01 Safety Precautions
General Disclaimer
· The information in this quick installation guide is subject to change due to product updates or other reasons. This guide cannot replace the product labels or the safety precautions in the user manual unless otherwise specified. All descriptions here are for guidance only.
· Before installations, read through the quick installation guide and the user manual to learn about the product and the precautions.
· All installations should be performed by trained and knowledgeable technicians who are familiar with local standards and safety regulations.
· Check the deliverables for correct model, complete contents, and intact appearance. Contact GoodWe if any damage is found or any component is missing.
· Use insulating tools and wear personal protective equipment when operating the equipment to ensure personal safety. Wear anti-static gloves, clothes, and wrist strip when touching electron devices to protect the inverter from damage.
· Strictly follow the installation, operation, and configuration instructions in this guide and user manual. GoodWe shall not be liable for equipment damage or personal injury if you do not follow the instructions. For more warranty details, please visit http://www.goodwe.com.
Safety Disclaimer
Warning
DC Side:
1. Ensure the component frames and the bracket system are securely grounded. 2. Connect the DC cables using the delivered DC connectors and terminals. GoodWe shall not
be liable for the equipment damage if other connectors or terminals are used. 3. Ensure the DC cables are connected tightly and securely. 4. Measure the DC cable using the multimeter to avoid reverse polarity connection. Also, the
voltage should be under the permissible range (600V).
AC Side
1. The voltage and frequency at the connecting point should meet the on-grid requirements. 2. An additional protective device like the circuit breaker or fuse is recommended on the AC
side. Specification of the protective device should be at least 1.25 times the AC output rated current. 3. PE cable of the inverter must be connected firmly. The resistance between the neutral wire and the earth cable is less than 10. 4. You are recommended to use copper cables as AC output cables. Contact GoodWe if you want to use aluminum cables.
Inverter Side
1. Terminals at the bottom of the inverter cannot bear much load. Otherwise, the terminals will be damaged.
2. All labels and warning marks should be clear after the installation. Do not scrawl, damage, or block any label on the device.
3. Warning labels on the inverter are as following.
01

High voltage hazard. Power off the inverter first before any operations.
Read through the guide before any operations.
High-temperature hazard. Do not touch the equipment to avoid being burnt.

5min
N/A

Potential risks exist. Wear proper PPE before any operations.
Delayed discharge. Wait until the components are totally discharged after power off.
N/A

02

02 Product Introduction
Parts

12

34 5

67 8 9

10

11

1. PV Input Terminal

2. DC Switch

4.

DRED/CT/Remote Shut down Communication Cable Port

5.

AC Output Terminal

7. LCD

8. Button

10. Mounting Plate

11. Heat Sink

Dimensions

354mm

WiFi/4G/LAN/GPRS Communication 3. Module Port or RS485
Communication Cable Port 6. Indicator 9. PE Terminal
147mm

115mm 433mm

195mm 32.5mm 32.5mm
130mm

03

03 Inverter Installation
Package

Inverter*1

Mounting Bracket*1

Expansion Bolts

Postive DC Terminal*2

Negative DC Terminal*2

or

AC Connector*1
Documentation *1

Spare Screws

Communication 2PIN Terminal Module*1

PE OT Terminal*1

· Number of expansion bolts, screws, and terminals are various depending on the different inverters. The actual accessories may differ.
· Communication module types: WiFi/4G/LAN/GPRS etc. The actual module delivered depends on the communication method of the selected inverter.
· 2PIN terminal is used to connect CT communication cable.

Space Requirements 15kg

200mm

300mm 200mm

300mm

500mm

-25~60
IP65
0%~100%RH
04

Angle Requirements
15°

Installing the Inverter Avoid the water pipes and cables buried in the wall when drilling holes.

1

2

3

4 5 6 M5 1.2~2N·m
05

04 Electrical Connection
Connecting the PE Cable

1

L=L1+(1~2)mm

L1

S4mm2

2

3

Connecting the AC Cable

M5 1.2~2N·m

Click

The two types of AC connector will be delivered randomly. The actual connector may differ.
Type One AC Connector

1 8-10mm

: 8-10mm

10-15mm

2.5mm2S4mm2

2
3 1
2

6

4

5

3

06

3
L N PE

M3 0.8N·m

4 AC OUTPUT

5 3

1 2

6
4 Click

Type Two AC Connector
1 10-12mm
: 10-12mm 10-15mm 2.5mm2S4mm2

2
5 1
2

8
6 3
7 4

3
L N PE

M3 0.8N·m

4 AC OUTPUT

5

3

1

6

4 2

7
8 Click

07

Connecting the DC Cable

Click

1 7~8mm

: 4~5mm

7~8mm

2.5mm2S4mm2
3 4
3 2
1

2
4 3 2 1

4 1

5 PV1+ PV2+

2

PV1-

PV2-

1
2 Click

600V

Click

08

Connecting the DRED/Remote Shutdown Communication Cable (Optional)
Contat the after-sales service to get the DRED terminal if you need to use DRED function. DRED function is off by default. Start this function via SolarGo App if it's needed.

