GMI Series Micro Inverter User Manual
This manual provides detailed information for the GMI Series Micro Inverters, including installation, operation, and safety guidelines.
Basic Structure and Packing List
The basic structure of the GMI Series Micro Inverter includes PV connectors, AC connectors, status indicator, and mounting holes. The packing list typically contains one Microinverter unit and one AC cable.
AC Cable Description: The AC cable has three conductors: L (BROWN) for Live, N (BLUE) for Neutral, and G (GREEN&YELLOW) for Ground.
Parameter Table
Product Series | Model | Input Data (DC, PV) | Number of Input MC4 Connector | MPPT Voltage Range | Operation Voltage Range | Maximum Input Voltage | Startup Voltage | Maximum Input Power | Maximum Input Current | Output Data (AC) | Single-Phase Grid Type | Rated Output Power | Maximum Output Power | Nominal Output Current | Nominal Output Voltage | Default Output Voltage Range | Nominal Output Frequency | Default Output Frequency Range | Power Factor | Total Harmonic Distortion | Efficiency | Peak Efficiency | CEC Weighted Efficiency | Nominal MPPT Efficiency | Night Power Consumption | Mechanical Data | Operating Ambient Temperature Range | Storage Temperature Range | Dimensions (WxHxD) | Weight | Waterproof Grade | Cooling Mode | Other Features | Transformer Design | Integrated Ground | Protection Functions |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
GM1500-700 Series | GM1500 | DC 24V-40V | 1 set | 24V-40V | 18V-50V | 50V | 18V | 500W | 20A | AC 120V / 230V | 120V: 4.08A / 230V: 2.13A | 580W | 600W | 120VAC / 230VAC | @120VAC: 80V-160V / @230VAC: 180V-280V | 50Hz / 60Hz | @50Hz: 47.5Hz-52.5Hz / @60Hz: 57.5Hz-62.5Hz | >0.99 | THD <5% | 92% | @120VAC: 90% / @230VAC: 90.5% | 99.9% | <700mW | -40°C to +65°C | -40°C to +85°C | 41mm x 106mm x 282mm | 0.95kg | IP55 | Natural Convection - No Fans | High Frequency Transformers, Galvanically Isolated | Equipment ground is provided by the PE in the AC cable. No additional ground is required. | Isolated Island, Voltage, Frequency, Temperature, Current etc. | ||||
GM1500-700 Series | GM1600 | DC 24V-40V | 1 set | 24V-40V | 18V-50V | 50V | 18V | 600W | 24A | AC 120V / 230V | 120V: 4.83A / 230V: 2.52A | 650W | 700W | 120VAC / 230VAC | @120VAC: 80V-160V / @230VAC: 180V-280V | 50Hz / 60Hz | @50Hz: 47.5Hz-52.5Hz / @60Hz: 57.5Hz-62.5Hz | >0.99 | THD <5% | 92% | @120VAC: 90% / @230VAC: 90.5% | 99.9% | <700mW | -40°C to +65°C | -40°C to +85°C | 41mm x 106mm x 282mm | 0.95kg | IP55 | Natural Convection - No Fans | High Frequency Transformers, Galvanically Isolated | Equipment ground is provided by the PE in the AC cable. No additional ground is required. | Isolated Island, Voltage, Frequency, Temperature, Current etc. | ||||
GM1500-700 Series | GM1700 | DC 24V-40V | 1 set | 24V-40V | 18V-50V | 50V | 18V | 700W | 28A | AC 120V / 230V | 120V: 5.41A / 230V: 2.82A | 700W | 700W | 120VAC / 230VAC | @120VAC: 80V-160V / @230VAC: 180V-280V | 50Hz / 60Hz | @50Hz: 47.5Hz-52.5Hz / @60Hz: 57.5Hz-62.5Hz | >0.99 | THD <5% | 92% | @120VAC: 90% / @230VAC: 90.5% | 99.9% | <700mW | -40°C to +65°C | -40°C to +85°C | 41mm x 106mm x 282mm | 0.95kg | IP55 | Natural Convection - No Fans | High Frequency Transformers, Galvanically Isolated | Equipment ground is provided by the PE in the AC cable. No additional ground is required. | Isolated Island, Voltage, Frequency, Temperature, Current etc. |
*Specifications subject to change without notice
Safety Precautions
DANGER! 有电危险!
- Read user manual before operating this equipment. Failure to do so can result in serious injury, property damage, and/or electrical shock.
- Use photovoltaic panel(s) ONLY connect to this equipment.
- This equipment is an ON-GRID Microinverter. To make it work properly, it must be connected to the power grid correctly, and the power grid must be working properly. When the power grid stops working, it will also stop generating.
- Do NOT exceed PV panel(s) voltage over the inverter's maximum input voltage.
- Do NOT exceed PV panel(s) power over the inverter's maximum input power.
- DC voltage sources are pass through this equipment. Each circuit must be individually disconnected before servicing.
- Do NOT cover other items on this equipment.
- Do NOT remove the lid. Servicing must be performed by qualified service personnel.
- When PV array is exposed to light, it supplies DC voltage to this equipment. Be cautious.
- Install away from direct sunlight and direct rain exposure.
LED Display Indicators
- Green light steady: Microinverter is generating power normally.
- Red flash: Microinverter is in waiting mode.
- Red light steady: Indicates one of the following conditions:
- Island protection
- Over-temperature protection
- Over/low AC voltage protection
- Over/low DC voltage protection
- Over/low AC frequency protection
- Fault (hardware malfunction)
Installation Procedures
Important: Prior to installing the Microinverters, please verify that the utility voltage at the point of common grid connection matches the voltage rating on the Microinverter label.
- Step 1: Attaching the Microinverters to the Racking. Mark the location of the Microinverter on the rack, considering the PV module junction box or other obstructions. Mount one Microinverter at each location using hardware recommended by your module racking vendor.
- Step 2: Connecting the Microinverter AC cable. Connect the AC cables to the AC bus cable, ensuring correct wiring (L-BROWN, N-BLUE, G-GREEN&YELLOW). Do NOT exceed the maximum current rating of the AC bus cable.
- Step 3: Connecting Microinverters to the PV Module. Connect the PV modules to the Microinverters. Ensure the PV panel(s) VOC does not exceed the inverter's maximum input voltage.
- Step 4: Install the AC Branch Circuit Junction Box. Wire the conductors of the AC bus cable to the junction box. Connect the AC branch circuit junction box to the point of utility-grid interconnection.
- Step 5: Double Check Connections. Verify that all Microinverters, connectors, and cables are correctly and securely connected.
- Step 6: Turn ON AC Circuit Breakers. Close the AC circuit breaker for each AC branch circuit of the Microinverter.
- Step 7: Turn ON Main AC Circuit Breaker. Close the main AC circuit breaker of the utility-grid. The system will start producing power after a 3-second safety delay.
Wiring and Installation Schematics
The manual includes detailed wiring schematics for various configurations:
- GMI Series-120/230VAC @ Single Phase 120/230V
- GMI Series-230VAC @ 3-Phase 380V (230V inverter connected to 3-phase 380V grid)
- GMI Series-230VAC @ 2-Phase 208/240V (230V inverter connected to 2-phase 208/240V grid)
- GMI Series-230VAC @ 3-Phase 208/240V (230V inverter connected to 3-phase 208/240V grid)
- GMI Series-120VAC @ 3-Phase 208/240V (120V inverter connected to 3-phase 208/240V grid)
These diagrams illustrate the connections between the Microinverter, PV modules, AC bus cable, distribution panel, and the grid connection point, including breakers and meters.