Owner's Manual for Acuity Brands models including: QTP CF DIM Compact Fluorescent Controllable Lighting Systems, QTP CF DIM, Compact Fluorescent Controllable Lighting Systems, Fluorescent Controllable Lighting Systems, Controllable Lighting Systems, Lighting Systems
OSRAM SYLVANIA - RADIOMAG GmbH
File Info : application/pdf, 4 Pages, 508.72KB
DocumentDocumentQUICKTRONIC® HELIOSTM CF UNV Dimming Systems Professional Series Compact Fluorescent Controllable Lighting Systems QTP CF DIM Lamp / Ballast Guide Primary Systems 26W T4 - DULUX D/E, T/E 1 or 2 lamp QTP 2X26CF UNV DIM DM Also operates: 13W T4 - DULUX D/E, T/E (1 or 2 lamps) 18W T4 - DULUX D/E, T/E (1 or 2 lamps) 32W T4 - DULUX T/E (1 lamp) 42W T4 - DULUX T/E (1 lamp) QUICKTRONIC HELIOS CF dual entry dimming ballasts operate DULUX® D/E and T/E lamps with full lumen output and optimal system performance over a wide dimming range (100% to 3%). This ballast features one mounting style of low profile, lightweight enclosures to provide simple assembly for any fixture application. Universal input voltage (120277V) and multi-lamp multi-watt capability allow for fewer SKUs to support a wide range of applications. Key System Features · Universal input voltage (120-277V) · Dual entry, color coded connectors · PROStart® program rapid start ballast · QUICKSENSE® ballast technology · High power factor · Low harmonic distortion · Small size and lightweight · Metal enclosure · UL, CSA, FCC · 100%-3% dimming range · 0-10V control · Anti-flash circuitry - turns on in dimmed mode · RoHS compliant · Lead-free solder and manufacturing process Dual entry, color coded, wire trap connectors located on the side and bottom allow for increased mounting flexibility with one ballast and also increased ease of installation. QUICKTRONIC HELIOS CF ballasts are RoHS compliant and feature lead-free solder and manufacturing process. System Information QUICKTRONIC HELIOS ballasts operate standard low voltage (0-10VDC) controllers making them ideal for applications such as daylight harvesting or building automation applications where standard low voltage devices (0-10VDC, Class 1 or 2) are used to control the lighting system. PROStart programmed rapid start is the optimum starting method, providing up to 100,000 switching cycles for use on occupancy sensors and building control systems. QUICKSENSE® end-of-lamp-life sensing technology helps to protect against overheated bases and sockets, as well as cracking of the glass wall. QUICKSENSE ballast technology uses QTP 2x26CF UNV DIM DM Metal Case Dual Entry Metal with Side & Bottom Mount Capabilities dynamic end-of-lamp-life sensing to avoid false shutdowns caused by some static sensing methods and will auto-reset when the end-of-life lamps are replaced with new ones. A complete System Performance Guide showing performance characteristics of lamps and ballasts is available upon request. SAVINGS Per Year ($) Window / Natural Light Source Application Information QUICKTRONIC CF ballasts are ideally suited for: · Recessed downlights · Wall sconces · Ceiling fixtures · Commercial · Retail, hospitality, institutional · Occupancy sensors · Daylight harvesting · Energy management · Load shedding $20.00 $18.00 SAVINGS PER YEAR* vs LIGHT LEVEL (26W CFL Lamps, QUICKTRONIC QTP HELIOS CFL Ballast) $18.04 $16.00 $14.00 $12.00 $10.00 $9.68 2 Lamp Fixture $8.00 $6.00 $4.00 1 Lamp Fixture $2.00 $0.00 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Light Level *Based on 4000 hrs/yr, $0.11k/Wh, and 120V operation *Savings per Year (@Light Level) = Cost of operation (100% Light Level) Cost of operation (@Light Level) DAYLIGHT HARVESTING SCENARIO Fixture 1 Light Sensor 1 Fixture 2 Light Sensor 2 Fixture 3 Light Sensor 3 Desired Illuminance Er Constant setpoint value Downloaded from Arrow.com. 0-10V CONTROL WIRING LINE SPECIFICATION DATA Catalog # Project Comments Date Type Prepared by 0-10V Dimming Control Wiring for QUICKTRONIC® HELIOSTM Systems Wallbox Style Control Wiring Example 120 or 277V Black (Hot) Neutral (White) 0-10V Dimming Ballasts Wallbox Style Control Wiring Example Black White Violet (+) Pink (-) DIMMING BALLAST 0-10V Class 1 or Class 2 circuit To Fluorescent Lamps Black White Violet (+) Pink (-) DIMMING BALLAST 0-10V To Fluorescent Lamps HELIOS Wiring Examples To Additional Ballasts Black Black 0-10Vdc Wallbox Control with Line Voltage Switch Line Voltage Switch 0-10V Control Violet Pink On/Off Switch (120/277V) Slide Dimmer 0-10V WARNING: Install and wire these ballast and controls in accordance with the National Electrical Code (NEC), all applicable Federal, State and local electrical codes, as well as the specific instructions provided with the 0-10Vdc compatible control that you purchased. Installation should be performed by qualified personnel only. These instructions are guidelines only. Installation may vary for different controls/fixtures/ applications. Be sure to follow the control instructions and all applicable codes and standards when installing dimming systems. Please contact controls manufacturer listed in the controls cross reference for compatible controls and instruction wiring NOTE: HELIOS Dimming ballasts source < 0.5mA (0-10VDC control input) Photo Sensor 0-10V Wiring Example 120 or 277V Black (Hot) Standard Line Voltage Switch Black Neutral (White) 0-10V Dimming Ballasts Photo Sensor 0-10V Wiring Example Black White Violet (+) Pink (-) DIMMING BALLAST 0-10V Class 1 or Class 2 circuit To Fluorescent Lamps Black White Violet (+) Pink (-) DIMMING BALLAST 0-10V To Fluorescent Lamps To Additional Ballasts LINE Violet Pink Photo Sensor 0-10V 0-10V Control Downloaded from Arrow.com. 0-10V CONTROLS SPECIFICATION DATA Catalog # Project Comments Date Prepared by QUICKTRONIC® HELIOSTM 0-10V Controls Information Controls Manufacturer Acuity Brand Controls www.acuitybrandscontrols.com Blue Ridge Technologies www.brtint.com Cooper Greengate http://greengate.coopercontrol.com Encelium www.encelium.com Hunt Dimming www.huntdimming.com Lehigh Electric Products www.lehighdim.com Leviton www.leviton.com Sensor Switch www.sensorswitch.com Siemens Building Technology http://sbt.siemens.com Starfield Controls www.starfieldcorp.com Watt Stopper www.wattstopper.com 0-10 VDC Controls X X X X X X X X X Photo Cell X X X X X X X X Type Occupancy Sensor X X X X X X X X Building Management Systems X X X X X X X X X Please contact controls manufacturers to order/specify controls. For the latest controls list go to www.quicktronic.com Also for more information, refer to the LCA (Lighting Controls Association) site: http://lightingcontrolsassociation.org 0-10 Volt Controls List Controls Guide These 0-10V controls listed to the left operate in conjunction with QUICKTRONIC® PROFESSIONAL HELIOSTM Dimming Electronic Ballast: T5HO Dimming Ballast 49671 QT1x54 120PHO-DIM 49672 QT1x54 277PHO-DIM 49673 QT2x54 120PHO-DIM 49674 QT2x54 277PHO-DIM CF Dimming Ballast 51836 QTP 2x26CF UNV DIM DM Control Specifications/model numbers may change. Please consult manufacturers listed for their latest control models and to order their controls. Downloaded from Arrow.com. QTP CF DIM SPECIFICATION DATA Catalog # Project Comments Date Type Prepared by CF HELIOSTM (0-10V) Professional Series HELIOSTM (0-10V) CF Fluorescent Dimming Systems, UNV (120-277V) Item Number (NAED) Description *2746CP QTP 2x26CF UNV DIM (51836) J20 - 20 pack Input Current (AMPS) 0.44/0.19 0.32/0.14 0.26/0.11 Lamp Type 26W DD/E, DT/E 18W DD/E, DT/E 13W DD/E, DT/E Rated Lumens No. of (lm) Lamps 1800 2 1200 2 900 2 Ballast Factor System (BF) Lumens 1.00 3600 0.03 110 1.00 2400 0.03 70 1.00 1800 0.03 55 Mean Lumens 3095 95 2065 60 1550 45 Input System1 Power Efficacy (W) (lm/W) BEF2 53/53 12/12 38/37 10/10 30/30 8/8 68 1.89 65 2.70 60 3.33 0.39/0.17 42W DT/E 3200 1 1.00 3200 2750 46/46 70 2.17 0.03 95 85 7/7 0.29/0.13 32W DT/E 2400 1 1.00 2400 2065 34/34 71 2.94 0.03 70 60 7/7 0.24/0.11 26W DD/E, DT/E 1800 1 1.00 1800 1550 29/29 62 3.45 0.03 55 45 7/7 0.17/0.08 18W DD/E, DT/E 1200 1 1.00 1200 1030 21/21 57 4.76 0.03 35 30 6/6 0.14/0.07 13W DD/E, DT/E 900 1 1.00 900 775 17/17 53 5.88 0.03 25 20 5/5 NAED in parentheses is provided as a cross reference for the new item number. 