First Alert CO5120BN / CO5120PDBN AC Powered Carbon Monoxide Alarm User's Manual

Models: CO5120BN (with Battery Back-Up), CO5120PDBN (with Battery Back-Up and Digital Display)

Important! Please Read Carefully and Save. This user's manual contains important information about your alarm's operation. If you are installing this alarm for use by others, you must leave this manual—or a copy of it—with the end user.

Printed in Mexico M08-0002-009 K1 5/16. Conforms to UL Std 2034.

© 2016 BRK Brands, Inc. All rights reserved. Distributed by BRK Brands, Inc. First Alert® is a registered trademark of The First Alert Trust.

Introduction

Thank you for choosing BRK Brands, Inc. for your Carbon Monoxide Alarm needs. You have purchased a state-of-the-art Carbon Monoxide Alarm designed to provide you with early warning of carbon monoxide. Key features include:

Basic Safety Information

FCC Compliance

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.

However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Warning: Changes or modifications to the product, not expressly approved by First Alert / BRK Brands, Inc., could void the user’s authority to operate the equipment.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

How Your CO Alarm Works

The Cover Of Your CO Alarm

  1. Test/Silence Button or Test/Silence/Scroll Button (CO5120PDBN only)
  2. POWER/ALARM Light (RED)
  3. Air Vents
  4. Alarm Horn: 85 dB audible alarm for test, alarm, and unit malfunction warning.
  5. Digital Display (CO5120PDBN only)

Understanding the Light and Horn Patterns

ConditionLED (Red Light)Horn
POWER UPOn continuously with AC; Flash a minute with batterySilent
DURING TESTINGLED flashes approximating the horn patternHorn Pattern: 4 beeps, pause, 4 beeps, pause
LOW OR MISSING BATTERYLow battery Latch PatternHorn "chirps" once per minute
WARNING: When the AC power is Off, if the battery is dead or missing, the CO Alarm cannot work.
ALARM CONDITION (Stand Alone Alarm)LED flashes approximating the horn patternHorn Pattern: 4 beeps, pause, 4 beeps, pause repeating
ALARM CONDITION (Interconnected Series of CO Alarms)LED flashes rapidly on the unit(s) that triggered the alarm. LEDs on the other Alarms in the series will not flashHorn Pattern: 4 beeps, pause, 4 beeps, pause repeating on all CO Alarms
ALARM SILENCELED flashes approximating the horn patternHorn stays quiet for 4 minutes
LOW BATTERY SILENCELED flashing approximately every minuteHorn is Silent for up to 8 hours
ALARM LATCHAudio Off and LED flashing 2 seconds on, 2 seconds off after local alarm unless reset by Test/Silence buttonHorn is Silent
LOW BATTERY LATCHLED flashing 4 seconds on, 2 seconds offHorn is Silent
NOTE: Latching features are not active during battery backup mode operation.
MALFUNCTIONLED flashes 3 times synchronized with 3 chirpsHorn sounds 3 chirps every minute
END OF LIFELED flashes 5 times synchronized with 5 chirpsHorn sounds 5 chirps every minute

Additional Features for Model CO5120PDBN with Digital Display

Using the Peak CO Memory

The CO Memory Feature lets you check the highest level of CO recorded during an alarm.

To check CO Memory:

  1. Press and release the Test/Silence/Scroll button until the dash scrolls to “MEMORY”.
  2. Press and hold Test/Silence/Scroll button to display Memory CO level.

To clear CO Memory:

  1. Automatically resets after 24 hours.
  2. Press and release the Test/Silence/Scroll button until the dash scrolls to “CLEAR MEMORY.”
  3. Press and hold the Test/Silence/Scroll button until the display shows “CLr.”
  4. Remove all power; unplug the Alarm and remove the battery.

NOTE: The highest CO level will be saved for 24 hours. DO NOT clear the CO Memory reading if you plan to call someone to investigate a CO problem! Clear the CO Memory reading only after the investigator has checked your home. If the investigator will not arrive within the 24-hour time period before the unit automatically resets, be sure to write down the peak level.

Smart Interconnect Feature

This CO Alarm includes “Smart Interconnect” which enables the Alarm to be interconnected with other BRK Smoke and CO Alarms. When interconnected to Smoke Alarms that go into alarm, this CO Alarm will sound the smoke horn pattern.

