Main features
· Panel type: Multi-apartment. · Display: 4.3'' TFT, color with backlight. · Keypad: Backlight piezo buttons. · Camera: 1/4". · Resolution: 2 p. · amera angle: 110° (horizontal). · Output video: Full HD (1920 × 1080), H.264 Main Profile. · Night backlight: 6 LEDs. · Light sensitivity: 0,01 LuX. · Protection class: IP65. · IK-Code: IK07. · Working temperature: -40 -- +65 °. · Power consumption: 6,5 W, in standby -- 3,6 W. · Power supply: +12 V DC. · Body: Aluminum. · Colors: Silver, Gold, Black. · Dimensions for installation: 142 × 358 × 58 mm. · Size of the panel: 161 × 382 × 49 mm. · Installation: Flush, surface with BR-AA12 bracket.

ENTRANCE PANEL

AA-12FB

Full User Manual
wiki.bas-ip.com

Device description

Modern design and well-thought out functionality of this panel makes it an ideal solution for business and elite buildings. AA-12FB is available in gold, silver, and black, and also it supports BAS-IP UKEY mobile access.

There is a separate button to call concierge or emergency services.
Appearance

1 2 3

4

1 23 i

456

5

7 89

x0

6

1 - Backlight. 2 - Camera. 3 - Loudspeaker.

4 - 4.3'' Display. 5 - Keypad. 6 - Reader.

EAN: 5060514912829 (BLACK) EAN: 5060514912836 (SILVER) EAN: 5060514912843 (GOLD)

Completeness check of the product
Before installation of the outdoor panel, it is necessary to check that it is complete and all components are available.

Outdoor panel kit includes:

Outdoor panel

1 pc

Flush mount bracket

1 pc

Manual

1 pc

Set of wires with connectors for connection of power supply, lock, and additional modules

1 pc

A set of cups

1 pc

Set of screws with a wrench

1 pc

Electrical connection
After verifying the device's completeness, you can switch to the outdoor panel connection.

For connection you will need: An Ethernet UTP CAT5 or higher cable connected to a PoE network switch or regular switch/router.
Cable length recommendations The maximum length of the UTP CAT5 cable segment should not exceed 100 meters, according to the IEEE 802.3 standard.
Power supply at +12 V, 2 amps.

Electromagnetic Lock

Less
Opening lock time adjustment
More

N.C.

GND

N.O.

Contact

Switching

Fire alarm 1. +12V

contact type:

input

normally open

2. Ground

or normally closed

3. Lock

Power

+

-

+12 V

Exit button

4. COM
5. N.C./N.O. 6. Unused
Output to connect electromechanical lock

LAN

1 23 +12V GND Lock Power
Wiegand output 1 234
+5V GND D0 D1

1 2345 NC NC COM COM NO Relay outputs to lock
RS485 1 234
+12V GND 485+ 485-

Exit Button/Door Sensor 1 234
Exit GND Din DS

RS232 (Option) Green Black White
RX GND TX

Connection scheme of electromagnetic lock using uninterruptible power supply UPS-DP/S

+12V GND SH-45 Exit Button

Door Sensor

SH-42 (optional)

Electromagnetic Lock

DC
- + +12V

Less
Opening lock time adjustment
More

N.C.

GND

N.O.

Contact

Switching

Fire alarm 1. +12V

contact type:

input

normally open or normally closed

2. Ground

3. Lock

Power

+

-

+12 V

Exit button

4. COM
5. N.C./N.O. 6. Unused
Output to connect electromechanical lock

LAN

1 23 +12V GND Lock Power
Wiegand output 1 234
+5V GND D0 D1

1 2345 NC NC COM COM NO Relay outputs to lock
RS485 1 234
+12V GND 485+ 485-

Exit Button/Door Sensor 1 234
Exit GND Din DS

RS232 (Option) Green Black White
RX GND TX

Connection scheme of electromagnetic lock using third-party power supply for the lock

SH-45 Exit Button

+12V GND

Door Sensor

SH-42 (optional)

Less
Opening lock time adjustment
More

N.C.

