User Manual for Z-Wave models including: Z-Wave, Meter, Plug, Minoston

MP21ZPmanual180807.xls

Z-Wave™ Meter Plug

22 lug 2021 —

Minoston MP21ZP

Manufacturer Manual


File Info : application/pdf, 4 Pages, 676.88KB

PDF preview unavailable. Download the PDF instead.

MP21ZP-manual-20210722
Z-WaveTM Meter Plug

Federal Communications Commission (FCC) Statement

FCC Caution: Any changes or modifications not expressly approved by the party responsible for

compliance could void the user's authority to operate this equipment.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two

conditions: (1) This device may not cause harmful interference, and (2) this device must accept any

interference received, including interference that may cause undesired operation.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,

pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection

against harmful interference in a residential installation. This equipment generates, uses and can

radiate radio frequency energy and, if not installed and used in accordance with the instructions,

may caus harmful interference to radio communications.However, there is no guarantee that

interference will not occur in a particular installation. If this equipment does cause harmful interference

to radio or television reception, which can be determined by turning the equipment off and on,

the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.Increase the separation between the equipment and receiver.Connect the equipment into an outlet on a circuit different from that to which the receiver

Z-WaveTM

is connected.Consult the dealer or an experienced radio/TV technician for help.This equipment

should be installed and operated with minimum distance 20cm between the radiator and your body.

IC Caution:

This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject

to the following two conditions: (1) this device may not cause interference, and (2) this device must

accept any interference, including interference that may cause undesired

operation of the device.

DECLARATION DE CONFORMITE D'INDUSTRIE CANADA

Ce périphérique a été testé et reconnu conforme aux limites spécifiées dans RSS-210.

Son utilisation est soumise aux deux conditions suivantes :

(1) il ne doit pas provoquer d'interférences gênantes et

(2) il doit tolérer les interférences re.ues, notamment cellessusceptibles d'en perturber le fonctionnement.

Meter

Plug

WARRANTY
Minoston Products warrants this product to be free from manufacturing defects for a period of two years from the original date of consumer purchase. This warranty is limited to the repair or replacement of this product only and does not extend to consequential or incidental damage to other products that may be used with this product.
This warranty is in lieu of all other warranties, expressed or implied. Some states do not allow limitations on how long an implied warranty lasts or permit the exclusion or limitation of incidental or consequential damage, so the above limitations may not apply to you.
This warranty gives you specific rights, and you may also have other rights which vary from state to state. if the unit should prove defective within the warranty period.

SPECIFICATIONS

WARNING

Model:MP21ZP

RISK OF FIRE

Power: 120 VAC, 60 Hz.

RISK OF ELECTRICAL SHOCK

Signal (Frequency): 908.42 MHZ.

RISK OF BURNS

Maximum load for outlet 10A, 1200W Resistive

CONTROLLING APPLIANCES:

Maximum load for the Z-WaveTM controlled outlet:

EXERCISE EXTREME CAUTION WHEN USING Z-WaveTM DEVICES TO CONTROL

600W Incandescent, ½ HP Motor or 1200W Resistive

APPLIANCES. OPERATION OF THE Z-WaveTM DEVICE MAY BE IN A DIFFERENT

Range: Up to 100 feet line of sight between the Wireless ControRlOlOeMrTHAN THE CONTROLLED APPLIANCE, ALSO ANUNINTENTIONAL ACTIVATION

and the closest Z-WaveTM receiver module.

MAY OCCUR IF THE WRONG BUTTON ON THE REMOTE IS PRESSED. Z-WaveTM DEVICES

Operating Temperature Range: 32-104° F (0-40° C)

MAY AUTOMATICALLY BE POWERED ON DUE TO TIMED EVENT PROGRAMMING.

DEPENDING UPON THE APPLIANCE, THESE UNATTENDED OR UNINTENTIONAL

Specifications subject to change without notice

OPERATIONS COULD POSSIBLY RESULT IN A HAZARDOUS CONDITION. FOR THESE

due to continuing product improvement

REASONS, WE RECOMMEND DO NOT RETURN THIS PRODUCT TO THE STORE

THE FOLLOWING:

Website:www.nie-tech.com

DO NOT USE Z-WaveTM DEVICES TO CONTROL ELECTRIC

HEATERS OR ANY OTHER APPLIANCES WHICH MAY PRESENT

A HAZARDOUS CONDITION DUE TO UNATTENDED OR

UNINTENTIONAL OR AUTOMATIC POWER ON CONTROL.

