Instruction Manual for solarMD models including: SS4074-11, Advanced Lithium-Ion Battery, Lithium-Ion Battery, Advanced Battery, SS4074-11, Battery
SUPPORT | Solar MD
SS4074 Wall Mount Overview | Solar MD
File Info : application/pdf, 22 Pages, 9.62MB
DocumentDocumentSolar MD (PTY) ltd. Unit 23, Alternator Park Montague Gardens 7441 Cape Town, South Africa INSTALLATION MANUAL SS4074-11 Advanced Lithium-Ion battery Unit 23, Alternator Park Montague Gardens 7441 Cape Town, South Africa Solar MD (PTY) ltd. E: info@solarmd.co.za T: (021) 555 2181. SS4074-11 INSTALLATION MANUAL v1.0 Introduction 2 Product Description 2 Product Specifications 2 Errors or Inaccuracies 2 Copyrights 3 Safety Information 3 Warnings Cautions 3 Specification 4 Mechanical installation 5 Installing bottom cover plate 6 Electrical installation 7 Commissioning 9 Multicolor multipurpose button 10 Button function 10 Button indication 11 BMS Warnings and Errors 12 CANBUS connection. 18 CANBUS warnings. 19 Troubleshooting Warnings / Errors 20 Maximum charging / discharging voltages for non supported devices. 21 1 Unit 23, Alternator Park Montague Gardens 7441 Cape Town, South Africa Solar MD (PTY) ltd. E: info@solarmd.co.za T: (021) 555 2181. SS4074-11 INSTALLATION MANUAL v1.0 Introduction This manual is intended to provide assistance to an installer for the installation and commissioning of the range of Solar MD Lithium Ion phosphate (LiFePO4) energy storage solutions. Product Description The SS4074-11 battery solution is available in one standard size and can be paralleled to meet most residential applications. The rated voltage is 51.2V nominal (to suit 48V systems). Larger systems are provided by Solar MD based on specific project requirements. WARNING: Read the entire document before installing or using the Solar MD battery. Failure to comply with the instructions or warnings in this document could result in electrical shock or serious injury that can result in death or damage to the product that can render the SS4074 Solar MD battery inoperable. 2 Unit 23, Alternator Park Montague Gardens 7441 Cape Town, South Africa Solar MD (PTY) ltd. E: info@solarmd.co.za T: (021) 555 2181. SS4074-11 INSTALLATION MANUAL v1.0 Product Specifications All SS4074-11 specifications & descriptions contained in this document are verified to be accurate at the time of printing. Solar MD reserves the right to make any product revisions & improvements at any time. Errors or Inaccuracies To communicate any inaccuracies, omissions or to provide general feedback regarding this manual, send an email to info@solarmd.co.za Copyrights All information in this document is subject to the copyright of Solar MD (Pty) Ltd. Additional information is available upon request. Safety Information This manual contains important instructions and warnings that must be followed when using SS4074-11. Read all instructions before installing and using the SS4074-11. Warnings Cautions Use SS4074-11 only as instructed. For communication and other information please read the BMS manual. Do not attempt to disassemble, repair, modify, or tamper with this battery unit. Do not insert foreign objects into any part of battery unit. Avoid exposure to any moisture. Do not expose to extreme temperatures. Do not drill any holes into the box. Use only an approved Solar MD installer to install this product. Failure to comply will void the warranty 3 Unit 23, Alternator Park Montague Gardens 7441 Cape Town, South Africa Solar MD (PTY) ltd. E: info@solarmd.co.za T: (021) 555 2181. SS4074-11 INSTALLATION MANUAL v1.0 Specification Battery type Battery module Solar MD 7.4kWh SS4074-11 specification Lithium Iron Phosphate SS4074 Scalability Communication Yes CANBUS 500kbps / CAN 2.0B Rated battery capacity 7373 Wh Can BUS termination Single 120 Ohm Output power Max 5 kW Canbus id range: 256 - 499 Usable battery energy @ 0.3 7.37 kWh Nominal voltage 51.2V Protection method Protection phy Cell level: uv / ov / oc Position: x / y / x Acceleration: x / y / z Temperature: ot / ut Mechanical relay NO Rated Current (Ampere) 100A C Rating 0.69C Number of battery modules 1 module Com (CANBUS ) isolation Yes 1.5kV Weight 76kg Transportation protection Yes Operating voltage 44.8V - 55.6Vdc Indicator