Instruction Manual for PPI models including: HumiTherm-i, HumiTherm-i Temperature Humidity Indicator, Temperature Humidity Indicator, Humidity Indicator
Parameters Settings (Default Value) Operation Manual This brief manual is primarily meant for quick reference to wiring connections and parameter searching.
Composite Temperature & Humidity Indicator With Alarms
28 feb 2022 — Operation Manual. This brief manual is primarily meant for quick reference to wiring connections and parameter searching. For more details on operation and ...
File Info : application/pdf, 4 Pages, 1.21MB
DocumentDocumentHumiTherm-i Composite Temperature + Humidity Indicator Version : RTD Pt100, 3-wire for Temperature DC Linear (Voltage) for Humidity ALARM PARAMETERS FOR TEMPERATURE: PAGE-10 Parameters Settings (Default Value) Temperature Alarm Type None Process Low Temperature Alarm Setpoint Temperature Alarm Hysteresis Process High (Default : None) -50.0 to 150.0°C or -58.0 to 302.0°F (Default : For Process Low : -50.0 For Process High : 150.0) 0.1 to 25.0 °C or °F (Default : 0.2) Temperature Alarm Logic Temperature Alarm Inhibit Direct Reverse (Default : Direct) No Yes (Default : Yes) ALARM PARAMETERS FOR RELATIVE HUMIDITY: PAGE-11 Parameters Settings (Default Value) Alarm Type None Process Low Process High (Default : None) %RH Alarm Setpoint 0.0 to 100.0% (Default : For Process Low : 0.0 For Process High : 100.0) %RH Alarm Hysteresis 0.1 to 25.0% (Default : 0.2) %RH Alarm Logic Direct %RH Alarm Inhibit Reverse (Default : Direct) No Yes (Default : Yes) Operation Manual This brief manual is primarily meant for quick reference to wiring connections and parameter searching. For more details on operation and application; please log on to www.ppiindia.net ZERO-OFFSET PARAMETERS: PAGE-12 Parameters Settings (Default Value) Zero Offset for Temp. Value -25.0 to +25.0°C (Default : 0.0) Zero Offset for %RH Value -25.0 to +25.0% (Default : 0.0) SUPERVISORY PARAMETERS: PAGE-13 Parameters Settings (Default Value) Unit Selection for Temperature °C °F (Default : °C) Dry-Bulb Temperature and % RH Min / Max No Monitoring Yes (Default : No) Password For Resetting PV High - Low 0 to 250 (Default : 0) Baud Rate ID Number for Temperature Loop ID Number for RH Loop (Default : 4800) 1 to 8 (Default : 1) 1 to 8 (Default : 2) OPERATOR PAGE AND PARAMETERS : PAGE - 0 Parameters Settings (Default Value) Maximum Dry Bulb Temperature Value View Only Minimum Dry - Bulb Temperature Value View Only Maximum %RH Value Minimum Peak of RH Reset Command Reset Pass - Code View Only View Only No Yes (Default : No) 0 to 250 (Default : 0) FRONT PANEL LAYOUT Front Panel PPI HumiTherm-i °C Upper Readout %RH Lower Readout Alarm -1 Indicator AL1 AL2 Alarm-2 Indicator PAGE Key ENTER Key DOWN Key UP Key 101, Diamond Industrial Estate, Navghar, Vasai Road (E), Dist. Palghar - 401 210. Sales : 8208199048 / 8208141446 Support : 07498799226 / 08767395333 E: sales@ppiindia.net, support@ppiindia.net Symbol Key Keys Operation Function PAGE Press to enter or exit set-up mode. DOWN UP ENTER Press to decrease the parameter value. Pressing once decreases the value by one count; keeping pressed speeds up the change. Press to increase the parameter value. Pressing once increases the value by one count; keeping pressed speeds up the change. Press to store the set parameter value and to scroll to the next parameter on the PAGE. PV Error Indications Message PV Error Type Over-range (Dry-Bulb Temp. above Max. Range) Under-range (Dry-Bulb Temp. below Min. Range) Open (Sensor open / broken) Jan 2022 + + ELECTRICAL CONNECTIONS SSR NC C NO RELAY OUTPUT 1 VAC SUPPLY RS 485 85~264 _ OUTPUT 2 NC C NO RELAY _ SSR + 6 7 8 9 10 GND NL 5 11 4 PPI 12 3 HumiTherm-i 13 2 14 1 18 17 16 15 Ex - + RH SENSOR INPUT 2 SERIAL COMM. INPUT 1 Pt100 OUTPUT1 RELAY SSR INPUT1 Pt100 ENCLOSURE ASSEMBLY `UP' inscribed on topside _ UP UP + COSMERMISA.L SUPPLY N/O C + N/C 6 5 4 NO_/UCTPCUNT/2O 7 8 9 RSSERLA Y 3 2 1 H18uPmiTPheIrm-i Ex IN 17 PUT 16 2 10 11 GND 12 13 14 L N 15 AC DC RHSENSOR Removal Bezel Placing Back PPI HumiTherm-i °C %RH AL2 AL1 Pullout Grip Front Label JUMPER SETTINGS OUTPUT-1 Output Type Jumper