Introduction:

The MP21ZP is a Z-WaveTM enabled device and is fully compatible with any Z-Wave PlusTM enabled network.

Each module is designed to act as a repeater,which will re-transmit a radio frequency (RF) signal by routing the

around obstacles and radio dead spots to ensure that the signal is received at its intended destination.

MP21ZP is a security enabled Z-Wave PlusTM device. A security Enabled Z-Wave PlusTM Controller must be used in order to fully utilize

This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers.

All mains operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network."
Key Features:

---Remote ON/OFF control via the Z-WaveTM controller

---Manual ON/OFF control with the front panel push button

---Support Association Group and Auto Report switch status

---Support 5V 2A USB Charging

---Support Z-WaveTM Range Test Tool

A

---Support firmware upgrades via Over-the-air (need Gateways support)

Product Overview:

A AC plug

B Z-WaveTM controlled outlet

C ON/OFF/PROG Push button/ Status LED
C

B

Key Function Description
Function 1: Press button one times to turn the outlet1 ON or OFF Function 2: Press button three times quickly to ADD and REMOVE Function 3: Press and hold button for 6-8 seconds to Z-WaveTM Range test tool Function 4: Press the button twice quickly and then press and hold the button 10S.device will reset
(Node:Please use this procedure only when the network primary controller is missing or otherwise inoperable) Function 5: Press button six times quickly to Change Parameter 17 Value(circulate)
LED Indicate Description
1:LED Indicate Power Meter
White = Plug is off
Dark Blue = 0 ­ 200 W
Cyan = 200 ­ 400 W
Green = 400 ­ 600 W
Orange = 600 ­ 800 W
Red = 800 ­ 1000 W
Purple = 1000 ­ 1200 W
Purple blink = over 1200 W 2:LED Indicate Z-WaveTM Range Test Tool
Solid Green = direct communication with the primary controller is stable Flashing green = direct communication with the primary controller,but the signal is not good Solid orange = communication with the primary controller via repeater nodes,the signal is stable Flashing orange = communication with the primary controller via repeater nodes,but the signal is not good Solid red = communication with the primary controller has failed
Z-WaveTM Remote Control
ADD or Remove the MP21ZP from the existing Z-WaveTM home control network with your primary controller. ---Refer to your primary controller instructions to process the inclusion / exclusion setup procedure. ---When prompted by your primary controller, click the PROG button Three times in one second. Include MP21ZP to/from a Z-WaveTM Gateway with supporting Security.The MP21ZP can support the Primary Controller that implemented the Notice: Including a node ID allocated by Z-WaveTMTM Controller means "Add" or "Inclusion". Excluding a node ID allocated by Z-WaveTMTM Controller means "Remove" or "Exclusion".
Z-WaveTM MULTI_CHANNEL
MP21ZP is multi channel deviceIt has three endpoints. Outlet-1 is Endpoint1, outlet-2 is Endpoint2. USB is Endpont3. MP21ZP Endpoint1 / Endpoint2 Device Type
Generic Device Class: GENERIC_TYPE_SWITCH_BINARY Specific Device Class: SPECIFIC_TYPE_POWER_SWITCH_BINARY

Z-WaveTM protocol Command Class Node Info
COMMAND_CLASS_ZWAVEPLUS_INFO, COMMAND_CLASS_SWITCH_BINARY, COMMAND_CLASS_ASSOCIATION, COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION COMMAND_CLASS_ASSOCIATION_GRP_INFO, COMMAND_CLASS_TRANSPORT_SERVICE COMMAND_CLASS_VERSION, COMMAND_CLASS_MANUFACTURER_SPECIFIC, COMMAND_CLASS_DEVICE_RESET_LOCALLY, COMMAND_CLASS_POWERLEVEL, COMMAND_CLASS_CONFIGURATION, COMMAND_CLASS_NOTIFICATION COMMAND_CLASS_METER COMMAND_CLASS_SECURITY_2, COMMAND_CLASS_MULTI_CHANNEL COMMAND_CLASS_SUPERVISION COMMAND_CLASS_FIRMWARE_UPDATE_MD

