30W Reliable Railway DC-DC Converter

RSD-30 series
User's Manual

UL62368-1 AS/NZS62368-1 TPTC004 IEC62368-1

 Features

 Applications

Compliance to BS EN/EN50155 and BS EN/EN45545-2 railway standard

Bus,tram,metro or railway system Wireless network

Ultra compact and 1U low profile(25mm)

Telecom or datacom system

4:1 wide input range

Highly vibrating, highly dusty, extremely

No minimum load required

low or high temperature harsh environment

Protections: Short circuit / Overload / Over voltage /

Input reverse polarity

4000VDC I/O isolation (reinforced isolation) Half encapsulated , cooling by free air convection

 GTIN CODE

-40~+70 wide working temperature

MW Search: https://www.meanwell.com/serviceGTIN.aspx

Built-in constant current limiting circuit

LED indicator for power on

3 years warranty

 Description

RSD-30 is a 30W enclosed type DC-DC reliable railway converter. This series is compliant with BS EN/EN50155/

IEC60571 railway standard, constituting three types of models with 4:1 wide but different input ranges

9~36V/18~72V/40~160V, suitable for railway and all kinds of transportation systems exploiting the frequently

used standard input voltages such as 12V, 24V, 36V, 48V, 72V, 96V and 110V. Various output voltages,

3.3V, 5V, 12V and 24V are available for selection. This series has the capability of working under -40~+70, low ripple and noise, supreme EMC characteristics,

4KVDC I/P-OP, low enclosure profile 25mm and an interior with semi-potted silicone. It does not only well

fits the in-car systems or the facilities by rails for railway, trams and buses but also can be used in the harsh

environment with high vibration, high dust, extremely low or high temperature, etc.

 Model Encoding RSD - 30 G - 5

Downloaded from Arrow.com.

Output voltage (3.3/5/12/24Vdc) Input voltage (G: 9~36Vdc, L: 18~72Vdc, H: 40~160Vdc) Rated wattage Series name

File Name:RSD-30-SPEC 2024-02-23

30W Reliable Railway DC-DC Converter

RSD-30 series

SPECIFICATION

MODEL

RSD-30G-3.3 RSD-30G-5 RSD-30G-12 RSD-30G-24 RSD-30L-3.3 RSD-30L-5 RSD-30L-12 RSD-30L-24

OUTPUT INPUT

DC VOLTAGE

3.3V

5V

12V

24V

3.3V

5V

12V

24V

RATED CURRENT

6A

6A

2.5A

1.25A

6A

6A

2.5A

1.25A

CURRENT RANGE

0 ~ 6A

0 ~ 6A

0 ~ 2.5A

0 ~ 1.25A 0 ~ 6A

0 ~ 6A

0 ~ 2.5A

0 ~ 1.25A

RATED POWER

19.8W

30W

30W

30W

19.8W

30W

30W

30W

RIPPLE & NOISE (max.) Note.2 70mVp-p

70mVp-p

60mVp-p

50mVp-p

70mVp-p

70mVp-p

60mVp-p

50mVp-p

VOLTAGE TOLERANCE Note.3 ±2.0%

±2.0%

±2.0%

±2.0%

±2.0%

±2.0%

±2.0%

±2.0%

LINE REGULATION

±0.5%

±0.5%

±0.3%

±0.2%

±0.5%

±0.5%

±0.3%

±0.2%

LOAD REGULATION

±0.5%

±0.5%

±0.3%

±0.2%

±0.5%

±0.5%

±0.3%

±0.2%

SETUP, RISE TIME

120ms, 85ms at full load

HOLD UP TIME (Typ.)

Please refer to page 5 Hold up Time( Load de-rating curve )

VOLTAGE RANGE CONTINUOUS 9 ~ 36VDC

18 ~ 72VDC

EFFICIENCY (Typ.)

84%

84%

86.5%

89%

84%

86%

90%

91%

DC CURRENT (Typ.)

