User Manual for KPS models including: DMM3000 Multifunctional Multimeter, DMM3000, Multifunctional Multimeter, Multimeter

AICI

Multimetru multifunctional, 10A, 1000V, KPS DMM3000

DMM3000

9 mag 2024 — •When using test leads or probes, keep your fingers behind the finger guards. •Remove test lead from Meter before opening the battery door or meter case.19 pagine

[PDF] DMM3000 - Bitmi.rowww.bitmi.ro › bitmi.ro › files › files


File Info : application/pdf, 19 Pages, 2.68MB

PDF preview unavailable. Download the PDF instead.

user-manual-kps-dmm3000-1-19-4208
DMM3000
User Manual / MANUAL DEL USUARIO / Manuel d'utilisation / Benutzerhandbuch / Manuale Utente
YEARS
LIMITED WARRANTY
EN All New True RMS Multimeter Multímetro de valor eficaz verdadero totalmente rediseñado Multimètre RMS (« valeurs efficaces vraies ») avec tout nouveau design Ganz neu gestaltetes True RMS Vielfachmessgerät
IT Multimetro a vero valore efficace di progettazione assolutamente nuova

DMM3000

EN

! Read First
! Safety Information
Understand and follow operating instructions carefully.
! WARNING
Identifies hazardous conditions and actions that could cause BODILY HARM or DEATH.
! CAUTION
Identifies conditions and actions that could DAMAGE the meter or equipment under test.
! WARNING
hWhen using test leads or probes, keep your fingers behind the finger guards.
hRemove test lead from Meter before opening the battery door or meter case.
hUse the Meter only as specified in this manual or the protection by the Meter might be impaired.
hAlways use proper terminals, switch position, and range for measurements.
hVerify the Meter's operation by measuring a known voltage. If in doubt, have the Meter serviced.
hDo not apply more than the rated voltage, as marked on Meter, between terminals or between any terminal and earth ground.
hOnly replace the blown fuse with the proper rating as specified in this manual.
hUse caution with voltages above 30 Vac rms, 42 Vac peak,or 60 Vdc. These voltages pose a shock hazard.
hTo avoid false readings that can lead to electric shock and injury, replace battery as soon as low battery indicator.
hDisconnect circuit power and discharge all high-voltage capaci-tors before testing resistance, continuity, diodes, or capacitance.
hDo not use Meter around explosive gas or vapor. hTo reduce the risk of fire or electric shock do not expose this
product to rain or moisture.

1

DMM3000

EN

! CAUTION
hDisconnect the test leads from the test points before changing the position of the function rotary switch.
hDo not expose Meter to extremes in temperature or high humidity. h1HYHUVHWWKHPHWHULQ$IXQFWLRQWRPHDVXUHWKH
voltage of a power supply circuit in equipment that could result in damage the meter and the equipment under test.

Symbols as marked on the meter and Instruction manual
Risk of electric shock
! See instruction manual DC measurement
Equipment protected by double or reinforced insulation
Battery
Fuse
Earth
~ AC measurement
Conforms to EU directives
Do not discard this product or throw away
Attention! Magnets might affect the correct functioning of cardiac pacemakers and implanted defibrillators. As a user of such medical devices, keep a sufficient distance to the magnet.

Unsafe Voltage
To alert you to the presence of a potentially hazardous voltage, when the Tester detects a voltage Ú30 V or a voltage overload (OL) in V, mV, AutoV . The symbol is displayed.
Maintenance
Do not attempt to repair this Meter. It contains no user-serviceable parts. Repair or servicing should only be performed by qualified personnel.
Cleaning
Periodically wipe the case with a dry cloth and detergent. Do not use abrasives or solvents.
2

DMM3000

EN

Introduction
The Meter Description Front Panel Illustration 1. VoltSeek Light 2. 6,000 counts digital and 60 segments analog display 3. Push-buttons. 4. Rotary switch for turn the Power On / Off and select the
function. 5. Input Terminal for Multi-function. 6. Input Terminal for A. 7. Common (Ground reference) Input Terminal.

1 VoltSeek Light 2 LCD Display 3 Button
4 Rotary Switch
5 V , , , lnput(or "+") 6 Common lnput 7 A lnput

3

DMM3000

EN

Features :
h6,000 count digital and 60 segments analog display hLarge white LED backlight display hTrue RMS measurements on ACV hLoZ for prevent false reading from ghost voltage hAutoVolt automatic AC/DC voltage selection hAuto Ranging h0.5% DCV accuracy hSmart Hold hPeak Hold for capture peak readings hRelative Function hAuto Power Off (can be disabled) hCapacitance measurements hFrequency Counter on ACV hDiode Test hFrequency Counter on ACA h10Amp ACA/DCA h11A/1000V High Energy Fuse hVoltSeekTM for non-contact voltage detection hEasyStickTM holster with built in magnetic sticker hContiVisionTM for visible continuity beeper hBattery Capacity indication in segments hIncluded Holster with Probe Holder, Tilt Stand and Magnetic
sticker hCAT IV 600V/ CATIII 1000V standard

Making Basic Measurements
Preparation and Caution Before Measurement ! Observe the rules of ! Warnings and ! Cautions.
! CAUTION
When connecting the test leads to the DUT (Device Under Test) connect the common test leads before connecting the live test leads ; when removing the test leads, remove the live test leads before removing the common test leads.

