Instructions for iSMACONTROLLI models including: SFAR-S-8AO Modbus I-O Module, SFAR-S-8AO, Modbus I-O Module, I-O Module, Module
il y a 5 jours — 8x Voltage or current output,. Resolution of the transmitter 14 bits. Range output. 0 V to 10 V; 0 mA to 20 mA; 4 mA to 20 mA. Isolation. Max 1000 V DC.
Innon Support (http://support.innon.com)
File Info : application/pdf, 3 Pages, 423.69KB
DocumentDocumentSFAR-S-8AO JUMPER SETTING Power supply Supply output Analog output Range output Isolation Interface Baudrate Ingress protection Temperature Relative humidity Connectors Dimension Mounting Housing material SPECIFICATION Voltage 10-38 V DC; 10-28 V AC Power consumption 1,25 W @ 24 V DC 1,5 VA @ 24 V AC DC: 20-30 V 4,5 W; AC: 20-28 V 5 VA 8x Voltage or current output, Resolution of the transmitter 14 bits 0 V to 10 V; 0 mA to 20 mA; 4 mA to 20 mA Max 1000 V DC RS485, up to 128 devices on the bus From 2400 to 115200 bps IP40 for indoor installation Operating -10°C - +50°C; Storage - 40°C - +85°C 5 to 95% RH (without condensation) Max 2.5 mm2 119,1 mm x 101 mm x 22,6 mm DIN rail mounting (DIN EN 50022) Plastic, self-extinguishing PC/ABS TOP PANEL ANALOG OUTPUTS COMMUNICATION POWER SUPPLY WARNING TERMINALS OF THE DEVICE ·Note, an incorrect wiring of this product can damage it and lead to other hazards. Make sure the product has been correctly wired before turning the power ON. · Before wiring, or removing/mounting the product, be sure to turn the power OFF. Failure to do so might cause electric shock. · Do not touch electrically charged parts such as the power terminals. Doing so might cause electric shock. · Do not disassemble the product. Doing so might cause electric shock or faulty operation. · Use the product within the operating ranges recommended in the specification (temperature, humidity, voltage, shock, mounting direction, atmosphere etc.). Failure to do so might cause fire or faulty operation. · Firmly tighten the wires to the terminal. Insufficient tightening of the wires to the terminal might cause fire iSMA CONTROLLI S.p.A. Via Carlo Levi 52, 16010 Sant'Olcese (GE) - Italy | support@ismacontrolli.com www.ismacontrolli.com Installation Instruction| 1st Issue rev. 3 | 01/2022 page 1 Registered access Modbus Dec Hex Register Name Access 30001 0 0x00 Version/Type Read 30002 1 0x01 Switches Read 40003 2 0x02 Baud rate Read & Write 40004 3 0x03 Stop Bits & Data Bits Read & Write 40005 4 0x04 Parity Read & Write 40006 5 0x05 Response Delay Read & Write 40007 6 0x06 Modbus Mode Read & Write 40009 8 0x08 Watchdog Read & Write 40033 32 0x20 Received packets LSR (Least Significant Reg.) Read & Write 40034 40035 40036 40037 40038 30051 40053 40054 40055 40056 40057 40058 40059 40060 33 0x21 Received packets MSR (Most Significant Reg.) Read & Write 34 0x22 Incorrect packets LSR Read & Write 35 0x23 Incorrect packets MSR Read & Write 36 0x24 Sent packets LSR Read & Write 37 0x25 Sent packets MSR Read & Write 50 0x32 Outputs Read 52 0x34 Analog output 1 Read & Write 53 0x35 Analog Output 2 Read & Write 54 0x36 Analog Output 3 Read & Write 55 0x37 Analog Output 4 Read & Write 56 0x38 Analog Output 5 Read & Write 57 0x39 Analog Output 6 Read & Write 58 0x3A Analog Output 7 Read & Write 59 0x3B Analog Output 8 Read & Write Description Version and Type of the device Switches state RS485 baud rate No of Stop bits & Data Bits Parity bit Response delay in ms Modbus Mode (ASCII or RTU) Watchdog No of received packets No of received packets with error No of sent packets Bit is set if value 0 Value of Analog Output: in mV for voltage output (max 10240) in A for current output 0 20 mA (max 20480) in for current output 4-20 mA (max 1000) Modbus Dec Hex Register Name Access 40061 40062 40063 40064 40065 40066 40067 40068 40069 40070 40071 40072 40073 40074 40075 40076 60 0x3C Default output 1 value Read & Write 61 0x3D Default output 2 value Read & Write 62 0x3E Default output 3 value Read & Write 63 0x3F Default output 4 value Read & Write 64 0x40 Default output 5 value Read & Write 65 0x41 Default output 6 value Read & Write 66 0x42 Default output 7 value Read & Write 67 0x43 Default output 8 value Read & Write 68 0x44 Output 1 setting Read & Write 69 0x45 Output 2 setting Read & Write 70 0x46 Output 3 setting Read & Write 71 0x47 Output 4 setting Read & Write 72 0x48 Output 5 setting Read & Write 73 0x49 Output 