Installation

Where to Install CO Alarms

The National Fire Protection Association (NFPA) recommends that a CO Alarm should be centrally located outside of each separate sleeping area in the immediate vicinity of the bedrooms. For added protection, install additional CO Alarms in each separate bedroom, and on every level of your home. If your bedroom hallway is longer than 40 feet (12 meters), install a CO Alarm at BOTH ends of the hallway.

Suggested Areas for Installing Additional CO Alarms

[Diagram showing placement in a house layout: Living Room, Hall, Kitchen, Bedroom, Basement, Garage]

Required to Meet NFPA Recommendations

Where CO Alarms Should Not Be Installed

DO NOT locate this CO Alarm:

Before You Begin Installation

This unit is designed to be mounted on any standard wiring junction box up to a 4-inch (10 cm) size, on either the ceiling or wall. Read “Where to Install CO Alarms” and “Where Not To Install CO Alarms” before you begin.

This Alarm must have AC or battery power to operate. If AC power fails, the battery back-up will power the Alarm for a short time if the 9V battery is fresh and correctly installed. If AC power fails and the battery is dead or missing, the Alarm cannot operate.

Make sure the alarm is not receiving excessively noisy power (e.g., from major appliances on the same circuit, generators, solar power, light dimmers, or fluorescent lighting), as this may damage the Alarm.

Find the pair of self-adhesive labels included with this CO Alarm:

NOTE: A qualified appliance technician is defined as “a person, firm, corporation, or company that either in person or through a representative, is engaged in and responsible for the installation, testing, servicing, or replacement of heating, ventilation, air conditioning (HVAC) equipment, combustion appliances and equipment, and/or gas fireplaces or other decorative combustion equipment.”

How to Install Your CO Alarm

Tools You Will Need:

Parts of This CO Alarm

  1. Mounting Bracket
  2. Mounting Slot and Screw* (*Not Included)
  3. Locking Pins (break out of bracket)
  4. Hot (Black) AC Wire
  5. Neutral (White) AC Wire
  6. Interconnect Wire (Orange)
  7. Lever to Open Battery Compartment
  8. Swing-Out Battery Compartment
  9. Quick-Connect Power

[Diagram showing the parts of the alarm unit and mounting bracket]

Installation Steps

  1. Turn off power to the area where you will install this unit at the circuit breaker or fuse box. ELECTRICAL SHOCK HAZARD. Failure to turn off power may result in serious electrical shock, injury, or death.
  2. Remove the mounting bracket from the base. Position the screw slots on the mounting bracket over the screws in the junction box. Tighten the screws.
  3. Using wire nuts, connect the power connector to the AC power. Improper wiring of the power connector or the wiring leading to it will cause damage to the Alarm and may lead to a non-functioning Alarm.
    • STAND ALONE ALARM ONLY: Connect the white wire on the power connector to the neutral wire in the junction box. Connect the black wire on the power connector to the hot wire in the junction box. Tuck the orange wire inside the junction box (it is used for interconnect only).
    • INTERCONNECTED ALARMS ONLY: Strip off about 1/2” of the plastic coating on the orange interconnect wire on the power connector. Connect the white wire to the neutral wire (usually white) in the junction box. Connect the black wire to the hot wire (usually black) in the junction box. Connect the orange wire to the interconnect wire in the junction box. Repeat for each unit you are interconnecting. Never connect the hot or neutral wires in the junction box to the orange interconnect wire.
  4. Plug the power connector into the back of the CO Alarm.
  5. Position the base of the Alarm over the mounting bracket and turn. The Alarm can be positioned over the bracket every 60°. Turn the unit clockwise (right) until it is in place.
  6. Check all connections.
    • STAND ALONE ALARM ONLY: If you are installing only one unit, restore power to the junction box.
    • INTERCONNECTED ALARMS ONLY: If you are interconnecting multiple Alarms, repeat Steps 1-5 for each Alarm in the series. When you are finished, restore power to the junction box.
  7. ELECTRICAL SHOCK HAZARD. Do not restore power until all Alarms are completely installed. Restoring power before installation is complete may result in serious electrical shock, injury, or death.
  8. Make sure the CO Alarm is receiving AC power. Under normal operation, the red indicator light will shine continuously. If the red power indicator light does not light, TURN OFF POWER TO THE JUNCTION BOX and recheck all connections. If all connections are correct and the red power indicator still does not light when you restore power, the unit should be replaced immediately.
  9. Activate the battery back-up by removing the “Pull to Activate Battery Back-Up” tab. DO NOT remove the battery activation tab until AC power is turned on to conserve battery power.
  10. Test the CO Alarm. Press and hold the test button on the cover until the alarm sounds: 4 beeps, pause, 4 beeps, pause. In a series of interconnected Alarms, you must test each Alarm separately by pressing and holding the test button. Make sure all units alarm when each one is tested. If any unit in the series does not alarm during testing, TURN OFF POWER and recheck connections. If it does not alarm when you restore power, replace it immediately.

