Owner's Manual for MEAN WELL models including: SE-1000 series 1000W Single Output Power Supply, SE-1000 series, 1000W Single Output Power Supply, Output Power Supply, Power Supply, Supply

SE-1000

Rio Lai

SE-1000-12 MEAN WELL USA Inc. - РКС Компоненти - РАДІОМАГ


File Info : application/pdf, 3 Pages, 551.63KB

PDF preview unavailable. Download the PDF instead.

se-1000-spec
1000W Single Output Power Supply

SE-1000 series

 


  

       

User's Manual

 https://www.meanwell.com/serviceGTIN.aspx



SPECIFICATION

 

UL62368-1 TPTC004 IEC62368-1

MODEL

SE-1000-5

SE-1000-9

SE-1000-12

SE-1000-15

SE-1000-24

SE-1000-48

DC VOLTAGE

5V

9V

12V

15V

24V

48V

RATED CURRENT

150A

100A

83.3A

66.7A

41.7A

20.8A

CURRENT RANGE

0 ~ 150A

0 ~ 100A

0 ~ 83.3A

0 ~ 66.7A

0 ~ 41.7A

0 ~ 20.8A

RATED POWER

750W

900W

999.6W

1000.5W

1000.8W

998.4W

RIPPLE & NOISE (max.) Note.2 150mVp-p

150mVp-p

150mVp-p

150mVp-p

200mVp-p

200mVp-p

OUTPUT

VOLTAGE ADJ. RANGE

3.3 ~ 5.5V

VOLTAGE TOLERANCE Note.3 ±1.0%

LINE REGULATION

±0.5%

LOAD REGULATION

±1.0%

7.5 ~ 10V ±1.0% ±0.5% ±0.5%

10 ~ 13.5V ±1.0% ±0.5% ±0.5%

13.5 ~ 16.5V ±1.0% ±0.5% ±0.5%

22 ~ 27.5V ±1.0% ±0.5% ±0.5%

43 ~ 56V ±1.0% ±0.5% ±0.5%

SETUP, RISE TIME

1500ms, 50ms/230VAC 1500ms, 50ms/115VAC at full load

HOLD UP TIME (Typ.)

20ms/230VAC 15ms/115VAC at full load

VOLTAGE RANGE

90 ~ 132VAC / 180 ~ 264VAC selected by TB2 254 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

INPUT

EFFICIENCY (Typ.)

81%

84%

85%

86%

88%

89%

AC CURRENT (Typ.)

17.5A/115VAC 10A/230VAC

INRUSH CURRENT (Typ.) 35A/115VAC 55A/230VAC

LEAKAGE CURRENT

<2.5mA / 240VAC

OVERLOAD

105 ~ 125% rated output power Protection type : Shut down o/p voltage, re-power on to recover

PROTECTION OVER VOLTAGE

5.75 ~ 6.75V

10.4 ~ 12.2V

13.8 ~ 16.2V

18 ~ 21V

Protection type : Shut down o/p voltage, re-power on to recover

28 ~ 32.4V

57.6 ~ 67.2V

OVER TEMPERATURE

Shut down o/p voltage, recovers automatically after temperature goes down

FUNCTION

DC_OK SIGNAL REMOTE CONTROL WORKING TEMP.

PSU turn on:3.3V ~ 5.6V PUS turn off:0 ~ 1V RC+/RC-: 0 ~ 0.8V power on; 4 ~ 10V power off -20 ~ +60 (Refer to "Derating Curve")

WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT

20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH ±0.05%/ (0 ~ 50)

VIBRATION SAFETY STANDARDS

10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL62368-1, BSMI CNS15598-1, EAC TP TC 004 approved; Design refer to BS EN/EN62368-1

WITHSTAND VOLTAGE

I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC

ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH

Parameter

Standard

Test Level / Note

Conducted

BS EN/EN55032 (CISPR32),CNS15936 Class A

EMC EMISSION

Radiated

BS EN/EN55032 (CISPR32),CNS15936 Class A

Harmonic Current

BS EN/EN61000-3-2

-----

SAFETY &
EMC (Note 4)

Voltage Flicker BS EN/EN55035, BS EN/EN61000-6-2 Parameter

BS EN/EN61000-3-3 Standard

----Test Level / Note

ESD

BS EN/EN61000-4-2

Level 3, 8KV air ; Level 2, 4KV contact

Radiated

BS EN/EN61000-4-3

Level 3

EMC IMMUNITY

EFT / Burst Surge

BS EN/EN61000-4-4 BS EN/EN61000-6-2

Level 3 2KV/Line-Line 4KV/Line-Earth

Conducted

BS EN/EN61000-4-6

Level 3

Magnetic Field

BS EN/EN61000-4-8

Level 4

Voltage Dips and Interruptions

BS EN/EN61000-4-11

>95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods

MTBF

1273.6K hrs min. Telcordia SR-332 (Bellcore) ; 251.6K hrs min. MIL-HDBK-217F (25)

OTHERS DIMENSION

278*127*63.5mm (L*W*H)

PACKING

2.5Kg; 6pcs/16Kg/1.38CUFT

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to

perform these EMC tests, please refer to "EMI testing of component power supplies."

