Datasheet for MEAN-WELL models including: DDR-480B-12, DDR-480B-24, DDR-480B-48, DDR-480C-12, DDR-480C-24, DDR-480C-48, DDR-480D-12, DDR-480D-24, DDR-480D-48, DDR-480B-12 480W DIN Rail Type DC DC Converter, DDR-480B-12, 480W DIN Rail Type DC DC Converter, Rail Type DC DC Converter, Type DC DC Converter, DC Converter, Converter

MEAN-WELL USA, INC. - РКС Компоненти - РАДІОМАГ


File Info : application/pdf, 9 Pages, 296.75KB

PDF preview unavailable. Download the PDF instead.

ddr-480-spec
480W DIN Rail Type DC-DC Converter

DDR-480 series
User's Manual

IEC62368-1

UL62368-1 AS/NZS62368-1 TPTC004

 Features

 Applications

Compliance to BS EN/EN50155 and BS EN/EN45545-2 railway standard Width only 85.5mm 2:1 wide input range -40~+80 wide operating temperature 150% peak load capability Current sharing up to 1920W(3+1) DC output adjustable Cooling by free air convection Can be installed on DIN rail TS-35/7.5 or 15 Protections: Short circuit / Overload / Over voltage /
Over temperature / Input reverse polarity/ Input under voltage protection 4KVdc I/O isolation(Reinforced isolation) DC OK relay contact Remote ON-OFF control Operating attitude up to 5000 meters(Note.6) 3 years warranty

Bus,tram,metro or railway system Industrial control system Semi-conductor fabrication equipment Factory automation Electro-mechanical Wireless network Telecom or datacom system
 GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx

 Description

DDR-480 series is a 480W DIN Rail type DC-DC converter with main features including DIN rail-type easy

installation, ultra slim width (85.5mm), 2:1 wide input voltage, fanless design, -40~+80 wide operating

temperature, 4KVdc I/O isolation, 150% peak load, current sharing,DC OK, adjustable output voltage

and full protective functions. This series of models has various input options: 16.8~33.6V / 33.6~67.2V /

67.2~154V and multiple output options: 12V / 24V / 48V and can be used for industrial & railway control,

security control, communication system and other fields. Suitable applications include to DC buck/boost

regulator, increasing system insulation level and voltage drop compensation along cable...etc.

 Model Encoding DDR - 480 B - 24

Downloaded from Arrow.com.

Output voltage(12/24/48Vdc) Input voltage (B:16.8~33.6Vdc, C:33.6~67.2Vdc, D:67.2~154Vdc) Rated wattage Series name
File Name:DDR-480-SPEC 2023-01-16

480W DIN Rail Type DC-DC Converter

DDR-480 series

SPECIFICATION

MODEL

DDR-480B-12 DDR-480B-24 DDR-480B-48 DDR-480C-12 DDR-480C-24 DDR-480C-48 DDR-480D-12 DDR-480D-24 DDR-480D-48

OUTPUT INPUT

DC VOLTAGE

12V

24V

48V

12V

24V

48V

12V

24V

48V

RATED CURRENT

33.4A

20A

10A

33.4A

20A

10A

33.4A

20A

10A

CURRENT RANGE

0 ~ 33.4A 0 ~ 20A

0 ~ 10A

0 ~ 33.4A 0 ~ 20A

0 ~ 10A

0 ~ 33.4A 0 ~ 20A

0 ~ 10A

RATED POWER

400.8W

480W

480W

400.8W

480W

480W

400.8W

480W

480W

PEAK

CURRENT 5sec. 50.1A

30A

15A

50.1A

30A

15A

50.1A

30A

15A

Note.5 POWER 5sec. 12Vo: 601.2W, 24Vo / 48Vo : 720W

RIPPLE & NOISE (max.) Note.2 100mVp-p 120mVp-p 150mVp-p 100mVp-p 120mVp-p 150mVp-p 100mVp-p 120mVp-p 150mVp-p

VOLTAGE ADJ. RANGE

12 ~ 14V 24 ~ 28V 48~ 56V 12 ~ 14V 24 ~ 28V 48~ 56V 12 ~ 14V 24 ~ 28V 48~ 56V

VOLTAGE TOLERANCE Note.3 ±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

LINE REGULATION

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

LOAD REGULATION

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

SETUP, RISE TIME

500ms, 60ms

HOLD UP TIME (Typ.)