Special Requirements for Interconnected CO Alarms

[Diagram showing interconnect wiring: A. Unswitched 120VAC 60 Hz source, B. To Additional Alarms, Maximum = 18 Alarms, showing connections to junction box, power connector, wire nuts, neutral wire, interconnect wire, hot wire.]

Using the Locking Features

The optional locking features are designed to prevent unauthorized removal of the battery or alarm. It is not necessary to activate the locks in single-family households where unauthorized battery or alarm removal is not a concern.

These CO Alarms have two separate locking features: one locks the battery compartment, and the other locks the CO Alarm to the mounting bracket. You can choose to use either feature independently, or use them both.

Tools You Will Need:

Both locking features use locking pins, molded into the mounting bracket. Using needle-nose pliers, remove one or both pins, depending on which locking features you use.

[Diagram showing locking pin and its location]

The Battery Compartment Lock

To Lock the Battery Compartment:

  1. Do not lock the battery compartment until you have activated the battery and tested the battery back-up.
  2. Activate the battery back-up by removing the “Pull to Activate Battery Back-Up” tab. Push and hold the test button on the CO Alarm’s cover until you hear an acknowledge chirp and the alarm sounds: 4 beeps, pause, 4 beeps, pause. If the unit does not alarm during testing, DO NOT lock the battery compartment! Install a new battery and test again. If it still does not alarm, replace the CO Alarm immediately.
  3. Using needle-nose pliers, detach one locking pin from the mounting bracket.
  4. Push the locking pin through the black dot on the label on the back of the CO Alarm.

To Unlock the Battery Compartment:

  1. Once the CO Alarm is installed, you must disconnect it from the AC power before unlocking the battery compartment.
  2. ELECTRICAL SHOCK HAZARD. Turn off the power to the area where the CO Alarm is installed before removing it from the mounting bracket. Failure to turn off the power first may result in serious electrical shock, injury, or death.
  3. Remove the CO Alarm from the mounting bracket. If the unit is locked to the bracket, see the section “To Deactivate the Locking Feature.”
  4. Disconnect the power connector by gently prying it away from the back of the CO Alarm.
  5. Insert a flathead screwdriver under the head of the locking pin, and gently pry it out of the battery compartment lock. (If you plan to relock the battery compartment, save the locking pin.)
  6. To relock the battery compartment, close the battery door and reinsert the locking pin in the lock.
  7. Reconnect the power connector to the back of the CO Alarm, reattach the CO Alarm to the mounting bracket, and restore the power.

When replacing the battery, always test the CO Alarm before relocking the battery compartment.

The Mounting Bracket Lock

To Activate the Bracket Lock:

  1. Using needle-nose pliers, detach one locking pin from the mounting bracket.
  2. Insert the locking pin into the lock located on the pivoting hinge of the battery door.
  3. When you attach the CO Alarm to the mounting bracket, the locking pin’s head will fit into a notch on the bracket.

To Deactivate the Bracket Lock:

  1. ELECTRICAL SHOCK HAZARD. Turn off the power to the area where the CO Alarm is installed before removing it from the mounting bracket. Failure to turn off the power first may result in serious electrical shock, injury, or death.
  2. Always discharge the branch circuit before servicing an AC or AC/DC CO Alarm. First, turn off the AC power at the circuit breaker or fuse box. Next, remove the battery from Alarms with battery back-up. Finally, press and hold the test button.
  3. Insert a flathead screwdriver between the mounting bracket pin and the mounting bracket.
  4. Pry the CO Alarm away from the bracket by turning both the screwdriver and the CO Alarm counterclockwise (left) at the same time.

To Permanently Remove the Bracket Lock:

Insert the flathead screwdriver between the locking pin and the lock, and pry the pin out of the lock.

