User Manual for bas-IP models including: AA-12FB, Outdoor IP Entrance Panel, AA-12FB Outdoor IP Entrance Panel
BAS-IP AA-12FB - Multi-apartment entrance panel
File Info : application/pdf, 8 Pages, 4.34MB
DocumentDocumentUSER MANUAL AA-12FB ENTRANCE PANEL Main features · Panel type: Multi-apartment. · Display: 4.3'' TFT, color with backlight. · Keypad: Backlight piezo buttons. · Camera: 1/4". · Resolution: 2 p. · amera angle: 110° (horizontal). · Output video: Full HD (1920 × 1080), H.264 Main Profile. · Night backlight: 6 LEDs. · Light sensitivity: 0,01 LuX. · Protection class: IP65. · IK-Code: IK07. · Working temperature: -40 -- +65 °. · Power consumption: 6,5 W, in standby -- 3,6 W. · Power supply: +12 V DC. · Body: Aluminum. · Colors: Silver, Gold, Black. · Dimensions for installation: 142 × 358 × 58 mm. · Size of the panel: 161 × 382 × 49 mm. · Installation: Flush, surface with BR-AA12 bracket. ENTRANCE PANEL AA-12FB Full User Manual wiki.bas-ip.com Device description Modern design and well-thought out functionality of this panel makes it an ideal solution for business and elite buildings. AA-12FB is available in gold, silver, and black, and also it supports BAS-IP UKEY mobile access. There is a separate button to call concierge or emergency services. Appearance 1 2 3 4 1 23 i 456 5 7 89 x0 6 1 - Backlight. 2 - Camera. 3 - Loudspeaker. 4 - 4.3'' Display. 5 - Keypad. 6 - Reader. EAN: 5060514912829 (BLACK) EAN: 5060514912836 (SILVER) EAN: 5060514912843 (GOLD) Completeness check of the product Before installation of the outdoor panel, it is necessary to check that it is complete and all components are available. Outdoor panel kit includes: Outdoor panel 1 pc Flush mount bracket 1 pc Manual 1 pc Set of wires with connectors for connection of power supply, lock, and additional modules 1 pc A set of cups 1 pc Set of screws with a wrench 1 pc Electrical connection After verifying the device's completeness, you can switch to the outdoor panel connection. For connection you will need: An Ethernet UTP CAT5 or higher cable connected to a PoE network switch or regular switch/router. Cable length recommendations The maximum length of the UTP CAT5 cable segment should not exceed 100 meters, according to the IEEE 802.3 standard. Power supply at +12 V, 2 amps. Electromagnetic Lock Less Opening lock time adjustment More N.C. GND N.O. Contact Switching Fire alarm 1. +12V contact type: input normally open 2. Ground or normally closed 3. Lock Power + - +12 V Exit button 4. COM 5. N.C./N.O. 6. Unused Output to connect electromechanical lock LAN 1 23 +12V GND Lock Power Wiegand output 1 234 +5V GND D0 D1 1 2345 NC NC COM COM NO Relay outputs to lock RS485 1 234 +12V GND 485+ 485- Exit Button/Door Sensor 1 234 Exit GND Din DS RS232 (Option) Green Black White RX GND TX Connection scheme of electromagnetic lock using uninterruptible power supply UPS-DP/S +12V GND SH-45 Exit Button Door Sensor SH-42 (optional) Electromagnetic Lock DC - + +12V Less Opening lock time adjustment More N.C. GND N.O. Contact Switching Fire alarm 1. +12V contact type: input normally open or normally closed 2. Ground 3. Lock Power + - +12 V Exit button 4. COM 5. N.C./N.O. 6. Unused Output to connect electromechanical lock LAN 1 23 +12V GND Lock Power Wiegand output 1 234 +5V GND D0 D1 1 2345 NC NC COM COM NO Relay outputs to lock RS485 1 234 +12V GND 485+ 485- Exit Button/Door Sensor 1 234 Exit GND Din DS RS232 (Option) Green Black White RX GND TX Connection scheme of electromagnetic lock using third-party power supply for the lock SH-45 Exit Button +12V GND Door Sensor SH-42 (optional) Less Opening lock time adjustment More N.C. GND N.O. Contact Switching Fire alarm 1. +12V contact type: input normally open 2. Ground or normally closed 3. Lock Power + - +12 V Exit button 4. COM 5. N.C./N.O. 6. Unused Output to connect electromechanical lock LAN 1 23 +12V GND Lock Power Wiegand output 1 234 +5V GND D0 D1 1 2345 NC NC COM COM NO Relay outputs to lock RS485 1 234 +12V GND 485+ 485- Exit Button/Door Sensor 1 234 Exit GND Din DS RS232 (Option) Green Black White RX GND TX Electromechanical lock Connection scheme of electromechanical lock using uninterruptible power supply UPS-DP/S Electromechanical lock DC - + +12V SH-45 Exit Button +12V GND Door Sensor SH-42 (optional) Less Opening lock time adjustment More N.C. GND N.O. Contact Switching Fire alarm 1. +12V contact type: input normally open 2. Ground or normally closed 3. Lock Power + - +12 V Exit button 4. COM 5. N.C./N.O. 6. Unused Output to connect electromechanical lock LAN 1 23 +12V GND Lock Power Wiegand output 1 234 +5V GND D0 D1 1 2345 NC NC COM COM NO Relay outputs to lock RS485 1 234 +12V GND 485+ 485- Exit Button/Door Sensor 1 234 Exit GND Din DS RS232 (Option) Green Black White RX GND TX Connection scheme of electromechanical lock using third party power supply for the lock SH-45 Exit Button +12V GND Door Sensor SH-42 (optional) EAN: 5060514912829 (BLACK) EAN: 5060514912836 (SILVER) EAN: 5060514912843 (GOLD) Mechanical mounting Before installation of the outdoor panel it is necessary to provide a hole or a recess into a wall with dimensions 144×360x59 mm (for flush mount) dimensions of the bracket (mounting box) = 142×358×58 mm. It is also necessary to provide supply of a power cable, additional modules and the local network. Attention: the hole at the bottom is designed to drain the water. Do not intentionally close it. Also it is necessary to make a drain for water at the bottom of the niche which will serve to divert water out. 144 mm 360 mm 109-130 cm 1 23 i 456 7 89 x0 Niche Screws Outdoor Panel Outdoor Panel 161 mm 49 mm Flush Bracket 142 mm 358 mm 239 mm 382 mm 1 23 i 456 7 89 x0 Warranty The warranty card number Model name Serial number Seller name With following stated terms of warranty is familiar, functional test was performed in my presence: Customer signature Warranty conditions The warranty period of the product -- 36 (thirty-six) months from the date of sale. Transportation of product must be in its original packaging or supplied one by the seller. The product is accepted in warranty repair only with a properly filled warranty card and the presence of intact stickers or labels. The product is accepted for examination in accordance with the cases provided by law, only in the original packaging, in a full complete set, appearance corresponding to the new equipment and presence of all relevant properly filled documents. This warranty is in addition to the constitutional and other consumer rights and in no way restrict them. Terms of warranty The warranty card must indicate the name of the model, serial number, purchase date, name of the seller, seller company stamp and the customer's signature. Delivery to the warranty repair is carried out by the buyer himself. Warranty repairs carried out only during the warranty period specified in the warranty card. The service center is committed to do everything possible to carry out the repair warranty products, up to 24 working days. The period spent on the restoration of product functionality is added to the warranty period. EAN: 5060514912829 (BLACK) EAN: 5060514912836 (SILVER) EAN: 5060514912843 (GOLD) Notes www.bas-ip.com