SL-910 Remote Display USER'S MANUAL
NOV 2023
www.selletonscales.com

FEATURES
· Connects to your indicator to display live weight on a larger screen · Bright LED segment display is readable in high and low light · 6 digit display · Painted metal construction with acrylic lens · For indoor use only · Two mounting holes located on back · Connects to most indicators
MOUNTING DIMENSIONS
A
D
C
B

3" display 5" display 8" display

SL-910-3

A 21.25"

B

7.25"

C 12.75"

D

1.25"

SL-910-5

A 30.75"

B 10.25"

C 14.25"

D

1.50"

CONNECTOR

SL-910-8

A 39.00"

B 19.75"

C 23.35"

D

3.25"

Black Ground
Red Recieve

5

1

4

2

3

SET-UP EXAMPLE
Here is an example of how to pair your scoreboard to SellEton's most popular indicators. To set up SL-910 remote display, parameter settings need to be changed on your SL-7510 or SL-7516 indicator to allow communication between the two devices.

SL-7510 PARAMETER SETTINGS

To enter parameter settings, follow the procedure below:

1. Press and hold the HOLD and PRINT key at the same time for 2 seconds

2. Use the arrow keys to change C01 to C18

3. Press the PRINT

key to enter/edit the parameter setting

4. Use the arrow keys to change the settings of the below parameters

5. Press the ACCUM key to save and exit parameter settings

SL-7516 PARAMETER SETTINGS

To enter calibration/parameter settings, follow the procedure below:

1. Press and hold the ON/OFF and SET key at the same time for 2 seconds

2. Use the arrow keys to change C01 to C18

3. Press the SET

key to enter/edit the parameter setting

4. Use the arrow keys to change the settings of the below parameters

5. Press the ON/OFF key to save and exit parameter settings

Function

Parameter Settings/Options

Communication Setting

C18

Baud Rate

C19

Set the serial interface data output method: 0 = Turn off serial interface data output 1 = Continuous sending mode, for remote display 2 = Print mode, for ticket printer 3 = Command request mode, connect computer. 4 = PC continuous sending mode, connect computer
0=1200 (SL-910 remote display) 1=2400 2=4800 3=9600

For more help, contact us at: 844-735-5386

Remote Display Continuous Sending Mode
Note: Baud Rate must be set to 1200

Output Continuous Format

SSSS

C

T WWW X X X X X X X X X X X X C K

XABC

RS

1

2

3

4

56

0
1 0 1 0 1
0 1

State A

Bits0,1,2

1

2

0 1 1 0 0 Bits3,4

0 0 0 1 1
1 0

Decimal point position XXXXXX0 XXXXXXX XXXXX.X XXXX.XX XXX.XXX Division X1 X2

BitsS Bits0 Bits1 Bits2 Bits3 Bits4 Bits5 Bits6

State B
function gross=0, net=1 Symbol: positive=0, negative=1 Overload (or under zero)=1
dynamic=1 unit: lb=0, kg=1
Constant 1 Constant 0

State C

Bit2

Bit1

Bit0

unit

0

0

0

Kg or lb

0

0

1

g

0

1

0

t

Bit 3

printing=1

Bit 4

Extend display=1

Bit 5 Bit 6

Constant 1 Constant 0