4

DMM3000

EN

Measuring ACV/DCV/AutoV Voltage

Dial the switch to select the measuring function.
Measuring AC/DC Current
Disconnect
Dial the switch to select the measuring function.
5

DMM3000

EN

Measuring Capacitance / Diode

Dial the switch and press the Function button to select the measuring function
Measuring Continuity / Resistance

Red

Black

Dial the switch and press the Function button to select the measuring function.
6

DMM3000

EN

VoltSeek

Dial the switch and press the RANGE button to select the measuring function and sensitivity.
! WARNING
The VoltSeek LED indicates the electric field. If the VoltSeek LED is not on, voltage could still be present.

Using the Function
Switch Position

Function

Press the Function button to change the function on the same switch position.
7

DMM3000

Range Button

1

2

EN
3

Press Ragen Button >2 Sec to Auto Mode 1
Peak Hold (for AC only)

Press

Button > 2 sec

Leave the peak hold mode

In the Peak Hold function ,the meter records the peak min. value and the peak max. value when the inputs goes below the recorded peak min. value or above the recorded peak max. value ,the meter records the new value . Press Hold button to pause the recording.

8

DMM3000

EN

Smart Hold

The meter will beep continuously and the display will flash if the measured signal is larger than the display reading by 50 counts. (However ,it can not detect across the AC and DC Voltage / Current).
5HODWLYH
Press the Relative button to enable/disenable this function.
Backlight
Press the Backlight button to turn the backlight on/off.
9

DMM3000

EN

Auto Power Off

Wake-up the meter by dialing the switch or pressing any button.
Disable Auto Power Off

Dial the switch to off position ,then keep the Function button down and turn the meter on.
10

DMM3000

EN

Testing LCD Monitor

Dial the switch to off position ,then keep the HOLD button down and turn the meter on.
Fuse Replacement

Fuse:11A/1000V
11

DMM3000

EN

Low Battery and Battery Replacement
Replace the battery as soon as the low battery indicator appears, to avoid false reading. Refer to the following figure to replace the batteries

! CAUTION
Remove test leads from meter before opening the battery cover or meter case.
12

DMM3000

EN

Specifications
General Specifications
Maximum voltage applied to any terminal : 1000 Vac rms or 1000 Vdc. rms Display : 6000 counts. Polarity Indication : Automatic, positive implied, negative
indicated. Overrange Indication : OL Batteries Life : 200 hours ALKALINE Battery Low Batteries Indication : Voltage drops below operating voltage will flash. Power Requirement : 9V battery Auto Power Off : 20 minutes. Operating Temperature : -10 ~10°C
10°C ~ 30°C (Ù80% RH), 30°C ~ 40°C (Ù75% RH), 40°C ~ 50°C (Ù45%RH) Storage Temperature : -40°C to 60°C , 0 to 80% R.H. (batteries not fitted) Measure : Samples 3 times per second . Altitude : 6561.7 ft (2000m)

CAT

Application field

 The circuits not connected to mains.

 The circuits directly connected to Low-voltage installation.

 The building installation.  The source of the Low-voltage installation.

Weight : 250g (including battery)
Dimensions (W x H x D) : 74mm x 156mm x 44mm.
Pollution degree : 2 Safety : Complies with EN61010-1,CAT.IV. 600V, CAT.. 1000V EMC : EN 61326-1 Shock vibration : Sinusoidal vibration per MIL-PRF- 28800F (5 ~ 55 Hz, 3g max.) Drop Protection : 4 feet drop to hardwood on concrete floor. Indoor Use.

13

DMM3000

EN

Electrical Specifications
Accuracy is given as ±(% of reading + counts of least significant digit) at 23°C ± 5°C, with relative humidity Less than 80% R.H.
1. Temperature coefficient 0.1 x (Specified accuracy) / °C, < 18°C, > 28°C
2. AC Function ACV and ACA specifications are ac coupled, true R.M.S. The crest factor may be up to 3.0 as 4000 counts. For square wave, Accuracy is unspecified. For non-sinusoidal waveforms, Additional Accuracy by Crest Factor (C.F.) : Add 3.0% for C.F. 1.0 ~ 2.0.
Add 5.0% for C.F. 2.0 ~ 2.5. Add 7.0% for C.F. 2.5 ~ 3.0.

