Owner's Manual for MEAN WELL models including: SE-1000 series 1000W Single Output Power Supply, SE-1000 series, 1000W Single Output Power Supply, Output Power Supply, Power Supply, Supply
SE-1000-12 MEAN WELL USA Inc. - РКС Компоненти - РАДІОМАГ
File Info : application/pdf, 3 Pages, 551.63KB
DocumentDocument1000W Single Output Power Supply SE-1000 series User's Manual https://www.meanwell.com/serviceGTIN.aspx SPECIFICATION UL62368-1 TPTC004 IEC62368-1 MODEL SE-1000-5 SE-1000-9 SE-1000-12 SE-1000-15 SE-1000-24 SE-1000-48 DC VOLTAGE 5V 9V 12V 15V 24V 48V RATED CURRENT 150A 100A 83.3A 66.7A 41.7A 20.8A CURRENT RANGE 0 ~ 150A 0 ~ 100A 0 ~ 83.3A 0 ~ 66.7A 0 ~ 41.7A 0 ~ 20.8A RATED POWER 750W 900W 999.6W 1000.5W 1000.8W 998.4W RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 200mVp-p OUTPUT VOLTAGE ADJ. RANGE 3.3 ~ 5.5V VOLTAGE TOLERANCE Note.3 ±1.0% LINE REGULATION ±0.5% LOAD REGULATION ±1.0% 7.5 ~ 10V ±1.0% ±0.5% ±0.5% 10 ~ 13.5V ±1.0% ±0.5% ±0.5% 13.5 ~ 16.5V ±1.0% ±0.5% ±0.5% 22 ~ 27.5V ±1.0% ±0.5% ±0.5% 43 ~ 56V ±1.0% ±0.5% ±0.5% SETUP, RISE TIME 1500ms, 50ms/230VAC 1500ms, 50ms/115VAC at full load HOLD UP TIME (Typ.) 20ms/230VAC 15ms/115VAC at full load VOLTAGE RANGE 90 ~ 132VAC / 180 ~ 264VAC selected by TB2 254 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz INPUT EFFICIENCY (Typ.) 81% 84% 85% 86% 88% 89% AC CURRENT (Typ.) 17.5A/115VAC 10A/230VAC INRUSH CURRENT (Typ.) 35A/115VAC 55A/230VAC LEAKAGE CURRENT <2.5mA / 240VAC OVERLOAD 105 ~ 125% rated output power Protection type : Shut down o/p voltage, re-power on to recover PROTECTION OVER VOLTAGE 5.75 ~ 6.75V 10.4 ~ 12.2V 13.8 ~ 16.2V 18 ~ 21V Protection type : Shut down o/p voltage, re-power on to recover 28 ~ 32.4V 57.6 ~ 67.2V OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down FUNCTION DC_OK SIGNAL REMOTE CONTROL WORKING TEMP. PSU turn on:3.3V ~ 5.6V PUS turn off:0 ~ 1V RC+/RC-: 0 ~ 0.8V power on; 4 ~ 10V power off -20 ~ +60 (Refer to "Derating Curve") WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT 20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH ±0.05%/ (0 ~ 50) VIBRATION SAFETY STANDARDS 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL62368-1, BSMI CNS15598-1, EAC TP TC 004 approved; Design refer to BS EN/EN62368-1 WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Parameter Standard Test Level / Note Conducted BS EN/EN55032 (CISPR32),CNS15936 Class A EMC EMISSION Radiated BS EN/EN55032 (CISPR32),CNS15936 Class A Harmonic Current BS EN/EN61000-3-2 ----- SAFETY & EMC (Note 4) Voltage Flicker BS EN/EN55035, BS EN/EN61000-6-2 Parameter BS EN/EN61000-3-3 Standard ----Test Level / Note ESD BS EN/EN61000-4-2 Level 3, 8KV air ; Level 2, 4KV contact Radiated BS EN/EN61000-4-3 Level 3 EMC IMMUNITY EFT / Burst Surge BS EN/EN61000-4-4 BS EN/EN61000-6-2 Level 3 2KV/Line-Line 4KV/Line-Earth Conducted BS EN/EN61000-4-6 Level 3 Magnetic Field BS EN/EN61000-4-8 Level 4 Voltage Dips and Interruptions BS EN/EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods MTBF 1273.6K hrs min. Telcordia SR-332 (Bellcore) ; 251.6K hrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 278*127*63.5mm (L*W*H) PACKING 2.5Kg; 6pcs/16Kg/1.38CUFT NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf) 5. By using UVP circuit, PSU will not turn on direct by in AC continue ON/OFF condition within 5 sec. 6. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). 7. This power supply does not meet the harmonic current requirements outlined by EN61000-3-2. Please do not use this power supply under the following conditions: a) the end-devices is used within the European Union, and b) the end-devices is connected to public mains supply with 220Vac or greater rated nominal voltage, and c) the power supply is: - installed in end-devices with average or continuous input power greater than 75W, or - belong to part of a lighting system Exception: Power supplies used within the following end-devices do not need to fulfill EN61000-3-2 a) professional equipment with a total rated input power greater than 1000W; b) symmetrically controlled heating elements with a rated power less than or equal to 200W Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx Downloaded from Arrow.com. File Name:SE-1000-SPEC 2024-05-20 9.25 11 1000W Single Output Power Supply SE-1000 series Mechanical Specification 19 max. 278 171.5 8-M4(Both Sides) 171.5 38 12.5 16 63.5 Case No. 935B Unit:mm 19 2-M4 8.5 39 max. 19 12.25 LED CN3 ADJ 6 1+ 4-M4 127 Air flow direction 1 2 3 1 2 TB1 TB2 101.5 OUTPUT +V -V TB1:AC input terminal Pin No. Assignment 1 AC/L 2 AC/N 3 FG TB2:110/220V Change Pin No. 110V 220V 1 2 Short Open Control Pin (CN3) : JST B6B-XH or equivalent Pin No. Assignment Pin No. Assignment 1 DC_OK Signal 4 +S 2 DC_OK GND 5 RC- 3 -S 6 RC+ Mating Housing JST XHP or equivalent Block Diagram I/P (TB1) EMI FILTER Derating Curve ACTIVE INRUSH CURRENT LIMITING 110/220V(TB2) RECTIFIERS POWER SWITCHING RECTIFIERS & FILTER O.V.P. O.L.P. O.T.P. PWM CONTROL FAN LOCK PROTECTION DETECTION CIRCUIT REMOTE CONTROL AUX FAN POWER Static Characteristics Terminal JST SXH-001T or equivalent fosc : 55KHz +S +V -V -S DC_OK RC 100 Others 80 5V,12V 60 50 40 20 -20 0 10 20 30 40 45 50 60 70 (HORIZONTAL) AMBIENT TEMPERATURE () 100 90 80 70 60 50 40 90 180 180 ~ 264VAC 90 ~ 132VAC 95 100 115 132 190 200 230 264 INPUT VOLTAGE (VAC) 60Hz File Name:SE-1000-SPEC 2024-05-20 LOAD (%) LOAD (%) Downloaded from Arrow.com. 1000W Single Output Power Supply Mechanical Specification DC_OK Signal DC_OK Signal is the voltage difference between "DC_OK" and "G" pin output DC_OK Signal is a TTL level signal PSU turn on: 3.3 ~ 5.6V PSU turn off: 0 ~ 1V +V RC+ RC- +S -S G DC OK CN3 ADJ + -V Remote Sensing G DC_OK LOAD -+ +V RC+ RC- +S -S G DC OK Remote Control Between RC+ and RC- Output SW OFF(0 ~ 0.8V) ON SW ON(4 ~ 10V) OFF CN3 ADJ + -V -S LOAD +S -+ +V RC+ RC- +S -S G DC OK CN3 ADJ + SW RC+ External Power Source I=6~20mA RC- Connector for remote Control -V LOAD -+ Downloaded from Arrow.com. SE-1000 series File Name:SE-1000-SPEC 2024-05-20