The Below listed Command Class are all supported the Security S2
COMMAND_CLASS_VERSION, COMMAND_CLASS_SWITCH_BINARY, COMMAND_CLASS_ASSOCIATION, COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION COMMAND_CLASS_ASSOCIATION_GRP_INFO, COMMAND_CLASS_MULTI_CHANNEL COMMAND_CLASS_MANUFACTURER_SPECIFIC, COMMAND_CLASS_DEVICE_RESET_LOCALLY, COMMAND_CLASS_POWERLEVEL, COMMAND_CLASS_CONFIGURATION, COMMAND_CLASS_NOTIFICATION COMMAND_CLASS_METER COMMAND_CLASS_FIRMWARE_UPDATE_MD
MP21ZP protocol Endpoint 1
Full Command Class Node Info
COMMAND_CLASS_ZWAVEPLUS_INFO, COMMAND_CLASS_ASSOCIATION, COMMAND_CLASS_ASSOCIATION_GRP_INFO, COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION COMMAND_CLASS_SWITCH_BINARY, COMMAND_CLASS_METER COMMAND_CLASS_SUPERVISION, COMMAND_CLASS_SECURITY_2
The Below listed Command Class are all supported the Security S2
COMMAND_CLASS_ASSOCIATION, COMMAND_CLASS_ASSOCIATION_GRP_INFO, COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION COMMAND_CLASS_SWITCH_BINARY, COMMAND_CLASS_METER
MP21ZP protocol Endpoint 2
Full Command Class Node Info
COMMAND_CLASS_ZWAVEPLUS_INFO, COMMAND_CLASS_ASSOCIATION, COMMAND_CLASS_ASSOCIATION_GRP_INFO, COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION COMMAND_CLASS_SWITCH_BINARY, COMMAND_CLASS_METER_V4, COMMAND_CLASS_SUPERVISION, COMMAND_CLASS_SECURITY_2
The Below listed Command Class are all supported the Security S2
COMMAND_CLASS_ASSOCIATION, COMMAND_CLASS_ASSOCIATION_GRP_INFO, COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION COMMAND_CLASS_SWITCH_BINARY, COMMAND_CLASS_METER,

MP21ZP protocol Endpoint 3

Full Command Class Node Info
COMMAND_CLASS_ZWAVEPLUS_INFO, COMMAND_CLASS_ASSOCIATION, COMMAND_CLASS_ASSOCIATION_GRP_INFO, COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION, COMMAND_CLASS_SWITCH_BINARY, COMMAND_CLASS_SUPERVISION, COMMAND_CLASS_SECURITY_2
The Below listed Command Class are all supported the Security S2
COMMAND_CLASS_ASSOCIATION, COMMAND_CLASS_ASSOCIATION_GRP_INFO, COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION, COMMAND_CLASS_SWITCH_BINARY
Z-WaveTM Configuration Parameters

You may use the below configuration parameters to change settings of the corresponding functionality.

1Restores state after power failure

Paramter No: 1(0x01) Size:1 Byte Value: 00(default) The state before a power outage.

Value: 01 Value: 02

outlet on outlet off

2Power Wattage Report Value Threshold(Wattage)

Value Scope :0----65535W

Paramter No: 2(0x02) Size:4 Byte

Value: xx xx xx xx (Default 10W)

Value: 00 00

3Power Wattage Report Frequency (Timer)

Value Scope :30----2678400S

Paramter No: 3(0x03) Size:4 Byte

Value: xx xx xx xx (Default 30S)

Disabled

4Energy (kWh) Report Frequency (Timer) Paramter No: 4(0x04) Size:4 Byte

Value Scope :30----2678400S Value: xx xx xx xx (Default 300S)

5Voltage (V) Report Frequency (Timer) Paramter No: 5(0x05) Size:4 Byte

Value Scope :30----2678400S Value: xx xx xx xx (Default 300S)