Led, programmable Communication CANBUS Addition IO 3 GPO Dimensions of SS4074: h/w/d (mm) Net Weight of SS4074 620/605 /200 72 kg Cell balancing Counters Passive balancing Cycle counters and SoH Battery cycle life [+25 ] > 4000 AUX power output 5V 1A max Charging efficiency 99% Storage duration 6 months@+25 Operating temperature Transport -5 ~+50 Safety standards compliance UN3480 & UN38.3 Cell Certificate IEC 62619/UN 38.3/UL1642 TUV / CE / RCM / UL1642 4 Unit 23, Alternator Park Montague Gardens 7441 Cape Town, South Africa Solar MD (PTY) ltd. E: info@solarmd.co.za T: (021) 555 2181. SS4074-11 INSTALLATION MANUAL v1.0 Mechanical installation Please use the correct mounting screws for the correct wall surface. Screw heads should not be larger than 16mm in diameter. The Battery is only to be installed in an upright position. The maximum allowed tilt is 30 degrees. 5 Unit 23, Alternator Park Montague Gardens 7441 Cape Town, South Africa Solar MD (PTY) ltd. E: info@solarmd.co.za T: (021) 555 2181. SS4074-11 INSTALLATION MANUAL v1.0 Installing bottom cover plate Figure 3 Bottom cover installation single or multiple batteries in line The Battery comes with two covers for single out or double out on both sides of the battery. Use the 1 or 2 way out cover plate and fix it with the two M5x6 bolts provided in the box. 6 Unit 23, Alternator Park Montague Gardens 7441 Cape Town, South Africa Solar MD (PTY) ltd. E: info@solarmd.co.za T: (021) 555 2181. SS4074-11 INSTALLATION MANUAL v1.0 Electrical installation Step 1. Before connecting anything be sure that the battery ON/OFF switch is at OFF position. (fig4 pos 3) Figure 4 BMS board component locations 7 Unit 23, Alternator Park Montague Gardens 7441 Cape Town, South Africa Solar MD (PTY) ltd. E: info@solarmd.co.za T: (021) 555 2181. SS4074-11 INSTALLATION MANUAL v1.0 Connecting Inverters/chargers/UPS to the battery unit while is ON can cause big sparks due to capacitors inside the connected device. This can be harmful for people. Connecting main battery terminal must be with correct size cable. based on the rated current of the battery and the charger/inverter in case it is lower. Figure 5 connection terminals Step 2. Connect the negative cable to the battery negative busbar and positive cable to the battery positive busbar as shown in figure 5. 8 Unit 23, Alternator Park Montague Gardens 7441 Cape Town, South Africa Solar MD (PTY) ltd. E: info@solarmd.co.za T: (021) 555 2181. SS4074-11 INSTALLATION MANUAL v1.0 Switching the Battery ON Step 1. Make sure all DC cables are tightened according specifications. Step 2. If the battery operates in parallel with other Energy sources, make sure that the difference between battery voltage and DC bus is not more than 2.5V. If greater than 2.5V please Charge or Discharge the other source accordingly until voltage difference is in safe ranges under 2.5V. Caution! A hot connection with difference in voltage can cause very high equalization current which can burn the fuses of the battery! Caution! Measure the voltage of the battery before connecting the dc Cables. Step 3. Turn the BMS board ON/OFF switch to the ON position (figure 4 pos 3). Step 4. Connect Multipurpose button if not connected to the BMS board connector (figure 4 pos 5). Step 5. Hold multi purpose button until the light comes on. Warning! If the battery does not switch the main protection Contact ON in 7 sec, please check BMS board indication LED for faults. See section BMS Error and Warnings. 9 Unit 23, Alternator Park Montague Gardens 7441 Cape Town, South Africa Solar MD (PTY) ltd. E: info@solarmd.co.za T: (021) 555 2181. SS4074-11 INSTALLATION MANUAL v1.0 Multicolor multipurpose button Figure 6 : Multicolor / Multipurpose button. Button functions The new Solar MD Multipurpose button has an extended functionality in combination with the BMS-EX. The Multipurpose Button can be used to directly execute 6 predefined functions and a shutdown instruction. In combination with the 6 Indication LEDs on BMS-EX, the user can choose between each function by holding the button until the LED count matches the number of the function. By releasing the button while moving through the functions, the LEDs will start blinking and wait for the user to press the button again within 3 seconds. The predefined functions are: 1. Reserved 2. Change indication LED function between: Show Capacity, Show Current, and Off 3. Reserved 4. Wake up if Sleep mode is active 5. Activate Override Off state for 60sec 6. Activate Override On state for 60sec If the button is held continuously after function 6, shutdown mode is activated and the battery will send a signal to switch off in 4sec. Further holding the button causes the BMS to delay complete shutdown for a maximum of 3 minutes. This operation is used when the technician wants to continue read or write parameters after shutdown. 