Instructions for BEA Sensors models including: LZR-I30, LZR-I30 Remote Control, Remote Control, Control
©BEA | Original Instructions 75.0043.03 REMOTE CONTROL 20231127 Page 5 of 15 APPENDIX: IS40 / IS40XL FUNCTIONS BUTTON FUNCTION FIELD SIZE (SENSITIVITY) XXS XS S > L XL XXL HOLD-OPEN TIME 0.5 s 1 s 2 s 3 s 4 s 5 s 6 s 7 s 8 s 9 s DETECTION MODE BI UNI UNI AWAY DETECTION FILTER All targets in motion
File Info : application/pdf, 15 Pages, 604.50KB
DocumentDocumentENGLISH Visit website for available languages of this document. KEYS REMOTE CONTROL How to use the remote control GENERAL KEYS Unlock Lock Check value Incremental increase Incremental decrease Setup / Teach-in Factory values Presettings FUNCTION KEYS See pages 3 12 for button assignments per product. COLOR KEYS LZR-FLATSCAN / Safety Motion / LZR-WIDESCAN Virtual Pull Cord Safety Reopening Presence PRODUCTS LZR-I30 / LZR-S600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 FALCON / FALCON EX / PHOENIX EX . . . . . . . . . . . . . 4 IS40 / IS40XL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 IS40P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 EAGLE ARTEK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 EAGLE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 EAGLE HIGH-MOUNT . . . . . . . . . . . . . . . . . . . . . . . . 9 BODYGUARD-T . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 LZR-FLATSCAN SW. . . . . . . . . . . . . . . . . . . . . . . . . . 11 LZR-FLATSCAN 3D SW . . . . . . . . . . . . . . . . . . . . . . . 12 ULTIMO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 IXIO-DT1 / IXIO-DT1 IND / IXIO-DT1 V . . . . . . . . . . 14 IXIO-ST / IXIO-ST IND . . . . . . . . . . . . . . . . . . . . . . . . 15 ©BEA | Original Instructions 75.0043.03 REMOTE CONTROL 20231127 Page 1 of 15 GENERAL REMOTE USE After unlocking, the red LED flashes and the sensor can be adjusted by remote control. If the red LED flashes quickly after unlocking, you need to enter an access code from 1 to 4 digits. ADJUSTING ONE OR MORE PARAMETERS To end an adjustment session, always lock the sensor. press UNLOCK choose parameter CHECKING A VALUE choose value press LOCK twice press UNLOCK choose parameter RESTORING TO FACTORY VALUES press ? x X = number of flashes = value of the parameter press LOCK twice press UNLOCK press MAGIC WAND SAVING AN ACCESS CODE press 9 * press LOCK twice * When no green LED is available, the signal is red. press UNLOCK press LOCK enter 4 digits The access code (1 4 digits) is recommended to set sensors that are installed close to each other. CHANGING AN ACCESS CODE press UNLOCK enter the existing code press LOCK enter 4 digits DELETING AN ACCESS CODE press UNLOCK enter the existing code press LOCK press 0 press LOCK If you forget the access code, proceed as follows: press UNLOCK Cut and restore power to the sensor 1 Min. During 1 minute, you can access the sensor without access code LED flashes quickly LED flashes LED flashes slowly LED flashes once 1x LED is off Tech Support: 1-800-407-4545 | Customer Service: 1-800-523-2462 | General Tech Questions: techservices-us@BEAsensors.com | www.BEAsensors.com ©BEA | Original Instructions 75.0043.03 REMOTE CONTROL 20231127 Page 2 of 15 APPENDIX: LZR-I30 / LZR-S600 FUNCTIONS BUTTON FUNCTION MOUNTING SIDE OPTIONAL FIELD WIDTH OPTIONAL FIELD HEIGHT SAFETY FIELD WIDTH SAFETY FIELD HEIGHT ACTIVE DETECTION CURTAINS