Please refer to page 6 hold up time (Load de-rating curve )

VOLTAGE CONTINUOUS RANGE
Note.4 100ms

EFFICIENCY (Typ.)

90%

16.8 ~ 33.6Vdc

14.4 ~ 16.8Vdc

91%

90.5%

33.6 ~ 67.2Vdc

28.8 ~ 33.6Vdc

91%

92%

92%

67.2 ~ 154Vdc

66 ~ 67.2Vdc

91%

92%

93%

DC CURRENT (Typ.)

23A @24Vdc

11.2A @48Vdc

5A @110Vdc

INRUSH CURRENT (Typ.) 30A

INTERRUPTION OF VOLTAGE SUPPLY EN50155: 2017-B/C/D type comply with S2 level (10ms)@ full load

OVERLOAD

Normally works within 150% rated output power for more than 5 seconds and then constant current protection 105~135% rated Note.5 output power with auto-recovery

OVER VOLTAGE PROTECTION
OVER TEMPERATURE REVERSE POLARITY

14.4 ~ 17.5V 28.8 ~ 35V 57.6 ~ 65V 14.4 ~ 17.5V 28.8 ~ 35V 57.6 ~ 65V 14.4 ~ 17.5V 28.8 ~ 35V Protection type : Shut down o/p voltage, re-power on to recover Shut down o/p voltage, re-power on to recover By internal, MOSFET, no damage, recovers automatically after fault condition is removed

57.6 ~ 65V

UNDER VOLTAGE LOCKOUT

24Vin (B - type) :Power ON16.8V , OFF16.5V

48Vin (C - type) :Power ON33.6V , OFF33V

110Vin (D - type):Power ON67.2V , OFF65V

DC OK REALY CONTACT RATINGS (max.) 30Vdc/1A resistive load

FUNCTION CURRENT SHARING

Up to 1920W (3+1 units). Please refer to the Function Manual

REMOTE ON-OFF CONTROL Please refer to the Function Manual

WORKING TEMP.

-40 ~ +80 (Refer to "Derating Curve")

WORKING HUMIDITY

5 ~ 95% RH non-condensing

ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 5 ~ 95% RH non-condensing

TEMP. COEFFICIENT VIBRATION

±0.03%/ (0 ~ 55) Component:10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC61373

OPERATING ALTITUDE Note.6 5000 meters / OVC

SAFETY STANDARDS

UL 62368-1, IEC 62368-1, AS/NZS 62368-1, EAC TP TC 004 approved

WITHSTAND VOLTAGE

I/P-O/P:4KVdc I/P-FG:2.5KVdc O/P-FG:0.71KVdc

ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500Vdc / 25/ 70% RH

Parameter

Standard

Test Level / Note

Conducted

BS EN/EN55032 (CISRP32) Class A

EMC EMISSION
SAFETY & EMC (Note 7)

Radiated Voltage Flicker Harmonic Current BS EN/EN55035 Parameter

BS EN/EN55032 (CISRP32) BS EN/EN61000-3-3 -----

Class B -----
-----

Standard

Test Level / Note

ESD

BS EN/EN61000-4-2

Level 3, 8KV air ; Level 3, 6KV contact; criteria A

EMC IMMUNITY

Radiated EFT / Burst

BS EN/EN61000-4-3 BS EN/EN61000-4-4

Level 3, 10V/m ; criteria A Level 3, 2KV ; criteria A

Surge

BS EN/EN61000-4-5

Level 3, 1KV/Line-Line ;Level 3, 2KV/Line-Line-FG ;criteria A

Conducted

BS EN/EN61000-4-6

Level 3, 10V ; criteria A

Magnetic Field

BS EN/EN61000-4-8

Level 4, 30A/m ; criteria A

RAILWAY STANDARD

Compliance to BS EN/EN45545-2 for fire protection ; Meet BS EN/EN50155 / IEC60571 including IEC61373 for shock & vibration, BS EN/EN50121-3-2 for EMC

MTBF

750.3K hrs min. Telcordia SR-332 (Bellcore) ; 101.7K hrs min. MIL-HDBK-217F (25)

OTHERS DIMENSION

85.5*125.2*129.2mm (W*H*D)

PACKING

1.375Kg;8pcs/12Kg/0.95CUFT

1. All parameters NOT specially mentioned are measured at normal input (B:24Vdc , C:48Vdc , D:110Vdc ) , rated load and 25 of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1f & 47f parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation.