10 Unit 23, Alternator Park Montague Gardens 7441 Cape Town, South Africa Solar MD (PTY) ltd. E: info@solarmd.co.za T: (021) 555 2181. SS4074-11 INSTALLATION MANUAL v1.0 Button indication **Access to all features in future development The Multipurpose button advanced indication functionality, allows the user to choose between 5 different states. Mixed combinations are also allowed when a combination of multiple batteries with BMS-EX are used. The User can change the prefered stage by logging into their mypower24 Energy Portal and go to the Battery Settings. Illumination off **For future development When this state has been selected, the button serves as an on/off switch without illumination (fixed colour). Color based on capacity When this state has been selected, the button shows static illumination in a color based on the state of charge. From RED at 0% SoC (State of Charge) to GREEN at 100% state of charge. Color based on capacity with current direction based on shading. **For future development When this state has been selected, the button shows flashing illumination in a color based on the state of charge and flashing code based on the electrical current direction (charge / discharge). From RED at 0% SoC (State of Charge) to GREEN at 100% state of charge. The flashing code for charge goes through illumination interruption for 1 interval and slow illumination into the color based on the SoC for 5 intervals. The flashing code for discharge represents the opposite from charge - study color for 1 interval and slow loss of color following illumination interruption. Solar MD users refer for both as charging / discharging waves. Fixed color with current direction based in shading **For future development When this state has been selected, the button shows illumination in a color based on the user choice and flashing code based on the electrical current direction (charge / discharge). The flashing code for charge goes through illumination interruption for 1 interval and slow illumination for 5 intervals. The flashing code for discharge represents the opposite from charge - study color for 1 interval and slow loss of color following illumination interruption. Solar MD users refer for both as charging / discharging waves. 11 Unit 23, Alternator Park Montague Gardens 7441 Cape Town, South Africa Solar MD (PTY) ltd. E: info@solarmd.co.za T: (021) 555 2181. SS4074-11 INSTALLATION MANUAL v1.0 BMS Warnings and Errors Method of displaying general warnings and errors: Figure 7 : Display general warnings and errors, Main status LEDs and Indication LEDs. The Status LEDs determine what the indication LEDs will show. 1. If the Status LED is Green the indication LEDs will show: a) Battery capacity b) Current flow and direction c) Off The functionality of the indication LEDs are configurable, see more on this: multifunction push button. 2. If the Warning LED is Orange a) The indication LEDs will show the warning number in binary, which corresponds to that tabulated below in the warning register. 3. If the Error LED is Red a) The indication LEDs will show the error number in binary, which corresponds to that tabulated below in the error register. 