Instruction Manual for BITMAIN models including: S19 XP Hyd. 257T, S19 XP Hyd. 246T, S19 XP Hyd. 235T, S19 XP Hyd. 224T, ANTMINER S19 XP Hyd Server, ANTMINER S19 XP Hyd, ANTMINER, Server

S19 XP Hyd. Product Manual

BTIMAIN, ANTMINER, S19, XP, Hyd.

Avi Eliav


File Info : application/pdf, 5 Pages, 824.61KB

PDF preview unavailable. Download the PDF instead.

S19 XP Hyd. Product Manual v1.4.1
S19 XP Hyd.
Product Manual
Jul. 2024
BITMAIN TECHNOLOGIES INC. www.bitmain.com

1. Specification

S19 XP Hyd. Product Manual

Product Glance
Model Sub Version Crypto algorithm/coins Typical hashrate, TH/s(1-1) Power on wall @35(1-2), Watt(1-1) Power efficiency on wall@35(1-2), J/T(1-1)

Value
S19 XP Hyd. 257T 246T 235T 224T
10 SHA256| BTC/BCH/BSV 257 246 235 224 5346 5117 4888 4660
20.8

Detailed Characteristics

Value

Power Supply Phase Input voltage, Volt(2-1) Input frequency range, Hz Input max current, Amp

3 380~415
50~60 12

Hardware Configuration Network connection mode Server size (length*width*height, w/o package), mm Server size (length*width*height, with package), mm Net weight, kg Gross weight, kg

RJ45 Ethernet 10/100M 410*170*209 570*316*430 12.8 14.1

Environment Requirements

Inlet coolant temperature, °C

20-40

Coolant flow, L/min

8.0~10.0

Coolant pressure, bar

3.5

Working coolant(2-2) Coolant pH value

Antifreeze/ Pure water/Deionized water
Antifreeze: 7.0~9.0 Prue water: 6.5~7.5 Deionized water8.5~9.5

Diameter of coolant pipe connector, mm

OD10

Storage temperature, °C

-20~70

Operation humidity(non-condensing), RH

10~90%

Notes:

(1-1) The hashrate value, power on wall, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ± 3%, and the actual power on wall and power efficiency on wall fluctuate by ±5%. (1-2) Inlet coolant temperature. (2-1) Caution: Wrong input voltage may cause server damaged. (2-2) For detailed working coolant use and maintenance instructions, please refer to "ANTSPACE HK3 Water Cooling Container & Dry-Wet Tower Product Manual", Chapter 9, Article 3, Point 6, "Maintenance of Coolant"!

-2-

2. Performance Curve
(1) Hashrate vs. Inlet Coolant Temperature

S19 XP Hyd. Product Manual

-3-

S19 XP Hyd. Product Manual -4-

(2) Power Efficiency vs. Inlet Coolant Temperature

S19 XP Hyd. Product Manual