Generac SG300 12.9L Industrial Generator Set - Specifications and Features

Generac SG300 12.9L Industrial Generator Set

EPA Certified Stationary Emergency

Power Ratings

Standby Power Rating: 300 kW / 375 kVA @ 60 Hz

Prime Power Rating*: 270 kW / 338 kVA @ 60 Hz

*EPA Certified Prime ratings are not available in the U.S. or its Territories.

Image used for illustration purposes only.

Codes and Standards

Generac products are designed to the following standards:

  • UL2200, UL508, UL142, UL498
  • NFPA70, 99, 110, 37
  • NEC700, 701, 702, 708
  • ISO9001, 8528, 3046, 7637, Pluses #2b, 4
  • NEMA ICS10, MG1, 250, ICS6, AB1
  • ANSI C62.41
  • IBC 2009, CBC 2010, IBC 2012, ASCE 7-05, ASCE 7-10, ICC-ES AC-156 (2012)

Powering Ahead

For over 50 years, Generac has led the industry with innovative design and superior manufacturing. Generac ensures superior quality by designing and manufacturing most of its generator components, including alternators, enclosures and base tanks, control systems and communications software. Generac's gensets utilize a wide variety of options, configurations and arrangements, allowing us to meet the standby power needs of practically every application. Generac searched globally to ensure the most reliable engines power our generators. We choose only engines that have already been proven in heavy-duty industrial application under adverse conditions. Generac is committed to ensuring our customers' service support continues after their generator purchase.

Standard Features

Engine System

  • General: Oil Drain Extension, Air Cleaner, Fan Guard, Stainless Steel flexible exhaust connection, Critical Exhaust Silencer, Factory Filled Oil, Radiator duct adapter (open set only).
  • Fuel System: Primary and Secondary Fuel Shutoff, Flexible Fuel Line - NPT Connection.
  • Cooling System: Closed Coolant Recovery System, UV/Ozone resistant hoses, Factory-installed Radiator, Radiator drain extension, 50/50 Ethylene glycol antifreeze.
  • Engine Electrical System: Battery charging alternator, Battery Cables, Battery Tray, Solenoid activated starter motor, Rubber-booted engine electrical connections.

Alternator System

  • UL2200 GENprotect™
  • Class H insulation material
  • 2/3 Pitch
  • Skewed Stator
  • Permanent Magnet Excitation
  • Sealed Bearings
  • Amortisseur winding
  • Full load capacity alternator

Generator Set

  • Internal Genset Vibration Isolation
  • Separation of circuits - high/low voltage
  • Separation of circuits - multiple breakers
  • Wrapped Exhaust Piping
  • Standard Factory Testing
  • 2 Year Limited Warranty (Standby rated Units)
  • 1 Year Warranty (Prime rated units)
  • Silencer mounted in the discharge hood (enclosed only)

Enclosure (if selected)

  • Rust-proof fasteners with nylon washers to protect finish
  • High performance sound-absorbing material
  • Gasketed doors
  • Stamped air-intake louvers
  • Air discharge hoods for radiator-upward pointing
  • Stainless steel lift off door hinges
  • Stainless steel lockable handles
  • Rhino Coat™ - Textured polyester powder coat