(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)

5. By using UVP circuit, PSU will not turn on direct by in AC continue ON/OFF condition within 5 sec.

6. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft).

7. This power supply does not meet the harmonic current requirements outlined by EN61000-3-2. Please do not use this power supply

under the following conditions:

a) the end-devices is used within the European Union, and

b) the end-devices is connected to public mains supply with 220Vac or greater rated nominal voltage, and

c) the power supply is:

- installed in end-devices with average or continuous input power greater than 75W, or

- belong to part of a lighting system

Exception:

Power supplies used within the following end-devices do not need to fulfill EN61000-3-2

a) professional equipment with a total rated input power greater than 1000W;

b) symmetrically controlled heating elements with a rated power less than or equal to 200W

 Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Downloaded from Arrow.com.

File Name:SE-1000-SPEC 2024-05-20

9.25 11

1000W Single Output Power Supply

SE-1000 series

Mechanical Specification
19 max.

278 171.5
8-M4(Both Sides) 171.5

38 12.5

16 63.5

Case No. 935B Unit:mm
19 2-M4 8.5
39 max.
19

12.25

LED

CN3 ADJ 6 1+

4-M4

127

Air flow direction

1 2 3

1 2

TB1 TB2

101.5

OUTPUT +V
-V

TB1:AC input terminal

Pin No. Assignment

1

AC/L

2

AC/N

3

FG

TB2:110/220V Change

Pin No. 110V 220V

1

2

Short Open

Control Pin (CN3) : JST B6B-XH or equivalent

Pin No.

Assignment

Pin No. Assignment

1

DC_OK Signal

4

+S

2

DC_OK GND

5

RC-

3

-S

6

RC+

Mating Housing JST XHP
or equivalent

Block Diagram

I/P (TB1)

EMI FILTER

Derating Curve

ACTIVE INRUSH CURRENT LIMITING

110/220V(TB2)

RECTIFIERS

POWER SWITCHING

RECTIFIERS &
FILTER

O.V.P.

O.L.P. O.T.P.

PWM CONTROL
FAN LOCK PROTECTION

DETECTION CIRCUIT REMOTE CONTROL

AUX

FAN

POWER

Static Characteristics

Terminal JST SXH-001T or equivalent
fosc : 55KHz +S +V -V -S
DC_OK RC

100

Others

80
5V,12V 60 50 40

20

-20

0

10

20

30

40 45 50

60

70 (HORIZONTAL)

AMBIENT TEMPERATURE ()

100 90 80 70 60 50 40
90 180

180 ~ 264VAC 90 ~ 132VAC

95

100

115

132

190

200

230

264

INPUT VOLTAGE (VAC) 60Hz

File Name:SE-1000-SPEC 2024-05-20

LOAD (%) LOAD (%)

Downloaded from Arrow.com.

1000W Single Output Power Supply
Mechanical Specification
DC_OK Signal DC_OK Signal is the voltage difference between "DC_OK" and "G" pin output DC_OK Signal is a TTL level signal PSU turn on: 3.3 ~ 5.6V PSU turn off: 0 ~ 1V
+V

RC+ RC- +S -S

G

DC OK

CN3 ADJ + -V

Remote Sensing

G DC_OK
LOAD -+

+V

RC+ RC- +S -S

G

DC OK

Remote Control
Between RC+ and RC- Output SW OFF(0 ~ 0.8V) ON SW ON(4 ~ 10V) OFF

CN3 ADJ + -V -S LOAD +S -+
+V

RC+ RC- +S -S

G

DC OK

CN3 ADJ
+

SW RC+

External Power Source

I=6~20mA RC-

Connector for remote Control

-V
LOAD -+

Downloaded from Arrow.com.

SE-1000 series
File Name:SE-1000-SPEC 2024-05-20



References

CorelDRAW X6 Corel PDF Engine Version 16.1.0.843; modified using iText 5.5.6 ©2000-2015 iText Group NV (AGPL-version)