1.1A/24V 1.5A/24V

0.52A/48V 0.8A/48V

INRUSH CURRENT (Typ.) 20A/24VDC

20A/48VDC

EN50155:2007-G type comply with S1 level(3ms) @full load,S2 level(10ms) @80% load; L type comply with S2 level(10ms) @full load
INTERRUPTION OF VOLTAGE SUPPLY EN50155:2017-Comply with S1 level

OVERLOAD PROTECTION
OVER VOLTAGE
WORKING TEMP. WORKING HUMIDITY STORAGE TEMP. ENVIRONMENT TEMP. COEFFICIENT VIBRATION OPERATING ALTITUDE SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE

105 ~ 135% rated output power

Protection type : Constant current limiting, recovers automatically after fault condition is removed

3.8 ~ 4.5V 5.75 ~ 7V

13.8 ~ 16.2V 27.6 ~ 32.4V 3.8 ~ 4.5V 5.75 ~ 7V

13.8 ~ 16.2V 27.6 ~ 32.4V

Protection type : Shut down o/p voltage, re-power on to recover -40 ~ +55 (no derating) ; +70 @ 60% load by free air convection ; +70 (no derating with external base plate)

5 ~ 95% RH non-condensing

-40 ~ +85

±0.03%/ (0 ~ 50)

10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes ; Mounting : compliance to IEC61373

5000 meters

IEC 62368-1, UL 62368-1, AS/NZS 62368-1, EAC TP TC 004 approved, Design refer to BS EN/EN62368-1

I/P-O/P:4KVDC I/P-FG:2.5KVDC O/P-FG:2.5KVDC

I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH

Parameter

Standard

Test Level / Note

Conducted

BS EN/EN55032

Class A

EMC EMISSION SAFETY & EMC
(Note 4)
EMC IMMUNITY

Radiated Harmonic Current Voltage Flicker BS EN/EN55035 Parameter ESD Radiated Field EFT / Burst Surge Conducted

BS EN/EN55032 BS EN/EN61000-3-2 BS EN/EN61000-3-3
Standard BS EN/EN61000-4-2 BS EN/EN61000-4-3 BS EN/EN61000-4-4 BS EN/EN61000-4-5 BS EN/EN61000-4-6

Class B ---------
Test Level / Note Level 3, ±8KV air ; Level 3, ±6KV contact Level X, 20V/m Level 3, 2KV at power Level 3,1KV Line-Line, Level 3, 2KV Line-Earth Level 3

OTHERS

RAILWAY STANDARD MTBF DIMENSION PACKING

Compliance to BS EN/EN45545-2 for fire protection ;BS EN/EN50155 / IEC60571 including IEC61373 for shock & vibration, BS EN/EN50121-3-2 for EMC 3093.5K hrs min. Telcordia SR-332 (Bellcore) ; 396.9K hrs min. MIL-HDBK-217F (25) 113*60*25mm (L*W*H) 0.25Kg; 56pcs/15Kg/0.81CUFT

NOTE

1. All parameters NOT specially mentioned are measured at 24,48VDC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1F & 47F parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf ) 5. Strongly recommended that external output capacitance should not exceed 5000uF. 6. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft).  Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Downloaded from Arrow.com.

File Name:RSD-30-SPEC 2024-02-23

30W Reliable Railway DC-DC Converter

RSD-30 series

SPECIFICATION

MODEL

RSD-30H-3.3

RSD-30H-5

RSD-30H-12

RSD-30H-24

DC VOLTAGE

3.3V

5V

12V

24V

RATED CURRENT CURRENT RANGE RATED POWER

6A 0 ~ 6A 19.8W

6A 0 ~ 6A 30W

2.5A 0 ~ 2.5A 30W

1.25A 0 ~ 1.25A 30W

OUTPUT

RIPPLE & NOISE (max.) Note.2 70mVp-p

VOLTAGE TOLERANCE Note.3 ±2.0%

LINE REGULATION

±0.5%

LOAD REGULATION

±0.5%

70mVp-p ±2.0% ±0.5% ±0.5%

60mVp-p ±2.0% ±0.3% ±0.3%

50mVp-p ±2.0% ±0.2% ±0.2%

SETUP, RISE TIME

120ms, 85ms at full load

HOLD UP TIME (Typ.)