6Electricity (A) Report Frequency (Timer) Paramter No: 6(0x06) Size:4 Byte

Value Scope :30----2678400S Value: xx xx xx xx (Default 300S)

7Overload Protection (Current)

Value Scope :1----16A

Paramter No: 7(0x07) Size:1 Byte

Value: xx (Default 13A)

8Endpoint1 Enable Auto Turn-OFF Timer

Paramter No: 8(0x08) Size:1 Byte

Value=0 Auto Turn-OFF Timer Disabled (default);

Value=1 Auto Turn-OFF Timer Enabled

9Endpoint1 Count Down Configuration(Turn off the output by time

Paramter No: 9(0x09) Size:4 Byte

Value: xx xx Turn off Output

Value Scope :1----65535Minutes (default:60M)

10Endpoint1 Enable Auto Turn-ON Timer

Paramter No: 10(0x0A) Size:1 Byte

Value=0 Auto Turn-ON Timer Disabled (default);

Value=1 Auto Turn-ON Timer Enabled

11Endpoint1 Count Down Configuration(Turn on the output by time

Paramter No: 11(0x0B) Size:4 Byte

Value: xx xx xx xx Turn off Output

Value Scope :1----65535Minutes (default:60M)

12:Endpoint2 Enable Auto Turn-OFF Timer

Paramter No: 12(0x0C) Size:1 Byte

Value=0 Auto Turn-OFF Timer Disabled (default);

Value=1 Auto Turn-OFF Timer Enabled

13:Endpoint2 Count Down Configuration(Turn off the output by time

Paramter No: 13(0x0D) Size:4 Byte

Value: xx xx xx xx Turn off Output

Value Scope :1----65535Minutes (default:60M)

14:Endpoint2 Enable Auto Turn-ON Timer

Paramter No: 14(0x0E) Size:1 Byte

Value=0 Auto Turn-ON Timer Disabled (default);

Value=1 Auto Turn-ON Timer Enabled

15:Endpoint2 Count Down Configuration(Turn on the output by time

Paramter No: 15(0x0F) Size:4 Byte

Value: xx xx xx xx Turn off Output

Value Scope :1----65535Minutes (default:60M)

16:Manual Control Paramter No: 16(0x10) Size:1 Byte
17:Status LED Configuration

Value=0 Manual Control Disabled Value=1 Manual Control Enabled (default);

Paramter No: 17(0x11) Size:1 Byte

(default:Value=01 )

Value: 00

LED indicator will display power consumption whenever the device is plugged in

Value: 01

LED indicator will display power consumption whenever the device is ON in and will turn off when the plug is OFF

Value: 02

LED indicator will display the level of power consumption for 5 seconds only whenever the device is turned on

Value: 03 Always OFF
Support for Association Groups

MP21ZP supports 3 association groups. Group 1 support 1 node ID,Group 2--3 Support maximum of 5 node ID's

Association group_1:Z-Wave PlusTM Lifeline Association group_1 is default to associate with the primary controller (Gateway/Hub/Controller) for MP21ZP Status change report, 1. MP21ZP will trigger AUTO report function if the Switch status had been changed.
Association group_2:basic set command When the output of the MP21ZP Enpoint1 socket is changed, On (0xFF) or Off (0x00)orOverload, The MP21ZP will automatically send out a related basic set command. On (0xFF) or Off (0x00) to its associated group.
Association group_3:basic set command When the output of the MP21ZP Enpoint2 socket is changed, On (0xFF) or Off (0x00)orOverload, The MP21ZP will automatically send out a related basic set command. On (0xFF) or Off (0x00) to its associated group.
Support for Overload Protection
MP21ZP support Overload Protection ,When the MP21ZP load exceeds the overload setting value, the overload signal is sent out Notification Type : Overload 0x08 . Event :Overload detected 0x08
Restoring Factory Defaults
MP21ZP is removed from the network and will be restored to the factory setting
All Configuration Parameters values and Association information will be restored to factory default settings and excluded from the network. Remark : All the setting and data will be permanently deleted. Please use this procedure only when the network primary controller is missing or otherwise inoperable.



References

Microsoft: Print To PDF