Setting - A Jumper Setting - B 3 Relay 2 1234 1 3 SSR Voltage Pulses 2 1234 1 3 2 1 B A1 2 3 4 Pins Hum iTherm -i P P I Link JUMPER SETTINGS OUTPUT-2 Output Type Jumper Setting - A Jumper Setting - B Relay SSR Voltage Pulses MOUNTING DETAILS OUTPUT-2 MODULE HumiTherm-i MOUNTING DETAILS SERIAL COMM. MODULE Power Supply Board Serial Communication Module Plug & Socket Connectors Jumper Setting-B PPI -i iTherm Hum Jumper Setting-A Front Label Upside-down HumiTherm-i Composite Temperature + Humidity Indicator Version : RTD Pt100, 3-wire Dry Bulb for Temperature & RTD Pt100, 3-wire Wet Bulb for Humidity Operation Manual This brief manual is primarily meant for quick reference to wiring connections and parameter searching. For more details on operation and application; please log on to www.ppiindia.net ALARM PARAMETERS FOR TEMPERATURE : PAGE 10 Parameters Settings (Default Value) Alarm Type None Process Low Alarm Setpoint Alarm Hysteresis Process High (Default : None) -50.0 to 150.0°C or -58.0 to 302.0°F (Default : For Process Low : -50.0 For Process High : 150.0) 0.1 to 25.0 °C or °F (Default : 0.2) Alarm Logic Direct Alarm Inhibit Reverse (Default : Direct) No Yes (Default : Yes) ALARM PARAMETERS FOR RELATIVE HUMIDITY : PAGE 11 Parameters Settings (Default Value) Alarm Type None Alarm Setpoint Alarm Hysteresis Process Low Process High (Default : None) 0.0 to 100.0% (Default : For Process Low : 0.0 For Process High : 100.0) 0.1 to 25.0% (Default : 0.2) Alarm Logic Alarm Inhibit Direct Reverse (Default : Direct) No Yes (Default : Yes) ZERO-OFFSET PARAMETERS : PAGE 12 Parameters Settings (Default Value) Zero Offset for Dry Bulb Temp. -25.0 to +25.0°C (Default : 0.0) Zero Offset for Wet Bulb Temp. -25.0 to +25.0°C (Default : 0.0) Zero Offset for RH Value -25.0 to +25.0% (Default : 0.0) UTILITY PARAMETERS : PAGE 13 Parameters Settings (Default Value) Unit Selection for PV °C Dry-Bulb Temperature and % RH High-Low Monitoring Password For Resetting PV High - Low °F (Default : °C) No Yes (Default : No) 0 to 250 (Default : 0) Baud Rate ID for Temperature Loop ID for %RH Loop (Default : 4800) 1 to 8 (Default : 1) 1 to 8 (Default : 2) FRONT PANEL LAYOUT Front Panel PPI HumiTherm-i °C Upper Readout Lower Readout Alarm -1 Indicator PAGE Key %RH AL1 AL2 Alarm-2 Indicator ENTER Key DOWN Key UP Key Symbol Key Keys Operation Function PAGE Press to enter or exit set-up mode. DOWN Press to decrease the parameter value. Pressing once decreases the value by one count; keeping pressed speeds up the change. UP ENTER Press to increase the parameter value. Pressing once increases the value by one count; keeping pressed speeds up the change. Press to store the set parameter value and to scroll to the next parameter on the PAGE. PV Error Indications Message PV Error Type Over-range (Dry-Bulb Temp. above Max. Range) Under-range (Dry-Bulb Temp. below Min. Range) Open (RTD Pt100 (Dry Bulb) Sensor open / broken) OUTPUT 1 RELAY SSR 101, Diamond Industrial Estate, Navghar, Vasai Road (E), Dist. Palghar - 401 210. Sales : 8208199048 / 8208141446 Support : 07498799226 / 08767395333 E: sales@ppiindia.net, support@ppiindia.net ELECTRICAL CONNECTIONS OUTPUT 2 N/C C N/O RELAY _ + SSR N/O + 6 7 8 9 10 GND C 5 11 N/C _ 4 PPI 12 L AC 3 HumiTherm-i 13 N DC 2 14 1 18 17 16 15 INPUT 1 Pt100 Pt100 INPUT 2 SERIAL COMMS. SUPPLY Jan 2022 JUMPER SETTINGS OUTPUT-1 MOUNTING DETAILS OUTPUT-2 MODULE Output Type Jumper Setting - A Jumper Setting - B 3 Relay 2 1234 1 3 SSR Voltage Pulses 2 1234 1 Link P P I Hum iTherm -i 3 2 1 B A1 2 3 4 Pins HumiTherm-i OUTPUT1 RELAY SSR ENCLOSURE ASSEMBLY `UP' inscribed on topside _ UP UP + COSMERMISA.L SUPPLY N/O C + N/C 6 5 4 NO_/UCTPCUNT/2O 7 8 9 + RSSERLA Y 3 2 1 PPI 1H8umiTherm-i Ex IN 17 PUT 16 2 10 11 GND 12 13 14 L N 15 AC DC RHSENSOR Removal Bezel Placing Back PPI HumiTherm-i °C %RH AL2 AL1 Pullout Grip Front Label JUMPER SETTINGS OUTPUT-2 Output Type Jumper Setting - A Relay Jumper Setting - B SSR Voltage Pulses MOUNTING DETAILS SERIAL COMM. MODULE Power Supply Board Serial Communication Module Plug & Socket Connectors Jumper Setting-B PPI Jumper Setting-A -i iTherm Hum Front Label Upside-down INPUT1 Pt100