User Guide for PEDROLLO models including: CKm 50, CK 50, CKm 50-BP, CK 50-BP, CK Self Priming Liquid Ring Electric Pumps, CK, CK Electric Pumps, Self Priming Liquid Ring Electric Pumps, Liquid Ring Electric Pumps, Liquid Ring Pumps, Pumps, Electric Pumps

Andrea Geroli

Self-priming liquid ring electric pumps

30 avr. 2024 — INSTALLATION AND USE. Designed for pumping diesel/naphtha and clean water free from abrasive particles and non-corro- sive liquids that do not harm the ...2 pages

Self-priming liquid ring electric pumps - Pedrollo S.p.A.

3 1 4 5 6 2 260 41 70 80 152 128 24 152 ¾" 75 100 120 7 ¾" CONSTRUCTION FEATURES 1 Pump body Cast iron with ISO 228/1 threaded ports 2 Motor bracket Aluminium with brass cover with front anti-locking shim function (patented) 3 Impeller Brass with open radial vanes 4 Mechanical seal Type Materials AR-12V Ceramic / Graphite / Viton 5 Shaft Stainless steel AISI 431 6 Electric motor CKm: single ...

Technical sheet

CK | Pedrollo S.p.A.

CK EN 50Hz
CK

Self-priming liquid ring electric pumps
Clean water

Agricultural use

INSTALLATION AND USE Designed for pumping diesel/naphtha and clean water free from abrasive particles and non-corrosive liquids that do not harm the pump's components. Their specific operating mechanism makes them an excellent solution when a compact self-priming pump is required or when the flow of the liquid is irregular or mixed with air.
APPLICATION LIMITS
· Suction head up to 9 m (HS) · Liquid temperature between -10 °C and +90 °C · Temperature for diesel/naphta up to +55 °C · Ambient temperature up to +40 °C · Maximum working pressure 6 bar
AVAILABLE UPON REQUEST  Mechanical seal options available

CURVES AND PERFORMANCE DATA ­ HS=0 m

50 Hz

0

1

2

3

4

5

6

7

8

9

10 1U1S g.p.m.

0

1

2

3

4

5

6

7

8

9Imp g.p.m.

35

feet

CK50

30

100

25 CK50-BP
20

Brass

75

15

50

ABSORPTION
TYPE Single-ph. CKm 50 CKm 50-BP

VOLTAGE 230 V 3.0 A
2.7 A

Head H (metres) 4

10

5

0

0

5

10 15 20 25 30 35

0

0.5

1

1.5

2

Flow rate Q 4

(*) CK 50-BP = performance curve with by-pass

25
0
40 l/mi4n5
2.5 m³/h

TYPE Three-ph. CK 50
CK 50-BP

VOLTAGE

230 V - t

400 V - s

2.1 A

1.2 A

1.7 A

1.0 A

TYPE

POWER (P2)

m³/h

0

Q

Single-ph. Three-ph. kW HP 1~ 3~ l/min 0

CKm 50 CK 50 CKm 50-BP CK 50-BP

0.37 0.50

35

IE2 IE3 H metres

0.25 0.33

20

Q = Flow rate H = Total manometric head HS = Suction height

0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4

5 10 15 20 25 30 35 40

31 27 24 20 16 13 9

5

20 20 20 20 16 13 9

5

Performance curves comply with EN ISO 9906 Grade 3B tolerance limits.

50 Hz | CK

DIMENSIONS (mm)
260

75 ¾"

24 ¾"

152

152 128

41

70

TYPE Single-phase Three-phase

CKm 50

CK 50

7 80

PORTS

DN1

DN2

¾"

¾"

100 120

WEIGHT (kg)

1~

3~

7.3

7.3

PALLET CAPACITY
160

CONSTRUCTION FEATURES

1 Pump body

Cast iron with ISO 228/1 threaded ports

2 Motor bracket

Aluminium with brass cover with front anti-locking shim function (patented)

3 Impeller

Brass with open radial vanes

4 Mechanical seal

Type
AR-12V

Materials
Ceramic / Graphite / Viton

5 Shaft 6 Electric motor

Stainless steel AISI 431
CKm: single-phase 230 V - 50 Hz with winding integrated thermal motor protection. CK: three-phase 230/400 V - 50 Hz
 Pumps are equipped with high-efficiency motors (IEC 60034-30-1) class IE2 for single-phase models class IE3 for three-phase models
­ Continuous running duty S1 ­ Insulation: class F ­ Protection rating: IP X4

2

1

3

4

5

6

CK | 50 Hz

