USER GUIDE HP 100 / HP200 / HP200E
HOTEL DOOR LOCK

Version 1.0

- 1 -

Table of Contents
1. Understanding HP100, HP200, HP200E Hotel Door Lock ...... 3
1.1 What is HP100, HP200, HP200E Hotel Door Lock?........................... 3 1.2 Features by model.............................................................................. 3 1.3 Operation cards .................................................................................. 5
2. Types of Lock Operating Scenario ........................................ 6
2.1 Guest Card issue .................................................................................. 6 2.2 Using RFID card ................................................................................... 8 2.3 Using Smartphone ................................................................................ 9
2.3.1 Synchronizing guest card to Smartphone.................................................... 9 2.3.2 Using Mobile Bluetooth (Esmart Sync) ..................................................... 11
3. Lock Operation ...................................................................... 15
3.1 Lock Installation .................................................................................. 15 3.2 Lock Setting(LIS) card ........................................................................ 18
Main Item Description .......................................................................................... 18
3.4 Open in Emergency ............................................................................ 20
Main Item Description .......................................................................................... 21
3.5 Low Battery warning and battery change ......................................... 22
4. Specification .......................................................................... 24
5. Indication Instruction............................................................. 24
ANNEX A Beep & LED Table & Trouble Shooting .................... 25
6 Regulatory Statement ............................................................ 27

Version 1.0

- 2 -

1. Understanding HP100, HP200, HP200E Hotel Door Lock
1.1 What is HP100, HP200, HP200E Hotel Door Lock? - HP100, HP200, HP200E hotel door lock is operated by either 13,56 MHz RF keys or Mobile. - HP100, HP200, HP200E can work as both offline (standalone) and online mode. - To set HP100, HP200, HP200E as online system, additional peripherals such as Access point, Server and client software are necessary.

1.2 Features by model

FEATURES

HP100

HP200

HP200E

Front Design

e-Paper display Touch Key (12 Key)
Support Mortise
Support deadbolt Panic release Mechanical key override Low battery indicator

ANSI(top), ANSI Standard(bottom), Euro #6 Yes Yes
Yes
Yes

Yes ANSI(top), ANSI Standard(bottom), Euro #6 Yes Yes
Yes
Yes

Yes -
ANSI(top), ANSI Standard(bottom),
Euro #6 Yes Yes
Yes
Yes

Version 1.0

- 3 -

Power supply Battery Lifetime

4 x AA

4 x AA

4 x AA

(Alkaline battery)

(Alkaline battery)

(Alkaline battery)

18 months for wireless 18 months for wireless 18 months for wireless

online lock

online lock

online lock

24 months for standalone 24 months for standalone 24 months for standalone

lock

lock

lock

Block/Unblock card

Yes

Yes

Yes

Online Intrusion alarm
(over 3 times of unauthorized open
trial) Online Ajar alarm Instant Stay Extension Instant Room change Automatic unlock/lock Passage mode
Remote audit trail
Remote Maintenance reporting

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes (Online:

Yes (Online:

Yes (Online:

Unlimited/Offline:2,000 Unlimited/Offline:2,000 Unlimited/Offline:2,000

events)

events)

events)

Yes

Yes

Yes

Mobile Key Access

Yes

Yes

Yes

Version 1.0

- 4 -

1.3 Operation cards

Card Name

Description

Card type

· Security Key value to be loaded to locks at scanning. Key
· Then, the locks will accept only the RFID cards which have the card
same security key value.

Setup · Lock will be programmed with various options at scanning.

card

· Setup card can be set from PTHMS Client Pro Software

Staff

· For staffs access card

card

· Set name/title/authority/holiday, etc.

Emergency · All rooms can be opened with an emergency card.

card

Particular attention should be paid to loss

Blocking card
Clearance

· A Blocking card is used to block all user groups on a particular door. For example, this card is used to block all groups except Maid by reading the blocking card when Maid cleans the Fitness Club.
· A card that cancels the registered Guest Card. This card can only

Mifare 1KB

card

be used after the Employee (Maid) Card has been read.

Passage · A card to unlock the door until the specified time for the defined

Mode

door.

card

· It is operated by the Toggle concept in order to display "D.N.D" on

the door with the card provided in each room.