Control System

  • Control Panel: Digital H Control Panel - Dual 4x20 Display, Programmable Crank Limiter, 7-Day Programmable Exerciser, Special Applications Programmable PLC, RS-232/485, All-Phase Sensing DVR, Full System Status, Utility Monitoring, Low Fuel Pressure Indication, 2-Wire Start Compatible.
  • Parameters Monitored: Power Output (kW), Power Factor, kW Hours, Total & Last Run, Real/Reactive/Apparent Power, All Phase AC Voltage, All Phase Currents, Oil Pressure, Coolant Temperature, Coolant Level, Engine Speed, Battery Voltage, Frequency.
  • Fault History: Date/Time Fault History (Event Log).
  • Governor Control: Isochronous Governor Control.
  • Connectivity: Waterproof/sealed Connectors.
  • Alarms & Shutdowns: Audible Alarms and Shutdowns, Not in Auto (Flashing Light), Auto/Off/Manual Switch, E-Stop (Red Mushroom-Type).
  • Compliance: NFPA110 Level I and II (Programmable).
  • Customization: Customizable Alarms, Warnings, and Events.
  • Communication: Modbus protocol.
  • Maintenance: Predictive Maintenance algorithm.
  • Security: Sealed Boards, Password parameter adjustment protection.
  • Data Logging: Single point ground, 15 channel data logging, 0.2 msec high speed data logging.
  • Display: Alarm information automatically comes up on the display.
  • Specific Alarms: Oil Pressure (Pre-programmable Low Pressure Shutdown), Coolant Temperature (Pre-programmed High Temp Shutdown), Coolant Level (Pre-programmed Low Level Shutdown), Low Fuel Pressure Alarm, Engine Speed (Pre-programmed Over speed Shutdown), Battery Voltage Warning.
  • Alarm Logging: Alarms & warnings time and date stamped, Alarms & warnings for transient and steady state conditions, Snap shots of key operation parameters during alarms & warnings, Alarms and warnings spelled out (no alarm codes).

Configurable Options

Engine System

  • General: Engine Block Heater, Oil Heater, Air Filter Restriction Indicator, Stone Guard (Open Set Only).
  • Engine Electrical System: 10A UL battery charger, Battery Warmer.

Alternator System

  • Alternator Upsizing
  • Anti-Condensation Heater
  • Tropical coating

Generator Set

  • Gen-Link Communications Software (English Only)
  • Extended Factory Testing (3 Phase Only)
  • IBC Seismic Certification
  • 8 Position Load Center
  • 2 Year Extended Warranty
  • 5 Year Warranty
  • 5 Year Extended Warranty

Circuit Breaker Options

  • Main Line Circuit Breaker
  • 2nd Main Line Circuit Breaker
  • Shunt Trip and Auxiliary Contact
  • Electronic Trip Breakers

Enclosure

  • Standard Enclosure
  • Level 1 Sound Attenuation
  • Level 2 Sound Attenuation
  • Steel Enclosure
  • Aluminum Enclosure
  • 150 MPH Wind Kit
  • 12 VDC Enclosure Lighting Kit
  • 120 VAC Enclosure Lighting Kit
  • AC/DC Enclosure Lighting Kit
  • Door Alarm Switch

Control System

  • 21-Light Remote Annunciator
  • Remote Relay Panel (8 or 16)
  • Oil Temperature Sender with Indication Alarm
  • Remote E-Stop (Break Glass-Type, Surface Mount)
  • Remote E-Stop (Red Mushroom-Type, Surface Mount)
  • Remote E-Stop (Red Mushroom-Type, Flush Mount)
  • Remote Communication - Modem
  • Remote Communication - Ethernet
  • 10A Run Relay
  • Ground fault indication and protection functions

Engineered Options

Engine System

  • Coolant heater ball valves
  • Fluid containment pans

Alternator System

  • 3rd Breaker Systems

Generator Set

  • Special Testing

Enclosure

  • Motorized Dampers
  • Enclosure Ambient Heaters

Control System

  • Spare inputs (x4) / outputs (x4) - H Panel Only
  • Battery Disconnect Switch

Rating Definitions

Standby: Applicable for a varying emergency load for the duration of a utility power outage with no overload capability.

Prime: Applicable for supplying power to a varying load in lieu of utility for an unlimited amount of running time. A 10% overload capacity is available for 1 out of every 12 hours. The Prime Power option is only available on International applications.

Power ratings in accordance with ISO 8528-1, Second Edition dated 2005-06-01, definitions for Prime Power (PRP) and Emergency Standby Power (ESP).

