User Guide for CYPRESS models including: CY7113, EZ-PD PMG1-S3 Prototyping Kit

CY7113 EZ-PD™ PMG1-S3 prototyping kit Quick Start Guide

CY7113, EZ-PD™, PMG1-S3, prototyping, kit, Quick, Start, Guide

Infineon

CY7113 EZ-PD™ PMG1-S3 prototyping kit Quick Start Guide

adapter (e.g., Apple 30 W USB-C power adapter) with a compatible USB PD 3.0-compliant ... See the CY7113 kit user guide (available as part of the CY7113.

CY7113 EZ-PD™ PMG1-S3 MCU prototyping kit Quick Start Guide

PDF preview unavailable. Download the PDF instead.

Infineon-CY7113 EZ-PD PMG1-S3 Prototyping Kit Quick Start Guide-UserManual-v01 00-EN
Quick start guide
CY7113 EZ-PDTM PMG1-S3 prototyping kit
The CY7113 EZ-PDTM PMG1-S3 prototyping kit is a development platform to design products which can be powered from a high-voltage USB PD port, and also need a microcontroller with CAPSENSETM capability to implement different applications. This platform is compliant with the USB PD 3.0 protocol and can support up to 100 W (20 V, 5A) of power consumption. It also supports two self-capacitance-based CAPSENSETM buttons and one 5-segment slider.

EZ-PDTM PMG1-S3 Reset switch (SW3)
User switch (SW2)

DC_OUT terminal block (J9)

Power LED (LED4) CAPSENSETM buttons(CSB1, CSB2) and feedback LEDs (LED5, LED6)
VDDIO3_VIN3 J6 GND
LSEWD23CC__CCIINN12 PP33..56//UUAARRRETTPPPPPPPS__3322225RET.......TXX3034212
GPPN55..D35

KitProg3

KitProg3 VBUS LED (LED2)

EZ-PDTM PMG1-S3 microcontroller (U3) Power selection jumper (J5) User LED (LED3) EZ-PDTM PMG1-S3 USB PD sink port (J10)
CAPSENSETM slider (CSS1) and feedback LEDs (LED7 ­ LED11)
J7 VVDCODDNN_SRC GPPPPPPPPPPP11441166066N...........D56104332010//II22CC__SSDCLA GPPVPPS1155NY....D2101S//_SSIWWNDD__ICOLK
KitProg3 mode switch (SW1)

KitProg3 status LED (LED1)

KitProg3 USB Type-C port (J1)

www.cypress.com/CY7113

Quick start guide
Before you start > Ensure that you have a USB PD 3.0-compliant USB-C power
adapter (e.g., Apple 30 W USB-C power adapter) with a compatible USB PD 3.0-compliant Type-C cable. > Download and unzip the CY7113 release package from the CY7113 web page (cypress.com/CY7113). > Ensure that the jumper shunt on the power selection jumper (J5) is placed at position 1 ­ 2 to select the USB-C power adapter as the power source.
Step 1: Hardware connection > Connect the USB PD sink port (J10) of the CY7113 board
to the USB-C power adapter using the USB Type-C cable. > Confirm that the power LED (LED4) glows green and
the user LED (LED3) blinks green. Now, the kit is ready for use.
Step 2: Evaluating the USB PD sink functionality > Measure the DC_OUT voltage by connecting a multimeter to
the terminal block (J9). Confirm that the DC_OUT voltage value is within the 4.75 V ­ 21.00 V range. The actual value is determined by the maximum voltage which the USB-C power adapter can supply. > Remove the multimeter and connect an external load to the terminal block (J9).
! The maximum current that can be consumed by an external load cannot exceed 5 A.
Step 3: Evaluating the CAPSENSETM functionality > Touch a CAPSENSETM button (CSB1/CSB2) by placing a finger on
the circular button area. The feedback LED associated with the button (LED5/LED6) glows green until the finger is lifted. > Slide the finger on the 5-segment slider (CSS1). The feedback LED associated with each slider segment (LED7 ­ LED11) glows green during the finger contact period.
Next steps > See the CY7113 kit user guide (available as part of the CY7113
kit release package) to learn more about the kit features and how to develop applications using ModusToolboxTM software.

CY7113 kit contents From USB-C power adapter
Powering the CY7113 board From USB-C power adapter
USB PD sink setup
Evaluating CAPSENSETM features

www.infineon.com
Published by Infineon Technologies AG 81726 Munich, Germany © 2021 Infineon Technologies AG. All Rights Reserved.
Document Number: 002-33646 Rev. ** Date: 07 / 2021

Please note! THIS DOCUMENT IS FOR INFORMATION PURPOSES ONLY AND ANY INFORMATION GIVEN HEREIN SHALL IN NO EVENT BE REGARDED AS A WARRANTY, GUARANTEE OR DESCRIPTION OF ANY FUNCTIONALITY, CONDITIONS AND/OR QUALITY OF OUR PRODUCTS OR ANY SUITABILITY FOR A PARTICULAR PURPOSE. WITH REGARD TO THE TECHNICAL SPECIFICATIONS OF OUR PRODUCTS, WE KINDLY ASK YOU TO REFER TO THE RELEVANT PRODUCT DATA SHEETS PROVIDED BY US. OUR CUSTOMERS AND THEIR TECHNICAL DEPARTMENTS ARE REQUIRED TO EVALUATE THE SUITABILITY OF OUR PRODUCTS FOR THE INTENDED APPLICATION.
WE RESERVE THE RIGHT TO CHANGE THIS DOCUMENT AND/OR THE INFORMATION GIVEN HEREIN AT ANY TIME.

Additional information For further information on technologies, our products, the application of our products, delivery terms and conditions and/or prices, please contact your nearest Infineon Technologies office (www.infineon.com).
Warnings Due to technical requirements, our products may contain dangerous substances. For information on the types in question, please contact your nearest Infineon Technologies office.
Except as otherwise explicitly approved by us in a written document signed by authorized representatives of Infineon Technologies, our products may not be used in any lifeendangering applications, including but not limited to medical, nuclear, military, life-critical or any other applications where a failure of the product or any consequences of the use thereof can result in personal injury.


Adobe PDF library 15.00