UNCOVERED ZONE IMMUNITY FILTER deactivate curtain on both fields 2 in (S600 default) LEFT (background) activate curtain only on optional field 4 in (I30 default) environment: indoor RIGHT LEFT RIGHT CENTER (background) (no background) (no background) (no background) I30: no field = 000 / minimum = 020 / maximum = 360 / default = 200 S600: no field = 000 / minimum = 020 / maximum = 984 / default = 400 I30: no field = 000 / minimum = 020 / maximum = 360 / default = 200 S600: no field = 000 / minimum = 020 / maximum = 984 / default = 400 I30: no field = 000 / minimum = 020 / maximum = 360 / default = 200 S600: no field = 000 / minimum = 020 / maximum = 984 / default = 400 I30: no field = 000 / minimum = 020 / maximum = 360 / default = 200 S600: minimum = 004 / maximum = 984 / default = 400 activate curtain only on safety field 6 in 8 in 10 in environment: environment: environment: outdoor low outdoor med. outdoor high objects: indoor objects: objects: outdoor low outdoor med. objects: outdoor high MIN. OBJECT SIZE off 2 in 4 in 6 in 8 in OUTPUT ACTIVATION DELAY DETECTION FIELD REDIRECTION OUTPUT CONFIGURATION off R1: optional R2: safety 100 ms R1: optional or safety R2: safety R1: A - NO R2: P - NC 200 ms R1: P - NC R2: A - NO 300 ms R1: P - NC R2: P - NC 400 ms R1: A - NO R2: A - NO 500 ms 600 ms 700 ms 800 ms activate curtains on both fields 900 ms Click here for LZR-I30 User's Guide. Click here for LZR-S600 User's Guide. ©BEA | Original Instructions 75.0043.03 REMOTE CONTROL 20231127 Page 3 of 15 APPENDIX: FALCON, FALCON EX, PHOENIX EX FUNCTIONS BUTTON FUNCTION FIELD SIZE XXS XS S > > > > L XL XXL HOLD-OPEN TIME 0.5 s 1 s 2 s 3 s 4 s 5 s 6 s 7 s 8 s 9 s OUTPUT CONFIGURATION active passive DETECTION MODE BI UNI UNI AWAY DETECTION FILTER 1 2 3 4 5 6 Click here for FALCON Family User's Guide. Click here for FALCON EX Family User's Guide. Click here for PHOENIX EX Family User's Guide. ©BEA | Original Instructions 75.0043.03 REMOTE CONTROL 20231127 Page 4 of 15 APPENDIX: IS40 / IS40XL FUNCTIONS BUTTON FUNCTION FIELD SIZE (SENSITIVITY) XXS XS S > > > > HOLD-OPEN TIME 0.5 s 1 s 2 s 3 s 4 s 5 s 6 s DETECTION MODE DETECTION FILTER OUTPUT CONFIGURATION FREQUENCY MAX. PRESENCE DETECTION TIME AIR CURTAIN IMMUNITY Presence + Activation: standard mode 30 s BI UNI UNI AWAY All targets in motion Presence + Activation: pulse on entry All targets in motion + interference immunity Presence + Activation: pulse on exit Low `Pedestrian/ Parallel traffic' Rejection + Interference Immunity Presence + Activation: pulse on entry first / last line Medium `Pedestrian/ Parallel traffic' Rejection + Interference Immunity Presence + Activation: pulse on exit first / last line High `Pedestrian/ Parallel traffic' Rejection + Interference Immunity Presence + Activation: remains active (when motion is detected) until presence zone in cleared Extra High `Pedestrian/ Parallel traffic' Rejection + Interference Immunity Presence + Activation: remains active (when motion and AIR are detected) until presence zone in cleared A B 1 min 2 min 5 min 10 min 20 min 1 hr low normal high L 7 s 1.5 hr TARGET SIZE XL XXL 8 s 9 s 2 hr no learn AIR PATTERN SIZE Click here for IS40 / IS40XL User's Guide. ©BEA | Original Instructions 75.0043.03 REMOTE CONTROL 20231127 Page 5 of 15 APPENDIX: IS40P FUNCTIONS BUTTON FUNCTION RELAY CONFIGURATION OUTPUT REDIRECTION ACT: presence PRES: presence