GND

N.O.

Contact

Switching

Fire alarm 1. +12V

contact type:

input

normally open

2. Ground

or normally closed

3. Lock

Power

+

-

+12 V

Exit button

4. COM
5. N.C./N.O. 6. Unused
Output to connect electromechanical lock

LAN

1 23 +12V GND Lock Power
Wiegand output 1 234
+5V GND D0 D1

1 2345 NC NC COM COM NO Relay outputs to lock
RS485 1 234
+12V GND 485+ 485-

Exit Button/Door Sensor 1 234
Exit GND Din DS

RS232 (Option) Green Black White
RX GND TX

Electromechanical lock

Connection scheme of electromechanical lock using uninterruptible power supply UPS-DP/S

Electromechanical lock

DC
- + +12V

SH-45 Exit Button

+12V GND

Door Sensor

SH-42 (optional)

Less
Opening lock time adjustment
More

N.C.

GND

N.O.

Contact

Switching

Fire alarm 1. +12V

contact type:

input

normally open

2. Ground

or normally closed

3. Lock

Power

+

-

+12 V

Exit button

4. COM
5. N.C./N.O. 6. Unused
Output to connect electromechanical lock

LAN

1 23 +12V GND Lock Power
Wiegand output 1 234
+5V GND D0 D1

1 2345 NC NC COM COM NO Relay outputs to lock
RS485 1 234
+12V GND 485+ 485-

Exit Button/Door Sensor 1 234
Exit GND Din DS

RS232 (Option) Green Black White
RX GND TX

Connection scheme of electromechanical lock using third party power supply for the lock

SH-45 Exit Button

+12V GND

Door Sensor

SH-42 (optional)

EAN: 5060514912829 (BLACK) EAN: 5060514912836 (SILVER) EAN: 5060514912843 (GOLD)
Mechanical mounting
Before installation of the outdoor panel it is necessary to provide a hole or a recess into a wall with dimensions 144×360x59 mm (for flush mount) dimensions of the bracket (mounting box) = 142×358×58 mm.
It is also necessary to provide supply of a power cable, additional modules and the local network.
Attention: the hole at the bottom is designed to drain the water. Do not intentionally close it. Also it is necessary to make a drain for water at the bottom of the niche which will serve to divert water out.
144 mm

360 mm 109-130 cm

1

23

i

456

7 89

x0

Niche

Screws

Outdoor Panel

Outdoor Panel

161 mm

49 mm

Flush Bracket
142 mm

358 mm
239 mm
382 mm

1 23 i 456 7 89 x0

Warranty
The warranty card number Model name Serial number Seller name
With following stated terms of warranty is familiar, functional test was performed in my presence:
Customer signature
Warranty conditions
The warranty period of the product -- 36 (thirty-six) months from the date of sale.
Transportation of product must be in its original packaging or supplied one by the seller. The product is accepted in warranty repair only with a properly filled warranty card and the presence of intact stickers or labels. The product is accepted for examination in accordance with the cases provided by law, only in the original packaging, in a full complete set, appearance corresponding to the new equipment and presence of all relevant properly filled documents. This warranty is in addition to the constitutional and other consumer rights and in no way restrict them.
Terms of warranty
The warranty card must indicate the name of the model, serial number, purchase date, name of the seller, seller company stamp and the customer's signature. Delivery to the warranty repair is carried out by the buyer himself. Warranty repairs carried out only during the warranty period specified in the warranty card. The service center is committed to do everything possible to carry out the repair warranty products, up to 24 working days. The period spent on the restoration of product functionality is added to the warranty period.

EAN: 5060514912829 (BLACK) EAN: 5060514912836 (SILVER) EAN: 5060514912843 (GOLD)
Notes

www.bas-ip.com



References

Corel PDF Engine Version 21.3.0.755 CorelDRAW 2019