If Your CO Alarm Sounds

Activation of your CO Alarm indicates the presence of carbon monoxide (CO) which can kill you. When your CO Alarm sounds, you must not ignore it!

If the Alarm Sounds:

  1. Operate the Test/Silence button to silence the alarm.
  2. Call your emergency services, fire department, or 911. Write down the number of your local emergency service here: _________________________________
  3. Immediately move to fresh air—outdoors or by an open door or window. Do a head count to check that all persons are accounted for. Do not re-enter the premises, or move away from the open door or window until the emergency services responder has arrived, the premises have been aired out, and your CO Alarm remains in its normal condition.
  4. After following steps 1-3, if your CO Alarm reactivates within a 24-hour period, repeat steps 1-3 and call a qualified appliance technician to investigate for sources of CO from fuel-burning equipment and appliances, and inspect for proper operation of this equipment. If problems are identified during this inspection, have the equipment serviced immediately. Note any combustion equipment not inspected by the technician, and consult the manufacturers’ instructions, or contact the manufacturers directly, for more information about CO safety and this equipment. Make sure that motor vehicles are not, and have not, been operating in an attached garage or adjacent to the residence. Write down the number of a qualified appliance technician here: _________________________________________________________________

Alarms have various limitations. See “General Limitations of CO Alarms” for details.

Using the Silence Features

NEVER disconnect the power to your CO Alarm to silence the horn—use the silence feature. Disconnecting the CO Alarm removes your protection! See previous page for details on responding to an alarm.

The Silence Feature is intended to temporarily silence your CO Alarm’s alarm horn while you correct the problem—it will not correct a CO problem. While the Alarm is silenced, it will continue to monitor the air for CO. When CO reaches alarm level, the unit will sound—repeating horn pattern: 4 beeps, a pause, 4 beeps, etc. Press and hold the Test/Silence button until the horn is silent. The Silence cycle will last approximately 4 minutes.

To silence an interconnected series of Alarms, you must press the Test/Silence button on the initiating alarm (the unit with the flashing red light). If you press the Test/Silence on any other Alarm, it will only silence that unit, not the whole interconnected series.

NOTE: After the 4-minute silence cycle, the CO Alarm re-evaluates present CO levels and responds accordingly. If CO levels remain potentially dangerous—or start rising higher—the horn will start sounding again.

Silencing the Low Battery Warning

This silence feature can temporarily quiet the low battery warning “chirp” for up to 8 hours if AC power is present. Press the Test/Silence button on the alarm cover. Once the low battery warning “chirp” silence feature is activated, the unit continues to flash the red light once a minute for 8 hours. After 8 hours, the low battery “chirp” will resume. Replace the battery as soon as possible, to maintain protection in the event of a power outage.

Silencing the End of Life Signal

This silence feature can temporarily quiet the End of Life warning “chirp” for up to 2 days. You can silence the End of Life warning “chirp” by pressing the Test/Silence button. The horn will chirp, acknowledging that the End of Life silence feature has been activated.

After approximately 2 days, the End of Life “chirp” will resume. After approximately 2-3 weeks, the End of Life warning cannot be silenced.

Latching Features

Alarm Latch: Activated after an Alarm is exposed to alarm levels of carbon monoxide. This feature will only work with AC power. After CO levels drop below alarm levels, the Red LED will begin to flash On for 2 seconds and Off for 2 seconds. It will continue to flash or “latch” until you clear it by testing the Alarm. This feature helps emergency responders, investigators, or service technicians identify which unit(s) in your home were exposed to alarm levels of carbon monoxide.

Interconnected Alarms: Latching Alarm Indicator shows which Alarm(s) in the series were exposed to alarm levels of carbon monoxide. The Latching Alarm Indicator stays ON until you clear it, so it can alert you to a CO Alarm that occurred while you were away from home, even though CO present in the air has dropped below alarm levels.

Low Battery Latch: Activated when the Alarm is in the “low battery condition”. When this occurs, the red LED flashes 4 seconds On/2 seconds Off. This feature is designed to help you identify which Alarm needs to have the battery replaced. Although the Alarm will sound the low battery chirp approximately once every minute, sometimes during the initial stages of “low battery”, the Alarm will chirp at greater intervals than one minute, sometimes up to several hours, until the battery reaches a steady low battery level. This innovative feature eliminates the frustration of waiting for and/or identifying which unit is chirping.