Please refer to page 5 Hold up Time( Load de-rating curve )

VOLTAGE RANGE CONTINUOUS 40 ~ 160VDC

EFFICIENCY (Typ.)

87%

87%

89%

89%

INPUT

DC CURRENT (Typ.)

0.23A/110V

0.35A/110V

INRUSH CURRENT (Typ.) 20A/110VDC

EN50155:2007-H-type comply with S2 level(10ms) @ full load INTERRUPTION OF VOLTAGE SUPPLY
EN50155:2017-Comply with S1 level

OVERLOAD PROTECTION
OVER VOLTAGE
WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP. TEMP. COEFFICIENT VIBRATION OPERATING ALTITUDE

105 ~ 135% rated output power

Protection type : Constant current limiting, recovers automatically after fault condition is removed

3.8 ~ 4.5V

5.75 ~ 7V

13.8 ~ 16.2V

27.6 ~ 32.4V

Protection type : Shut down o/p voltage, re-power on to recover -40 ~ +55 (no derating) ; +70 @ 60% load by free air convection ; +70 (no derating with external base plate)

5 ~ 95% RH non-condensing

-40 ~ +85

±0.03%/ (0 ~ 50)

10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes ; Mounting : compliance to IEC61373

5000 meters

SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE
EMC EMISSION
SAFETY & EMC
(Note 4)
EMC IMMUNITY

IEC 62368-1, UL 62368-1, AS/NZS 62368-1, EAC TP TC 004 approved, Design refer to BS EN/EN62368-1

I/P-O/P:4KVDC I/P-FG:2.5KVDC O/P-FG:2.5KVDC

I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH

Parameter

Standard

Test Level / Note

Conducted

BS EN/EN55032

Class A

Radiated

BS EN/EN55032

Class B

Harmonic Current

BS EN/EN61000-3-2

-----

Voltage Flicker

BS EN/EN61000-3-3

-----

BS EN/EN55035

Parameter

Standard

Test Level / Note

ESD

BS EN/EN61000-4-2

Level 3, ±8KV air ; Level 3, ±6KV contact

Radiated Field

BS EN/EN61000-4-3

Level X, 20V/m

EFT / Burst

BS EN/EN61000-4-4

Level 3, 2KV at power

Surge

BS EN/EN61000-4-5

Level 3,1KV Line-Line, Level 3, 2KV Line-Earth

Conducted

BS EN/EN61000-4-6

Level 3

OTHERS

RAILWAY STANDARD MTBF DIMENSION PACKING

Compliance to BS EN/EN45545-2 for fire protection;BS EN/EN50155 /IEC60571 including IEC61373 for shock & vibration,BS EN/EN50121-3-2 for EMC 3093.5K hrs min. Telcordia SR-332 (Bellcore) ; 396.9K hrs min. MIL-HDBK-217F (25) 113*60*25mm (L*W*H) 0.25Kg; 56pcs/15Kg/0.81CUFT

NOTE

1. All parameters NOT specially mentioned are measured at 110VDC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1F & 47F parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf ) 5. Strongly recommended that external output capacitance should not exceed 5000uF. 6. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft).  Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Downloaded from Arrow.com.

File Name:RSD-30-SPEC 2024-02-23

30W Reliable Railway DC-DC Converter

RSD-30 series

Block Diagram

EMI

I/P

FILTER

FG

RECTIFIERS &
FILTER

POWER SWITCHING

O.L.P.

PWM CONTROL

RECTIFIERS &
FILTER

O.V.P.

