Instruction Manual for ERICO models including: CSBBRS2EG Branch Line Restraint, CSBBRS2EG, Branch Line Restraint, Line Restraint, Restraint
File Info : application/pdf, 4 Pages, 790.51KB
DocumentDocumentINSTRUCTION SHEET CSBBRS2EG Branch Line Restraint, Structural Attachment Fitting for Concrete or Wood NA Part Number CSBBRS2EG CSBBRS2MEG EU Article Number --402240 Rod Size 3/8", 1/2" M10, M12 UL® Load Rating 425 lbs (1891N) 45 - 59 290 lbs (1290N) FM® Load Rating 60 - 74 200 lbs (890N) 75 - 90 210 lbs (935N) Rod Root Least Radius of Gyration Size Dia. r 3/8" 0.300" 0.075" M10 7.94mm 1.99mm 1/2" 0.404" 0.101" M12 9.60mm 2.40mm Reference: NFPA®13, (2007) *Reference: NFPA13, (2010) L/r = 100 7" 198mm 10" 240mm Maximum Unbraced Length (L) L/r = 200 14" 397mm 20" 480mm L/r = 300 22" 595mm 30" 720mm L/r = 400* 30" 794mm 40" 960mm 1. Orient part in direction needed for installation. 2. For concrete, pre-drill using 3/16" taper bit drill at least 2-1/4" deep. Clear the hole of dust and other material. For installation in wood start at step 3. 3. Use standard screw gun with a depth sensitive nose piece or clutch for correct seating of fastener. Use a size 5/16" [8mm] hex head socket or flat head screwdriver. Drive the anchor in a continuous motion until fastener is fully seated. Powers Fastener part number 2722sd. For more information go to www.powers.com Anchor NOT pre-qualified for use in cracked concrete. 3/8"-16 side 1/2"-13 side Used for concrete or wood. 4. Rotate barrel to 3/8"-16 side or 1/2"-13 side, based on threaded rod needed for application. Branch Line Restraints are intended to be installed in accordance with NFPA®-13 and manufacturer's installation instructions. WARNING: 1. ERICO products shall be installed and used only as indicated in ERICO product instruction sheets and training materials. Instruction sheets are available at www.erico.com and from your ERICO customer service representative. 2. ERICO products must never be used for a purpose other than the purpose for which they were designed or in a manner that exceeds specified load ratings. 3. All instructions must be completely followed to ensure proper and safe installation and performance. 4. Improper installation, misuse, misapplication or other failure to completely follow ERICO's instructions and warnings may cause product malfunction, property damage, serious bodily injury and death. 5. Products that are manufactured using spring steel components shall be used only in a non-corrosive indoor environment. 6. All pipe supports, hangers, intermediate components and structural attachments must ONLY be used as described herein and are NEVER to be used for any other purpose. NOTE: All load ratings are for static conditions and do not account for dynamic loading such as wind, water or seismic loads, unless otherwise noted. The customer is responsible for: a. Conformance to all governing codes. b. The integrity of structures to which the products are attached, including their capability of safely accepting the loads imposed, as evaluated by a qualified engineer. c. Using appropriate industry standard hardware as noted above. SAFETY INSTRUCTIONS: All governing codes and regulations and those required by the job site must be observed. Always use appropriate safety equipment such as eye protection, hard hat, and gloves as appropriate to the application. FM is a registered certification mark of FM Approvals LLC, LTD NFPA is a registered trademark of National Fire Protection Association, Inc. UL is a registered trademark of UL LLC CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH, and LENTON are registered trademarks of ERICO International Corporation. TECHNICAL SUPPORT: www.erico.com CFS448_E 1 OF 4 © 2011, 2012, 2013 ERICO International Corporation. INSTRUCTION SHEET CSBBRS2EG Branch Line Restraint, Structural Attachment Fitting for Concrete or Wood A A B B Correct Installation SECTION A-A SCALE 1 : 1 5. Fully thread rod into barrel nut. Incorrect Installation Rod not fully threaded into barrel nut. SECTION B-B SCALE 1 : 1 CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH, and LENTON are registered trademarks of ERICO International Corporation. TECHNICAL SUPPORT: www.erico.com CFS448_E 2 OF 4 © 2011, 2012, 2013 ERICO International Corporation. INSTRUCTION SHEET CSBBRS2EG Branch Line Restraint, Structural Attachment Fitting for Concrete or Wood Branch Line Restraint System attached to concrete CSBBRS2 This product is intended to be used as a restraint and not a hanger. CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH, and LENTON are registered trademarks of ERICO International Corporation. TECHNICAL SUPPORT: www.erico.com CFS448_E 3 OF 4 © 2011, 2012, 2013 ERICO International Corporation. INSTRUCTION SHEET CSBBRS2EG Branch Line Restraint, Structural Attachment Fitting for Concrete or Wood Branch Line Restraint System attached to wood. This product is intended to be used as a restraint and not a hanger. CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH, and LENTON are registered trademarks of ERICO International Corporation. TECHNICAL SUPPORT: www.erico.com CFS448_E 4 OF 4 © 2011, 2012, 2013 ERICO International Corporation.