12 Unit 23, Alternator Park Montague Gardens 7441 Cape Town, South Africa Solar MD (PTY) ltd. E: info@solarmd.co.za T: (021) 555 2181. SS4074-11 INSTALLATION MANUAL v1.0 Warning codes. Figure 6. Indication LEDs: (1,2,3) orange left and (4,5,6) green right. In combination with Orange Stat LED (WARNING) + - Battery cell voltage is too low. [1] + - Battery cell voltage is too high. [2] + - Battery charging current is higher than the maximum allowed charging current . [3] + - Battery discharging current is higher than the maximum allowed electrical discharging current. [4] + - Override ON active, protection is forced to work at extreme levels for preset period. [5] + - Override OFF active, protection is forced to switched off the main protection relay for preset period. [6] + - Pending awake LOW state indicate that battery is forced to switched On for predefined amount of time normally 1min waiting for charger to start charging.[29] + - Pending awake HIGH state indicate that battery is forced to switched Off and waiting for all voltages to drop in safe margins.[30] Addition configuration are used for internal diagnostic. 13 Unit 23, Alternator Park Montague Gardens 7441 Cape Town, South Africa Solar MD (PTY) ltd. E: info@solarmd.co.za T: (021) 555 2181. SS4074-11 INSTALLATION MANUAL v1.0 Error codes. Figure 7. Indication LEDs: (1,2,3) orange left and (4,5,6) green right. In combination with Red Stat LED (ERROR) + - Battery position X axis is out of range. [5] + - Battery position Y axis is out of range. [6] + - Battery position Z axis is out of range. [7] + - Battery Protection in critical stage, pending shutdown in 3sec. [12] + - Battery Protection in critical stage, Override mode reached the maximum permitted values, pending shutdown in 3sec. [13] + - Battery Protection in critical stage, Normal mode reached the maximum permitted values, pending shutdown in 3sec. [14] + - Battery Protection in critical stage, pending shutdown in 3sec. [15] + - Remote Shutdown instruction received, pending shutdown in 3sec. [16] + - User Shutdown instruction received, pending shutdown in 3sec. [17] + - Discharging current is too high. [18] + - `` Charging current is too high. [19] + - Incorrect cell count detected. [21] + - Cell voltage too low. [22] 14 Unit 23, Alternator Park Montague Gardens 7441 Cape Town, South Africa Solar MD (PTY) ltd. E: info@solarmd.co.za T: (021) 555 2181. SS4074-11 INSTALLATION MANUAL v1.0 Error codes continued. Figure 8 Indication LEDs: (1,2,3) orange left and (4,5,6) green right. In combination with Red Stat LED (ERROR) + - Cell voltage too high. [23] + - Internal error. Additional information on request.[24] + - Internal error. Additional information on request.[25] + - Internal error. Additional information on request.[26] + - Internal error. Additional information on request.[27] + - Internal error. Additional information on request.[28] + - Internal error. Additional information on request.[29] + - Internal error. Additional information on request.[30] + - Internal error. Additional information on request.[31] 15 Unit 23, Alternator Park Montague Gardens 7441 Cape Town, South Africa Solar MD (PTY) ltd. E: info@solarmd.co.za T: (021) 555 2181. SS4074-11 INSTALLATION MANUAL v1.0 Error codes continued. Figure 8 Indication LEDs: (1,2,3) orange left and (4,5,6) green right. In combination with Red Stat LED (ERROR) + - Cell voltage too high. [23] + - Internal error. Additional information on request.[24] + - Internal error. Additional information on request.[25] + - Internal error. Additional information on request.[26] + - Internal error. Additional information on request.[27] + - Internal error. Additional information on request.[28] + - Internal error. Additional information on request.[29] + - Internal error. Additional information on request.[30] + - Internal error. Additional information on request.[31] 16 Unit 23, Alternator Park Montague Gardens 7441 Cape Town, South Africa Solar MD (PTY) ltd. E: info@solarmd.co.za T: (021) 555 2181. SS4074-11 INSTALLATION MANUAL v1.0 Error codes continued. Figure 8 Indication LEDs: (1,2,3) orange left and (4,5,6) green right. In combination with Red Stat LED (ERROR) + - Cell voltage too high. [23] + - Internal error. Additional information on request.[24] + - Internal error. Additional information on request.[25] + - Internal error. Additional information on request.[26] + - Internal error. Additional information on request.[27] + - Internal error. Additional information on request.[28] + - Internal error. Additional information on request.[29] + - Internal error. Additional information on request.[30] + - Internal error. Additional information on request.