User Manual: Robe Ambiane AP Lighting Fixture

The Ambiane AP unit generates light using high-power LEDs and is designed exclusively for indoor use.

1. Attention & Safety Precautions

Installation must be performed by a qualified electrician, adhering to all national and local electrical and construction codes and regulations.

The equipment's immunity is designed for electromagnetic environments E1, E2, E3 as per EN55103-2 ed.2 (Electromagnetic compatibility). It is part of a product family standard for professional audio, video, audiovisual, and entertainment lighting control apparatus.

The product, including covers and cables, must not be exposed to high-frequency electromagnetic fields exceeding 3V/m.

Installation companies should assess potential interference levels in the installation area before deployment.

Equipment emissions comply with EN55032 Electromagnetic compatibility of multimedia equipment – Emission Requirements, Class B.

Mounting Requirements:

Always switch off the power supply before connecting or disconnecting the unit. ⚡

2. Installation Guide

Follow these steps for installing the Ambiane AP unit:

  1. Prepare a circular opening in the ceiling with a diameter of 212 mm (+2/-0) and a depth of 5-45 mm.
  2. Insert the Ambiane AP unit into the prepared opening.
  3. Fasten the unit securely using the two integrated spring fasteners.
  4. Connect the necessary cables to the Ambiane AP. Connection blocks are located on the main PCB (RB 3727), protected by a plastic cover secured with screws.

Power Supply:

Control Options: The Ambiane AP supports DMX 512, DALI, and 0-10V control (0-10V is applicable to Ambiane PW and Ambiane TD models only).

The unit is equipped with dual DMX and DALI connection blocks to facilitate easy daisy-chaining (In/Out method).

3. DMX and DALI Address Setting & Control

The unit is equipped with a DIP switch (7) for test light functionality and software update mode selection.

DMX Control:

The DMX start address, the first channel for DMX controller input, can range from 1 to 509. Addresses can be set via DIP switch or RDM; RDM settings override DIP switch settings and vice versa. The green LED (8) on the PCB indicates the address setting method: LED ON signifies DIP switch setting, while LED OFF indicates RDM setting. DIP 11 must be in the OFF position for DMX control.

Example DMX Address Settings (DIP Switch Configuration):

DALI Control:

Addressing is managed by an external DALI controller. To initiate permanent DALI control (disabling DMX), send the activating command (8=ON). To stop control, send the deactivating command (0=OFF). DIP 11 must be in the OFF position.

Control Mode Switching: When DIP 11 is OFF, the first command received (DMX or DALI) determines the active mode. For continuous DALI operation, send DALI command 8.

0-10V Control:

Set DIP 11 to the ON position. This mode has priority over DALI commands and is available for Ambiane PW and Ambiane TD models only.

4. RDM (Remote Device Management)

The Ambiane AP supports RDM, a bi-directional communication protocol for DMX512 systems, facilitating device configuration and status monitoring.

RDM enables setting DMX addresses, selecting DMX modes, and retrieving software versions.

DMX Signal Loss Behavior Configuration via RDM:

The RDM Model ID for the Ambiane AP is 0x0114.

RDM Parameters:

Parameter ID Discovery Command SET Command GET Command
DISC_UNIQUE_BRANCH**
DISC_MUTE**
DISC_UN_MUTE**
DEVICE_INFO**
SUPPORTED_PARAMETERS**
SOFTWARE_VERSION_LABEL**
DMX_START_ADDRESS***
IDENTIFY_DEVICE***
DEVICE_MODEL_DESCRIPTION**
MANUFACTURER_LABEL**
DEVICE_LABEL**
SENSOR_DEFINITION**
SENSOR_VALUE**
RESET_DEVICE***
DMX_PERSONALITY***
DMX_PERSONALITY_DESCRIPTION**
SENSOR_VALUE**
SENSOR_DEFINITION**

5. Anti-glare Ring Installation

Insert the anti-glare ring (1) into the Ambiane AP. Ensure it clicks into place by engaging the three locks (2) with the corresponding slots (3).

6. Adapter Ring Installation

  1. Remove the two spring fasteners (2) by unscrewing the four M4x10 screws (1).
  2. Slide the adapter ring (4) onto the housing of the Ambiane AP.
  3. Secure the adapter ring using the new fasteners (3), utilizing the original M4x10 screws (1).

7. DMX Protocols

Detailed DMX channel configurations and functions for various Ambiane AP models.

Ambiane RGBW, Ambiane RGBA (Version 1.2)

Mode 1 Channel Mode 2 Channel Mode 3 Channel Mode 4 Channel Mode 5 Channel Value Function Type of Control
1111-0-255Red LEDs saturation control 0% -->100%proportional
--2--0-255Red Fine: Red LEDs saturation control from min. -->max.proportional
2232-0-255Green LEDs saturation control 0% -->100%proportional
--4--0-255Green Fine: Green LEDs saturation control from min. -->max.proportional
3353-0-255Blue LEDs saturation control 0% -->100%proportional
--6--0-255Blue Fine: Blue LEDs saturation control from min. -->max.proportional
474--0-255White/Amber LEDs saturation control 0% -->100%proportional
--8--0-255White/Amber Fine: White(Amber) LEDs saturation control min. -->max.proportional
-----0Green White Fine: Uncorrected white (default)step
--91-1-127Minus green --> uncorrected whiteproportional
-----128Uncorrected white (128=default)step
-----129-255Uncorrected white --> plus greenproportional
-----0Colour temperature correction (CTC): No function (default)step
--102-1-10Tungsten dimming 3200Kstep
--11-20--Tungsten dimming (3200K)step
--21-255--Colour temperature changing 2700K-6500K (21=2700K, 64=3200K, 128=4200K, 192=5600K, 255=6500K)proportional
1135--0-255Dimmer: Light intensity coarse 0% -->100%proportional
126---0-255Dimmer Fine: Light intensity from min. -->max.proportional