NOTE

4. Derating may be needed under low input voltage. Please check the derating curve for more details. 5. 150% 5 seconds, please refer to peak loading curves.

6. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than2000m(6500ft).

7. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with

the EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.

(as available on http://www.meanwell.com)

 Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Downloaded from Arrow.com.

File Name:DDR-480-SPEC 2023-01-16

480W DIN Rail Type DC-DC Converter Block Diagram

+Vi DC I/P
-Vi

INPUT FUSE

EMI FILTER

POWER SWITCHING

FG

O.L.P.

PWM CONTROL

ON/OFF

Remote Control

Derating Curve

150 For 5 sec. (typ.)
100 Continuous For others
For DDR-480B/C/D-12 & DDR-480D-24/48 40

-40

-20

0

20

40 55 60

80

(VERTICAL)

AMBIENT TEMPERATURE ()

Output derating VS Input Voltage

100

90

80

C/D Type

70

B Type

60

50

40

LOAD (%)

B Type: 16.8

21.6

33.6

C Type: 33.6

43.2

67.2

D Type: 67.2

86.4

154

INPUT VOLTAGE (V)

DDR-480 series

RECTIFIERS &
FILTER
O.V.P.
DETECTION CIRCUIT
CURRENT SHARE

fosc : 65KHz DC OK +Vo -Vo
P+ P-

File Name:DDR-480-SPEC 2023-01-16

LOAD (%)

Downloaded from Arrow.com.

480W DIN Rail Type DC-DC Converter

DDR-480 series

Peak Loading
601.2W for 12Vo 720W for others (150% load)

400.8W for 12Vo 480W for others (100% load)

100 sec.

5 sec.

DC OK Relay Contact

Contact Close Contact Open Contact Ratings (max.)

PSU turns on / DC OK. PSU turns off / DC Fail. 30V/1A resistive load.

Function Manual
1. Current sharing (1) Parallel operation is available by connecting the units shown as below (P+,P- are connected mutually in parallel) : (2) The voltage difference among each output should be minimized that less than 0.2V is required. (3) The total output current must not exceed the value determined by the following equation (Output current at parallel operation) =(The rated current per unit) x (Number of unit) x 0.9. (4) In parallel operation 4 units is the maximum, please consult the manufacture for other applications. (5) When in parallel operation, the minimum output load should be greater than 3% of total output load. (Min. load > 3% rated current per unit x number of unit)

+

-

LOAD

+Vo -Vo

P+ P-

DC OK

DC OK Vo Adj. +

PSU1

+Vo -Vo

P+ P-

DC OK

DC OK Vo Adj. +

PSU2

+Vo -Vo

P+ P-

DC OK

DC OK Vo Adj. +

PSU3

2. Remote ON-OFF Control  The power supply can be turned ON-OFF by using the "Remote ON-OFF" function.

Remote ON-OFF (TB1 PIN2,4) Open or 5.5 ~ 10VDC Short or 0 ~ 0.8VDC

Output Status
power supply ON power supply OFF

Downloaded from Arrow.com.

+Vo -Vo

P+ P-

DC OK

DC OK Vo Adj. +

PSU4

File Name:DDR-480-SPEC 2023-01-16

480W DIN Rail Type DC-DC Converter

DDR-480 series

Input Fuse

There is one fuse connected in series to the positive input line, which is used to protect against abnormal surge. Fuse specifications of each model are shown as below.