DETECTION CIRCUIT

fosc : 110KHz
+V -V

Input Fuse
There is one fuse connected in series to the positive input line, which is used to protect against abnormal surge. Fuse specifications of each model are shown as below.

Type

Fuse Type

G

Time-Lag

L

Time-Lag

H

Time-Lag

Reference and Rating CONQUE MST, 6.3A, 250V CONQUE MST, 3.15A, 250V CONQUE MST, 2A, 250V

Input Reverse Polarity Protection
There is a MOSFET connected in series to the negative input line. If the input polarity is connected reversely, the MOSFET opens and there will be no output to protect the unit.

Input Range and Transient Ability
The series has a wide range input capability. With ±40% of rated input voltage, it can withstand that for 1 second.

Input Under-Voltage Protection
If input voltage drops below Vimin, the internal control IC shuts down and there is no output voltage. It recovers automatically when input voltage reaches above Vimin, please refer to the cruve below.

RSD-30G-24

Vo 30
25

20

15

Turn On

Turn Off 10

5

6.3

8.3

0

Vin

6

8

10

12

14

16

RSD-30L-24

Vo 30
25

20

15

Turn On

Turn Off 10

5

12.3

16.3

0

Vin

12

16

20

24

28

32

RSD-30H-24

Vo 30
25

20

15

Turn On

Turn Off 10

5

25.5

37

0

Vin

24

32

40

48

56

Inrush Current
Inrush current is suppressed by a resistor during the initial start-up, and then the resistor is bypassed by a MOSFET to reduce power consumption after accomplishing the start-up.

Downloaded from Arrow.com.

File Name:RSD-30-SPEC 2024-02-23

LOAD

30W Reliable Railway DC-DC Converter

RSD-30 series

Hold-up Time
EN50155: 2007 version - H type is in compliance with S2 level (10ms), while G and L types are in compliance with S1 level (3ms) at full load output condition. To fulfil the requirements of S2 level (10ms), G types require de-rating their output load to 80%, please refer to the curve diagrams below.

RSD-30G-3.3

100% 90% 80% 70% 60% 50% 40% 30% 20% 10%
0% 0ms

10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms

TIME

LOAD

RSD-30G-5
100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0%
0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms
TIME

RSD-30G-12
100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0%
0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms
TIME

LOAD

RSD-30G-24
100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0%
0ms 10ms 20ms 30ms 40ms 50ms 60m s 70ms 80ms 90ms
TIME

EN50155: 2017 version - Comply with S1 level (3ms)

Output Voltage Adjustment
This function is optional, which the standard product does not have it. If you do need the function, please contact MW for details.

LOAD

Downloaded from Arrow.com.

File Name:RSD-30-SPEC 2024-02-23

30W Reliable Railway DC-DC Converter

RSD-30 series

Efficiency vs Load & Vin Curve

The efficiency vs load & Vin curves of each model are shown as below.

RSD-30G-3.3

RSD-30G-5

EFFICIENCY

96% 92% 88% 84% 80% 76% 72% 68% 64%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

24Vdc 36Vdc 9Vdc

EFFICIENCY

96% 92% 88% 84% 80% 76% 72% 68% 64%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

LOAD

LOAD

EFFICIENCY

RSD-30G-24
96% 92% 88% 84% 80% 76% 72% 68% 64%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD

24Vdc 36Vdc 9Vdc

EFFICIENCY

RSD-30L-3.3
95% 91% 87% 83% 79% 75% 71% 67% 63% 59% 55%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD

EFFICIENCY

RSD-30L-12
96% 92% 88% 84% 80% 76% 72% 68% 64%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD

48Vdc 72Vdc 18Vdc

EFFICIENCY

RSD-30L-24
96% 92% 88% 84% 80% 76% 72% 68% 64%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD

EFFICIENCY

RSD-30H-5
95% 91% 87% 83% 79% 75% 71% 67% 63% 59% 55% 51%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD

