User Guide for mPower Electronics models including: MP883 Dual Channel VOXI Controller, MP883, Dual Channel VOXI Controller, Channel VOXI Controller, VOXI Controller, Controller
17 hours ago — The VOXI Controller full User's Guide must be carefully read by all ... Quick Start Guide. PN: M028-4010-000 v1.0. mPower Electronics Inc. 2910 Scott ...
VOXiWatch II Workover Rig Monitoring System | mPower Electronics Inc.
File Info : application/pdf, 3 Pages, 419.54KB
DocumentDocumentVOXI Controller MP883 Dual Channel Quick Start Guide mPower Electronics Inc. 2910 Scott Blvd. Santa Clara, CA 95054 www.mpowerinc.com info@mpowerinc.com Read Before Operating The VOXI Controller full User's Guide must be carefully read by all individuals who have the responsibility of using, maintaining, or servicing this product. The product will perform as designed only if it is used, maintained, and serviced in accordance with the manufacturer's instructions. Warnings · The MP883 Controller is NOT certified for use in hazardous gas locations. VOXI gas transmitters in hazardous locations may be connected to it with appropriate cabling. · Never operate the Controller when the cover is removed. · Remove the Controller cover only in a non-hazardous area. · Use only mPower's sensors and accessories. Substitution of components will impair intrinsic safety and void warranty. Mounting Using the four mounting feet and attach to any solid surface in a non-hazardous-gas location. The VOXI transmitters may be mounted in hazardous locations with appropriate cabling connecting to the MP883 Controller outside the hazardous area. PN: M028-4010-000 v1.0 User Interface The MP883 is a remote controller, display and alarm for one or two VOXI transmitters. The user interface has an LCD graphic display, LED indications and 4 pushbuttons for programming. 1 Wiring Connections Relay Board 4-20 mA Channels and RS-485 Modbus Relay Board Alarms & Relay Output/Load 2 3 SD Card A user-provided 32GB SD card can optionally be used to log events such as power on/off, calibration, alarms, and faults. Insert the card in the slot on the back side of the main circuit board. If no SD card is present, the Channel 2 LED will show solid red during the 60-sec power on warmup period. Data can be downloaded on a PC using mPower Suite. Start Up Display Operating Display When the startup is complete, the gas concentrations are displayed. If any alarm level is exceeded, the Channel LED flashes and the display backlight changes color. Battery A CR2032 3V button cell battery is used to back up the real time clock in case main power is lost. Start Up Once 12-24V power is connected, the MP883 Controller enters a 60-sec warm up while various functions are tested, and parameters displayed. 4 5 Operating Display (continued) The operating displays include: Condition Panel Backlight LED Normal Green Green Steady Low Alarm Orange Yellow Flashing High Alarm Red Red Flashing High High Alarm Red Red Flashing Sensor Warm Up Light Blue Blue Steady Cal in Progress Light Blue Blue Steady No Signal Dark Blue Blue Flashing Sensor Fault Dark Blue Blue Flashing Programming (continued) · Main (Setup) Menu The Setup Menu has 4 items Channel 1, Channel 2, Device and Password. Alarm Test Press Test for 5 seconds to test alarm/relay functions. Programming · Enter Setup Menu Press and hold the Escape button for 5 seconds and enter the password (if activated). The default is 0000. · Navigating Menus · Up & Down keys move the cursor or increase & decrease numbers in editing mode (underline). · Enter enters a sub-menu, enters/exits editing mode, or saves a change. · Escape exits the sub-menu or main menu. 6 7 Programming (continued) · Sub-Menus The sub-menus are listed below Channel 1 or Channel 2 Configure Function Name Channel name Gas Gas name Measure Gas unit Span Span value Decimals # of decimal point displayed Enabled Enable/disable channel Alarm 1, 2 or 3 Sub-Menu Enabled Set Point Low Trip Latching Strobe Horn Relay1 Relay2 Function Enable/disable alarm Set trigger value Trigger above or below Latching or no latching alarm Activate strobe light Activate horn Activate relay 1 Activate relay 2 8 Programming (continued) Channel 1 or Channel 2 Calibration Function Reading Current reading Gain Channel gain adjustment Offset Channel offset adjustment Clock Date Time Modbus Baud Fault Relay Fail Safe Serial Number Serial Number Device Function Change date Change time Function Baud rate Function Yes or No Function View serial number Password Lock Password Password Function Need protection or not Change password 9