Privacy It can be operated only when Guest Card is registered.

card

In order to delete it, Maid must read Maid Card/Employee Card and

then Erase Card/Power-Down Card to cancel it, or it will be

automatically cancelled when a new guest card is registered.

Audit trail · A card for collecting usage histories for each lock. (Up to 2000

Combi

card

cases)

card

· A card to read the setting value of each door.

(Mifare

Lock info

+

card

Kona

COS)

Version 1.0

- 5 -

2. Types of Lock Operating Scenario
HP100/HP200/HP200E Hotel Door locks are designed to work for the various operation requirements by simple set up process. Following operation modes can be set by hotel staffs and guests.
2.1 Guest Card issue
Guest issue It is a screen for checking in and issuing a guest card for the guests who stay in a
general room.

Main Item Description
Item Room No.

Description Room Number you just chose to check-in will be shown. - Room number must be at least 3 digits for floor
number and room number. . Ex) Floor1, Room1  "101"

Version 1.0

- 6 -

Check In Check Out No. of cards Issue to Mobile
E-Mail
Option (Combo box)

Floor10, Room2  "1002" Floor11, Room12  "1112"  If you enter more than 10 floors and input 1~9
rooms, please note that it will be recognized as another floor when the number is below 4 digits. Check in date and time Check out date and time Number of guest card you are going to issue Guest's name Guest's mobile number (Smartcode will be sent to this number) Guest's E-mail address (Mobile key app link will be sent to this address) If ticked, it means it will be available for the option. - Deadbolt: Deadbolt availabilty - Breakfast: Breakfast option - Full Gate: Gate that the card will be accepted
Individual gates can be ticked separately. - Elevator Full floor: Accessibility of the elevators(floor)
Individual floors can be ticked separately. - RF Card Issue: If you want to issue the RF card - Smart-code Issue: If you want to issue smartcode to the guest's mobile phone. - Mobile key Issue: If you want to issue mobile key to the guest. - Check-out: If you are checking out.

If you have selected the item you want to use, you can place the card to be issued

on the DE-620 Reader and press

button to issue the card.

If you are issuing multiple cards, you will be prompted to put the next card on the reader.

If the card is lost, reissue the card in the Reissuance guest card section(by clicking mouse right-button on the room number).

Version 1.0

- 7 -

2.2 Using RFID card - Once successfully complete above steps, guest card may scan the lock and it will work nice and easy.

Version 1.0

- 8 -

2.3 Using Smartphone - Passtech's all hotel door locks are wireless online, which means they are operated not only with RFID credentials, but also with your smartphone by incorporating an innovative BLE mobile access technology. The solution provides more advanced and efficient approach towards managing the rooms at various kinds of venues where requires highest level of security
2.3.1 Synchronizing guest card to Smartphone

1. Go visit "Google Play Store" or "APP Store", and search "PASSTECH". 2. Download Application (Passtech Mobile Cloud ­ Android / Passtech Cloud
Mobile Key ­ Apple) and install it in the guest's smartphone. 3. When execute Application, your guest will see below display screens. 4. From this step, it is simple and important to sync to mobile. When the guest
enters the hotel room with RFID guest Card, the guest opens the door at first time. 5. Then guest should open the door from inside to outside of the room. 6. Scan Guest card on the lock 2 times.(Described above &&)

Version 1.0

- 9 -





7. Right after scan the Guest card, press "Register" button on their Application. (Displayed as above picture )
8. The screen will display guest card information as above picture. (Displayed as above picture )

Version 1.0

- 10 -

2.3.2 Using Mobile Bluetooth (Esmart Sync)
- Check your room number and valid time, if those are all set successfully, press Red button on the display, then it will open using BLE communication.

Version 1.0

- 11 -

Display

Explanation Guest will mainly use this display.
- Operation Mode - Lock Number - Valid time - Open command

This is display for log history. All history of their logs will be displayed, it's so, the guest shouldn't require to visit front desk for ask their log history.

Version 1.0

- 12 -

This is for register the lock on mobile.
This is display for setting mobile option such as sound on/off, vibration on/off and Bluetooth sensitivity, etc.

Version 1.0

- 13 -

This is application information display.

