Instruction Manual for KEMLAN models including: CUBE, Slow Combustion Wood Fireplace, CUBE Slow Combustion Wood Fireplace, Wood Fireplace, Fireplace
KEMLAN CUBE - Jetmaster Fireplaces Australia
20 lug 2022 — NOTE:- When installing this unit onto a table, make sure to leave the. 4x bolts in place. The bolts are necessary to allow air flow to the.
File Info : application/pdf, 15 Pages, 1.96MB
DocumentDocumentSpecialists in fireplace design and manufacture KEMLAN CUBE INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: INSTALLER, PLEASE LEAVE THESE INSTRUCTIONS WITH THE UNIT ON COMPLETION. 10 YEAR FIREBOX WARRANTY The firebox is covered by a 10 year warranty. Other parts are covered by a one year limited warranty. Head Office 13 French Avenue, Brendale, Queensland 4500 Telephone PH: (07) 3490 5500 Facsimile FAX: (07) 3490 5520 Website: - www.jetmaster.com.au Business hours: - Monday to Thursday 7:30am-4:00pm. Friday 7:30am-2:00pm Email: - sales@jetmaster.com.au F E DIMENSIONS KEMLAN CUBE H B C 450 D A G A B C D E F G H MEASUREMENT 522 499 705 510 218 353.5 568 526 20/07/2022 Ver.18 2 MINIMUM CLEARANCES FOR THE KEMLAN CUBE INSTALLED WITH DEFAULT FLUE KIT A B E K H D G C C F F I K J MINIMUM CLEARANCES: MEASUREMENT A B C D E F G H I J K 120 300 125 338 654 540 1004 875 1114 570 300 STEEL BENCH MEASUREMENTS: 1007 875 TOP VIEW 40 260 927 300 FRONT VIEW 20/07/2022 Ver.18 3 HEARTH MEASUREMENT 120 90 Cube B A A. UNIT HEIGHT ABOVE FLOOR 300 MIN. B. HEARTH DIMENSION FORWARD OF UNIT 300 20/07/2022 Ver.18 4 AIR GAP DETAIL NOTE:- When installing this unit onto a table, make sure to leave the 4x bolts in place. The bolts are necessary to allow air flow to the underside of the firebox. The removal of these bolts will lead to overheating to the underside of the unit and eventually cause malfunction. The removal of these bolts could void your warranty. 20/07/2022 Ver.18 5 AIR GAP DETAIL Air gap Table There must be an air gap between the bottom of the appliance and the top of a table. This is necessary to allow air flow to the appliance. Meridian base The bolts will need to be removed when the appliance is installed onto a meridian base. However, the same bolts must be used to fix appliance to the meridian base. 20/07/2022 Ver.18 6 INSTALLATION INSTRUCTION KEMLAN CUBE FLAT CEILING INSTALLATION A Pop rivet or screw brackets to the outside of the outer casing DETAIL A Short tube fits into flue pipe. All flues should be trimmed level Flash roof to outer casing (supplied by installer) DETAIL c plain 10" Flue crimped 8" Flue 6" Flue Support outer flue with Brackets supplied All 8"-10" assembled flues must have the crimps pointing upwards B DETAIL c 25 25 Run a bead of silicone down the vertical seam of the outer casing to the flashing Bracing supplied by installer c All casing flue pipes must be connected with pop rivets supplied by installer Stainless steel flue pipe. All flue pipes must be connected with pop rivets supplied by installer Flue system to be installed to suit AS/NZS 2918.2001 12mm Air gap Ceiling trim DETAIL B Vented cap NOTE:- When Decromesh / Heatshield is fitted, it must finish a minimum of 600mm below the ceiling or extend through the ceiling drop box into the outer flue casing D crimped plain All 6" assembled flues must have the crimps pointing downwards DETAIL D 8" Decro with double heat shield 20/07/2022 Ver.18 7 INSTALLATION INSTRUCTION KEMLAN CUBE RAKED CEILING INSTALLATION Pop rivet or screw brackets to the outside of the outer casing DETAIL A Short tube fits into flue pipe. All flues should be trimmed level plain crimped 10" Flue 8" Flue 6" Flue Flash roof to outer casing (supplied by installer) B All 8"-10" assembled flues must have the crimps pointing upwards DETAIL c 25 25 12mm Air Gap Raked ceiling trim 150 8" Decro with double heat shield DETAIL B Vented cap NOTE:- When Decromesh / Heatshield is fitted, it must finish a minimum of 600mm below the ceiling or extend through the ceiling drop box into the outer flue casing 20/07/2022 Ver.18 A Run a bead of silicone down the vertical seam of the outer casing