Engine Specifications

CategorySpecificationDetails
GeneralMakeGenerac
Cylinder #6
TypeIn-line
Displacement - L (Cu In)12.88 (785.99)
Bore - mm (in)135 (5.31)
Stroke - mm (in)150 (5.91)
Compression Ratio10.1:1
Intake Air MethodTurbocharged/Aftercooled
Number of Main Bearings7
Connecting RodsCarbon Steel
Cylinder HeadCast Iron GT250, OHV
Cylinder LinersDuctile Iron
IgnitionAltronic CD1
PistonsAluminum
CrankshaftDuctile Iron
Lifter TypeSolid
Intake Valve MaterialSpecial Heat-Resistant Steel
Exhaust Valve MaterialAlloy Steel, High Temp
Hardened Valve SeatsAlloy Steel, High Temp
Engine GoverningGovernorElectronic
Frequency Regulation (Steady State)+/- 0.25%
CategorySpecificationDetails
Lubrication SystemOil Pump TypeGear
Oil Filter TypeFull-flow Cartridge
Crankcase Capacity - L (qts)34.3 (36.2)
Cooling SystemCooling System TypePressurized Closed Recovery
Water Pump Flow - gpm (lpm)94 (356)
Fan TypePusher
Fan Speed (rpm)2250
Fan Diameter mm (in)863 (34)
Coolant Heater Wattage2000
Coolant Heater Standard Voltage240 V
Fuel SystemFuel TypeNatural Gas
CarburetorDown Draft
Secondary Fuel RegulatorStandard
Fuel Shut Off SolenoidStandard (Dual)
Operating Fuel Pressure11" - 15" H₂O
Engine Electrical SystemSystem Voltage24 VDC
Battery Charging AlternatorStandard
Battery SizeSee Battery Index 0161970SBY
Battery Voltage(2) 12 VDC
Ground PolarityNegative

Alternator Specifications

SpecificationDetails
Standard Model520
Poles4
Field TypeRevolving
Insulation Class - RotorH
Insulation Class - StatorH
Total Harmonic Distortion<5%
Telephone Interference Factor (TIF)< 50
Standard ExcitationPermanent Magnet
BearingsSealed Ball
CouplingDirect, Flexible Disc
Prototype Short Circuit TestYes
Voltage Regulator TypeFull Digital
Number of Sensed Phases3
Regulation Accuracy (Steady State)+/- 0.25%

Operating Data

Power Ratings (Natural Gas)

VoltagekWAmps
Three-Phase 120/208 VAC @0.8pf300 kW1041
Three-Phase 120/240 VAC @0.8pf300 kW902
Three-Phase 277/480 VAC @0.8pf300 kW451
Three-Phase 346/600 VAC @0.8pf300 kW361

Starting Capabilities (sKVA) vs. Voltage Dip

Alternator480 VAC208/240 VAC
kW10%15%20%25%30%35%10%15%20%25%30%35%
Standard3003034546057579081059227341454568681794

Fuel Consumption Rates (Natural Gas)

Percent LoadStandby (ft³/hr)
25%1968 (55)
50%2857 (81)
75%3625 (102)
100%4621 (130)

*Fuel supply installation must accommodate fuel consumption rates at 100% load.

Cooling

ParameterStandby
Air Flow (inlet air combustion and radiator) (ft³/min)19,668 (556.8)
Coolant Flow per Minute (gpm)94 (356)
Coolant System Capacity (gal)19 (71.9)
Heat Rejection to Coolant (BTU/hr)945,844
Max. Operating Air Temp on Radiator (°F (°C))122 (50)
Maximum Radiator Backpressure (in H₂O)0.5

Combustion Air Requirements

ParameterStandby
Flow at Rated Power (cfm)603 (17)

Engine

ParameterStandby
Rated Engine Speed (rpm)2150
Engine Horsepower** (hp)477
Piston Speed (ft/min)2116 (645)
BMEP (psi)269

** Refer to "Emissions Data Sheet" for maximum bHP for EPA and SCAQMD permitting purposes.

Exhaust

ParameterStandby
Exhaust Flow (Rated Output) (cfm)2076 (59)
Maximum Recommended Back Pressure (inHg)1.5
Exhaust Temp (Rated Output) (°F (°C))1450 (788)
Exhaust Outlet Size (Open Set) (in)3.5" I.D. Flex (No Muffler)

Deration - Operational characteristics consider maximum ambient conditions. Derate factors may apply under atypical site conditions. Please consult a Generac Power Systems Industrial Dealer for additional details. All performance ratings in accordance with ISO3046, BS5514, ISO8528 and DIN6271 standards.