Type

Fuse Type

B

Time-Lag

C

Time-Lag

D

Time-Lag

Reference and Rating Conquer MST, 10A, 250V *5 Conquer MST, 8A, 250V *3 Conquer MST, 6.3A, 250V *2

Input Under-Voltage Protection
If input voltage drops below Vimin, the internal control IC shuts down and there is no output voltage. It recovers automatically when input voltage reaches above Vimin,please refer to the cruve below.

DDR-480B-24
Vo 30 25

DDR-480C-24
Vo 30 25

DDR-480D-24
Vo 30 25

Turn On Turn Off

20

20

20

15

15

15

10

10

10

5

16.5 16.8

0

Vin

15 16 17 18 19 20

5

33

33.6

0

Vin

31 33 34 35 36 37

5

65

67.2

0

Vin

65 66 67 68 69 70

Input Reverse Polarity Protection
There are two MOSFETs connected in series to the negative input line. If the input polarity is connected reversely, the MOSFETs open and there will be no output to protect the unit.
Inrush Current
Inrush current is suppressed by a resistor during the initial start-up, and then the resistor is bypassed by MOSFETs to reduce power consumption after accomplishing the start-up.
Inrush current limit Power start Normal current

Downloaded from Arrow.com.

File Name:DDR-480-SPEC 2023-01-16

480W DIN Rail Type DC-DC Converter

DDR-480 series

Hold-up Time

EN50155:2017 version- B/C/D type comply with S2 level (10ms) @ full load , please refer to the table and curves show below for the hold up time specification.

Model

Load

B type (24Vin)

100% load 10ms min.

70% load 16ms min.

other load figure 1,2,3

C type (48Vin)

11ms min. 17ms min.

figure 4,5,6

D type (110Vin) 16ms min.

24ms min.

figure 7,8,9

LOAD

LOAD

LOAD

DDR-480B-12

100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0%
0ms

10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms 90ms 100ms 110ms 120ms 130ms 140ms

TIME

figure 1

DDR-480B-48

100%

90%

80%

70%

60%

50%

40%

30%

20%

10%

0% 0ms

10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms 90ms 100ms 110ms 120ms

TIME

figure 3

DDR-480C-24

100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0%
0ms

10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms 90ms 100ms 110ms 120ms

TIME

figure 5

DDR-480D-12

100%

90%

80%

70%

60%

50%

40%

30%

20%

10%

0% 0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms 90ms 100ms 110ms 12 0ms 130ms 140ms 150ms 160ms 170ms 180ms 190ms

TIME

figure 7

DDR-480D-48

100%

90% 80%

70%

60%

50%

40%

30%

20%

10%

0%
0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms 90ms 100ms 110ms 120ms 130ms 140ms 150ms 160ms

TIME

figure 9

LOAD

LOAD

LOAD

LOAD

DDR-480B-24

100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0%
0ms

10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms 90ms 100ms 110ms 120ms

TIME

figure 2

DDR-480C-12

100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0%
0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms 90ms 100ms 110ms 120ms 130ms 140ms 150ms 160ms

TIME

figure 4

DDR-480C-48

100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0%
0ms

10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms 90ms 100ms 110ms 120ms 130ms

TIME

figure 6

DDR-480D-24

100%

90%

80%

70%

60%

50%

40%

30%

20%

10%

0%
0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms 90ms 100ms 110ms 120ms 130ms 140ms 150ms 160ms

TIME

figure 8

File Name:DDR-480-SPEC 2023-01-16

LOAD

LOAD

Downloaded from Arrow.com.

480W DIN Rail Type DC-DC Converter

DDR-480 series

Efficiency vs Load & Vin Curve
The efficiency vs load & Vin curves of each model are shown as below.

