User Manual for KPS models including: DMM3000 Multifunctional Multimeter, DMM3000, Multifunctional Multimeter, Multimeter
Multimetru multifunctional, 10A, 1000V, KPS DMM3000
9 mag 2024 — •When using test leads or probes, keep your fingers behind the finger guards. •Remove test lead from Meter before opening the battery door or meter case.19 pagine
File Info : application/pdf, 19 Pages, 2.68MB
DocumentDocumentDMM3000 User Manual / MANUAL DEL USUARIO / Manuel d'utilisation / Benutzerhandbuch / Manuale Utente YEARS LIMITED WARRANTY EN All New True RMS Multimeter Multímetro de valor eficaz verdadero totalmente rediseñado Multimètre RMS (« valeurs efficaces vraies ») avec tout nouveau design Ganz neu gestaltetes True RMS Vielfachmessgerät IT Multimetro a vero valore efficace di progettazione assolutamente nuova DMM3000 EN ! Read First ! Safety Information Understand and follow operating instructions carefully. ! WARNING Identifies hazardous conditions and actions that could cause BODILY HARM or DEATH. ! CAUTION Identifies conditions and actions that could DAMAGE the meter or equipment under test. ! WARNING hWhen using test leads or probes, keep your fingers behind the finger guards. hRemove test lead from Meter before opening the battery door or meter case. hUse the Meter only as specified in this manual or the protection by the Meter might be impaired. hAlways use proper terminals, switch position, and range for measurements. hVerify the Meter's operation by measuring a known voltage. If in doubt, have the Meter serviced. hDo not apply more than the rated voltage, as marked on Meter, between terminals or between any terminal and earth ground. hOnly replace the blown fuse with the proper rating as specified in this manual. hUse caution with voltages above 30 Vac rms, 42 Vac peak,or 60 Vdc. These voltages pose a shock hazard. hTo avoid false readings that can lead to electric shock and injury, replace battery as soon as low battery indicator. hDisconnect circuit power and discharge all high-voltage capaci-tors before testing resistance, continuity, diodes, or capacitance. hDo not use Meter around explosive gas or vapor. hTo reduce the risk of fire or electric shock do not expose this product to rain or moisture. 1 DMM3000 EN ! CAUTION hDisconnect the test leads from the test points before changing the position of the function rotary switch. hDo not expose Meter to extremes in temperature or high humidity. h1HYHUVHWWKHPHWHULQ$IXQFWLRQWRPHDVXUHWKH voltage of a power supply circuit in equipment that could result in damage the meter and the equipment under test. Symbols as marked on the meter and Instruction manual Risk of electric shock ! See instruction manual DC measurement Equipment protected by double or reinforced insulation Battery Fuse Earth ~ AC measurement Conforms to EU directives Do not discard this product or throw away Attention! Magnets might affect the correct functioning of cardiac pacemakers and implanted defibrillators. As a user of such medical devices, keep a sufficient distance to the magnet. Unsafe Voltage To alert you to the presence of a potentially hazardous voltage, when the Tester detects a voltage Ú30 V or a voltage overload (OL) in V, mV, AutoV . The symbol is displayed. Maintenance Do not attempt to repair this Meter. It contains no user-serviceable parts. Repair or servicing should only be performed by qualified personnel. Cleaning Periodically wipe the case with a dry cloth and detergent. Do not use abrasives or solvents. 2 DMM3000 EN Introduction The Meter Description Front Panel Illustration 1. VoltSeek Light 2. 6,000 counts digital and 60 segments analog display 3. Push-buttons. 4. Rotary switch for turn the Power On / Off and select the function. 5. Input Terminal for Multi-function. 6. Input Terminal for A. 7. Common (Ground reference) Input Terminal. 