VOXIWatch MP883 Controller Quick Start Guide v1.0

VOXiWatch II Workover Rig Monitoring System | mPower Electronics Inc.


File Info : application/pdf, 3 Pages, 419.54KB

PDF preview unavailable. Download the PDF instead.

MP883-VOXiWatch-Controller-Engl-QSG-V1.0
VOXI Controller
MP883 Dual Channel Quick Start Guide
mPower Electronics Inc. 2910 Scott Blvd. Santa Clara, CA 95054
www.mpowerinc.com info@mpowerinc.com

Read Before Operating The VOXI Controller full User's Guide must be carefully read by all individuals who have the responsibility of using, maintaining, or servicing this product. The product will perform as designed only if it is used, maintained, and serviced in accordance with the manufacturer's instructions.
Warnings
· The MP883 Controller is NOT certified for use in hazardous gas locations. VOXI gas transmitters in hazardous locations may be connected to it with appropriate cabling.
· Never operate the Controller when the cover is removed. · Remove the Controller cover only in a non-hazardous area. · Use only mPower's sensors and accessories. Substitution of
components will impair intrinsic safety and void warranty.
Mounting Using the four mounting feet and attach to any solid surface in a non-hazardous-gas location. The VOXI transmitters may be mounted in hazardous locations with appropriate cabling connecting to the MP883 Controller outside the hazardous area.

PN: M028-4010-000

v1.0

User Interface The MP883 is a remote controller, display and alarm for one or two VOXI transmitters. The user interface has an LCD graphic display, LED indications and 4 pushbuttons for programming.

1
Wiring Connections Relay Board 4-20 mA Channels and RS-485 Modbus

Relay Board Alarms & Relay Output/Load

2

3

SD Card A user-provided 32GB SD card can optionally be used to log events such as power on/off, calibration, alarms, and faults. Insert the card in the slot on the back side of the main circuit board. If no SD card is present, the Channel 2 LED will show solid red during the 60-sec power on warmup period. Data can be downloaded on a PC using mPower Suite.

Start Up Display

Operating Display When the startup is complete, the gas concentrations are displayed. If any alarm level is exceeded, the Channel LED flashes and the display backlight changes color.

Battery A CR2032 3V button cell battery is used to back up the real time clock in case main power is lost.

Start Up

Once 12-24V power is connected, the MP883

Controller enters a 60-sec warm up while various

functions are tested, and parameters displayed.

4

5

Operating Display (continued)

The operating displays include:

Condition Panel Backlight

LED

Normal

Green

Green Steady

Low Alarm

Orange Yellow Flashing

High Alarm

Red

Red Flashing

High High Alarm

Red

Red Flashing

Sensor Warm Up Light Blue

Blue Steady

Cal in Progress Light Blue

Blue Steady

No Signal

Dark Blue Blue Flashing

Sensor Fault

Dark Blue Blue Flashing

Programming (continued) · Main (Setup) Menu
The Setup Menu has 4 items ­ Channel 1, Channel 2, Device and Password.

Alarm Test Press Test for 5 seconds to test alarm/relay functions.

Programming

· Enter Setup Menu

Press and hold the Escape button for 5 seconds and

enter the password (if activated). The default is 0000.

· Navigating Menus

· Up & Down keys move the cursor or increase &

decrease numbers in editing mode (underline).

· Enter enters a sub-menu, enters/exits editing mode,

or saves a change.

· Escape exits the sub-menu or main menu.

6

7

Programming (continued)

· Sub-Menus

The sub-menus are listed below

Channel 1 or Channel 2

Configure

Function

Name

Channel name

Gas

Gas name

Measure

Gas unit

Span

Span value

Decimals

# of decimal point displayed

Enabled

Enable/disable channel

Alarm 1, 2 or 3 Sub-Menu Enabled Set Point Low Trip Latching Strobe Horn Relay1 Relay2

Function
Enable/disable alarm Set trigger value
Trigger above or below Latching or no latching alarm
Activate strobe light Activate horn Activate relay 1 Activate relay 2

8

Programming (continued)

Channel 1 or Channel 2

Calibration

Function

Reading

Current reading

Gain

Channel gain adjustment

Offset

Channel offset adjustment

Clock Date Time
Modbus Baud
Fault Relay Fail Safe
Serial Number Serial Number

Device Function
Change date Change time
Function Baud rate
Function Yes or No
Function View serial number

Password Lock
Password

Password Function
Need protection or not Change password

9

