ActronAir WALL HUNG DS SERIES SPLIT SYSTEM
Product Overview
The ActronAir WALL HUNG DS SERIES SPLIT SYSTEM offers advanced climate control solutions, combining reverse cycle operation with inverter technology for efficient and superior performance.
Key Features
- Reverse Cycle Wall Hung Split System
- Mono and Multi Compatible Heads
- Single Rotary Inverter Compressor
- Superior Operating Range: Cooling up to 50°C DB, Heating down to -15°C DB
- Adjustable Airflow with 3D Multi-Directional Airflow (Up/Down Auto Swing ⬆️⬇️, Left/Right Auto Swing ↔️)
- Louvre Position Memory
- Multiple Fan Speeds (Auto, Low, Medium, High)
- Powder Coated Outdoor Unit Panels
- Hydrophilic Indoor and Outdoor Coil Protection [Corrosion Resistance] ?
- Self-Diagnosis [?] and Auto Protection [?️]
- Fire Proof Electrical Box (Indoor and Outdoor Units) [Flame Retardant] ?
- Dehumidification Mode
- Super Ionizer Technology [Air Purification] ?
- Intuitive Proximity Sensor [Motion Sensing] ?
- Uses R-32 low GWP Refrigerant
- Optional UVC Device [Sterilization] ?
- Built-In Wi-Fi ?
- I-Clean Function [Self-Cleaning] ✨
- Demand Response Ready [Smart Grid Compatible] ?
Control Features (RC-02 Controller)
- Digital Display
- Auto Restart After Power Failure
- Timer ON / OFF Operation
- Remote ON / OFF Input
- Manual ON / OFF Operation
- 12-speed Indoor Fan
- 5-speed Outdoor Fan
- Sleep Mode ?
- Boost Mode [?]
- Quiet Operation ?
- Dry Mode Operation ?
- Auto Defrost Function ❄️
- Follow Me Function ?
- Mute Operation ?
- Self Clean Function ✨
Unit Options
- Left or Right Hand Drain Connection
- Fault Alarm Output
Optional Accessories
- WC-03 Wired Controller
- Multi-Function PCB (required for wired controller installation)
Unit Compliance
The units comply with various Australian and International standards, including:
- AS/NZS 3823.2 (MEPS)
- AS/NZS 3823.1.1
- AS/NZS 4755.3.1 (DRM 1, 2 and 3)
- AS/NZS CISPR 14.1 (EMC)
- IEC 60335.1 (ELECTRICAL APPLIANCE SAFETY)
- IEC 60335.2.40 (ELECTRICAL APPLIANCE SAFETY - AIR CONDITIONERS)
Technical Specifications Summary
The following table summarizes key specifications across the DS Series models. Detailed specifications for each model, including operating ranges, electrical characteristics, dimensions, airflow, sound pressure, and refrigerant details, are available in the original document.
Model | Cooling Capacity (kW) | Heating Capacity (kW) | EER / AEER | COP / ACOP | Indoor Dimensions (HxWxD mm) | Outdoor Dimensions (HxWxD mm) |
---|---|---|---|---|---|---|
WRC/WRE-026DS | 2.63 | 2.70 | 5.40 / 5.38 | 5.41 / 5.39 | 295x795x225 | 555x765x303 |
WRC/WRE-035DS | 3.50 | 3.90 | 4.67 / 4.65 | 4.58 / 4.57 | 315x965x239 | 554x805x330 |
WRC/WRE-050DS | 5.05 | 6.00 | 4.32 / 4.31 | 4.03 / 4.02 | 370x1140x297 | 673x890x342 |
WRC/WRE-060DS | 6.00 | 6.60 | 3.81 / 3.80 | 3.75 / 3.75 | 370x1140x297 | 673x890x342 |
WRC/WRE-072DS | 7.20 | 8.20 | 3.61 / 3.61 | 3.94 / 3.94 | 370x1140x297 | 673x890x342 |
WRC/WRE-080DS | 8.00 | 9.00 | 3.37 / 3.37 | 3.70 / 3.70 | 370x1140x297 | 673x890x342 |
WRC/WRE-090DS | 9.00 | 9.80 | 3.53 / 3.53 | 3.71 / 3.71 | 370x1140x297 | 810x946x410 |
Capacity Selection Data
The original document contains extensive tables detailing cooling and heating capacity selection for all models under various operating conditions (indoor/outdoor temperatures, airflow rates). These tables are crucial for system design and performance verification.
Pipe Length Correction Multipliers
Correction factors for pipe length and height differences between indoor and outdoor units are provided in detailed tables within the original document. These are essential for ensuring optimal performance and efficiency in different installation scenarios.
Unit and Mounting Dimensions
Detailed dimensions for both outdoor and indoor units are provided, along with recommended service access areas and airflow clearances. This information is critical for proper installation planning and ensuring adequate ventilation.
Outdoor Unit Dimensions and Mounting
Model Number | Outdoor Unit Dimensions (mm) HxWxD | Mounting Dimensions Distance A (mm) | Mounting Dimensions Distance B (mm) |
---|---|---|---|
WRC-026DS | 555 x 765 x 303 | 452 | 286 |
WRC-035DS | 554 x 805 x 330 | 511 | 317 |
WRC-050DS | 673 x 890 x 342 | 663 | 354 |
WRC-060DS | 673 x 890 x 342 | 663 | 354 |
WRC-072DS | 673 x 890 x 342 | 663 | 354 |
WRC-080DS | 673 x 890 x 342 | 663 | 354 |
WRC-090DS | 810 x 946 x 410 | 673 | 403 |
Indoor Unit Dimensions
Model | Nominal Dimensions H (mm) | Nominal Dimensions W (mm) | Nominal Dimensions D (mm) |
---|---|---|---|
WRE-026DS | 295 | 795 | 225 |
WRE-035DS | 315 | 965 | 239 |
WRE-050DS | 370 | 1140 | 297 |
WRE-060DS | 370 | 1140 | 297 |
WRE-072DS | 370 | 1140 | 297 |
WRE-080DS | 370 | 1140 | 297 |
WRE-090DS | 370 | 1140 | 297 |
Service Access Areas / Airflow Allowances: Minimum clearances are recommended around units for proper airflow and service access. For outdoor units, 300mm+ above, 150mm+ to sides, 400mm+ to front, and 600mm+ height clearance are suggested. Indoor units require 50mm+ clearance on sides and 1800mm+ below.
Wiring Diagrams
The document includes detailed wiring diagrams for both outdoor and indoor units for each model in the DS Series. These diagrams illustrate the electrical connections, component layouts, and optional connections for features like Demand Response (DRED) and remote switches. They are intended for qualified installers.
- Outdoor Unit Wiring Diagrams (WRC-026DS to WRC-090DS)
- Indoor Unit Wiring Diagrams (WRE-026DS to WRE-090DS)