FREQUENCY MAX. PRESENCE DETECTION TIME 3 s AIR CURTAIN IMMUNITY Mot: active Pres: passive ACT: AIR entry pulse PRES: presence A 1 min low Mot: passive Pres: active ACT: AIR exit pulse PRES: presence B 2 min normal Mot: passive Pres: passive Mot: active Pres: active ACT: first/last line AIR entry pulse PRES: presence ACT: first/last line AIR exit pulse PRES: presence 5 min high 10 min ACT: presence PRES: presence 20 min ACT: presence PRES: presence 1 hr TARGET SIZE 1.5 hr AIR PATTERN SIZE 2 hr no learn Click here for IS40P User's Guide. ©BEA | Original Instructions 75.0043.03 REMOTE CONTROL 20231127 Page 6 of 15 APPENDIX: EAGLE ARTEK FUNCTIONS BUTTON FUNCTION FIELD SIZE RAD: SHAPE MOUNTING HEIGHT IMMUNITY FILTER DETECTION MODE 1 OUTPUT CONFIGURATION HOLD-OPEN TIME DOOR CONTROL 2 XXS XS S > > > > L XL = wide (default) = narrow To query the specific width, press . The sensor will blink the number of times that it is set to, and then the green LED will blink either 1 time (narrow shape) or 2 times (wide shape). Example: If FIELD SIZE = large and FIELD SHAPE = narrow, the LED with blink 7 times, and then 1 time. <10 ft > 10 ft low normal high > > > > > BI UNI UNI MTF UNI AWAY MTF & AWAY N.O. N.C. 0.5 s 1 s 2 s 3 s 4 s 5 s 6 s 7 s 8 s auto open closed FACTORY RESET full XXL highest 9 s partial 3 1 bi = two-way detection uni = one-way detection towards sensor uni MTF = one-way detection with motion-tracking feature uni AWAY = one-way detection away from sensor 2 open = sensor detects constantly, LED on. closed = sensor is in standby and does not detect, LED off 3 outputs are not reset Click here for EAGLE ARTEK User's Guide. ©BEA | Original Instructions 75.0043.03 REMOTE CONTROL 20231127 Page 7 of 15 APPENDIX: EAGLE FUNCTIONS BUTTON FUNCTION ZONE SIZE XXS IMMUNITY FILTER DETECTION MODE 1 OUTPUT CONFIGURATION 2 HOLD-OPEN TIME 0.5 s MOUNTING HEIGHT DOOR CONTROL 3 XS low BI A 1 s < 10 ft auto 1 bi = two-way detection uni = one-way detection towards sensor uni PRM = one-way detection also of people with reduced mobility uni AWAY = one-way detection away from sensor 2 A = active output (N.O. contact); relay energizes upon detection P = passive output (N.C. contact); relay de-energizes upon detection 3 open = sensor detects constantly, LED on. closed = sensor is in standby and does not detect, LED off S > > > > normal high > > > UNI UNI MTF UNI AWAY MTF & AWAY P 2 s 3 s 4 s 5 s 6 s > 10 ft open closed L XL XXL L XL highest 7 s 8 s 9 s Click here for EAGLE User's Guide. ©BEA | Original Instructions 75.0043.03 REMOTE CONTROL 20231127 Page 8 of 15 APPENDIX: EAGLE HIGH-MOUNT FUNCTIONS BUTTON FUNCTION ZONE SIZE XXS IMMUNITY FILTER DETECTION MODE 1 OUTPUT CONFIGURATION 2 HOLD-OPEN TIME 0.5 s MOUNTING HEIGHT DOOR CONTROL 3 XS low BI A 1 s < 10 ft auto 1 bi = two-way detection uni = one-way detection towards sensor uni PRM = one-way detection also of people with reduced mobility uni AWAY = one-way detection away from sensor 2 A = active output (N.O. contact); relay energizes upon detection P = passive output (N.C. contact); relay de-energizes upon detection 3 open = sensor detects constantly, LED on. closed = sensor is in standby and does not detect, LED off S > > > > L XL XXL normal high > > > L XL highest UNI UNI MTF UNI AWAY MTF & AWAY P 2 s 3 s 4 s 5 s 6 s 7 s 8 s 9 s > 10 ft open closed Click here for EAGLE HIGH-MOUNT User's Guide. ©BEA | Original