3. DC mV Range 600.0mV

OL Reading 660.0mV

Resolution 0.1mV

Accuracy ±(0.5% + 5D)

Input Impedance :0 Overload Protection : AC/DC1000V

4. DC Voltage

Range 6.000V 60.00V 600.0V 1000V

OL Reading 6.600V 66.00V 660.0V 1100V

Resolution 0.001V 0.01V 0.1V 1V

Accuracy ±(0.5% + 2D)

Input Impedance : 0 Overload Protection : AC/DC 1000V

14

DMM3000

EN

5. AC Voltage

Range 600.0mV 6.000V 60.00V 600.0V
1000V

OL Reading 660.0mV 6.600V 66.00V 660.0V 1100V

Resolution 0.1mV 0.001V 0.01V 0.1V 1V

Accuracy ±(1.0% + 5D)
±(1.0% + 3D)

LCD displays 0 counts when the reading < 10 counts. Input Impedance: 0OHVVWKDQS) Frequency Response: 45~500Hz(Sine Wave) Overload Protection: AC/DC 1000V

6. Auto Voltage

Range 600.0V 1000V

OL Reading 660.0V 1100V

Resolution 0.1V 1V

Accuracy ±(2.0% + 3D)

LCD displays 0 counts when the reading < 10 counts. Input Impedance : OHVVWKDQN Frequency Response : 45 ~ 500Hz (Sine Wave) Overload Protection : AC/DC 1000V

7. DC Current

Range 6.000A 10.00A

OL Reading 6.600A 20.00A

Resolution 0.001A 0.01A

Accuracy ±(1.0% + 3D)

Maximum measurement time : >5A for max.3 minutes with at least 20 minutes rest time. >10A for max.30 seconds with at least 10 minutes rest time. Overload Protection : AC/DC 11A

15

DMM3000

EN

8. AC Current Range 6.000A 10.00A

OL Reading 6.600A 20.00A

Resolution 0.001A 0.01A

Accuracy ±(1.5% + 3D)

In 6A Range,LCD displays 0 counts when the reading < 20 counts. In10A Range,LCD displays 0 counts when the reading < 10 counts. Maximum measurement time : >5A for max.3 minutes with at least 20 minutes rest time. >10A for max.30 seconds with at least 10 minutes rest time. Frequency Response : 45 ~ 500Hz (Sine Wave) Overload Protection : AC/DC 11A

9. Resistance
Range  N N N 0 0

OL Reading  N N N 0 0

Resolution 
N N N 0 0

Accuracy ±(0.9% + 5D) ±(0.9% + 2D) ±(0.9% + 2D) ±(0.9% + 2D) ±(0.9% + 2D) ±(1.5% + 5D)


7KHUHLVDOLWWOHUROOLQJOHVVWKDQGLJLWVZKHQPHDVXULQJ! 0 Overload Protection : AC/DC 1000V

10. Continuity

Range 

OL Reading 

Resolution 

Accuracy ±(0.9% + 5D)

Continuity : Built-in buzzer sounds when measured resistance is OHVVWKDQDQGVRXQGVRIIZKHQPHDVXUHGUHVLVWDQFHLVPRUH WKDQ%HWZHHQWRWKHEX]]HUPD\EHVRXQGRURII either.
Continuity Indicator : 2KHz Tone Buzzer Response Time of Buzzer : VHF Overload Protection : AC/DC 1000V

16

DMM3000

EN

11. Diode

Range 1.500V

OL Reading 1.550V

Resolution 0.001V

Open Circuit Voltage : Approx. 1.8V Overload Protection : AC/DC 1000V.

Accuracy ±(0.9% + 2D)

12. Capacitance

Range 1.000F 10.00F 100.0F 1.000mF 10.00mF

OL Reading 1.100F 11.00F 110.0F 1.100mF 11.00mF

Resolution 0.001F 0.01F
0.1F 0.001mF 0.01mF

Overload Protection : AC/DC 1000V.

Accuracy ±(1.9% + 5D)
±(1.9% + 2D)

13. Frequency

Range 100.00Hz 1000.0Hz 10.000kHz 100.00kHz

OL Reading 100.00Hz 1000.0Hz 10.000kHz 100.00kHz

Resolution 0.01Hz 0.1Hz
0.001kHz 0.01kHz

Accuracy ±(0.1% + 2D)

Minimum Sensitivity : > 5V (for ACV 1Hz ~ 10kHz) > 20.0V (for ACV 10kHz ~ 50kHz) unspecified (for ACV 50kHz ~ 100kHz) >0.6A (for ACA) Minimum Frequency : 1Hz Overload Protection : AC/DC 1000V or 11A

14. Peak Hold Specified accuracy ± 150 digits. Accuracy of Square Wave is unspecified.

15. VoltSeek Voltage Range of High Sensitivity : 80V ~ 1000V (At the top edge of the meter) Voltage Range of Low Sensitivity : 160V ~ 1000V (At the top edge of the meter)
17

DMM3000

EN

Limited Warranty

This meter is warranted to the original purchaser against defects in material and workmanship for 2 years from the date of purchase. During this warranty period, Manufacturer will, at its option, replace or repair the defective unit, subject to verification of the defect or malfunction. This warranty does not cover fuses, disposable batteries, or damage from abuse, neglect, accident, unauthorized repair, alteration, contamination, or abnormal conditions of operation or handling. Any implied warranties arising out of the sale of this product, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the above. The manufacturer shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expense or economic loss. Some states or countries laws vary, so the above limitations or exclusions may not apply to you.

18