6 setting Read & Write 74 0x4A Output 7 setting Read & Write 75 0x4B Output 8 setting Read & Write Description Default value of output set when power is on or when watchdog reset occurs Setting of output mode: 0 output disabled 1 voltage output 2 current output 0-20 mA 3 current output 4-20 mA Caution! For the change to take effect, you must also set the jumper inside the module. iSMA CONTROLLI S.p.A. Via Carlo Levi 52, 16010 Sant'Olcese (GE) - Italy | support@ismacontrolli.com www.ismacontrolli.com Installation Instruction| 1st Issue rev. 3 | 01/2022 page 2 INSTALLATION GUIDELINE Please read the instruction before use or operating the device. In case of any questions after reading this document, please contact the iSMA CONTROLLI Support Team (support@ismacontrolli.com). · Before wiring or removing/mounting the product, make sure to turn the power off. Failure to do so might cause an electric shock. · Improper wiring of the product can damage it and lead to other hazards. Make sure that the product has been correctly wired before turning the power on. · Do not touch electrically charged parts such as power terminals. Doing so might cause an electric shock. · Do not disassemble the product. Doing so might cause an electric shock or faulty operation. · Use the product only within the operating ranges recommended in the specification (temperature, humidity, voltage, shock, mounting direction, atmosphere, etc.). Failure to do so might cause a fire or faulty operation. · Firmly tighten the wires to the terminal. Failure to do so might cause a fire. · Avoid installing the product in close proximity to high-power electrical devices and cables, inductive loads, and switching devices. Proximity of such objects may cause an uncontrolled interference, resulting in an instable operation of the product. · Proper arrangement of the power and signal cabling affects the operation of the entire control system. Avoid laying the power and signal wiring in parallel cable trays. It can cause interferences in monitored and control signals. · It is recommended to power controllers/modules with AC/DC power suppliers. They provide better and more stable insulation for devices compared to AC/AC transformer systems, which transmit disturbances and transient phenomena like surges and bursts to devices. They also isolate products from inductive phenomena from other transformers and loads. · Power supply systems for the product should be protected by external devices limiting overvoltage and effects of lightning discharges. · Avoid powering the product and its controlled/monitored devices, especially high power and inductive loads, from a single power source. Powering devices from a single power source causes a risk of introducing disturbances from the loads to the control devices. · If an AC/AC transformer is used to supply control devices, it is strongly recommended to use a maximum 100 VA Class 2 transformer to avoid unwanted inductive effects, which are dangerous for devices. · Long monitoring and control lines may cause loops in connection with the shared power supply, causing disturbances in the operation of devices, including external communication. It is recommended to use galvanic separators. · To protect signal and communication lines against external electromagnetic interferences, use properly grounded shielded cables and ferrite beads. · Switching the digital output relays of large (exceeding specification) inductive loads can cause interference pulses to the electronics installed inside the product. Therefore, it is recommended to use external relays/contactors, etc. to switch such loads. The use of controllers with triac outputs also limits similar overvoltage phenomena. · Many cases of disturbances and overvoltage in control systems are generated by switched, inductive loads supplied by alternating mains voltage (AC 120/230 V). If they do not have appropriate built-in noise reduction circuits, it is recommended to use external circuits such as snubbers, varistors, or protection diodes to limit these effects. Electrical installation of this product must be done in accordance with national wiring codes and conform to local regulations. iSMA CONTROLLI S.p.A. Via Carlo Levi 52, 16010 Sant'Olcese (GE) - Italy | support@ismacontrolli.com www.ismacontrolli.com Installation Guideline| 1st Issue rev. 1 | 05/2022