[31] 17 Unit 23, Alternator Park Montague Gardens 7441 Cape Town, South Africa Solar MD (PTY) ltd. E: info@solarmd.co.za T: (021) 555 2181. SS4074-11 INSTALLATION MANUAL v1.0 CANBUS connection. Bms EX used CAN 2.0B @ 500000 kb. Connecting other device operating at different speed rate is not allowed. For connection please use twisted pair wires in a shielded cable to minimize RF emissions. RJ45 connections can be used for daisy chaining BMS EX together using a straight Ethernet cable. The output of the Bms EX CAN transceiver is galvanically isolated. Figure 8: BMS-E connection to the CANBUS. 18 Unit 23, Alternator Park Montague Gardens 7441 Cape Town, South Africa Solar MD (PTY) ltd. E: info@solarmd.co.za T: (021) 555 2181. SS4074-11 INSTALLATION MANUAL v1.0 CANBUS warnings. Figure 9 CANBUS Termination resistor and Warning LED location The Orange LED (WARN) is used to display warning for canbus only. Reading this warning is possible with pulse counting. - CANBUS line open or no termination resistor set. [1] ...... - CAN BUS line in initialization stage. Canbus init occur when the line was opened and then established. Minimum period for initialization is 30sec. In this period all nodes are scanned in the network and scanned for ID and serial number collisions. [2] - Duplicate CAN ID detected with no "auto ID" set. [3] - Duplicate Serial number detected. [4] - CANBUS Internal fault. [5] 19 Unit 23, Alternator Park Montague Gardens 7441 Cape Town, South Africa Solar MD (PTY) ltd. E: info@solarmd.co.za T: (021) 555 2181. SS4074-11 INSTALLATION MANUAL v1.0 Troubleshooting Warnings / Errors Code Cause Solution Warnings ( Figure 6) 1-2 1. Inverter / rectifier settings may not be correct. 2. Battery cells may be disbalanced 1. Check the battery settings 2. Contact Solar MD support 3-4 System design is not correct. Add additional battery, decrease charging / discharging current from your inverter / rectifier / load 5-6 Manual override Manual override has been activated - please check with your installer 29-30 The BMS is ready to switch on after deep discharge / charge Connect charger / load to the Battery Errors (Figure 7 & 8) 5,6,7 The battery is not installed in upright position Install the battery in the right position 15,16,17 The BMS has been shut down manually or remotely Switch on the BMS 18,19 The absolute maximum charge/discharge current has been achieved The BMS will restart automatically, please contact support team or approved installer 21 The BMS is set for different number cells in series as the actually Contact your installer or Solar MD support team installed cvt22 Battery cell voltage way too low. Fill in the failure report and send to info@solarmd.co.za The unit needs to return to the factory for testing 23 Battery cell voltage way too high The BMS will restart automatically after pending awake condition 24,25,26, 27,28,30, 31 BMS Internal failure Fill in the failure report and send to info@solarmd.co.za The BMS will be dispatched to you for replacement 29 Battery factory failure Fill in the failure report and send to info@solarmd.co.za The unit needs to return to the factory for testing CANBUS Warning (Figure 10) 1 1. Canbus line open. 2. Single CANBUS resistor not terminated. 1.Check if the minimum of two nodes are connected on the line with the same transmission speed. 2.Check if single resistor is terminated via the jumper. Located top left of can LEDS(Fig 10). 20 Unit 23, Alternator Park Montague Gardens 7441 Cape Town, South Africa Solar MD (PTY) ltd. E: info@solarmd.co.za T: (021) 555 2181. SS4074-11 INSTALLATION MANUAL v1.0 Maximum charging / discharging voltages for non supported devices. - Bulk charge (stop charging) 54.6V - Float charge (if applicable) 53.8V - Low battery discharge: 48V Check that the Equalisation function are disalled, then verify if there is a voltage difference on the inverter display and the battery terminals @0.3C discharge / charge current. If so adjust the values above. Please check if your inverter charger has been approved by Solar MD and it is CAN compatible. For the latest Solar MD installation documents go to: www.solarmd.com To secure the full 10-year product warranty for the end user, be sure to register your battery online login.mypower24.co.za. 21