1 VoltSeek Light 2 LCD Display 3 Button 4 Rotary Switch 5 V , , , lnput(or "+") 6 Common lnput 7 A lnput 3 DMM3000 EN Features : h6,000 count digital and 60 segments analog display hLarge white LED backlight display hTrue RMS measurements on ACV hLoZ for prevent false reading from ghost voltage hAutoVolt automatic AC/DC voltage selection hAuto Ranging h0.5% DCV accuracy hSmart Hold hPeak Hold for capture peak readings hRelative Function hAuto Power Off (can be disabled) hCapacitance measurements hFrequency Counter on ACV hDiode Test hFrequency Counter on ACA h10Amp ACA/DCA h11A/1000V High Energy Fuse hVoltSeekTM for non-contact voltage detection hEasyStickTM holster with built in magnetic sticker hContiVisionTM for visible continuity beeper hBattery Capacity indication in segments hIncluded Holster with Probe Holder, Tilt Stand and Magnetic sticker hCAT IV 600V/ CATIII 1000V standard Making Basic Measurements Preparation and Caution Before Measurement ! Observe the rules of ! Warnings and ! Cautions. ! CAUTION When connecting the test leads to the DUT (Device Under Test) connect the common test leads before connecting the live test leads ; when removing the test leads, remove the live test leads before removing the common test leads. 4 DMM3000 EN Measuring ACV/DCV/AutoV Voltage Dial the switch to select the measuring function. Measuring AC/DC Current Disconnect Dial the switch to select the measuring function. 5 DMM3000 EN Measuring Capacitance / Diode Dial the switch and press the Function button to select the measuring function Measuring Continuity / Resistance Red Black Dial the switch and press the Function button to select the measuring function. 6 DMM3000 EN VoltSeek Dial the switch and press the RANGE button to select the measuring function and sensitivity. ! WARNING The VoltSeek LED indicates the electric field. If the VoltSeek LED is not on, voltage could still be present. Using the Function Switch Position Function Press the Function button to change the function on the same switch position. 7 DMM3000 Range Button 1 2 EN 3 Press Ragen Button >2 Sec to Auto Mode 1 Peak Hold (for AC only) Press Button > 2 sec Leave the peak hold mode In the Peak Hold function ,the meter records the peak min. value and the peak max. value when the inputs goes below the recorded peak min. value or above the recorded peak max. value ,the meter records the new value . Press Hold button to pause the recording. 8 DMM3000 EN Smart Hold The meter will beep continuously and the display will flash if the measured signal is larger than the display reading by 50 counts. (However ,it can not detect across the AC and DC Voltage / Current). 5HODWLYH Press the Relative button to enable/disenable this function. Backlight Press the Backlight button to turn the backlight on/off. 9 DMM3000 EN Auto Power Off Wake-up the meter by dialing the switch or pressing any button. Disable Auto Power Off Dial the switch to off position ,then keep the Function button down and turn the meter on. 10 DMM3000 EN Testing LCD Monitor Dial the switch to off position ,then keep the HOLD button down and turn the meter on. Fuse Replacement Fuse:11A/1000V 11 DMM3000 EN Low Battery and Battery Replacement Replace the battery as soon as the low battery indicator appears, to avoid false reading. Refer to the following figure to replace the batteries ! CAUTION Remove test leads from meter before opening the battery cover or meter case. 12 DMM3000 EN Specifications General Specifications Maximum voltage applied to any terminal : 1000 Vac rms or 1000 Vdc. rms Display : 6000 counts. Polarity Indication : Automatic, positive implied, negative indicated. Overrange Indication : OL Batteries Life : 200 hours ALKALINE Battery Low Batteries Indication : Voltage drops below operating voltage will flash. Power Requirement : 9V battery Auto Power Off : 20 minutes. Operating Temperature : -10 ~10°C 10°C ~ 30°C (Ù80% RH), 30°C ~ 40°C (Ù75% RH), 40°C ~ 50°C (Ù45%RH) Storage Temperature : -40°C to 60°C , 0 to 80% R.H. (batteries not fitted) Measure : Samples 3 times per second . Altitude : 6561.7 ft (2000m) CAT Application field The circuits not connected to mains. The circuits directly connected to Low-voltage installation. The building installation. The source of the Low-voltage installation. Weight : 250g (including battery) Dimensions (W x H x D) : 74mm x 156mm x 44mm. Pollution degree : 2 Safety : Complies with EN61010-1,CAT.IV. 600V, CAT.. 1000V EMC : EN 61326-1 Shock vibration : Sinusoidal vibration per MIL-PRF- 28800F (5 ~ 55 Hz, 3g max.) Drop Protection : 4 feet drop to hardwood on concrete floor. Indoor Use. 13 DMM3000 EN Electrical Specifications Accuracy is given as ±(% of reading + counts of least significant digit) at 23°C ± 5°C, with relative humidity Less than 80% R.H. 1. Temperature coefficient 0.1 x (Specified accuracy) / °C, < 18°C, > 28°C 2. AC Function ACV and ACA specifications are ac coupled, true R.M.S. The crest factor may be up to 3.0 as 4000 counts. For square wave, Accuracy is unspecified. For non-sinusoidal waveforms, Additional Accuracy by Crest Factor (C.F.) : Add 3.0% for C.F. 1.0 ~ 2.0. Add 5.0% for C.F. 2.0 ~ 2.5. Add 7.0% for C.F. 2.5 ~ 3.0. 