110Vdc 160Vdc 40Vdc

EFFICIENCY

RSD-30H-12
93% 89% 85% 81% 77% 73% 69% 65% 61%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD

24Vdc 36Vdc 9Vdc
48Vdc 72Vdc 18Vdc
48Vdc 72Vdc 18Vdc
110Vdc 160Vdc 40Vdc

EFFICIENCY

EFFICIENCY

EFFICIENCY

EFFICIENCY

RSD-30G-12
96% 92% 88% 84% 80% 76% 72% 68% 64%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
RSD-30L-5
96% 92% 88% 84% 80% 76% 72% 68% 64%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
RSD-30H-3.3
95% 91% 87% 83% 79% 75% 71% 67% 63% 59% 55% 51%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
RSD-30H-24
94% 90% 86% 82% 78% 74% 70% 66% 62% 58%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD

24Vdc 36Vdc 9Vdc
48Vdc 72Vdc 18Vdc
110Vdc 160Vdc 40Vdc
110Vdc 160Vdc 40Vdc

Parallel and Series Connection
A.Operation in Parallel Since RSD-30 series don't have built-in parallel circuit, it can only use external circuits to achieve the redundant operation but not increase the current rating.
1.Add a diode at the positive-output of each power supply (as shown as below), the current rating of the diode should be larger than the maximum output current rating and attached to a suitable heat sink. This is only for redundant use (increase the reliability of the system) and users have to check suitability of the circuit by themselves.

I/P

+

EIN

PS1

D1

RL

I/P

-

I/P

+

PS2

D2

I/P

-

2.When using S.P.S. in parallel connection, the leakage current will increase at the same time. This could pose as a shock hazard for the user. So please contact the supplier if you have this kind of application.
B.Operation in Series RSD-30 can be operated in series. Here are the methods of doing it: 1.Positive and negative terminals are connected as shown as below. According to the connection, you can get the positive and negative output voltages for your loads.

I/P

+

E IN

PS1

I/P

-

I/P

+

PS2

I/P

-

+V RL
COM
RL -V

File Name:RSD-30-SPEC 2024-02-23

Downloaded from Arrow.com.

30W Reliable Railway DC-DC Converter

RSD-30 series

2.Increase the output voltage (current does not change). Because RSD-30 series have no reverse blocking diode in the unit, you should add an external blocking diode to prevent the damage of every unit while starting up. The voltage rating of the external diode should be larger than V1+V2 (as shown as below).

I/P

+

+V

E IN

PS1 V1 D1

I/P

-

I/P PS2
I/P

+ V2
-

V1+V2 RL
D2 -V

Overload Protection
If the output draw up to 105~135% of its output power rating, the converter will go into overload protection which is constant current mode. After the faulty condition is removed, it will recover automatically. Please refer to the diagram below for the detail operation characteristic. Please note that it's not suitable to operate within the overload region continuously, or it may cause to over temperature and reduce the life of the power supply unit or even damage it.
Vo(%)
100

Overload

50

region

Io(%)

0

50

100

150

Over Voltage Protection
The converter shuts off to protect itself when the output voltage drawn exceeds 115~140% of its output rating. It must be repowered on to recover.
LED Indicator
Equipped with a built-in LED indicator, the converter provides an easy way for users to check its condition through the LED indicator. Green : normal operation; No signal: no power or failure.
Derating Curve
a.Single unit operation If the unit has no iron plate mounted on its bottom, the maximum ambient temperature for the unit will be 55 as operating under full load condition. It requires de-rating output current when ambient temperature is between 55~70, please refer to the de-rating curve as below.

100

100

80

80

60

60

G:Vin  24V

40

L:Vin  48V

40

H:Vin  110V

20

20

-40 -35

0

10

20

30

40

50 55 60 70 (HORIZONTAL) -30

AMBIENT TEMPERATURE ()

0 10 20 30 40 50 60 70 75 80 (HORIZONTAL)
Tcase ()

LOAD (%) RATED CURRENT (%)

Downloaded from Arrow.com.

