Steel Framing Stud Top Vent 41" 1041 mm 25½" 648 mm 25¼" 641 mm Rear Vent 35¼" 895 mm Clearance to Combustibles A - Side of unit to side wall 7" 254 mm B- Minimum clearance to mantel height See Chart See Chart C - Front of door to edge of floor protection 12" 305 mm D- Minimum aclove width 34" 864 mm A B D C Mantle & Non-Combustible Clearances: 12" (305 mm) Mantle 2" (51 mm) Mantle 10" (254 mm) Non-Combustible Facing 1/2" (12.7mm) thick non- combustible facing 7" (178 mm) minimum from side of door to side wall 41" (1041 mm) minimum from bottom of unit 35" (889 mm) minimum from bottom of unit 1¼" (32mm) thick non- combustible floor 12" (305 mm) minimum from wall If hearth is flush with flooring Minimum Venting Requirements This appliance uses a 4" (101mm) exhaust / 6 5/8" (168mm) air intake vent pipe system. For safe and proper operation of the appliance follow the venting instructions exactly. Deviation from the minimum vertical length can create difficulty in burner start-up and sooting. Allow several minutes for the flame to stabilize after ignition under extreme vent configurations. It is recommended for vent lengths that pass through unheated spaces (garages, attics, crawl spaces) be insulated to minimize condensation. See manual for more info. *Note: Glass Units can NOT be rear vented. Fireplace Dimensions Top Vent 17 13/16" (452mm) 4 1/2" (114mm) 25 1/4" (641mm) 16 7/8" (429mm) 6 5/8" (168mm) 4 3/8" (112mm) 15 1/2" (387mm) 14.250" (362mm) 15 1/4" (387mm) 16 7/8" (479mm) 25" (635mm) 20" (508mm) 18 3/4" (476mm) 3 5/8" (93mm) 25 1/4" (641mm) 27 5/8" (702mm) 24 3/4" (627mm) 16 1/2" (476mm) 18 3/4" (420mm) 21" (533mm) 25 3/16" (640mm) 5 3/8" (136mm) Rear Vent 25 1/4" (641mm) 25 1/4" (425mm) 6 5/8" (168mm) 4 3/8" (112mm) 21 1/2" (548mm) 42 ½" [1079mm] Framing clearance of 41" + 1 ½" for flat 2x4 TOP (MIN) 36 ¾" [933mm] Framing clearance of 35 ¼" + 1 ½" for flat 2x4 REAR (MIN) 1715/16" [547mm] Based on ½" building material Fiberglass Insulation M A N T L E H E I G H T FROM UNIT BOTTOM 33" [838mm] TOP (MIN) 21.5" [548mm] REAR Mantel Projections Note: Mantle height dimensions are based from the bottom of the appliance. 42" 41" 40" 39" 38" 37" 36" 2" MANTLE 35" 12" MANTLE 1 2 3 4 5 6 7 8 9 10 11 12 Rear Vent Conversion Step 1: Using a T20 screwdriver remove the vent collar, base plate, cover plate and exhaust spigot (28 screws total) Vent Collar Base Plate Exhaust Spigot Clean Face Install The Q1 is shipped with the Tiling Flanges packaged at the back of the unit. To install as a fireplace you must use the Tiling Flanges and Rear Standoffs. The Tiling Flanges double as the Side Standoffs. Take the three flanges out of the packing foam and install them onto the unit in the desired position. There are three positions the Tiling Flanges can be set to Measure the non-combustable and tiling material to determine which setting will work best for the install. With a T20 screwdiriver, install the flanges as shown below using the T20 screws provided in the Manual Bag. The top and bottom screws that hold the surround mounts will need to be removed and re-used to install the Tiling Flanges. Cover Plate Re-use Screw Switch the removed parts around as shown below and re-install all 28 screws. To correctly install the base plate keep the locating notch on each side at the bottom. Also note the exhaust spigot uses a lower set of holes when setup as a rear vent. 17¾" .875" Surround Mount Re-use Screw 17½" 1.375" 16¾" 1.875" Use lower set of holes Setting 1 Setting 2 Setting 3 Victorian Face Installation · Surround Mounts must be swapped and installed prior to finishing. · Finishing opening must be spaced ½" off the cabinet sides for surround mounts. ½" ½" 18 3/8" Total Depth 1½ " Thick Finishing 16 13/16" Framing Depth Locating Notch Tiling flanges at furthest back settingPDFium PDFium