Submittal Data Sheet

Indoor Unit Model#: EZ-60-AHB | Outdoor Unit Model#: EZ-60-HPB

Product: 60K DIYCOOL R454B Ducted Air Handler & Ext. Heat Pump Condenser

Efficiency

Cooling Heating
SEER2 EER2 HSPF2-4 COP
16.0 10.0 9.0 3.10

Cooling Performance

Rated Capacity 54000 Btu/hr
Min/Max Capacity 11400 ~ 56300 Btu/hr
Moisture Removal 5.87 L/h
Standard Operating Range (°F/°C) -22 ~ 122 (-30 ~ 50)
Conditions: Indoor: 80°F Dry Bulb / 67°F Wet Bulb
Outdoor: 95°F Dry Bulb / 75°F Wet Bulb

Heating Performance

1. @ 47°F Rated Capacity 56000 Btu/hr
1. @ 47°F Min/Max Capacity 8100 ~ 64500 Btu/hr
2. @ 17°F Rated Capacity 45000 Btu/hr
3. @ 5°F Rated Capacity / COP 52000 Btu/hr / 1.8
3. @ 5°F Max Capacity 52000 Btu/hr
Standard Operating Range (°F/°C) -22 ~ 75 (-30 ~ 24)
1. Rated Heating Conditions: Indoor: 70°F Dry Bulb / 60°F Wet Bulb
Outdoor: 47°F Dry Bulb / 43°F Wet Bulb
2. Rated Heating Conditions: Indoor: 70°F Dry Bulb / 60°F Wet Bulb
Outdoor: 17°F Dry Bulb / 15°F Wet Bulb
3. Heating Conditions, Compressor Operating at Max. Frequency Indoor: 70°F Dry Bulb / 60°F Wet Bulb
Outdoor: 5°F Dry Bulb / 5°F Wet Bulb

Indoor Unit Specifications

ESP (inches of Water Gauge) 0 - 0.8
Indoor Air Flow (Turbo/H/M/L/Si) (CFM) 1807.0 / 1583.3 / 1359.7 / 1136.0 / NA Cubic Feet per Minute
Indoor Noise Level (Turbo/H/M/L/Si) (dBA) 54.5 / 52 / 49.5 / 34.5 / NA decibels A-weighted
Dimension (Width x Depth x Height) 21.02 x 24.49 x 52.99 inches
534.0 x 622.0 x 1346.0 mm
Package (Width x Depth x Height) 27.95 x 26.77 x 56.50 inches
710 x 680 x 1435 mm
Net/Gross Weight 162.92 / 190.92 pounds
73.9 / 86.6 kilograms

Outdoor Unit Specifications

Compressor Type TWIN-ROTARY
Compressor Model ETPQ480D66UMU1
Refrigerant R454B
Refrigerant Oil Charge (mL) 1300 milliliters
Refrigerant Oil VG75
Outdoor Air Flow (Max) (CFM) 2648.6 Cubic Feet per Minute
Outdoor Noise Level (dBA) 65 decibels A-weighted
Dimension (Width x Depth x Height) 37.48 x 16.34 x 52.48 inches
952.0 x 415.0 x 1333.0 mm
Package (Width x Depth x Height) 43.11 x 19.49 x 58.27 inches
1095 x 495 x 1480 mm
Net/Gross Weight 242.95 / 275.13 pounds
110.2 / 124.8 kilograms

Electrical Specifications

Indoor Power Supply 115/208/230V, 60Hz, 1Ph
Indoor MCA (115V/208/230V) 14.5 / 11.0 Amps
Indoor MOP 15 Amps
Outdoor Power Supply 208/230V, 60Hz, 1Ph
Outdoor MCA 40 Amps
Outdoor MOP 40 Amps
Communication Wiring American Wire Gauge 20-2
Compressor RLA 31 Amps
Outdoor Fan Motor RLA 1.2 Amps
Outdoor Fan Motor W 85 Watts
Indoor Fan Motor RLA 8.3 Amps
Indoor Fan Motor W 750 Watts
System Power Input @ Cooling (W) 5400 (1540 ~ 6430) Watts
System Power Input @ Heating (W) 5300 (725 ~ 5970) Watts
MCA: Minimum circuit amps (A)
MOCP: Maximum overcurrent protection (A)
RLA: Rated load amps (A)
W: Fan motor rated output (W)

Refrigerant Piping Specifications

Throttle type (Indoor) Electronic Expansion Valve (EXV)
Throttle type (Outdoor) Electronic Expansion Valve (EXV)
Liquid Size 9.52mm (3/8in)
Gas Size 19mm (3/4in)
Max. Piping Length (ft/m) 246 feet (75 meters)
Max. Height Difference (ft/m) 98.4 feet (30 meters)
Max. Pre-charged Length (ft/m) 24.6 feet (7.5 meters)
Refrigerant Pre-charged Amount (oz/g) 183.42 ounces (5.2 grams)
Additional Charge of Refrigerant ((oz/ft)/(g/m)) 0.7 ounces/foot (65 grams/meter)
Connection Method Connector

Indoor Unit Dimensions

The indoor unit is depicted with various connection points and dimensions. Key features include:

The following table provides specific dimensions (A through K) for different models:

Dimension Label 24K Model 36K Model 48K/60K Model
inch mm inch mm inch mm
A: Model Height451143491245531346
B: Model Width17-1/24452153424-1/2622
C: Supply Air Opening Width15-5/839719-1/848622-5/8575
D: Return Air Opening Width15-1/838418-5/847322-1/8562
E: Model Depth215342153421534
F: Supply Air Opening Depth10-1/426010-1/426010-1/4260
G: Return Air Opening Depth18-3/447618-3/447618-3/4476
H: Supply Air Opening Clearance15/162415/162415/1624
I: Return Air Opening Side Clearance1-1/4321-1/4321-1/828
J: Return Air Opening Front Clearance1-1/2381-5/8411-5/841
K: Return Air Opening Back Clearance5/8165/8163/419

Outdoor Unit Dimensions

The outdoor unit is shown in front, side, and top views. Key dimensions are indicated:

Installation Instructions For Outdoor Unit

Clearance requirements for the outdoor unit are specified to ensure proper operation and airflow:

Note: The diagram uses arrows to indicate these clearance zones around the unit.

Fan Performance For Indoor Unit

The graph illustrates the fan performance of the indoor unit, plotting Air flow rate (CFM) on the vertical axis against External static pressure (in.w.c.) on the horizontal axis. The data is presented for four fan speed settings:

The graph shows that for each speed setting, the air flow rate generally decreases slightly as the external static pressure increases from 0 to 0.8 inches of Water Gauge.

Features

* For 36K model, rated cooling capacity/heating capacity at -4°F = 100%.

PDF preview unavailable. Download the PDF instead.

Infinity-DIYC-EZAHU-Sub-60-AHB-60-HPB-112224 Acrobat Distiller 25.0 (Windows)

Related Documents

Preview AHRI Certified Product Ratings: InfinityLiving EZ-48-HPB/EZ-48-AHB Heat Pump
Official AHRI Certified product rating certificate for the InfinityLiving EZ-48-HPB outdoor unit and EZ-48-AHB indoor unit heat pump system. Details include cooling capacity, SEER2, EER2, heating capacity, HSPF2 ratings, and potential eligibility for U.S. federal tax credits.
Preview AHRI Certified Product Ratings Certificate - InfinityLiving EZ-48Z-M5
Official AHRI product rating certificate for the InfinityLiving EZ-48Z-M5 multi-split heat pump, detailing cooling and heating capacities, SEER, EER, and HSPF ratings according to AHRI 210/240 standards.