File Name:RSD-30-SPEC 2024-02-23

30W Reliable Railway DC-DC Converter

RSD-30 series

Suitable installation methods are shown as below. Since RSD-30 is a semi-potted model, its thermal performances for the following installation methods are similar and share the same derating curve.

b.Operate with additional iron plate If it is necessary to fulfil the requirements of EN50155 TX level that operate the unit fully-loaded at 70, RSD-30 series must be installed onto an iron plate on the bottom. The size of the suggested iron plate is shown as below. In order for optimal thermal performance, the iron plate must have an even & smooth surface and RSD-30 series must be firmly mounted at the center of the iron plate.
Unit:mm
M3*4
360

LOAD (%)
2

360

The load vs ambient temperature curve is shown as below.

100 80 60 40 20

-40

0

10

20

30

40

50

60 70 (HORIZONTAL)

AMBIENT TEMPERATURE ()
Suitable installation methods are shown as below. Since RSD-30 is a semi-potted model, its thermal performances for the following installation methods are similar and share the same derating curve.

iron plate Downloaded from Arrow.com.

File Name:RSD-30-SPEC 2024-02-23

30W Reliable Railway DC-DC Converter

RSD-30 series

Immunity to Environmental Conditions

Test method Cooling Test Dry Heat Test Damp Heat Test, Cyclic Vibration Test Increased Vibration Test Shock Test

Standard EN 50155 section 12.2.3 (Column 2, Class TX) EN 60068-2-1 EN 50155 section 12.2.4 (Column 2, Class TX) EN 50155 section 12.2.4 (Column 3, Class TX & Column 4, Class TX) EN 60068-2-2
EN 50155 section 12.2.5 EN 60068-2-30
EN 50155 section 12.2.11 EN 61373
EN 50155 section 12.2.11 EN 61373
EN 50155 section 12.2.11 EN 61373

Test conditions
Temperature: -40 Dwell Time: 2 hrs/cycle
Temperature: 70 / 85 Duration: 6 hrs / 10min
Temperature: 25~55 Humidity: 90%~100% RH Duration: 48 hrs
Temperature: 19 Humidity: 65% Duration: 10 mins
Temperature: 19 Humidity: 65% Duration: 5 hrs
Temperature: 21± 3 Humidity: 65 ± 5% Duration: 30ms*18

Low Temperature Storage Test

EN 50155 section 12.2.3 (Column 2, Class TX) EN 60068-2-1

Temperature: -40 Dwell Time: 16 hrs

Salt Mist Test

EN 50155 section 12.2.10 (Class ST4)

Temperature: 35±2 Duration: 96 hrs

Status No damage
PASS PASS PASS PASS PASS PASS PASS

EN45545-2 Fire Test Conditions

Test Items Items
R24 Oxygen index test
R25 Glow-wire test
R26 Vertical flame test

Standard
EN 45545-2:2013+A1:2015 EN ISO 4589-2:1996
EN 45545-2:2013+A1:2015 EN 60695-2-11:2000 EN 45545-2:2013+A1:2015 EN 60695-11:2003

HL1 PASS PASS PASS

Hazard Level HL2 PASS
PASS
PASS

HL3 PASS PASS PASS

Downloaded from Arrow.com.

File Name:RSD-30-SPEC 2024-02-23

30W Reliable Railway DC-DC Converter
Mechanical Specification
113 105

RSD-30 series
Case No.253A Unit:mm
4

4

9.5

9.5

LED

1

1

O/P

2

2

I/P

3

60

52

7.5

Top View

4-3.5

25

tc

7

46
tc : Max. Case Temperature Side View

Input Terminal Pin No. Assignment :

Pin No. 1 2 3

Assignment DC INPUT V+ DC INPUT VFG

Output Terminal Pin No. Assignment :

Pin No. 1 2

Assignment DC OUTPUT -V DC OUTPUT +V