Version 1.0

- 14 -

3. Lock Operation
HP100, HP200, HP200E can be accessed with both RF tags and BLE Mobile.
3.1 Lock Installation - Dimensions

<ANSI STD (Bottom)>

Version 1.0

- 15 -

<ANSI Top>

<Euro #6>
Version 1.0

- 16 -

- Handles
- Installation -

 Recommended installation is executed by installation experts.

Version 1.0

- 17 -

3.2 Lock Setting(LIS) card A screen for issuing a Setup card for setting installation information in each door lock after the locks are installed.

Group Hotel/Lock Info.

Item Build No.

Floor No.

Room No.

Setting value

Main Item Description

Description

Building No.(1~99)

 Applicable only if you select the corresponding letter in the Combo

Box.

Floor No.

 Applicable only if you select the corresponding letter in the Combo

Box.

Room No. (From ~ To)

 Applicable only if you select the corresponding letter in the Combo

Box.

From/To

Value

of

selected

Version 1.0

- 18 -

Increase Hotel ID

Build/Floor/Room Number of selected rooms - Shows the Hotel ID registered in Account's Hotel info. - If the Issuer Key is same and the Affiliate
ID is wrong, you can select whether to accept it from the Listbox.

Group Hotel/Lock Info.
Time Schedule
Option

Item Setting date/time
Increase Sec Normal

Description - If you select Current day/time, it is set to
the current time of the computer. - If not selected, it is set to the time specified by the user. It sets the time to set the lock time by increasing the time by several seconds everytime Door lock is set. Uses Normal Schedule of Access Time
schedule set in Staff Card.

Holiday1/ Holiday2/ Holiday3/ Holiday4/ Holiday5 Lock beep flag Latch stay time
Status send time
Usage cancel card EEPROM set flag EEPROM Usage Access status flag

Use the corresponding Holiday Schedule in the Access Time schedule set in the Staff Card.
Use Buzzer on Door The Latch time of staying (sec) after opening. The time(minute) for transmitting the current state of the Door lock from time to time. Use of Cancel card(for Checking) Not currently enabled.(Future) Usage #1/#2 (Future) Future

Version 1.0

- 19 -

Accept Card Setting flag

Accept card Setting flag

Type of Staff card accepted from Door Lock Whether to apply what you checked in the Option to the Door lock.

3.4 Open in Emergency In case of Emergency such a fire or any types of disasters that require urgently evacuate the building; there are two ways to open all locks.
- Emergency Open (Client Software)

- From Client Software, in right hand corner, you may see as above picture. - Click "Open" and "Control send" button, then it will send the command
AP(Access Point) and when you touch the lock to wake it up, then the lock will be open.

Version 1.0

- 20 -

- Emergency Card Emergency card is a card with unlimited access, which means you have unlimited access to all the doors of the hotel. If you lose the card, you must immediately register the BL so that it cannot be used. Note that an Emergency card must be issued at installation time, but you may issue an emergency card later if necessary. It is important to keep Emergency card in a safe place when not in use. The Emergency card is opened at the time of usage and remains open until the card is used to close the door. In other words, it performs the Toggle function. If the door is open, it can also be closed by the close door command from the system.

Main Item Description

Group

Item

Description

General

Card Holder

Guest Card Holder Staff Name

User group

Card type by Staff

No. of days

Date of use

Expiration time

Expiration date and time

After selecting the card holder, you can place the card to be issued on the DE-620

Version 1.0

- 21 -

Reader and press

button to issue the card.

3.5 Low Battery warning and battery change

This is the place to manage the door status code and it is mainly used to display the status information about the open/close of the Door Symbol. When you've set your account as above, the Low-Battery alarm will display. Recommended to change the battery in case of display "Low Battery".

Version 1.0

- 22 -

- In Case of battery is off with lock closed status, use mechanical key to open the door and change the battery.