Weekly Testing

Push and hold the Test/Silence button until you hear an acknowledge chirp and a loud alarm sounds—4 beeps, pause, 4 beeps. This sequence should last for 10 seconds. If the Alarm ever fails to test properly, replace it immediately. If the Alarm is not working properly, refer to “Limited Warranty”.

Regular Maintenance

To keep the CO Alarm working properly:

The Low (or Missing) Battery Warning (CO5120PDBN): The horn will “chirp” once a minute and the word “bat” will flash on and off on the display.

Replacing the Battery

Choosing a Replacement Battery:

This unit requires one standard 9V alkaline battery. The following alkaline batteries are acceptable as replacements: Duracell MN1604, Energizer 522, Ultralife U9VL-J, and Ultralife U9VL-J-P. These replacement batteries are commonly available at local retail stores.

What You Need to Know About CO

What is CO?

CO is an invisible, odorless, tasteless gas produced when fossil fuels do not burn completely, or are exposed to heat (usually fire). Electrical appliances typically do not produce CO.

These fuels include: Wood, coal, charcoal, oil, natural gas, gasoline, kerosene, and propane. Common appliances are often sources of CO. If they are not properly maintained, are improperly ventilated, or malfunction, CO levels can rise quickly. CO is a real danger now that homes are more energy efficient. “Air-tight” homes with added insulation, sealed windows, and other weatherproofing can “trap” CO inside.

Symptoms of CO Poisoning

These symptoms are related to CO POISONING and should be discussed with ALL household members.

This CO Alarm measures exposure to CO over time. It alarms if CO levels are extremely high in a short period of time, or if CO levels reach a certain minimum over a long period of time. The CO Alarm generally sounds an alarm before the onset of symptoms in average, healthy adults.

Why is this important? Because you need to be warned of a potential CO problem while you can still react in time. In many reported cases of CO exposure, victims may be aware that they are not feeling well, but become disoriented and can no longer react well enough to exit the building or get help. Also, young children and pets may be the first affected. The average healthy adult might not feel any symptoms when the CO Alarm sounds. However, people with cardiac or respiratory problems, infants, unborn babies, pregnant mothers, or elderly people can be more quickly and severely affected by CO. If you experience even mild symptoms of CO poisoning, consult your doctor immediately!

Finding the Source of CO After an Alarm

Carbon monoxide is an odorless, invisible gas, which often makes it difficult to locate the source of CO after an alarm. These are a few of the factors that can make it difficult to locate sources of CO:

Because CO may dissipate by the time an investigator arrives, it may be difficult to locate the source of CO. BRK Brands, Inc. shall not be obligated to pay for any carbon monoxide investigation or service call.

Potential Sources of CO in the Home

Transient CO Problems:

“Transient” or on-again, off-again CO problems can be caused by outdoor conditions and other special circumstances. The following conditions can result in transient CO situations:

  1. Excessive spillage or reverse venting of fuel appliances caused by outdoor conditions such as:
    • Wind direction and/or velocity, including high, gusty winds. Heavy air in the vent pipes (cold/humid air with extended periods between cycles).
    • Negative pressure differential resulting from the use of exhaust fans.
    • Several appliances running at the same time competing for limited fresh air.
    • Vent pipe connections vibrating loose from clothes dryers, furnaces, or water heaters.
    • Obstructions in or unconventional vent pipe designs which can amplify the above situations.
  2. Extended operation of unvented fuel burning devices (range, oven, fireplace).
  3. Temperature inversions, which can trap exhaust close to the ground.
  4. Car idling in an open or closed attached garage, or near a home.

These conditions are dangerous because they can trap exhaust in your home. Since these conditions can come and go, they are also hard to recreate during a CO investigation.

How Can I Protect My Family?

A CO Alarm is an excellent means of protection. It monitors the air and sounds a loud alarm before carbon monoxide levels become threatening for average, healthy adults. A CO Alarm is not a substitute for proper maintenance of home appliances.

To help prevent CO problems and reduce the risk of CO poisoning:

Underwriters Laboratories Inc. UL2034

What Levels of CO Cause an Alarm?

Underwriters Laboratories Inc. Standard UL2034 requires residential CO Alarms to sound when exposed to levels of CO and exposure times as described below. They are measured in parts per million (ppm) of CO over time (in minutes).