3. DC mV Range 600.0mV OL Reading 660.0mV Resolution 0.1mV Accuracy ±(0.5% + 5D) Input Impedance :0 Overload Protection : AC/DC1000V 4. DC Voltage Range 6.000V 60.00V 600.0V 1000V OL Reading 6.600V 66.00V 660.0V 1100V Resolution 0.001V 0.01V 0.1V 1V Accuracy ±(0.5% + 2D) Input Impedance : 0 Overload Protection : AC/DC 1000V 14 DMM3000 EN 5. AC Voltage Range 600.0mV 6.000V 60.00V 600.0V 1000V OL Reading 660.0mV 6.600V 66.00V 660.0V 1100V Resolution 0.1mV 0.001V 0.01V 0.1V 1V Accuracy ±(1.0% + 5D) ±(1.0% + 3D) LCD displays 0 counts when the reading < 10 counts. Input Impedance: 0OHVVWKDQS) Frequency Response: 45~500Hz(Sine Wave) Overload Protection: AC/DC 1000V 6. Auto Voltage Range 600.0V 1000V OL Reading 660.0V 1100V Resolution 0.1V 1V Accuracy ±(2.0% + 3D) LCD displays 0 counts when the reading < 10 counts. Input Impedance : OHVVWKDQN Frequency Response : 45 ~ 500Hz (Sine Wave) Overload Protection : AC/DC 1000V 7. DC Current Range 6.000A 10.00A OL Reading 6.600A 20.00A Resolution 0.001A 0.01A Accuracy ±(1.0% + 3D) Maximum measurement time : >5A for max.3 minutes with at least 20 minutes rest time. >10A for max.30 seconds with at least 10 minutes rest time. Overload Protection : AC/DC 11A 15 DMM3000 EN 8. AC Current Range 6.000A 10.00A OL Reading 6.600A 20.00A Resolution 0.001A 0.01A Accuracy ±(1.5% + 3D) In 6A Range,LCD displays 0 counts when the reading < 20 counts. In10A Range,LCD displays 0 counts when the reading < 10 counts. Maximum measurement time : >5A for max.3 minutes with at least 20 minutes rest time. >10A for max.30 seconds with at least 10 minutes rest time. Frequency Response : 45 ~ 500Hz (Sine Wave) Overload Protection : AC/DC 11A 9. Resistance Range N N N 0 0 OL Reading N N N 0 0 Resolution N N N 0 0 Accuracy ±(0.9% + 5D) ±(0.9% + 2D) ±(0.9% + 2D) ±(0.9% + 2D) ±(0.9% + 2D) ±(1.5% + 5D) 7KHUHLVDOLWWOHUROOLQJOHVVWKDQGLJLWVZKHQPHDVXULQJ! 0 Overload Protection : AC/DC 1000V 10. Continuity Range OL Reading Resolution Accuracy ±(0.9% + 5D) Continuity : Built-in buzzer sounds when measured resistance is OHVVWKDQDQGVRXQGVRIIZKHQPHDVXUHGUHVLVWDQFHLVPRUH WKDQ%HWZHHQWRWKHEX]]HUPD\EHVRXQGRURII either. Continuity Indicator : 2KHz Tone Buzzer Response Time of Buzzer : VHF Overload Protection : AC/DC 1000V 16 DMM3000 EN 11. Diode Range 1.500V OL Reading 1.550V Resolution 0.001V Open Circuit Voltage : Approx. 1.8V Overload Protection : AC/DC 1000V. Accuracy ±(0.9% + 2D) 12. Capacitance Range 1.000F 10.00F 100.0F 1.000mF 10.00mF OL Reading 1.100F 11.00F 110.0F 1.100mF 11.00mF Resolution 0.001F 0.01F 0.1F 0.001mF 0.01mF Overload Protection : AC/DC 1000V. Accuracy ±(1.9% + 5D) ±(1.9% + 2D) 13. Frequency Range 100.00Hz 1000.0Hz 10.000kHz 100.00kHz OL Reading 100.00Hz 1000.0Hz 10.000kHz 100.00kHz Resolution 0.01Hz 0.1Hz 0.001kHz 0.01kHz Accuracy ±(0.1% + 2D) Minimum Sensitivity : > 5V (for ACV 1Hz ~ 10kHz) > 20.0V (for ACV 10kHz ~ 50kHz) unspecified (for ACV 50kHz ~ 100kHz) >0.6A (for ACA) Minimum Frequency : 1Hz Overload Protection : AC/DC 1000V or 11A 14. Peak Hold Specified accuracy ± 150 digits. Accuracy of Square Wave is unspecified. 15. VoltSeek Voltage Range of High Sensitivity : 80V ~ 1000V (At the top edge of the meter) Voltage Range of Low Sensitivity : 160V ~ 1000V (At the top edge of the meter) 17 DMM3000 EN Limited Warranty This meter is warranted to the original purchaser against defects in material and workmanship for 2 years from the date of purchase. During this warranty period, Manufacturer will, at its option, replace or repair the defective unit, subject to verification of the defect or malfunction. This warranty does not cover fuses, disposable batteries, or damage from abuse, neglect, accident, unauthorized repair, alteration, contamination, or abnormal conditions of operation or handling. Any implied warranties arising out of the sale of this product, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the above. The manufacturer shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expense or economic loss. Some states or countries laws vary, so the above limitations or exclusions may not apply to you. 18iLovePDF