CAUTION
RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE.
DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS

Version 1.0

- 23 -

4. Specification

Item Material Communication
Security Door open
Power Supply RFID Indicator Dimension
Operation TEMP Battery life Certification

Spec Stainless Steel 2.4Ghz Wireless(ONLINE COMUNICATION) BLE(MOBILE KEY) AES128 Touch-key (PIN, HP200 Only), Mobile Key, RFID CARD, Wireless control AA*4 6V DC(Alkaline) Battery Mifare Classic & Desfire at default, ISO14443 Type A
Buzzer, Red/Green LED, E-PAPER (HP200E only) HP100 : 56mm*56mm HP200, HP200E : 58mm * 87mm * 11.5mm (W*H*D) 0 °C to 50 °C 1.5year(online) 2year(stand alone) CE, FCC

5. Indication Instruction

1) Guest Card Open : One time Beep sound / Green LED 0.5sec 2) Successful programming : A melody (Do,Mi,So,Fa) / Green LED 0.5sec 3) Indicate for mistake : Three times Beep sound / Red LED three times. 4) Low voltage : Beep 3 times

Version 1.0

- 24 -

ANNEX A Beep & LED Table & Trouble Shooting

No

Lock Status

Sound

LED

1 Battery Change 2 Succeed Key Card

So,La,Ti,Do,La Do,Mi,So,Fa

3 Succeed Setup Card programming

Do,Mi,So,Fa

Succeed registration Smartphone on

4

Do,Mi,So,Fa

the Hotel Lock

5 Succeed Clearance Card

Do,Mi,So,Fa

6 Succeed Debug Card

Do,Mi,So,Fa

7 Succeed Staff Card 8 Low Battery Detect 9 Succeed Emergency Card

Do,Mi,So,Fa Beep 3 times Do,Mi,So,Fa

10 Succeed Maintenance Card

Do,Mi,So,Fa

11 Succeed Cancel Card

Do,Mi,So,Fa

12 Succeed Blocking Card

Do,Mi,So,Fa

13 Succeed Lock Info Card

Do,Mi,So,Fa

14 Succeed Privacy Card

Do,Mi,So,Fa

Over events of memory from Lock

15

Beep 4 times

Info Card

Green 0.5sec Green 0.5sec Green 0.5sec Green 0.5sec Green 0.5sec Green 0.5sec
Green 0.5sec Green 0.5sec Green 0.5sec Green 0.5sec Green 0.5sec Green 0.5sec
-

Succeed collecting 100 events Audit

16

Beep 1 time

-

Trail

Additional Info.
Total 2,000 events
Total capability is 2,000 events, Total 20 times Beep sound.

Version 1.0

- 25 -

No

Lock Status

Sound

LED

Succeed collecting all, 17
Audit Trail Card

Do,Mi,So,Fa

-

18 Open the door using Guest Card

Beep 1 time

Green 0.5sec

19 RTC Date Time setting failure

So,La,Ti,Do,La

-

Automatically setting default date &

20

So,La,Ti,Do,La

-

time (2010.Jan.01), due to RTC error

21 Latch Open failure

Do,Re 3 times

-

Latch Open failure and retrial is

22

Do,Re 3 times

-

failed again

Sensing Latch Push from opening

23

-

inside of the door

Green 0.5sec

24 Sensing forcibly Open

Do,Re 1.5sec

-

25 State of Read Error any cards

26 State of Write Error any cards

27 State of any other error of all cards

28 State of valid expired for all cards

29 Mismatched Guest Card room No.

Unauthorized/inaccessible 30
Staff Card's room No. Unauthorized/inaccessible

Beep 3 times

NG 3

31 Staff Card's where the lock has been

set for Privacy

32 Undefined type of card reading error

33 In case of scanning blocked card

34 Deadbolt Rejection error

35 Multiple trial "One Time Card"

State of registration for smartphone. 36 (Open from inside and scan Guest
card two times)

Beep 2 times

Repeat "Green"/"Red

37 Connect Front and Body of the lock Beep 2 times

-

Additional Info.

Version 1.0

- 26 -

6 Regulatory Statement
The revised User Manual does not contain the FCC required warning statements.
a. Rule Part 15.19(a)(3): This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
b. Rule Part 15.21: The users manual or instruction manual for an intentional or unintentional radiator shall caution the user that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
· Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. · Consult the dealer or an experienced radio/TV technician for help
Responsible Party ­ Cardcom
Address: 1301 S. Beach Blvd. Ste-P La Habra, CA 90631 Tel.: 562-943-6300 E-mail: passtech@esmartlock.com

Version 1.0

- 27 -


Microsoft Word 2016