UL2034 Required Alarm Points*:

*Approximately 10% COHb exposure at levels of 10% to 95% Relative Humidity (RH).

The unit is designed not to alarm when exposed to a constant level of 30 ppm for 30 days.

CO Alarms are designed to alarm before there is an immediate life threat. Since you cannot see or smell CO, never assume it’s not present.

Standards: Underwriters Laboratories Inc. Single and Multiple Station Carbon Monoxide Alarms UL2034.

According to Underwriters Laboratories Inc. UL2034, Section 1-1.2: “Carbon monoxide alarms covered by these requirements are intended to respond to the presence of carbon monoxide from sources such as, but not limited to, exhaust from internal-combustion engines, abnormal operation of fuel-fired appliances, and fireplaces. CO Alarms are intended to alarm at carbon monoxide levels below those that could cause a loss of ability to react to the dangers of Carbon Monoxide exposure.” This CO Alarm monitors the air at the Alarm, and is designed to alarm before CO levels become life threatening. This allows you precious time to leave the house and correct the problem. This is only possible if Alarms are located, installed, and maintained as described in this manual.

Gas Detection at Typical Temperature and Humidity Ranges:

The CO Alarm is not formulated to detect CO levels below 30 ppm typically. UL tested for false alarm resistance to Methane (500 ppm), Butane (300 ppm), Heptane (500 ppm), Ethyl Acetate (200 ppm), Isopropyl Alcohol (200 ppm), and Carbon Dioxide (5000 ppm). Values measure gas and vapor concentrations in parts per million.

Audible Alarm: 85 dB minimum at 10 feet (3 meters).

General Limitations of CO Alarms

Troubleshooting Guide

ELECTRICAL SHOCK HAZARD. Turn off the power to the area where the CO Alarm is installed BEFORE removing it from the mounting bracket or checking any electrical connections! Failure to turn off the power first may result in serious electrical shock, injury, or death.

If the Alarm...Problem...You should...
Red light is OFF. Unit will not alarm when you press the Test/Silence button.Unit may not be receiving any power.Check the AC power supply. Make sure the power connector is securely attached to the Alarm. Make sure a fresh 9V battery is installed to power the battery back-up.
Red light flashes once a minute (horn is silent). (CO5120PDBN display reads "bat").Alarm is not receiving AC power. Unit is operating on DC battery back-up.Check the AC power supply.
The red light flashes and the horn "chirps" once a minute. (CO5120PDBN display flashes "bat").Low battery warning.Replace the 9V battery in the battery back-up. Disconnect AC power before changing the battery.
Once a minute, the alarm sounds 3 "chirps", and the red light flashes three times. (CO5120PDBN display reads "Err").MALFUNCTION SIGNAL. Based on its Self Test diagnostics, the unit has detected a malfunction. The unit needs to be replaced.Make sure a fresh 9V battery is installed. If unit still isn't functioning – REPLACE IT. Units under warranty should be returned to manufacturer for replacement. See "Limited Warranty" for details.
The light flashes (Red) and the horn sounds 5 "chirps" every minute. (CO5120PDBN display reads "End").END OF LIFE SIGNAL. CO Alarm needs to be replaced.Immediately replace the CO Alarm.
CO Alarm goes back into alarm 4 minutes after you press the Test/Silence button.CO levels are still potentially dangerous.Refer to “If Your CO Alarm Sounds” for details on how to respond to an alarm. If anyone is feeling ill, EVACUATE your home immediately and call 911.
CO Alarm sounds frequently even though no high levels of CO are revealed in an investigation.The CO Alarm may be improperly located. Refer to “Where to Install CO Alarms.”Relocate your Alarm. If frequent alarms continue, have home rechecked for potential CO problems. You may be experiencing an intermittent CO problem.

*For a list of acceptable replacement batteries, see “Regular Maintenance.”

If you have any questions that cannot be answered by reading this manual, call Consumer Affairs: 1-800-323-9005.

Limited Warranty

BRK Brands, Inc. (“BRK”), the maker of First Alert® brand and BRK® brand products, warrants that for a period of ten years from the date of purchase, this product will be free from defects in material and workmanship. BRK, at its option, will repair or replace this product or any component of the product found to be defective during the warranty period. Replacement will be made with a new or remanufactured product or component. If the product is no longer available, replacement may be made with a similar product of equal or greater value. This is your exclusive warranty.