Dimensions, Weights, and Sound Levels

Open Set (Includes Exhaust Flex)

Dimensions (L x W x H): 138.74 in (3524.1 mm) x 57.6 in (1463.1 mm) x 68.04 in (1728.3 mm)

Weight: 6612 lbs (2998 kg)

Sound Level: 90 dBA*

Standard Enclosure

Dimensions (L x W x H): 174.7 in (4437.4 mm) x 52.98 in (1345.7 mm) x 77.8 in (1976.1 mm)

Weight: Steel: 7786 lbs (3531 kg) / Aluminum: 7013 lbs (3180 kg)

Sound Level: 88 dBA*

Level 1 Acoustic Enclosure

Dimensions (L x W x H): 200.19 in (5084.7 mm) x 57.49 in (1460.4 mm) x 77.80 in (1976.1 mm)

Weight: Steel: 8342 lbs (3783 kg) / Aluminum: 7203 lbs (3266 kg)

Sound Level: 81 dBA*

Level 2 Acoustic Enclosure

Dimensions (L x W x H): 180.65 in (4588.4 mm) x 57.49 in (1460.4 mm) x 107.3 in (2725.4 mm)

Weight: Steel: 8904 lbs (4038 kg) / Aluminum: 7404 lbs (3357 kg)

Sound Level: 76 dBA*

*All measurements are approximate and for estimation purposes only. Sound levels measured at 23 ft (7 m) and does not account for ambient site conditions.

Contact Information

For detailed installation drawings or further information, please consult your factory-recognized Generac Industrial Dealer.

Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com

©2013 Generac Power Systems, Inc. All rights reserved.

PDF preview unavailable. Download the PDF instead.

0k4299-b-sg300-12-9l-60hz-1 ? Adobe InDesign CS6 (Windows) Adobe PDF Library 10.0.1

Related Documents

Preview Generac SG150 Industrial Spark-Ignited Generator Set - 150 kW Specifications
Detailed specifications, features, options, dimensions, and operating data for the Generac SG150 Industrial Spark-Ignited Generator Set, rated at 150 kW.
Preview Generac Guardian Series 16/20/22 kW Residential Standby Generators
Explore the Generac Guardian Series residential standby generators, featuring 16, 20, and 22 kW power output. These generators offer advanced G-Force engine technology, True Power™ electrical technology for clean power, and Mobile Link™ Wi-Fi remote monitoring for reliable home backup. Learn about their features, specifications, transfer switch options, and available accessories.
Preview Generac Guardian Series 8-13 kVA Automatic Standby Generators | Home Backup Power
Explore the Generac Guardian Series 8-13 kVA automatic standby generators, offering reliable home backup power with advanced features like the Nexus™ Controller and OHVI® engine. Learn about specifications and benefits for power outage protection.
Preview Generac 20 kW Guardian Series Standby Generator: Features, Specifications, and Accessories
Detailed overview of the Generac 20 kW Guardian Series Standby Generator, covering its key features, technical specifications, engine and generator details, installation system, remote monitoring capabilities, and available accessories for residential and commercial use.
Preview Generac Guardian Series 20/22/24 kW Standby Generators | Home Backup Power
Explore the Generac Guardian Series 20/22/24 kW residential standby generators. Featuring G-Force engines, True Power™ technology, and Mobile Link™ connectivity for reliable home backup power.
Preview Generac SD300 Industrial Diesel Generator Set: 300 kW Specifications
Detailed specifications for the Generac SD300 Industrial Diesel Generator Set, featuring a 300 kW output, EPA certification for stationary emergency use, and comprehensive technical data.
Preview Generac 100 Amp Automatic Transfer Switch/Load Center Installation Guide with Express Install Kit
Comprehensive installation guide for Generac 100 Amp Automatic Transfer Switch/Load Center models, including the Express Install Kit. Learn how to safely install and connect your standby generator system, covering site preparation, wiring, and final connections.
Preview Generac 60 Hz Air-Cooled Generators Owner's Manual (10 kW - 26 kW)
This comprehensive owner's manual from Generac provides essential guidance for the safe operation, maintenance, and troubleshooting of 60 Hz air-cooled standby generators, covering models from 10 kW to 26 kW.