Ambiane PW, Ambiane TD (Version 1.1)

Mode 1 Channel Mode 2 Channel Value Function Type of Control
110-255Dimmer: Light intensity coarse 0% -->100%proportional
220-255Dimmer Fine: Light intensity from min. -->max.proportional

Ambiane TW (Version 1.3)

Mode 1 Channel Mode 2 Channel Mode 2 Channel Mode 2 Channel Value Function Type of Control
1--10-255White colour selection: White from 2700K-->4000Kproportional
-1--0-255Warm White: Warm White LEDs saturation control 0% -->100%proportional
-2--0-255Cool White: Cool White LEDs saturation control 0% -->100%proportional
2-3-0-255Dimmer coarse: Light intensity coarse 0% -->100%proportional
--4-0-255Dimmer Fine: Light intensity from min. -->max.proportional

8. Technical Specifications

Input voltage: 48V DC

Protection class: CE: Class III, ETL: Class 2 or LVLE

Max. power consumption: 50W

Beam angle: 67°, 80° (with anti-glare ring)

Colour temperature:

Control Compatibility:

DMX Channels:

Typical Lumen maintenance: 70% @ 50,000 hours

LED life expectancy: Minimum 50,000 hours

Operating ambient temperature range: -20°C to +45°C (-4°F to +113°F)

Operating temperature: 75°C @ Ambient +35°C (167°F @ Ambient +95°F)

Total heat dissipation: 136 BTU/h (calculated)

Cooling: Convection

Housing: Aluminium

Weight: 1.9 kg (4.19 lbs)

Installation method: Via two spring fasteners

IC rating: Non-IC rated

Power/DMX/DALI connection: Terminal blocks

Max. distance between Ambiane AP and Ambiane Power AP: 1m (for 2 x 18AWG cable)

Protection factor: IP20 (without diffuser glass), IP20/IP54 (with Diffuser Glass)

Diagrams:

9. Included Items

10. Optional Accessories

11. Dimensions

The fixture dimensions are as follows:

Diagrams showing front, side, and top views with these measurements are provided.

12. Maintenance

Keep the Ambiane AP unit clean, with particular attention to the light source and the ribbed housing.

13. Software Update Procedure

Software updates for the Ambiane AP can be performed using the ROBE Uploader, a specialized software for automated updates of Robe and Anolis fixtures, leveraging RDM support.

Fixtures must be connected in a daisy-chain (up to 32 units) via a Robe Universal Interface/Robe Universal Interface WTX and a USB cable to a control PC running the Robe Uploader. The control PC requires an active internet connection.

A diagram illustrates the daisy-chain connection: multiple fixtures linked by DMX cables, connected to a Robe Universal Interface, which is then linked via USB to a Control PC connected to the Internet.

Note: When using the Robe Uploader, fixtures are automatically switched into and out of update mode, eliminating the need to manually set DIP 12. The Robe Uploader is not compatible with DALI connections.

Software and Manual Availability

The ROBE Uploader software and its user manual are accessible at: https://www.robe.cz/robe-uploader/

Software Version: 1.7

Last Updated: November 18, 2021

Specifications are subject to change without notice.

Manufactured in the CZECH REPUBLIC by ROBE LIGHTING s.r.o., Palackeho 416/20, CZ 75701 Valasske Mezirici.

Models: Ambiane AP LED Light, Ambiane AP, LED Light, Light

File Info : application/pdf, 10 Pages, 2.65MB

PDF preview unavailable. Download the PDF instead.

User manual Ambiane AP v1.7 November 2021

References

Adobe PDF Library 15.0 Adobe InDesign CC 2015 (Windows)

Related Documents

Preview ROBE Spiider LED WashBeam Luminaire Technical Specification
Detailed technical specifications for the ROBE Spiider, a high-performance LED WashBeam luminaire featuring 18x 30W RGBW and 1x 60W RGBW LEDs, a 12.5:1 zoom system, and advanced effects for professional lighting applications.
Preview Robe Toolkit User Manual
A comprehensive guide to the Robe Toolkit, a multiplatform software for managing, updating, and controlling Robe lighting fixtures. Learn about installation, device management, DMX control, and software updates.
Preview ROBIN iForte LTX WB / LTX FS User Manual
User manual for ROBE's ROBIN iForte LTX WB and ROBIN iForte LTX FS professional lighting fixtures, covering installation, operation, maintenance, and technical specifications.
Preview Robe Ethernet Access Portal (REAP) User Manual
User manual for the Robe Ethernet Access Portal (REAP), detailing its features, settings, and operation for connecting and managing ROBE fixtures.
Preview ROBIN MiniMe User Manual
Comprehensive user manual for the ROBE ROBIN MiniMe lighting fixture, detailing installation, operation, connectivity, safety, and technical specifications for professional lighting applications.
Preview ROBIN LEDBeam 150 FWQ ETH User Manual - Installation, Operation, and Specifications
Comprehensive user manual for the ROBE ROBIN LEDBeam 150 FWQ ETH moving head lighting fixture. Covers safety, installation, DMX/Ethernet connectivity, control menu, maintenance, technical specifications, and photometric data.
Preview Robe Spiider LED WashBeam Luminaire - High-Performance Lighting
Discover the Robe Spiider, a high-performance LED WashBeam luminaire featuring 18 x 40W and 1 x 60W RGBW LEDs, a 12.5:1 zoom optical system (4°-50°), individual pixel control, and advanced features for stunning lighting effects.
Preview Robe ROBIN Esprite User Manual
Comprehensive user manual for the Robe ROBIN Esprite moving head lighting fixture, covering installation, operation, control, and maintenance.