6.5mm

CT DRED

25mm

Remote Shutdown 6: Reserved 5: Reserved 4: Reserved 3: DRM4/8 2: REFGEN 1: Reserved
DRED 6: DRM1/5 5: DRM2/6 4: DRM3/7 3: DRM4/8 2: REFGEN 1: COM/DRM0

3
6 5 4 3 2 1

CT

4

4

1
2
DRED

4

M3

4

4

4

0.8N·m

Connecting the CT Communication Cable (Optional)

CT DRED

4

CT

3

3

2

DRED

3

3

6.5mm 25mm

1

1

2: CT-

3

1: CT+

2 1

4

M3

0.8N·m

CT
4

41 2

1

DDRREEDD

4

4

4 CT

3

3

2

DRED

3

3

4

Note: Connect the CT using two cables. Connect CT+ to the CT+ port of the inverter, and CT- to the CT- port of the inverter. The color of the CT+ cable can be white, black and white, or red. The color of the CT- cable is black. Connect the CT cable properly, otherwise, the CT cannot work.

09

Connecting the RS485 Communication Cable(Optional)
RS485

6.5mm 25mm

1

3

RSC4T85

6: RS485+ 5: RS485-

6 5

4

41

4: Reserved

4

3: Reserved 2: RS485+

3 2 1

2

1: RS485-

1

DRED

4

M3

4

4

4

0.8N·m

4

RS485

3

3

2

3

3

Installing the Communication Module(Optional)
The appearacne of communication moduels is slightly different. But the modules are installed in the same way. The following figure shows you how to install a WiFi module.

05 Check before Power-on

No.

Check Item

1

The inverter is firmly installed in a clean place where is well-ventilated and easy to operate.

2

The PE cable, DC input cable, AC output cable, and communication cable are connected correctly and securely.

3 Cable ties are routed properly and evenly, and no burrs.

4 Unused ports and terminals are sealed.

5 The voltage and frequency at the connection point meet the grid-tied requirements.

10

06 Power On
1. If it displays Select Country/Region on the LCD when you power on the equipment for the first time, you can set the safety country via the LCD or SolarGo APP. For more details, refer to Commissioning part. For other settings, please refer to the user manual.
2. Observe the indicators to check the inverter status. If any fault exists, please refer to the Troubleshooting part in the user manual.

DNS Series User Manual

PV

3

PV

DC Switch

Inverter 1
AC Switch Grid
ON

OFF

2

DC Switch

Indicator Power
Operating Faulty

Status Steady Yellow

Power on

Description

Single Yellow Blinking WiFi module reset or restore

Double Yellow Blinking Not connected to the router

Quadra Yellow Blinking Not connected to the monitoring website

Yellow Blinking

RS485 communication normal

Off Steady Green
Off Steady Red Off

The WiFi module is restoring factory settings. The power grid is working normally and on-grid. Off grid System error No error

07 Commissioning Commissioning via LCD

1. Select the right safety country accordingly.

Long Press 2s

Select Country/Region

China

Short Press

China

2. Wait for 20s, the inverter will automatically set the safety country and back to the standby page.

11

Commissioning via SolarGo APP

Note
1. Search for"SolarGo APP"in Google Play or App Store 2. Operation steps are the same for Android system and iOS system, although
the two interfaces are slightly different. The introduction here is based on Android system. 3. Log in using the initial password for the first time and change the password as soon as possible. To ensure account security, you are advised to change the password periodically and keep the new password in mind.

SolarGo App

3

Bluetooth: SOL-BLE********

WiFi: SOL-WiFi********

Initial Password for WiFi:

12345678

Scan the QR code on the

equipment if you need to use

2

GPRS.

* are the last 8 digits of the

inverter SN.

1

VIRGIN

4:21 PM

100%

Grid connection parameters

Basic setting

Connection Jump off setting

Safety option

VDE4110

5

Grid connection

Triangle Grid (3W/PE)

6

4
· Initial Password for WiFi&bluetooth: 1234
· Initial Password for GPRS: the last 4 digits of the inverter bar code.