User Guide for Co-Dx models including: Logix Smart SARS-CoV-2 Direct Saliva, Logix Smart SARS-CoV-2, Direct Saliva, Saliva
PD-2-1 3 uick tart uide (continued) for sin te oi Smart SRSo iret Salia RO rout OSR an In the Co-Dx Box software, click New. Select an assay template and click OK. Under Run Setup, select Samples and type sample information in the
Instructions For Use - Co-Diagnostics, Inc.
In the Co-Dx Box software, click New. Select an assay template and click OK. Under Run Setup, select Samples and type sample information in the appropriate ...
Quick Start Guide for Using the Logix SmartTM SARS-CoV-2 Direct Saliva RUO Product (COVDS-R-003 and -004) 1 Plate the Master Mix a. Load the Co-Dx Box software. e. Add 10 µL of MM into every well that will be used (1 well for NC, 1 well for positive control [PC], and 1 well for each sample). b. In the Clean area, clean work surfaces with water > 10% bleach > water > 70% alcohol (in that order), or another equivalent method of cleaning that disinfects and degrades nucleic acids. c. Thaw the master mix (MM) and the nuclease-free water (NFW) (for the no-template control [NC]), on ice. f. Pipet 10 µL of NFW into only the NC well and cap the NC well. Perform in Clean Area Perform in Clean Area d. Briefly vortex and centrifuge the MM and NFW reagents. g. Place reagents back into the freezer. PID-8792-01 1 Quick Start Guide (continued) for Using the Logix SmartTM SARS-CoV-2 Direct Saliva RUO Product (COVDS-R-003 and -004) 2 Plate Samples and Positive Control (PC) a. Load the Co-Dx Box software. f. Add 10 µL of the sample extract to the appropriate wells and cap the sample extract wells. b. In the Positive area, clean work surfaces with water > 10% bleach > water > and 70% alcohol (in that order). g. Add 10 µL PC to the PC well and cap the PC well. Perform in Positive Area Perform in Positive Area c. Thaw the PC on ice. h. Place capped tubes in the thermocycler, in appropriate locations and fill the rest of the carousel with blank tubes. d. Briefly vortex and centrifuge all reagents. e. Perform sample extraction, either using RNA extraction or lysis. PID-8792-01 i. (Optional): Cap all tubes and place sam- ples and reagents back into the freezer. 2 Quick Start Guide (continued) for Using the Logix SmartTM SARS-CoV-2 Direct Saliva RUO Product (COVDS-R-003 and -004) 3 Start the Run a. In the Co-Dx Box software, click New. d. Click Information and in the Notes field, type any needed information. b. Select an assay template and click OK. e. Select the appropriate thermocycler and from the drop-down select Start Run. Perform in Co-Dx Box Software Perform in Co-Dx Box Software c. Under Run Setup, select Samples and type sample information in the appropriate order. f. Verify the tube clamp is in place and the appropriate reaction volume is listed, and select Start. PID-8792-01 The run initializes and a progress bar gives an estimated time to completion. 3Adobe PDF Library 16.0.7 Adobe InDesign 17.3 (Windows)