Instructions 75.0043.03 REMOTE CONTROL 20231127 Page 9 of 15 APPENDIX: BODYGUARD-T FUNCTIONS BUTTON FUNCTION INTERFACE DOOR CONTROL MODES OF OPERATION INFRARED FREQUENCY SENSITIVITY HOLD TIME OUTPUT CONFIGURATION AUTO-LEARN TIME PATTERN WIDTH PATTERN DEPTH IMMUNITY * default 6 = door closed, default 7 = door open normal min 0.5 s 30 s new style normal old style (LO21) door permanently open door permanently closed MP mode Record mode Mode: normal Mode: normal Mode: quiet Freq: low Freq: high Freq: low Mode: quiet Freq: high > > > > > > * > * > > > > > > > > > > 9 s N.O. N.C. 1 m 2 m 3 m 5 m 7 m 10 m wide (closed door) deep (threshold on) low (normal) middle (open door) medium (threshold on, open) medium (rain) asymm. left narrow limited (threshold on) high (snow) asymm. right narrow deep (threshold off) narrow left medium (threshold off, closed) narrow right limited (threshold off) 15 m asymm. left wide 10 s infinite asymm. right wide center narrow Click here for IS40 / IS40XL User's Guide. ©BEA | Original Instructions 75.0043.03 REMOTE CONTROL 20231127 Page 10 of 15 APPENDIX: LZR-FLATSCAN SW FUNCTIONS BUTTON FUNCTION PINCH ZONE WIDTH PINCH ZONE HEIGHT DOOR LEAF WIDTH DOOR LEAF HEIGHT OUTPUT CONFIGURATION IMMUNITY FILTER UNCOVERED ZONE ANTIMASKING & BACKGROUND OFF / OFF R1: NO R2: NC low 3/4 in OFF / ON no field = 000 / minimum = 001 / maximum = 040 / default = 015 no field = 000 / minimum = 001 / maximum = 157 / default = 157 no field = 000 / minimum = 001 / maximum = 157 / default = 157 no field = 000 / minimum = 001 / maximum = 157 / default = 157 R1: NC R2: NO R1: NC R2: NC R1: NO R2: NO > > > > > > > high 1 1/2 in 2 1/4 in 3 in 4 in 4 3/4 in 5 1/2 in 6 1/4 in 7 in ON / OFF ON / ON Click here for LZR-FLATSCAN SW User's Guide. ©BEA | Original Instructions 75.0043.03 REMOTE CONTROL 20231127 Page 11 of 15 APPENDIX: LZR-FLATSCAN 3D SW FUNCTIONS BUTTON FUNCTION PINCH ZONE WIDTH DOOR LEAF WIDTH DOOR LEAF HEIGHT OUTPUT CONFIGURATION 1 UNCOVERED ZONE ANTIMASKING / BACKGROUND OFF / OFF N.O. 3/4 in OFF / ON no field = 000 / minimum = 001 / maximum = 040 / default = 015 no field = 000 / minimum = 001 / maximum = 157 / default = 157 no field = 000 / minimum = 001 / maximum = 157 / default = 157 N.C. 1 1/2 in 2 3/8 in 3 1/4 in 4 in 4 3/4 in ON / OFF ON / ON 5 1/2 in DETECTION FIELD DEPTH 1 Always enter 3 digits for output parameters: · 1st digit refers to Output 1 (O1) = STOP · 2nd digit refers to Output 2 (O2) = REOPEN · 3rd digit refers to Output 3 (O3) = VIRTUAL PUSH BUTTON 1 curtain 2 curtains 3 curtains 4 curtains Click here for LZR-FLATSCAN 3D SW User's Guide. ©BEA | Original Instructions 75.0043.03 REMOTE CONTROL 20231127 Page 12 of 15 APPENDIX: ULTIMO FUNCTIONS BUTTON FUNCTION IR:Width IR:Curtains IR:Immunity IR:PresTime IR:Freq Rad:Fieldsize Rad:Shape Rad:Direction Rad:Immunity Out1Funct 3 Out1Logic Out1HoldTime InTestMode FactoryRst wide standard narrow left, angled right, angled 0 1 2 3 4 5 6 7 normal outdoor enhanced 30 sec 1 min 2 min 5 min 10 min 20 min 60 min infinite auto-synch IXIO 1 freq A 2 freq B 2 small > > > > > > > > large LCD: "narrow" and "wide" setting options Remote Control: After pressing the Rad:Fieldsize button, use the plus sign button to select the Wide shape or the minus sign button to select the Narrow shape. Numeric remote control buttons are only applicable to the Rad:Fieldsize function. off BI <>| UNI >| MTF <| low > > > > > > > high off RAD or IR RAD N.O. N.C. 0.5 sec 1 sec 2 sec 3 sec 4 sec 5 sec 6 sec 7 sec 8 sec 9 sec off on auto full partial 4 1 > V5.0 auto-synch 2 for use with IXIO if synchronization issues occur 3 The sensor LED will briefly flash RED during monitoring communication with the door control. This indicates that external monitoring is functional. Monitoring functionality must be active on the sensor and door control, and monitoring wires must be properly connected to the door control. 