1 System Efficacy calculation based on lowest input power value. 2 Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value). Metal M Case 1 Lamp Blue L A Blue M P Red Red BALLAST V Blu Blu P B Y W Y G R R Violet Pink Black White Green Metal M Case 2 Lamp Blue L A M P Blue Yellow Yellow L A M Red P Red BALLAST V Blu P Blu B Y W Y G R R Violet Pink Black White Green Performance Guide QUICKTRONIC CF HELIOS ballasts are compatible with other lamp manufacturers equivalent lamp types that meet ANSI standards. Specifications Starting Method: Programmed Rapid Start Circuit Type: Series Lamp Frequency: >42 kHz Lamp CCF: Less than 1.7 Starting Temp: 50°F/10°C min.3 Input Frequency: 50/60 Hz Low THD: <10% Power Factor: >98% Voltage Range: ±10% of 120-277V UL Listed Class P, Type 1 Outdoor CSA or C/UL Certified 75°C Max Case Temp. (5 yr. warranty) FCC 47CFR Part 18 Non-Consumer Sound Rated A ANSI C62.41 Cat. A Transient Protection Dynamic End-of-Lamp-Life Sensing Remote Mounting (max. wire length from ballast case to lampholder) up to 24 inches. RoHS Compliant4 3 Operation below 50°F (10°C) may affect light output or lamp operation see Low Temperature Starting definition. 4 Complies with European Union Restriction of Hazardous Substances Directive. (Directive 2002/95/EC) Dimensions: Metal case: 4.95" L x 2.93" W x 1.35" H (125mm L x 74mm W x 34mm H) Mounting: Utilize flanges (4.57" L), or (2) #8-32 x 0.375" Long Packaging: Quantity: 20 pieces per case Weight: 1.30 lbs ea. (metal case) Wiring: Push-in connectors (no leads provided) Use 18AWG solid copper wire only Photo Sensor 0-10VDC Wiring Example Standard Line Voltage Switch 120 or 277V Black (Hot) Black Neutral (White) Photo Sensor 0-10V Wiring Example Black White Violet (+) Pink (-) DIMMING BALLAST To Fluorescent Lamps Class 1 or Class 2 circuit Black White Violet (+) Pink (-) DIMMING BALLAST To Fluorescent Lamps To Additional Ballasts LINE Violet Pink Photo Sensor 0-10V 0-10V Control Control Information Dimming Control: 0-10VDC two wire control (10V = full output, 0V = minimum output) QUICKTRONIC HELIOSTM ballasts are compatible with a wide range of 0-10V controllers available from various manufacturers. Low Voltage Control Specs: Ballast will source up to 0.5mA for 0-10VDC control purposes. May be wired as a Class 1 or Class 2 circuit-consult Local and National Electrical Codes. Warranty QUICKTRONIC® Ballasts have a 5-year limited warranty. Complete warranty terms located at www.acuitybrands.com/support/ warranty/terms-and-conditions Item Number QUICKTRONIC PROFESSIONAL Number of Lamps (1, 2) *2746CP QTP 2 x 26 CF UNV DIM System Type - Dimming Line Voltage (120-277V) Primary Lamp Wattage QUICKTRONIC North America 1-877-636-5267 techsupport@quicktronic.com © 2022 Acuity Brands Lighting, Inc. Specifications subject to change without notice. All trademarks referenced are property of their respective owners. Actual performance may differ as a result of end-user environment and application. Direct replacement LED lamps should not be used unless they have been certified for electrical safety, are compatible with the ballast and are suitable for the intended application environment. Only replacement lamps that comply with applicable lamp and ballast manufacturers' ratings, compatibility listings and instructions should be used. ECS440R2 - 4-22 Downloaded from Arrow.com.