to the flashing All casing flue pipes must be connected with pop rivets supplied by installer c Bracing supplied by installer Stainless steel flue pipe. All flue pipes must be connected with pop rivets supplied by installer Flue system to be installed to suit AS/NZS 2918.2001 D crimped plain All 6" assembled flues must have the crimps pointing downwards DETAIL D 8 SUPER NOVA / CUBE /TEMPO GRAND BAFFLE PLATE INSTALLATON INSTRUCTIONS 1. MAKE SURE TO INSTALL AIR TUBE AS REQUIRED. THE OPENING ON THE TUBE END NEEDS TO BE AGAINST THE BACK WALL. ALL ROUND EXIT HOLES MUST BE POINTING TO THE BOTTOM OF THE FIRE BOX OR THE SIDE WALLS. 2. CERAMIC BAFFLE PLATES SIZE 230mmX240mm. INSTALL THE BAFFLE PLATE 230mm FRONT TO BACK, 240mm SIDE TO SIDE. GET BAFFLE PLATE INSIDE THE FIREBOX AND TILT ON AN ANGLE. PUSH BAFFLE PLATE OVER THE AIR TUBE 3. THEN MOVE SIDEWAYS UNTIL SUPPORTED BY THE SUPPORT PLATE AND TOUCHING THE SIDE WALL 20/07/2022 Ver.18 4. REPEAT THE PROCESS FOR THE OTHER SIDE. PUSH BOTH BAFFLE PLATES UNTIL IT IS AGAINST THE SIDE AND REAR WALLS. 9 20/07/2022 Ver.18 10 20/07/2022 11 Ver.18 20/07/2022 Ver.18 12 INSTALLATION INSTRUCTIONS MINIMUM HEIGHT OF FLUE SYSTEM EXIT INSTALLATION TO COMPLY WITH AS/NZS 2918 ANY NEARBY STRUCTURE 6000 3000 OR LESS MORE THAN 3000 600 MIN 3000 INCREASE AS NECESSARY UNTIL NOTHING WITHIN 6000 OF THE FLUE TOP 1000 MIN IF CLEAR WITHIN 3000 OF TOP OF FLUE 3000 OR LESS MORE THAN 3000 600 MIN 3000 20/07/2022 INCREASE FROM 1000 MIN UNTIL CLEAR WITHIN 3000 OF TOP OF FLUE DIMENSIONS IN MILLIMETRES Ver.18 13 20/07/2022 Ver.18 14 WARRANTY 1. Kemlan wood heaters carry a warranty on the 6mm firebox for a period of ten (10) years. 2. This warranty also covers other components of the heater for a period of one (1) year. These components include the baffle plate, handle assembly, secondary air tubes and fan. 3. Kemlan's warranty covers the wood heaters against defects in materials and manufacture. 4. THIS WARRANTY DOES NOT COVER 4.1 Failure to comply with manufacturer's operation instructions. 4.2 Normal wear and tear or damage caused by incorrect installation. 4.3 Any form of rust and/or corrosion to the painted finish of the heater. 4.4 Damage to the glass in the door, if the damage is caused by impact or misuse. 4.5 The cost of collection and delivery of the wood heater and/or parts. 4.6 Damage caused by water ingress. 4.7 Cost of removal of defective heater or re-installation of replacement heater. 4.8 Failure to use fireplace components supplied by Kemlan Industries Pty Ltd. 4.9 Cost of inspection for damaged heater. 5. CLAIMS 5.1 (I) Kemlan will provide a full replacement of the heater in the first five years after installation. (ii) Replacement in the subsequent five years (i.e. sixth to tenth year after installation will be on the following basis. Owner will pay fifty percent of the current retail price, if the claim is made in the sixth year tenth year after purchase. 5.2 Replacement of heater subject to all conditions in section four of warranty. 5.3 Should any defects occur, contact the Kemlan distributor from whom you purchased the heater. 5.4 Under this warranty the defective parts will be repaired or replaced, free of charge. 6. The fireplace installation must comply with the relevant local statutes, ordinances, regulations and by-laws. 7. THIS WARRANTY IS VOID IF: 7.1 The appliance has been over-fired or operated in atmospheres contaminated by chlorine, fluorine or other damaging chemicals. Over-firing can be identified by, but not limited to, warped plated or tubes, rust coloured cast iron, bubbling, cracking and discolouration of steel or enamel finishes. PLEASE COMPLETE AND RETAIN THIS SECTION FOR YOUR RECORDS Purchased from: ....................................................................................................... Address: .................................................................................................................... Date of Purchase: ...................................................................................................... 20/07/2022 Ver.18 15