4 Partial reset is only available via remote control. Partial restores all adjustable settings except Out1Logic and Out2Logic. Click here for ULTIMO User's Guide. ©BEA | Original Instructions 75.0043.03 REMOTE CONTROL 20231127 Page 13 of 15 APPENDIX: IXIO-DT1 / DT1 IND / DT1 V FUNCTIONS BUTTON FUNCTION RAD: FIELDSIZE RAD: SHAPE RAD: IMMUNITY small > > > LCD: "narrow" and "wide" setting options (default = wide) Remote Control: = wide, = narrow low > > RAD: DIRECTION 1 off BI UNI MTF RAD: HOLDTIME 0.5 sec 1 sec 2 sec 3 sec RAD: REENTRY RAD: OUTPUT 2 AIR: OUTPUT 2 AIR: IMMUNITY small > DeEner/N.O. N.C. DeEner/N.O. N.C. normal > Ener/N.C. N.O. Ener/N.C. N.O. enhanced > Ener/N.C. N.C. Ener/N.C. N.C. AIR: NUMBER 1 2 AIR: PRESENCE TIME 30 sec 1 min AIR: FREQ A B TEST 3 REDIRECTION 4 off R1 MW R2 IR on R1 MW or IR R2 IR FACTORY RESET 5 > > 4 sec > DeEner/N.O. N.O. DeEner/N.O. N.O. 2 min 1 MTF = motion tracking feature uni + reentry: BEA recommends only adjusting using the LCD 2 RADAR: DeEner = de-energized relay, Energ = energized relay; N.O. = normally open, N.C. = normally closed AIR: N.O. = normally open, N.C. = normally closed 3 The sensor LED will briefly flash RED during monitoring communication with door control. This indicates that external monitoring is functional. Monitoring functionality must be active on the sensor and door control, and monitoring wires must be properly connected to the door control. 4 REDIRECTION setting (F1 on remote control): R1-MW, R2-IR (F1=0): R1 = MW (i.e. motion detection) R2 = IR (i.e. presence detection) R1-MW or IR, R2-IR (F1=1): R1 = MW or IR (i.e. motion or presence detection) R2 = IR (i.e. presence detection) 5 partial: outputs are not reset ©BEA | Original Instructions 75.0043.03 REMOTE CONTROL 20231127 > > 5 sec > 5 min > > > large > 6 sec > > 7 sec > > uni + reentry 8 sec > high 9 sec large mode B 10 min 20 min 60 min infinite full partial Click here for IXIO-DT1 User's Guide. Click here for IXIO-DT1 INDUSTRIAL User's Guide. Click here for IXIO-DT1 V User's Guide. Page 14 of 15 APPENDIX: IXIO-ST / ST IND FUNCTIONS BUTTON FUNCTION AIR: OUTPUT 1 AIR: IMMUNITY AIR: NUMBER AIR: PRESENCE TIME AIR: FREQ TEST 2 off FACTORY RESET 3 DeEner/N.O. N.C. normal 1 A on Ener/N.C. N.O. enhanced 2 30 sec B Ener/N.C. N.C. DeEner/N.O. N.O. 1 min 2 min 5 min 1 N.O. = normally open, N.C. = normally closed 2 The sensor LED will briefly flash RED during monitoring communication with door control. This indicates that external monitoring is functional. Monitoring functionality must be active on the sensor and door control, and monitoring wires must be properly connected to the door control. 3 partial: outputs are not reset mode B 10 min 20 min 60 min infinite full partial Click here for IXIO-ST User's Guide. Click here for IXIO-ST INDUSTRIAL User's Guide. ©BEA | Original Instructions 75.0043.03 REMOTE CONTROL 20231127 Page 15 of 15