EFFICIENCY

EFFICIENCY

EFFICIENCY

DDR-480B-12
95% 90% 85% 80% 75% 70%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
DDR-480B-48
95% 90% 85% 80% 75% 70%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
DDR-480C-24
95%
90%
85%
80%
75%
70% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD

154Vdc 110Vdc 67.2Vdc
33.6Vdc 24Vdc 16.8Vdc
67.2Vdc 48Vdc 33.6Vdc

DDR-480D-12
95%
90%
85%
80%
75%
70% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
DDR-480D-48
95% 90% 85% 80% 75% 70%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD

48Vdc 67.2Vdc 33.6Vdc
154Vdc 110Vdc 67.2Vdc

EFFICIENCY

EFFICIENCY

EFFICIENCY

EFFICIENCY

DDR-480B-24
95% 90% 85% 80% 75% 70%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
DDR-480C-12
95% 90% 85% 80% 75% 70%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD

33.6Vdc 24Vdc 16.8Vdc
24Vdc 33.6Vdc 16.8Vdc

DDR-480C-48
95%
90%
85%
80%
75%
70% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD

62.4Vdc 48Vdc 33.6Vdc

DDR-480D-24
95%
90%
85%
80%
75%
70% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD

154Vdc 110Vdc 67.2Vdc

EFFICIENCY

EFFICIENCY

File Name:DDR-480-SPEC 2023-01-16

Downloaded from Arrow.com.

480W DIN Rail Type DC-DC Converter

DDR-480 series

Immunity to Environmental Conditions

Test method Cooling Test Dry Heat Test Damp Heat Test, Cyclic Vibration Test
Increased Vibration Test Shock Test

Standard

Test conditions

EN 50155 section 12.2.3 (Column 2, Class TX) EN 60068-2-1

Temperature: -40 Dwell Time: 2 hrs/cycle

EN 50155 section 12.2.4 (Column 2, Class TX) EN 50155 section 12.2.4 (Column 3, Class TX & Column 4, Class TX) EN 60068-2-2

Temperature: 70 / 85 Duration: 6 hrs / 10min

EN 50155 section 12.2.5 EN 60068-2-30

Temperature: 25~55 Humidity: 90%~100% RH Duration: 48 hrs

EN 50155 section 12.2.11 EN 61373

Temperature: 19 Humidity: 65% Duration: 10 mins

EN 50155 section 12.2.11 EN 61373

Temperature: 19 Humidity: 65% Duration: 5 hrs

EN 50155 section 12.2.11 EN 61373

Temperature: 21± 3 Humidity: 65 ± 5% Duration: 30ms*18

Status No damage
PASS PASS PASS
PASS PASS

Low Temperature Storage Test

EN 50155 section 12.2.3 (Column 2, Class TX) EN 60068-2-1

Temperature: -40 Dwell Time: 16 hrs

PASS

Salt Mist Test

EN 50155 section 12.2.10 (Class ST4)

Temperature: 35±2 Duration: 48 hrs

PASS

EN45545-2 Fire Test Conditions

Test Items Items

Standard

Oxygen index test

EN 45545-2:2013 EN ISO 4589-2:1996

R22

Smoke density test

EN 45545-2:2013 EN ISO 5659-2:2006

Smoke toxicity test

EN 45545-2:2013 NF X70-100:2006

R24

Oxygen index test

EN 45545-2:2013 EN ISO 4589-2:1996

R25 Glow-wire test

EN 45545-2:2013 EN 60695-2-11:2000

R26

Vertical flame test

EN 45545-2:2013 EN 60695-11:2003

Hazard Level

HL1

HL2

HL3

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

Downloaded from Arrow.com.

File Name:DDR-480-SPEC 2023-01-16

36 125.2

480W DIN Rail Type DC-DC Converter Mechanical Specification

129.2 Side View

Top View 1234 567 8 TB2
DC OK DC OK Vo Adj. +
123 4 TB1
Front View

Installation Instruction

85.5 Bottom View

DDR-480 series

Case No. 984F

Unit:mm

Terminal Pin No. Assignment (TB2) Pin No. Assignment 1,2 DC output +Vo 3,4 DC output -Vo 5,6 DC OK Relay Contact 7,8 P+,P-(Current sharing)

Side View
Terminal Pin No. Assignment (TB1) Pin No. Assignment 1 FG 2 DC input -Vin 3 DC input +Vin 4 Remote ON/OFF

This series fits DIN rail TS35/7.5 or TS35/15. For installation details, please refer to the Instruction manual.

35

ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15
(For reference only. Not included with unit.)

Back View
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
Downloaded from Arrow.com.

File Name:DDR-480-SPEC 2023-01-16