This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not transferable. Keep the original sales receipt. Proof of purchase is required to obtain warranty performance. BRK dealers, service centers, or retail stores selling BRK products do not have the right to alter, modify or any way change the terms and conditions of this warranty.

This warranty does not cover normal wear of parts or damage resulting from any of the following: negligent use or misuse of the product, use on improper voltage or current, use contrary to the operating instructions, disassembly, repair or alteration by anyone other than BRK or an authorized service center. Further, the warranty does not cover Acts of God, such as fire, flood, hurricanes and tornadoes or any batteries that are included with this unit.

BRK shall not be liable for any incidental or consequential damages caused by the breach of any express or implied warranty. Except to the extent prohibited by applicable law, any implied warranty of merchantability or fitness for a particular purpose is limited in duration to the duration of the above warranty. Some states, provinces, or jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state or province to province.

How to Obtain Warranty Service

Service: If service is required, do not return the product to your retailer. In order to obtain warranty service, contact the Consumer Affairs Division at 1-800-323-9005. To assist us in serving you, please have the model number and date of purchase available when calling.

For Warranty Service return to: BRK Brands, Inc., 1301 Joe Battle, El Paso, TX 79936

Battery: BRK Brands, Inc. makes no warranty, express or implied, written or oral, including that of merchantability or fitness for any particular purpose with respect to battery.

Visit www.firstalert.com for more information.

For Your Records:

Replace alarm 10 years after installation. Please write the date in the space provided: _____________/____________Month/Year

The alarm will also provide an audible End-of-Life Signal approximately 10 years after installation to remind you to replace the unit. The End-of-Life Signal can be silenced for up to 2 days. Do not unplug the alarm or remove the batteries until you get replacement.

PDF preview unavailable. Download the PDF instead.

256fece2 Adobe InDesign CC 2015 (Macintosh) Adobe PDF Library 15.0

Related Documents

Preview First Alert CO5120BN & CO5120PDBN AC Powered Carbon Monoxide Alarm User Manual
Comprehensive user manual for First Alert CO5120BN and CO5120PDBN AC-powered Carbon Monoxide Alarms, covering installation, operation, safety, troubleshooting, and maintenance. Learn how to protect your home and family from carbon monoxide.
Preview First Alert CO5120BN/CO5120PDBN Carbon Monoxide Alarm User Manual and Installation Guide
Comprehensive user manual and installation guide for the First Alert CO5120BN and CO5120PDBN AC-powered Carbon Monoxide Alarms, covering features, installation, operation, maintenance, and safety information.
Preview First Alert CO5120BN/CO5120PDBN Carbon Monoxide Alarm User Manual and Installation Guide
Comprehensive user manual and installation guide for the First Alert CO5120BN and CO5120PDBN AC-powered Carbon Monoxide Alarms. Includes safety information, installation instructions, troubleshooting, maintenance, and warranty details.
Preview First Alert CO5120BN/CO5120PDBN Carbon Monoxide Alarm User Manual
This user manual provides comprehensive information on the First Alert CO5120BN and CO5120PDBN AC-powered Carbon Monoxide Alarms. It covers key features, installation instructions, safety guidelines, operation, troubleshooting, and maintenance for effective carbon monoxide detection in residential settings.
Preview First Alert CO5120BN & CO5120PDBN Carbon Monoxide Alarm User Manual
Comprehensive user manual for First Alert CO5120BN and CO5120PDBN AC-powered Carbon Monoxide Alarms with battery backup. Includes installation, operation, safety, maintenance, and troubleshooting information.
Preview First Alert CO5120BN/CO5120PDBN User Manual: AC Powered Carbon Monoxide Alarm Guide
Comprehensive user manual for the First Alert CO5120BN and CO5120PDBN AC-powered Carbon Monoxide Alarms. Learn about installation, operation, safety features, and maintenance for reliable carbon monoxide detection in your home.
Preview First Alert SC7010B Smoke and Carbon Monoxide Alarm User Manual
User manual for the First Alert SC7010B AC powered smoke and carbon monoxide alarm. Learn about installation, testing, maintenance, troubleshooting, and safety features for home protection against fire and CO hazards.
Preview First Alert SC9120B Smoke & Carbon Monoxide Alarm User Manual
User manual for the First Alert SC9120B AC Powered Smoke & Carbon Monoxide Alarm with Battery Back-up. Includes installation, operation, safety tips, and troubleshooting.